Tender For special Repair Of Bathroom/Toilet And Re-Wiring With E/M And B/R Fixture Of Bldg No P-1(B) And (C) Or Line ,P-2(B) (Or Mess), P-4 (Jco Mess ) And P-14 (Mt Shed) At Cams Under Ge (South) , Delhi Cantt-10
Tender Value
1.42 Crore
Estimated cost
Bid Submission
07 Sep 2026
28 days left
EMD
2.18 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair Of Bathroom/Toilet And Re-Wiring With E/M And B/R Fixture Of Bldg No P-1(B) And (C) Or Line ,P-2(B) (Or Mess), P-4 (Jco Mess ) And P-14 (Mt Shed) At Cams Under Ge (South) , Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling water tanks of capacity exceeding 500litres but not exceeding 1000 litres complete all as specified and directed.. |
| 2 | Disconnecting existing tanks capacity exc 500 and n exc 1000 ltr , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) |
| 3 | Cleaning and removing all scale and dirt, etc, from tanks(1000 Ltr) and from mouths of circulating pipes, etc. |
| 4 | Taking up or down steel tubing 20 mm bore and connection including cleaning for refixing. complete all as specified and as directed. |
| 5 | Supplying and laying of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 6 | Taking up or down steel tubing 15mm bore and connection including cleaning for refixing. complete all as specified and as directed. |
| 7 | Supplying and laying of 16mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 8 | S&F 16mm Brass Tee for CPVC fitting |
| 9 | S&F 16mm Brass Elbow for CPVC fitting |
| 10 | S&f 20mm tank adaptor for CPVC fitting |
| 11 | S&F 16mm UNION for CPVC fitting |
| 12 | S&F 20mm UNION for CPVC fitting |
| 13 | S&F 16mm Ball valve for CPVC fitting |
| 14 | S&F 20mm Ball valve for CPVC fitting |
| 15 | S&F 1000 ltr capacity triple layer, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part II. Make: Jindal/Pollywell/Rotex or equivalent |
| 16 | S&F 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed |
| 17 | Dismantling of brick tiles (laid flat or on edge) on roof surface.laid bedded and pointed in any mortar |
| 18 | Demolition of mud in roof, any thickness, including plastering and leeping incl necessary scaffolding arrangement complete all as specified and directed(whether full thickness removed or only a part there of) and removing from cantonment area or as directed complete all as directed by Engr in charge and specified. |
| 19 | Demolition of cement concrete (unreinforced) in any description and in any position not otherwise specially provided for. |
| 20 | M&L for brushing neat cement slurry with 3.00 Kg of cement per Sqm on existing surfaces all as directed by Engr-in-Charge. |
| 21 | M&L 40 mm thick (average thickness) plain cement concrete 1:2:4 type B-0 using (12.5 mm graded aggregate), as in roof ,padding to maintain the uniform slope complete all as specified and directed. |
| 22 | M & L for rendering 15 mm thick (average) plaster on concrete surfaces in CM (1:4) on roof, mixed with water proofing compound and finishing the surface even and smooth without using extra cement all as specified and directed. |
| 23 | M & L for Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered and hold fast on edge including necessary form work complete. |
| 24 | S&F APP based polymeric water proofing membrane minimum weighing 3 Kg/sqm and 3mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm laid over and including applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per sqm by torch application including cleaning of surface complete all as per approved manufacturer's instructions. complete all as specified and directed by Engineer-in-Charge.Note:-The water proofing treatment shall be carried out by manufacturer or their auth applicators as per manufactures instruction and as directed by Engr in Charge. |
| 25 | M&L for preparation of new surface of APP membrane and applying two coats of aluminium paint at surfaces of any description, over 10cm in width or girth,not otherwise described |
| 26 | Supply only integral liquid water proofing compound complete all as specified & directed . |
| 27 | Taking down rain water pipe (any size) or pattern incl all fittings, head shoes, bends swan necks etc incl cleaning or re-fixing or removal to store(measured overall as fixed along the centre line over fittings and accessories complete. |
| 28 | S&F for PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, of 110 mm dia complete all as specified and directed. |
| 29 | S&F for PVC (SWR) bends any radius 110mm dia bore |
| 30 | Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc including scaffolding for up to two storey building complete all as specified and directed. |
| 31 | M&L for 15mm thick ready mix plaster cement plaster (Self curing) upto G+5 storey Building including necessary scaffolding etc complete all as specified and as directed. Note : Rate quoted shall be up to G+2 storey Building including necessary scaffolding etc. |
| 32 | M&L for 10mm thick ready mix plaster cement plaster (Self curing) upto G+5 storey Building including necessary scaffolding etc complete all as specified and as directed. Note : Rate quoted shall be up to G+2 storey Building including necessary scaffolding etc. |
| 33 | M&L for 5mm thick ready mix plaster cement plaster (Self curing) upto G+5 storey Building including necessary scaffolding etc complete all as specified and as directed. Note : Rate quoted shall be up to G+2 storey Building including necessary scaffolding etc. |
| 34 | M&L for preparation of newly plastered surfaces on external wall/ ceiling, applying two more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm.complete all as specified and directed by Engr-in-Charge.Note :- Before 1st coat and 2nd coat, stage passing required by the Engr-in-charge/GE. |
| 35 | M&L for preparation of old plastered surfaces on external wall/ ceiling, complete removal of existing treatment, washing, rubbing down and stopping of painted surface andapplying two more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 Sqm .complete all as specified and directed by Engr-in-Charge. Note :- Before 1st coat and 2nd coat, stage passing required by the Engr-in-charge/GE. |
| 36 | M&L for preparation of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing scraping down smoke soot moulds moss and efflorescent salts and treating oily & greasy spots and filling of holes and cracks with suitable material like cement or wall care putty and there after applying two coat of white wash on walls, coloumns and stair case area upto G+1 stories including scaffolding arrangements complete. Note :- Before 1st coat and 2nd coat, stage passing required by the Engr-in-charge/GE. |
| 37 | M&L for preparation of plastered or unplastered old decorated surfaces of ceiling by brooming down or steel wire brushing scraping down smoke soot moulds moss and efflorescent salts and treating oily & greasy spots and filling of holes and cracks with suitable material like cement or wall care putty and there after applying two coat of white wash on Ceiling complete. Note :- Before 1st coat and 2nd coat, stage passing required by the Engr-in-charge/GE. |
| 38 | Complete removal of existing treatment of surfaces and applying two coats of oil emulsion distemper over a coat of wall care putty (avg 1mm thick) complete all as specified and directed. |
| 39 | M&L for Preparation decorated plastered surfaces of wall and ceiling and apply one coat of oil emulsion distemper over filling crack,marks by white putty and make wall surface smooth and finish complete all as specified and directed by Engr-In-Charge. |
| 40 | M&L for complete removal surface and preparation decorated plastered surfaces of wall and ceiling and apply two coat of oil emulsion distemper over filling crack,marks by white putty and make wall surface smooth and finish complete all as specified and directed by Engr-In-Charge. |
| 41 | M&L for Preparation undecorated plastered surfaces of wall and apply two coat of oil emulsion distemper over a coat of wall putty and make wall surface smooth and finish complete all as specified and directed by Engr-In-Charge. |
| 42 | M&L for Preparation undecorated plastered surfaces of wall and apply two coat of white wash and make wall surface smooth and finish complete all as specified and directed by Engr-In-Charge. |
| 43 | Demolition of reinforcement Concrete of any description and in any position not otherwise specifically provided for |
| 44 | M&L for Reinforced cement concrete type B-1 (1:2:4) using 20 mm graded aggregates for chajjas, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like (necessary form work is included with the item rate upto four sotrey bldgs) |
| 45 | S&F for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed . |
| 46 | S&F for Mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed . |
| 47 | S&F for Mild steel TMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed .(Note : Aditional Reinforcement: In the case of the shear relnforcement also,if the diameter of the rebars are reduced, provide 8mm dia stirrups In the form of 7 \\"U\\" shaped bars. Tie them properly so that it has a tight contactwith the main bars.) Please Enable Macros to View BoQ information |
| 48 | S&F for Mild steel TMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed .(Note : Aditional Reinforcement: In the case of the shear relnforcement also,if the diameter of the rebars are reduced, provide 8mm dia stirrups In the form of 7 \\"U\\" shaped bars. Tie them properly so that it has a tight contactwith the main bars.) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 28 daysSep 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 30 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender