Tender For Repairing Of Cable Trench,Construction Of Cb Steps And Waterproofing Work Of Control Room At 400 Kv S/S Katni
Tender Value
17.72 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
20 days left
EMD
35440
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Katni → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairing Of Cable Trench,Construction Of Cb Steps And Waterproofing Work Of Control Room At 400 Kv S/S Katni
BOQ
| Sl. No. | Item Description |
| 1 | 400 KV S/s Katni |
| 2 | 14.64, 3013262. Chipping, Removing, Carefully loose plaster and Concrete work by low impact Hammer, Breaker without damaging the structure as Instructed by Engineer-in-Charge. |
| 3 | 22.22, 3014527.Water proofing treatment over Roof, Wall, Chajjas. Balcony with fibre glass mesh and Sealer coat at leakage/ seepage area consisting of (i) Surface preparation roughening of surface, opening cracks in 'V' groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely. (ii) Providing and applying 1st coat of fibre glass mesh (minimum thicknes 70-80 micron) and two component flexible waterproof and protective modified mortar, dry powder 80%chemical 20% acrylic resin having 30% solid contents) with mix proportion of part 1 and 2 with proper mixing with laying of fiber glass mesh (of weaving size of 10X10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to air cure for minimum 2 Hrs. After two hours of 1st coat applying 2nd coat (minimum thickness 100 micron) of fibre glass mesh of with mix proporation of part 1 and 2 with proper mixing. Allow the coating to air cure for minimum 2 hrs. Consumption of two component should be acrylic resin @17.90 kg for 10 sqm area or as per manufacture instructions. (After two coats of diamond shield, surface is to be cured properly minimum for 4 hrs. before application of third coat). (iii) Providing and applying 1st coat of sealer coat 50-60 micron (single component Hight build elastomeric, fixable pure acrylic waterproofing membrane having solid content of 65%) and allow it to air cure for 4Hrs.minimum. After two hours minimum of 1st coat applying 2nd and finals coat 120-140 micron of sealer coat and allow it to air cure for 4 Hrs mimimum. Consumption of Sealer coat should be @ 5.40 kg per 10 sqm area. (iv) The treated area should be cure with water for 48 hrs. by flooding the surface. (v) The final appearance of the coating will be milky white. All above operations to be done in order.(five years guarantee) |
| 4 | 2.6, 3011472. Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil |
| 5 | 4.1.2.3, 3011580 \\"Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level :..With 40mm nominal size graded stone aggregate..M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate....\\" |
| 6 | 4.3.1, 3011589. \\"Centering and shuttering including strutting, propping etc. and removal of form work for :..Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth.\\" |
| 7 | 4.2.1.2, 3011584. \\"Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor two level, excluding the cost of centering, shuttering and finishing :..With 20mm nominal size graded stone aggregate..M-20 - Grade concrete.\\" |
| 8 | 5.16.6, 3011694 \\"Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detalingIS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3.Couplers shall be conforming to IS code on \\"Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification\\")..Thermo-Mechanically Treated bars.FE 500 D or more conforming to IS 1786..\\" |
| 9 | 4.3.3, 3011591. \\"Centering and shuttering including strutting, propping etc. and removal of form work for :..Above plinth: Columns, pillars, posts and struts.\\" |
| 10 | 308NSOR, 3018353, Chequered plate cover for cable trench C Type Construction of civil work as per standard drawings and details mentioned in SMB vide page No. Vol-II/P-67 |
| 11 | 310NSOR, 3018355. Chequered plate cover for cable trench E Type Construction of civil work as per standard drawings and details mentioned in SMB vide page No.Vol-II/P-69 |
| 12 | 9.172.1, 3012350. \\"Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid door/window/ceosetory windows and other frames/chowkhat comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (woodpowder/ rice .husk/wheat husk) and non toxic additives (maximum toxicity indexof 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed S.S. screws having minimum density of 750 kg/m3 and screw withdrawal strength of 2200 N (Face) & 900 N (Edge), minimum compressive strength 58 N/mm2 , modulus of elasticity 900 N/ mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S. hold fast/lugs/S.S.dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/lugs or S.S. dash fasteners shall be paid separately)..Single rebate (75 mm X 50 mm) \\" |
| 13 | 10.14.1, 3012536. \\"Steel work in built up M.S. tubularsection (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washersetc. complete...Hot finished welded type tubes\\" |
| 14 | 6.7.1.1, 3011780. \\"Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor two level in :..Having 100 kg / cm2 average compressive strength..\\" |
| 15 | 13.1.1, 3013015 \\"12 mm cement plaster of mix :..1:4 (1 cement : 4 sand) \\" |
| 16 | 13.50, 3013089, Finishing walls by any mechanical or manual means with water proofing cement paint of required shade: New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 17 | 11.79.1.1, 3012765 \\"Providing and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours & shades, 1st quality/ premium quality in skirting, dado and wall lining laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting thejoints with white cement and matching pigments etc. complete..In light shade glossy/ rustic /stain finished..(a) Size 600X600 mm thickness 9-10 mm\\" |
| 18 | 15.11.1, 3013337, \\"Dismantling tile/ Kota stone/ Marble / Granite work in floors/walls and roofs laid in cement mortar including stacking material within 50 metres lead...For thickness of tiles 10 mm to 25 mm.\\" Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysSep 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender