Public Administrative Department Government Departments Closing in 4 days TDR #56904205

Tender For Repair And Painting Work On The First Floor Of The Primary Health Centre Located At Tuti Masjid In Jawahar Nagar Under Ward-05, Zone-04, .

Issued by Government Departments · Kanpur, Uttar Pradesh
Tender Value
3.84 Lakhs
Estimated cost
Bid Submission
14 Aug 2026
4 days left
EMD
38410
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Painting Work On The First Floor Of The Primary Health Centre Located At Tuti Masjid In Jawahar Nagar Under Ward-05, Zone-04, .

BOQ

Name of Work:- Repair and painting work on the first floor of the Primary Health Centre located at Tuti Masjid in Jawahar Nagar under Ward-05, Zone-04, .
Sl. No. Item Description
1Dismantling existing plaster including disposal of refuse as directed by Engineer-In-Charge within a distance of 60 meters. Dismantling existing plaster including disposal of refuse as directed by Engineer-In-Charge within a distance of 60 meters.
212mm cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. 12mm cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement
3Finishing walls with Putty approved brand and manufacture and of required shade on undacorated wall surface Finishing walls with Putty approved brand and manufacture and of required shade on undacorated wall surface to give even shade over including curing and cost of all material, labour, T&P etc. required for proper completion of work
4Finishing walls with exterior emulsion paint (Apex) Finishing walls with exterior emulsion paint (Apex) of approved brand and manufacture and of required shade on undacorated wall surface to give even shade over @ 1.25 Ltr/l0sqm including one coat of primer applld @ 0.75Ltr/10sqm coat curing and cost of all material, labour, T&P etc. required fororooer comoletlon of work.for two coat
5Providing and Fixing of 1/2 x 24 gauge Murga jali etc all complete. Providing and Fixing of 1/2 x 24 gauge Murga jali etc all complete.
6Scrapping old white or colour wash including disposal of refuse as directed by Engineer-In-charge within a distance of 60 meters (200 feet) Scrapping old white or colour wash including disposal of refuse as directed by Engineer-In-charge within a distance of 60 meters (200 feet)
7Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of Joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.\\" \\"Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of Joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured.\\"
8DISTEMPERING-Painting on iron work with one coat of priming coat and two coat with superior synthetic enamel including supply of all material etc all comp. Painting on iron work with one coat of priming coat and two coat with superior synthetic enamel including supply of all material etc all comp
9Tile work in skirting risers of steps and dado up to 2m height over 12mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) 8mm thick Tile work in skirting risers of steps and dado up to 2m height over 12mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) 8mm thick etc all comp
10Providing and laying Vitrified tiles In different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % Size of TIie 600x600 mm Providing and laying Vitrified tiles In different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, In all colours & shade, In skirting. riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), Jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the init with white cement & matching pigments etc. complete.
11Concrete/R.C.C. Work-Concrete /R.C.C Work 1:1½:3 (1 Cement: 1½ coarse sand (zone-Ill) : 3 graded stone aggregate 20 mm nominal size)
12Wiring point for fan/fresh air fan (light duty exhaust fan) with 1 sq. mm. FR PVC insulated multistrand single core copper conducter cable in PVC conduit pipe on surface, complete with 14 SWG copper earth continuity wire, piano type switch & ceiling rose on 3 mm. thick phenolic laminated backelite sheet etc. But in PVC conduit with 1.5 sq. mm. FR PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. Wiring points in surface conduit with PVC Insulated 1100 V garde cable. complete in all respects. Wiring point for fan/fresh air fan (light duty exhaust fan) with 1 sq. mm. FR PVC insulated multistrand single core copper conducter cable in PVC conduit pipe on surface, complete with 14 SWG copper earth continuity wire, piano type switch & ceiling rose on 3 mm. thick phenolic laminated backelite sheet etc. But in PVC conduit with 1.5 sq. mm. FR PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. Wiring points in surface conduit with PVC Insulated 1100 V garde cable. complete in all respects.-
13Wiring point for light with 1.5sq mm FR PVC insulated single core copper conductor cable in pvcconduct pipe on surface, complete with 14 SWG copper earth continuity wire, piano type switch and ceiling rose/angle/batten holder on 3mm thick phenolic laminated backelite-sheet etc. But in PVC cunduct with 1.5 sq.mm. FR PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduct. Wiring points in surface Cinduct with PVC insulated 1100 V grade cable. complete in all respects, a directed. Wiring point for light with 1.5sq mm FR PVC insulated single core copper conductor cable in pvcconduct pipe on surface, complete with 14 SWG copper earth continuity wire, piano type switch and ceiling rose/angle/batten holder on 3mm thick phenolic laminated backelite-sheet etc. But in PVC cunduct with 1.5 sq.mm. FR PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduct. Wiring points in surface Cinduct with PVC insulated 1100 V grade cable. complete in all respects, a directed
14Supply and fitting of ceiling fan Usha, Khetan, Bajaj I.S.I mark including all complete. Supply and fitting of ceiling fan Usha, Khetan, Bajaj I.S.I mark including all complete.
15Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect
16Supply and fixing of switch box 250 x 250 x 65 mm size of approved make made up of 1.0 mm thick ISI Marked G.P.sheet Supply and fixing of switch box 250 x 250 x 65 mm size of approved make made up of 1.0 mm thick ISI Marked G.P.sheet
17Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25metre height, above ground level, including additional rows of scaffolding in stepped manner, as per reuiqurement of site, made with 40mm dia M.S. tube, placed 1.5metre centre to centre, horizontal and vertical tubes joint with clamps and maintaining it in a serviceable condition for execution of work of cleaning and/or pointing and/or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc, complete as per directions and approval of engineer-in-charge. Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25metre height, above ground level, including additional rows of scaffolding in stepped manner, as per reuiqurement of site, made with 40mm dia M.S. tube, placed 1.5metre centre to centre, horizontal and vertical tubes joint with clamps and maintaining it in a serviceable condition for execution of work of cleaning and/or pointing and/or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc, complete as per directions and approval of engineer-in-charge
18Add 18 % G.S.T. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56904205
AUTHORITY Government Departments
TENDER VALUE 3.84 Lakhs
LAST DATE 14-08-2026
Authority
Authority Name Kanpur Municipal Corporation
Work Description Tender for Repair And Painting Work On The First Floor Of The Primary Health Centre Located At Tuti Masjid In Jawahar Nagar Under Ward-05, Zone-04, .
Basic Detail
Tender No 206/AA-4/26-27
Bidding Type Tender
Location
City Kanpur
State Uttar Pradesh
Key Dates
Publish Date 07 Aug 2026
Submission Date 14 Aug 2026
Open Date 14 Aug 2026
Finance
Tender Value 3.84 Lakhs
Tender Fee 1180
EMD 38410
Exemption Not Available
Document List
87737810-2c61-4090-91a8-7eec2cdecb1e.html
BOQ_2208853.xls
Tendernotice_1 (32).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

87737810-2c61-4090-91a8-7eec2cdecb1e.html

xls

BOQ_2208853.xls

pdf

Tendernotice_1 (32).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders