Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Research Institute; Miscellaneous, As Per Atc; As Per Atc - Dismantling Of Ms Pipe Upto 50Mm With Insulation And Other Accessories Etc As Per Site R
Tender Overview
Project Description
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Research Institute; Miscellaneous, As Per Atc; As Per Atc - Dismantling Of Ms Pipe Upto 50Mm With Insulation And Other Accessories Etc As Per Site Requirements , Dismantling Of Ms Pipe Above 50Mm But Below 100Mm With Insulation And Other Accessories Etc As Per Site Requirements , Dismantling Of Floor/Ceiling Mounted Ahus Upto 3000 Cfm And Its Control Panels Etc Completed In All Respect , Dismantling Of Ms Pipe Above 100Mm Below 150 Mm With Insulation And Other Accessories Etc As Per Site Requirements , Dismantling Of Ms Pipe Above 150Mm But Below 250Mm With Insulation And Other Accessories Etc As Per Site Requirements , Dismantling Of Butterfly Valve/Nrv/3&2-Way Valve/Strainers With Insulation And Other Accessories Upto 100Mm Completed In All Respect , Dismantling Of Canvas Connection, Nut-Bolts Etc Complete In All Respect , Installation Of Ahus Alongwith Its Control Panels, Wiring Etc Completed In All Respect , Installation Of Old Ms Pipe With Welding Cutting, Flanges Etc Upto 50Mm With 50Mm Nitrile Rubber Insulation Applied By Suitable Adhesive Etc As Per Site Requirements , Installations Of Old Ms Pipe With Welding Cutting, Flanges Etc Above 50Mm But Below 100Mm With 50 Nitrile Rubber Insulation Applied By Suitable Adhesive Etc As Per Site Requirements , Installation Of Old Butterfly Valve/Nrv/3&2-Way Valve/Strainers With 50Mm Nitrile Rubber Insulation Applied By Suitable Adhesive, Nut-Bolt, Washer, Gasket Etc Upto 100Mm Completed In All Respect , Supply And Installation Of Double Canvas Connection As Per Site Requirement. , Dismantling Of Ceiling Suspended Ducting Of Different Shape, Size And Thickness Alongwith The Supporting Etc Completed In All Respect , Dismantling Of Fall Ceiling (Wooden, Metal, Gypsum Board) Etc Completed In All Respect Including Shifting Of Malwa Within The C Us , Providing A Skilled Manpower I.E Welder/Mechanic/Carpenter/Painter Etc Alongwith The All Necessary Tools And Tackels On Daily Basis As Per The Site Requirement. , Providing A Unskilled Manpower Alongwith The All Necessary Tools And Tackels On Daily Basis As Per The Site Requirement. , Providing And Applying Two Coat Of Enamel Paint With One Coat Of Primer Etc On Metal Items As Per Site Requirement Etc Including Labour Etc. , Providing And Fixing Of Heavy Duty Ms Angle/Chequer Plate Etc Completed With Welding Cutting, Two Coat Of Enamel Paint With One Coat Of Primer Etc As Per Site Requirement Etc As Per Site Requirement. , Sitc Of Two Way Valve With Actuator, Temperature Controller, Transformer, Wiring Etc As Per Site Requirement Complete In All Respect. , Sitc Of Actuator, Temperature Controller, Transformer, Wiring Etc (For Two Valve) As Per Site Requirement Complete In All Respect. , Supply Of High Torque Valve Actuator, Model No. Sql36e110, Ac 230+10%/-5%, 50/60Hz, 235Va, 12S/90 Deg., Ed30%, -20T +70 Deg.C, Ip 67, Ss304 Nut-Bolt Etc Compatible With The Existing Bms Software Including Servicing Of Inline Butterfly Valve, Dismantling Of Old Valve & Actuator , Installation Alongwith The Bms Configration, Testing And Commissioning Of Above Valve , Providing And Fixing Of 1200Cfm Fan Coil Unit With 4-6 Row Chilled Water Coil, Other Accessories Etc , Providing And Fixing Of 1000Cfm Fan Coil Unit With 4-6 Row Chilled Water Coil Other Accessories Etc , Providing And Fixing Of Double Skin 2000Cfm Fan Coil Unit With 4-6 Row Chilled Water Coil Other Accessories Etc , Providing And Fixing Of Double Skin 3000Cfm Fan Coil Unit With 4-6 Row Chilled Water Coil Other Accessories Etc , Providing And Applying The Duco Paint Of The Approved Shade With Two Or More Coats With All Materials And Tools Etc , Dismantling & Removal Of Following Capacities Air Handling Units Alongwith Puf Injected Cabinets, Blower, Motors, Evaporators Pads, Cooling Coils, Pulley Drives, Belts Etc, Disconnecting Of Metallic Connections, Ducts, Canvass Connections, Chilled Water Pipes, Humidifier Pipes, Other Accessories, Electrical Cables, Control Cables, Bms Cables/Wires, Earthing Strips/Wires Etc Connected With Outlived Ahu. The Job Includes Complete Dismantling & Removal Of Apu/Ahu With Lifting & Shifting As Per Direction Of Engineer-In-Charge I/C Crane Charges, Heavy Labour, Chain Pulley Blocks Etc As Required. , Dismantling & Removal Of Following Capacities Exhaust Air Units Alongwith Puf Injected Cabinets, Blower, Motors, Pulley Drives, Belts Etc, Disconnecting Of Metallic Connections, Ducts, Canvass Connections, Other Accessories, Electrical Cables, Control Cables, Bms Cables/Wires, Earthing Strips/Wires Etc Connected With Outlived Ea Units. The Job Includes Complete Dismantling & Removal Of Ea Units With Lifting & Shifting As Per Direction Of Engineer-In-Charge I/C, Crane Charges, Heavy Labour, Chain Pulley Blocks Etc As Required. , Sitc Of Factory Built Multistage Air Processing Unit/ Ahu Of Following Capacity Constructed Out Of 270 Zinc Coated, 0.80 Mm Thick Pre-Coated Gp Sheet From Outer Side And B161shall Have Seperate Section Of Blower, Chw Coils, Celldeck Pad, Filters Etc. Casing Shall Be Of Non - Skeleton Construction With Thermal Break Profile Ahu Complete With Backward Curved Aerofoil Blade Plug Fan Direct Driven Type Alongwith Energy Efficient Motor Suitable For Operations On 415 Volts + 5 Volts, 50 Hz, 3 Phase Ac Supply, Compatible With Vfd Arrangement, Chilled Water Cooling Coils And Copper Tubes, Pre-Filter Eu-4 (Box Type) On Common Frame, Drain Connections With Stainless Steel Drain Tray And Necessary Vibration Isolator To Avoid Any Vibration, Connecting Flanges Including Making Construction Of Foundation Blocks Etc Including Connecting With Ahu Motors Etc As Required , Supply, Installation, Testing & Commissioning Of Following Capacity Floor Mounted/ Tailor Made Design Floor Mounted/Ceiling Suspended Type Double Skin Exhaust Air Unit Fabricated Out Of 0.80Mm Thick Gi Pre-Coated Sheet On Outer Side And 0.80Mm Thick Gi Plain Sheet On Inner Side Having Puf Injected Insulation With 25Mm Thickness Density Not Less Than 32 Kg/M3, Sand Witched Between Gi Sheet Panel For Acoustic Thermal Application Comprising Of Centrifugal Forward Curved Didw Blowers, Tefc Weather Proof Motor Of Ip-55 Class F Insulation, Eff 1, Direct/Belt Drive And Pulley Mounted On Motor And Fan Shaft, Belt Guard, Motor & Fan Mounted On Common Base Plate/Suitable Arrangement. Fan Assembly Shall Be Statically And Dynamically Balanced. Eurovent Approved Unit Complete As Per Specifications, This Item Also Includes Pre-Filter & Carbon Filters Including Making Construction Of Foundation Blocks/Ms Frame As Required Etc Including Connecting With Ahu Motors Etc As Required. , Supplying, Laying/ Fixing, Testing And Commissioning Of Following Nominal Sizes Of Chilled Water Piping Inside The Building (With Necessary Cl S, Vibration Isolators And Fittings But Excluding Valves, Strainers, Gauges Etc.) Duly Insulated With Following Closed Cell Elastomeric Nitrile Rubber Of Minimum 45 Kg / Cu M Density, Thermal Conductivity 0.037 W/Mk Or Better At 20 Deg Mean Temperature Class O Insulation Applied By Suitable Adhesive Complete Including Repairing Of Damage To Building Etc. As Per Specifications And As Required Complete In All Respect. Note:-The Pipes Of Sizes 150Mm & Below Shall Be M.S. C Class As Per Is : 1239 And Pipes Size Above 150Mm Shall Be Welded Black Steel Pipe Heavy Class As Per Is: 3589, From Minimum 6.35Mm Thick M.S. Sheet For Pipes Upto 350 Mm Dia. And From Minimum 7Mm Thick Ms Sheet For Pipes Of 400 Mm Dia And Above , Supplying, Laying, Fixing, Testing And Commissioning Of Following Thickness Closed Cell Elastrometric Nitrile Rubber Of Class 0 Applied By Suiatable Adhesive, As Per Specifications And As Required Complete In All Respect. , Supplying, Fixing, Testing And Commissioning Of Following Valve, Strainers, Gauges In The Chilled Water Plumbing Duly Insulated To The Same Specifications As The Connected Piping And Adequately Supported As Per Site Requirement. , Providing And Fixing In Position The Industrial Type Pressure Gauges With Gun Metal / Brass Valves Complete As Required , Providing & Fixing In Position The Mercury In Glass Industrial Type Thermometers. , Supplying, Fixing, Testing And Commissioning Of Condenser Water Pipes Of Following Sizes Of Ms Cclass Along With Necessary Cl S, Vibration Isolators And Fittings Such As Bends,Tees Etc. But Excluding 225 Delhi Schedule Of Rates (E&M)-2025 Valves, Strainers, Gauges Etc. Adequately Supported On Rigid Supports Duly Painted/Buried In Ground Excavation And Refilling Etc. As Per Specification And As Required Complete In All Respect. Note:-The Pipes Size 150Mm & Below Shall Be M.S. C Class As Per Is : 1239 And Pipes Size Above 150Mm Shall Be Welded Black Steel Pipe Heavy Class As Per Is: 3589, From Minimum 6.35Mm Thick M.S. Sheet For Pipes Upto 350 Mm Dia. And From Minimum 7Mm Thick Ms Sheet For Pipes Of 400 Mm Dia And Above , Butterfly Valve (Manual) With C I Body Ss Disc Nitrile Sheet & O - Ring & Pn 16 Pressure Rating Asspecified. , Non - Return Valve With Dual Plate Of C I Body Ss Plates Vulcanized Nbr Seal Flanged End & Pn 16Pressure Rating As Specified , Supplying, Fixing, Testing And Commissioning Of Following Sizes Motorized Butter Fly Valve With Ci Body, Ss Disc,O - Ring And Minimum Pn-16 Pressure Rating , Conforming To Bs 5155, Is 13095, With Ip-55 Actuator, Capable Of Accepting Upto 10V Dc , And Upto 20Ma Electric Signal And Providing Similar Transduced Feedback Output To Control System As Required. , Supplying, Installation, Testing And Commissioning Of Following Sizes Electronic, Self-Balancing, Pressure Independent Type Dynamic Balancing Valve With Integrated 2 Way Modulating Control Valve In A Single Body. The Actuator Shall Be Capable Of Accepting Upto 10V Dc And Upto 20Ma Electric Signal And Shall Provide Similar Transduced Feedback Output To Controlsystem. Maximum Close Off Pressure Shall Not Be Less Than 6 Bar For Upto 50 Mm Valves And 7 Bar For 65 Mm & Above. Valves Should Have Pressure Rating Of 25 Bar Minimum , Supply, Installation, Balancing And Commissioning Of Fabricated At Site Gss Sheet Metal Rectangular/Round Ducting Complete With Neoprene Rubber Gaskets, Elbows, Splitter D Ers, Vanes, Hangers, Supports Etc. As Per Approved Drawings And Specifications Of Following Sheet Thickness Complete As Required. , Supply, Installation, Testing And Commissioning Of Motorized (On-Off Type) Duct Mounted Gi Volume Control D Er With Enthalpy Sensor And Necessary Control Wire (Minimum 1.5 Sqmm) For Integration Within Ahu Room , Supplying & Fixing Of Powder Coated Extruded Aluminium Supply Air Grills With Aluminium Volume Control D Ers As Per Specifications. , Supplying & Fixing Of Powder Coated Extruded Aluminium Return Air Grills With Louvers But Without Volume Control D Ers Complete As Required. , Supplying, Fixing,Testing And Commissioning Of Fire D Ers In Supply Air Duct/Main Branch And Return Air Path As And Where Required Of Required Sizes I/C Control Wiring,The D Er Shall Be Motorized And Spring Return So As To Close The D Er In The Event Of Power Failure Automatically And Open The Same In Case Of Power Being Restored. The Spring Return Action Shall Be Inbuilt Mechanism And Not Externally Mounted. The D Er Shall Also Be Closed In The Event Of Fire Signal Complete As Required And As Per Specifications. , Supply And Fixing Of Acoustic Lining Of Supply Air Duct And Plenum With 25 Mm Thick Resin Bonded Glass Wool Having Density Of 32 Kg/Cum, With 25 Mm X 25 Mm Gi Section Of 1.25 Mm Thick, At 600 Mm Centre To Centre Covered With Reinforced Plastic Tissue Paper And 0.5 Mm Thick Perforated Aluminum Sheet Fixed To Inside Surface Of Ducts With Cadmium Plated Nuts, Bolts, Stick Pins, Cprx Compound Etc. Complete As Required And As Per Specifications. , Supplying And Fixing Of Following Thickness Duly Laminated Aluminium Foil Of Mat Finish Closed Cellnitrile Rubber (Class O) Insulation On Existing Duct After Applying Suitable Adhesive For Nitrile Rubber. The Joints Shall Be Sealed With 50 Mm Wide And 3 Mm Thick Self Adhesive Nitrile Rubber Tape Insulation Complete As Per Specifications And As Required , Providing And Fixing Of 15 Mm Thick Cross Link Polythyline (Xlp/Xlpe) Insulation For Ducting, Main Plenum And Supply Duct I/C Cleaning Of Duct, Cutting And Pasting Of (Xlp/Xlpe) With The Help Of Adhesive (Sr 505) And 100 Mm Adhesive Based Nitrile Tape For Making The Joint Etc Complete As Per Relevant Is And Site Condition. , Supplying, Cutting And Fixing Of Plain Aluminum Sheet Of 26 Gauge Thick For Inner/ Outer Ducts Insulated Ducting From Unit To Complete Insulated Ducting Including Hardwares Such As Nut Bolts Etc. The Item Includes The Cost Of Scaffolding (Nothing Shall Be Paid Extra On Account Of Necessary Shifting And Scaffolding Etc). , Providing And Applying Frp Lining/Coating 1-2 On Ducting As Per Requirement In Ahu Room And Other Specified Area`S Etc As Required. , Providing And Applying Harder 1-2 (Two-Three Layers Of Approved Colour Shed) With Fibre Mesh On Insulated Pipeline Up To 200 Mm Dia Pipe As Per Requirement In Ahu Room And Other Specified Area, Etc, As Required. , Supply, Installation, Testing And Commissioning Of Mv Panel Boards Cubical Type, Compartmentalised Design Fabricated From 2 Mm/ 1.6 Mm Thick Crca Sheet Having Necessary Cable Alleys, Powder Coated Through Nine Tank Process Facility For Pricking And Degreasing, Dust And Vermin Proof, Suitable For Operation On 440 V 3 Phase, 50 Hz, A.C. Supply With Necessary Mccbs / Mcbs / Mpcbs Electrical Works : And Other Accessories, Ip 44 Protection Complete In All Respects Including Internal Wiring, Labels, Ferrules, Cable Termination, Gland Plates, Earth Terminals, Painting Etc. Conforming To Specifications. All Mccb Shall Be With Rotary Handle And Pad Locking Arrangements Complete With Incoming And Outgoing Feeders And Accessories As Described Below:Note:- I). Wall Mounted/ Floor Frame Arrangement Is Included In The Scope Of Work.Ii). Panel Shall Be Design As Per Site Requirement, Noting Shall Be Paid Extra On Account Of Change In Outgoing Switchgears Nos. & Ratings But Not Change Main Incomer Capacity. Bidder Shall Access The Site Condition And Quote Accordingly. , Supply, Installation, Testing And Commissioning Of Mv Panel Boards Cubical Type, Compartmentalised Design Fabricated From 2 Mm/ 1.6 Mm Thick Crca Sheet Having Necessary Cable Alleys, Powder Coated Through Nine Tank Process Facility For Pricking And Degreasing, Dust And Vermin Proof, Suitable For Operation On 440 V 3 Phase, 50 Hz, A.C. Supply With Necessary Mccbs / Mcbs / Mpcbs Electrical Works : And Other Accessories, Ip 44 Protection Complete In All Respects Including Internal Wiring, Labels, Ferrules, Cable Termination, Gland Plates, Earth Terminals, Painting Etc. Conforming To Specifications. All Mccb Shall Be With Rotary Handle And Pad Locking Arrangements Complete With Incoming And Outgoing Feeders And Accessories As Described Below:Note:-I). Wall Mounted/ Floor Frame Arrangement Is Included In The Scope Of Work.Ii). Panel Shall Be Design As Per Site Requirement, Noting Shall Be Paid Extra On Account Of Change In Outgoing Switchgears Nos. & Ratings But Not Change Main Incomer Capacity. Bidder Shall Access The Site Condition And Quote Accordingly. , Supply, Installation, Testing And Commissioning Of Mv Panel Boards Cubical Type, Compartmentalised Design Fabricated From 2 Mm/ 1.6 Mm Thick Crca Sheet Having Necessary Cable Alleys, Powder Coated Through Nine Tank Process Facility For Pricking And Degreasing, Dust And Vermin Proof, Suitable For Operation On 440 V 3 Phase, 50 Hz, A.C. Supply With Necessary Mccbs / Mcbs / Mpcbs Electrical Works : And Other Accessories, Ip 44 Protection Complete In All Respects Including Internal Wiring, Labels, Ferrules, Cable Termination, Gland Plates, Earth Terminals, Painting Etc. Conforming To Specifications. All Mccb Shall Be With Rotary Handle And Pad Locking Arrangements Complete With Incoming And Outgoing Feeders And Accessories As Described Below:Note:-I). Wall Mounted/ Floor Frame Arrangement Is Included In The Scope Of Work.Ii). Panel Shall Be Design As Per Site Requirement, Noting Shall Be Paid Extra On Account Of Change In Outgoing Switchgears Nos. & Ratings But Not Change Main Incomer Capacity. Bidder Shall Access The Site Condition And Quote Accordingly. , Supply, Testing And Commissioning Of Xlpe Copper Conductor And Aluminium Conductor Armoured Control/Power Cable As Per Relevant Is/Ie Rules And Site Condition Of The Following Size. , Supply, Installation, Testing And Commissioning Of Humidification Package Unit Comprising Of Pan Type Heater, Control Wiring, Casing Of Powder Coated Ms/Gi Sheet Etc. As Required , Sitc Of 36Pxd Controller , Sitc Of 12Pxd Controller , Providing And Fixing Of 25Mm Thick Double-Skinned Puff Panel With 0.80 Mm Thick Powder-Coated Gp Sheet From The Inner And Outer Side Having Density 42 Kg/Cum Puf Injected, , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. , Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required , Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays Bends With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling Withm.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. , Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays Tee With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling Withm.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. , Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays Cross Member With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling Withm.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. , Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays Reducer With Perforation Not More Than 17.5%, Joined With Connectors, Suspended From The Ceiling Withm.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As , Strip Heaterssupplying, Installation, Testing And Commissioning Of Electric Strip Heaters Of Capacities (3 Kw Each Set Of Heaters In Plenum/Return Air Chamber- 2 Nos Of Ahu`S) For Monsoon Reheat And Winter Heating Arranged In Banks Complete With Cooling / Heating Thermostats (Th), Humidistats (Hu), Safety Stats (Sf) Etc. As Per Details Given Below For Ahus/ Plenums Complete With Interwiring (But Excluding Cable And Connection From Ahu Switch Board) And Connections Etc. Complete As Required And As Per Specifications. - , Supplying, Installation, Testing And Commissioning Of Dp Switch Compatible With Existing Bms System Alongwith The All Accessories Etc As Per Site Requirement Completed In All Respect. , Supplying, Installation, Testing, Commissioning And Configuration Of Digital Display Unit (Temp., Rh, Room Pressure) Compatible And Configuration With Existing Bms System Alongwith The All Accessories Etc As Per Site Requirement Completed In All Respect. , Supplying, Installation, Testing And Commissioning Of Following Size Ss304 Ball Valve With Ss304 Nipple At Both End As Per Site Requirement Completed In All Respect. , Supply, Installation, Testing And Commissioning Of Isi Mark Cpvc Valve And Pipe With Other Accessories I.E Elbow, Bend, Tee , Cooper Connection/Socket Etc Heavy Duty Of Following Size , Supply, Installation, Testing And Commissioning Of 4-To 6 Row Deep Cooling Coil Made Of 0.4Mm Thick & ½ Dia. (Hair Pin Bend Copper Tubes) Copper Tube, Aluminium Fins, 37Gauge & 11-13 Fins Per Inch, Ms Coil Header, Galvanized Coil Casing, Suitable Size Of Ss Drain Pan, Ceiling Compound Etc Complete In All Respect Including Providing Of Canvas Connection, Insulation, Cutting-Welding Works Etc & Similar To Existing Above 3000Cfm But Below 4000Cfm Including Leak Testing And Pressure Testing At 300 Psi. I/C Removal Of Damaged Cooling Coil From Ahu, Cutting-Welding, Insulation, Canvas Connections Etc. And Complete As Per Site Requirement. The Cooling Coil Should Be Certified By Ahri Or Ashrae. , Supply, Installation, Testing And Commissioning Of 4 Row Deep Cooling Coil Made Of 0.4Mm Thick & ½ Dia. (Hair Pin Bend Copper Tubes) Copper Tube, Aluminium Fins, 37Gauge & 11-13 Fins Per Inch, Ms Coil Header, Galvanized Coil Casing, Suitable Size Of Ss Drain Pan, Ceiling Compound Etc Complete In All Respect Including Providing Of Canvas Connection, Insulation, Cutting-Welding Works Etc & Similar To Existing Above 1500Cfm But Below 3000Cfm Including Leak Testing And Pressure Testing At 300 Psi. I/C Removal Of Damaged Cooling Coil From Ahu, Cutting-Welding, Insulation, Canvas Connections Etc. And Complete As Per Site Requirement. The Cooling Coil Should Be Certified By Ahri Or Ashrae. , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required , Above 185 Sq. Mm And Upto 400 Sq. Mm (Cl Ed With 40X3mm Ms Flat Cl ) , Supplying And Fixing Cable Route Marker With 10 Cm X 10 Cm X 5 Mm Thick G.I. Plate With Inscription There On, Bolted /Welded To 35 Mm X 35 Mm X 6 Mm Angle Iron, 60 Cm Long And Fixing The Same In Ground As Required. , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Dismantling of MS pipe upto 50mm with insulation and other accessories etc as per site requirements | Dismantling of MS pipe upto 50mm with insulation and other accessories etc as per site requirements |
| 2 | Dismantling of MS pipe above 50mm but below 100mm with insulation and other accessories etc as per site requirements | Dismantling of MS pipe above 50mm but below 100mm with insulation and other accessories etc as per site requirements |
| 3 | Dismantling of floor/ceiling mounted AHUs upto 3000 CFM and its control panels etc completed in all respect | Dismantling of floor/ceiling mounted AHUs upto 3000 CFM and its control panels etc completed in all respect |
| 4 | Dismantling of MS pipe above 100mm below 150 mm with insulation and other accessories etc as per site requirements | Dismantling of MS pipe above 100mm below 150 mm with insulation and other accessories etc as per site requirements |
| 5 | Dismantling of MS pipe above 150mm but below 250mm with insulation and other accessories etc as per site requirements | Dismantling of MS pipe above 150mm but below 250mm with insulation and other accessories etc as per site requirements |
| 6 | Dismantling of butterfly valve/NRV/3&2-way valve/strainers with insulation and other accessories upto 100mm completed in all respect | Dismantling of butterfly valve/NRV/3&2-way valve/strainers with insulation and other accessories upto 100mm completed in all respect |
| 7 | Dismantling of canvas connection, nut-bolts etc complete in all respect | Dismantling of canvas connection, nut-bolts etc complete in all respect |
| 8 | Installation of AHUs alongwith its control panels, wiring etc completed in all respect | Installation of AHUs alongwith its control panels, wiring etc completed in all respect |
| 9 | Installation of old MS pipe with welding cutting, flanges etc upto 50mm with 50mm nitrile rubber insulation applied by suitable adhesive etc as per site requirements | Installation of old MS pipe with welding cutting, flanges etc upto 50mm with 50mm nitrile rubber insulation applied by suitable adhesive etc as per site requirements |
| 10 | Installations of old MS pipe with welding cutting, flanges etc above 50mm but below 100mm with 50 nitrile rubber insulation applied by suitable adhesive etc as per site requirements | Installations of old MS pipe with welding cutting, flanges etc above 50mm but below 100mm with 50 nitrile rubber insulation applied by suitable adhesive etc as per site requirements |
| 11 | Installation of old butterfly valve/NRV/3&2-way valve/strainers with 50mm nitrile rubber insulation applied by suitable adhesive, nut-bolt, washer, gasket etc upto 100mm completed in all respect | Installation of old butterfly valve/NRV/3&2-way valve/strainers with 50mm nitrile rubber insulation applied by suitable adhesive, nut-bolt, washer, gasket etc upto 100mm completed in all respect |
| 12 | Supply and installation of double canvas connection as per site requirement. | Supply and installation of double canvas connection as per site requirement. |
| 13 | Dismantling of ceiling suspended ducting of different shape, size and thickness alongwith the supporting etc completed in all respect | Dismantling of ceiling suspended ducting of different shape, size and thickness alongwith the supporting etc completed in all respect |
| 14 | Dismantling of fall ceiling (wooden, metal, gypsum board) etc completed in all respect including shifting of malwa within the campus | Dismantling of fall ceiling (wooden, metal, gypsum board) etc completed in all respect including shifting of malwa within the campus |
| 15 | Providing a skilled manpower i.e welder/mechanic/carpenter/painter etc alongwith the all necessary tools and tackels on daily basis as per the site requirement. | Providing a skilled manpower i.e welder/mechanic/carpenter/painter etc alongwith the all necessary tools and tackels on daily basis as per the site requirement. |
| 16 | Providing a unskilled manpower alongwith the all necessary tools and tackels on daily basis as per the site requirement. | Providing a unskilled manpower alongwith the all necessary tools and tackels on daily basis as per the site requirement. |
| 17 | Providing and applying two coat of enamel paint with one coat of primer etc on metal items as per site requirement etc including labour etc. | Providing and applying two coat of enamel paint with one coat of primer etc on metal items as per site requirement etc including labour etc. |
| 18 | Providing and fixing of heavy duty MS angle/chequer plate etc completed with welding cutting, two coat of enamel paint with one coat of primer etc as per site requirement etc as per site requirement. | Providing and fixing of heavy duty MS angle/chequer plate etc completed with welding cutting, two coat of enamel paint with one coat of primer etc as per site requirement etc as per site requirement. |
| 19 | SITC of two way valve with actuator, temperature controller, transformer, wiring etc as per site requirement complete in all respect. | SITC of two way valve with actuator, temperature controller, transformer, wiring etc as per site requirement complete in all respect. |
| 20 | SITC of actuator, temperature controller, transformer, wiring etc (for two valve) as per site requirement complete in all respect. | SITC of actuator, temperature controller, transformer, wiring etc (for two valve) as per site requirement complete in all respect. |
| 21 | Supply of High Torque valve actuator, model no. SQL36E110, AC 230+10%/-5%, 50/60Hz, 235VA, 12s/90 deg., ED30%, -20T +70 deg.C, IP 67, SS304 nut-bolt etc compatible with the existing BMS software including servicing of inline butterfly valve, dismantling of old valve & actuator | Supply of High Torque valve actuator, model no. SQL36E110, AC 230+10%/-5%, 50/60Hz, 235VA, 12s/90 deg., ED30%, -20T +70 deg.C, IP 67, SS304 nut-bolt etc compatible with the existing BMS software including servicing of inline butterfly valve, dismantling of old valve & actuator |
| 22 | Installation alongwith the BMS configration, testing and commissioning of above valve | Installation alongwith the BMS configration, testing and commissioning of above valve |
| 23 | Providing and fixing of 1200CFM fan coil unit with 4-6 row chilled water coil, other accessories etc | Providing and fixing of 1200CFM fan coil unit with 4-6 row chilled water coil, other accessories etc |
| 24 | Providing and fixing of 1000CFM fan coil unit with 4-6 row chilled water coil other accessories etc | Providing and fixing of 1000CFM fan coil unit with 4-6 row chilled water coil other accessories etc |
| 25 | Providing and fixing of double skin 2000CFM fan coil unit with 4-6 row chilled water coil other accessories etc | Providing and fixing of double skin 2000CFM fan coil unit with 4-6 row chilled water coil other accessories etc |
| 26 | Providing and fixing of double skin 3000CFM fan coil unit with 4-6 row chilled water coil other accessories etc | Providing and fixing of double skin 3000CFM fan coil unit with 4-6 row chilled water coil other accessories etc |
| 27 | Providing and applying the Duco paint of the approved shade with two or more coats with all materials and tools etc | Providing and applying the Duco paint of the approved shade with two or more coats with all materials and tools etc |
| 28 | Dismantling & removal of following capacities Air Handling Units alongwith PUF injected cabinets, blower, motors, evaporators pads, cooling coils, pulley drives, belts etc, disconnecting of metallic connections, ducts, canvass connections, chilled water pipes, Humidifier pipes, other accessories, electrical cables, control cables, BMS cables/wires, earthing strips/wires etc connected with outlived AHU. The job includes complete dismantling & removal of APU/AHU with lifting & shifting as per direction of Engineer-in-charge i/c crane charges, heavy labour, chain pulley blocks etc as required. | Dismantling & removal of following capacities Air Handling Units alongwith PUF injected cabinets, blower, motors, evaporators pads, cooling coils, pulley drives, belts etc, disconnecting of metallic connections, ducts, canvass connections, chilled water pipes, Humidifier pipes, other accessories, electrical cables, control cables, BMS cables/wires, earthing strips/wires etc connected with outlived AHU. The job includes complete dismantling & removal of APU/AHU with lifting & shifting as per direction of Engineer-in-charge i/c crane charges, heavy labour, chain pulley blocks etc as required. |
| 29 | Dismantling & removal of following capacities Exhaust Air Units alongwith PUF injected cabinets, blower, motors, pulley drives, belts etc, disconnecting of metallic connections, ducts, canvass connections, other accessories, electrical cables, control cables, BMS cables/wires, earthing strips/wires etc connected with outlived EA Units. The job includes complete dismantling & removal of EA Units with lifting & shifting as per direction of Engineer-in-charge i/c, crane charges, heavy labour, chain pulley blocks etc as required. | Dismantling & removal of following capacities Exhaust Air Units alongwith PUF injected cabinets, blower, motors, pulley drives, belts etc, disconnecting of metallic connections, ducts, canvass connections, other accessories, electrical cables, control cables, BMS cables/wires, earthing strips/wires etc connected with outlived EA Units. The job includes complete dismantling & removal of EA Units with lifting & shifting as per direction of Engineer-in-charge i/c, crane charges, heavy labour, chain pulley blocks etc as required. |
| 30 | SITC of factory built multistage air processing unit/ AHU of following capacity constructed out of 270 zinc coated, 0.80 mm thick pre-coated GP sheet from outer side and B161shall have seperate section of blower, CHW coils, celldeck pad, filters etc. Casing shall be of non - skeleton construction with thermal break profile AHU complete with backward curved aerofoil blade plug fan direct driven type alongwith energy efficient motor suitable for operations on 415 volts + 5 volts, 50 Hz, 3 phase AC supply, compatible with VFD arrangement, chilled water cooling coils and copper tubes, pre-filter EU-4 (box type) on common frame, drain connections with stainless steel drain tray and necessary vibration isolator to avoid any vibration, connecting flanges including making construction of foundation blocks etc including connecting with AHU motors etc as required | SITC of factory built multistage air processing unit/ AHU of following capacity constructed out of 270 zinc coated, 0.80 mm thick pre-coated GP sheet from outer side and B161shall have seperate section of blower, CHW coils, celldeck pad, filters etc. Casing shall be of non - skeleton construction with thermal break profile AHU complete with backward curved aerofoil blade plug fan direct driven type alongwith energy efficient motor suitable for operations on 415 volts + 5 volts, 50 Hz, 3 phase AC supply, compatible with VFD arrangement, chilled water cooling coils and copper tubes, pre-filter EU-4 (box type) on common frame, drain connections with stainless steel drain tray and necessary vibration isolator to avoid any vibration, connecting flanges including making construction of foundation blocks etc including connecting with AHU motors etc as required |
| 31 | Supply, Installation, testing & commissioning of following capacity floor mounted/ tailor made design floor mounted/ceiling suspended type double skin exhaust air unit fabricated out of 0.80mm thick GI pre-coated sheet on outer side and 0.80mm thick GI plain sheet on inner side having PUF injected insulation with 25mm thickness density not less than 32 kg/m3, sand witched between GI sheet panel for acoustic thermal application comprising of centrifugal forward curved DIDW Blowers, TEFC weather proof motor of IP-55 class F insulation, EFF 1, Direct/Belt drive and pulley mounted on motor and fan shaft, belt guard, motor & fan mounted on common base plate/suitable arrangement. Fan assembly shall be statically and dynamically balanced. Eurovent approved unit complete as per specifications, this item also includes pre-filter & carbon filters including making construction of foundation blocks/MS frame as required etc including connecting with AHU motors etc as required. | Supply, Installation, testing & commissioning of following capacity floor mounted/ tailor made design floor mounted/ceiling suspended type double skin exhaust air unit fabricated out of 0.80mm thick GI pre-coated sheet on outer side and 0.80mm thick GI plain sheet on inner side having PUF injected insulation with 25mm thickness density not less than 32 kg/m3, sand witched between GI sheet panel for acoustic thermal application comprising of centrifugal forward curved DIDW Blowers, TEFC weather proof motor of IP-55 class F insulation, EFF 1, Direct/Belt drive and pulley mounted on motor and fan shaft, belt guard, motor & fan mounted on common base plate/suitable arrangement. Fan assembly shall be statically and dynamically balanced. Eurovent approved unit complete as per specifications, this item also includes pre-filter & carbon filters including making construction of foundation blocks/MS frame as required etc including connecting with AHU motors etc as required. |
| 32 | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastomeric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastomeric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above |
| 33 | Supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class '0' applied by suiatable adhesive, as per specifications and as required complete in all respect. | Supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class '0' applied by suiatable adhesive, as per specifications and as required complete in all respect. |
| 34 | Supplying, fixing, testing and commissioning of following valve, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per site requirement. | Supplying, fixing, testing and commissioning of following valve, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per site requirement. |
| 35 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required |
| 36 | Providing & fixing in position the mercury in glass industrial type thermometers. | Providing & fixing in position the mercury in glass industrial type thermometers. |
| 37 | Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C'class along with necessary clamps, vibration isolators and fittings such as bends,tees etc. but excluding 225 DELHI SCHEDULE OF RATES (E&M)-2025 valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above | Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C'class along with necessary clamps, vibration isolators and fittings such as bends,tees etc. but excluding 225 DELHI SCHEDULE OF RATES (E&M)-2025 valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above |
| 38 | BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating asspecified. | BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating asspecified. |
| 39 | NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16pressure rating as specified | NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16pressure rating as specified |
| 40 | Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required. | Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required. |
| 41 | Supplying, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to controlsystem. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum | Supplying, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to controlsystem. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum |
| 42 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. |
| 43 | Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room | Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room |
| 44 | Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. | Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. |
| 45 | Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. | Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. |
| 46 | Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. | Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. |
| 47 | Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/cum, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. | Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/cum, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. |
| 48 | Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cellNitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required | Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cellNitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required |
| 49 | Providing and fixing of 15 mm thick cross link polythyline (XLP/XLPE) insulation for ducting, main plenum and supply duct i/c cleaning of duct, cutting and pasting of (XLP/XLPE) with the help of Adhesive (SR 505) and 100 mm adhesive based nitrile tape for making the joint etc complete as per relevant IS and site condition. | Providing and fixing of 15 mm thick cross link polythyline (XLP/XLPE) insulation for ducting, main plenum and supply duct i/c cleaning of duct, cutting and pasting of (XLP/XLPE) with the help of Adhesive (SR 505) and 100 mm adhesive based nitrile tape for making the joint etc complete as per relevant IS and site condition. |
| 50 | Supplying, cutting and fixing of plain aluminum sheet of 26 gauge thick for inner/ outer ducts insulated ducting from unit to complete insulated ducting including hardwares such as nut bolts etc. The item includes the cost of scaffolding (Nothing shall be paid extra on account of necessary shifting and scaffolding etc). | Supplying, cutting and fixing of plain aluminum sheet of 26 gauge thick for inner/ outer ducts insulated ducting from unit to complete insulated ducting including hardwares such as nut bolts etc. The item includes the cost of scaffolding (Nothing shall be paid extra on account of necessary shifting and scaffolding etc). |
| 51 | Providing and Applying FRP Lining/Coating 1-2 on Ducting as per requirement in AHU room and other specified area`s etc as required. | Providing and Applying FRP Lining/Coating 1-2 on Ducting as per requirement in AHU room and other specified area`s etc as required. |
| 52 | Providing and applying harder 1-2 (two-three layers of approved colour shed) with fibre mesh on insulated pipeline up to 200 mm dia pipe as per requirement in AHU room and other specified area, etc, as required. | Providing and applying harder 1-2 (two-three layers of approved colour shed) with fibre mesh on insulated pipeline up to 200 mm dia pipe as per requirement in AHU room and other specified area, etc, as required. |
| 53 | Supply, installation, testing and commissioning of MV Panel Boards cubical type, compartmentalised design fabricated from 2 mm/ 1.6 mm thick CRCA sheet having necessary cable alleys, powder coated through nine tank process facility for pricking and degreasing, dust and vermin proof, suitable for operation on 440 V 3 phase, 50 Hz, A.C. supply with necessary MCCBs / MCBs / MPCBs ELECTRICAL WORKS : and other accessories, IP 44 Protection complete in all respects including internal wiring, labels, ferrules, cable termination, gland plates, earth terminals, painting etc. conforming to specifications. All MCCB shall be with Rotary handle and pad locking arrangements complete with incoming and outgoing feeders and accessories as described below:Note:- i). Wall mounted/ floor frame arrangement is included in the scope of work.ii). Panel shall be design as per site requirement, noting shall be paid extra on account of change in outgoing switchgears nos. & ratings but not change main incomer capacity. Bidder shall access the site condition and quote accordingly. | Supply, installation, testing and commissioning of MV Panel Boards cubical type, compartmentalised design fabricated from 2 mm/ 1.6 mm thick CRCA sheet having necessary cable alleys, powder coated through nine tank process facility for pricking and degreasing, dust and vermin proof, suitable for operation on 440 V 3 phase, 50 Hz, A.C. supply with necessary MCCBs / MCBs / MPCBs ELECTRICAL WORKS : and other accessories, IP 44 Protection complete in all respects including internal wiring, labels, ferrules, cable termination, gland plates, earth terminals, painting etc. conforming to specifications. All MCCB shall be with Rotary handle and pad locking arrangements complete with incoming and outgoing feeders and accessories as described below:Note:- i). Wall mounted/ floor frame arrangement is included in the scope of work.ii). Panel shall be design as per site requirement, noting shall be paid extra on account of change in outgoing switchgears nos. & ratings but not change main incomer capacity. Bidder shall access the site condition and quote accordingly. |
| 54 | Supply, installation, testing and commissioning of MV Panel Boards cubical type, compartmentalised design fabricated from 2 mm/ 1.6 mm thick CRCA sheet having necessary cable alleys, powder coated through nine tank process facility for pricking and degreasing, dust and vermin proof, suitable for operation on 440 V 3 phase, 50 Hz, A.C. supply with necessary MCCBs / MCBs / MPCBs ELECTRICAL WORKS : and other accessories, IP 44 Protection complete in all respects including internal wiring, labels, ferrules, cable termination, gland plates, earth terminals, painting etc. conforming to specifications. All MCCB shall be with Rotary handle and pad locking arrangements complete with incoming and outgoing feeders and accessories as described below:Note:-i). Wall mounted/ floor frame arrangement is included in the scope of work.ii). Panel shall be design as per site requirement, noting shall be paid extra on account of change in outgoing switchgears nos. & ratings but not change main incomer capacity. Bidder shall access the site condition and quote accordingly. | Supply, installation, testing and commissioning of MV Panel Boards cubical type, compartmentalised design fabricated from 2 mm/ 1.6 mm thick CRCA sheet having necessary cable alleys, powder coated through nine tank process facility for pricking and degreasing, dust and vermin proof, suitable for operation on 440 V 3 phase, 50 Hz, A.C. supply with necessary MCCBs / MCBs / MPCBs ELECTRICAL WORKS : and other accessories, IP 44 Protection complete in all respects including internal wiring, labels, ferrules, cable termination, gland plates, earth terminals, painting etc. conforming to specifications. All MCCB shall be with Rotary handle and pad locking arrangements complete with incoming and outgoing feeders and accessories as described below:Note:-i). Wall mounted/ floor frame arrangement is included in the scope of work.ii). Panel shall be design as per site requirement, noting shall be paid extra on account of change in outgoing switchgears nos. & ratings but not change main incomer capacity. Bidder shall access the site condition and quote accordingly. |
| 55 | Supply, installation, testing and commissioning of MV Panel Boards cubical type, compartmentalised design fabricated from 2 mm/ 1.6 mm thick CRCA sheet having necessary cable alleys, powder coated through nine tank process facility for pricking and degreasing, dust and vermin proof, suitable for operation on 440 V 3 phase, 50 Hz, A.C. supply with necessary MCCBs / MCBs / MPCBs ELECTRICAL WORKS : and other accessories, IP 44 Protection complete in all respects including internal wiring, labels, ferrules, cable termination, gland plates, earth terminals, painting etc. conforming to specifications. All MCCB shall be with Rotary handle and pad locking arrangements complete with incoming and outgoing feeders and accessories as described below:Note:-i). Wall mounted/ floor frame arrangement is included in the scope of work.ii). Panel shall be design as per site requirement, noting shall be paid extra on account of change in outgoing switchgears nos. & ratings but not change main incomer capacity. Bidder shall access the site condition and quote accordingly. | Supply, installation, testing and commissioning of MV Panel Boards cubical type, compartmentalised design fabricated from 2 mm/ 1.6 mm thick CRCA sheet having necessary cable alleys, powder coated through nine tank process facility for pricking and degreasing, dust and vermin proof, suitable for operation on 440 V 3 phase, 50 Hz, A.C. supply with necessary MCCBs / MCBs / MPCBs ELECTRICAL WORKS : and other accessories, IP 44 Protection complete in all respects including internal wiring, labels, ferrules, cable termination, gland plates, earth terminals, painting etc. conforming to specifications. All MCCB shall be with Rotary handle and pad locking arrangements complete with incoming and outgoing feeders and accessories as described below:Note:-i). Wall mounted/ floor frame arrangement is included in the scope of work.ii). Panel shall be design as per site requirement, noting shall be paid extra on account of change in outgoing switchgears nos. & ratings but not change main incomer capacity. Bidder shall access the site condition and quote accordingly. |
| 56 | Supply, Testing and commissioning of XLPE Copper Conductor and aluminium conductor Armoured control/power cable as per relevant IS/IE rules and site condition of the following size. | Supply, Testing and commissioning of XLPE Copper Conductor and aluminium conductor Armoured control/power cable as per relevant IS/IE rules and site condition of the following size. |
| 57 | Supply, Installation, Testing and Commissioning of Humidification package unit comprising of PAN type heater, control wiring, casing of powder coated MS/GI sheet etc. as required | Supply, Installation, Testing and Commissioning of Humidification package unit comprising of PAN type heater, control wiring, casing of powder coated MS/GI sheet etc. as required |
| 58 | SITC of 36PXD controller | SITC of 36PXD controller |
| 59 | SITC of 12PXD controller | SITC of 12PXD controller |
| 60 | Providing and fixing of 25mm thick double-skinned puff panel with 0.80 mm thick powder-coated GP Sheet from the inner and outer side having density 42 Kg/cum PUF injected, | Providing and fixing of 25mm thick double-skinned puff panel with 0.80 mm thick powder-coated GP Sheet from the inner and outer side having density 42 Kg/cum PUF injected, |
| 61 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 62 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 63 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required |
| 64 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling withM.S. suspenders including bolts & nuts, painting suspenders etc as required. | Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling withM.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 65 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays tee with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling withM.S. suspenders including bolts & nuts, painting suspenders etc as required. | Supplying and installing following size of perforated painted with powder coating M.S. cable trays tee with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling withM.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 66 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross member with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling withM.S. suspenders including bolts & nuts, painting suspenders etc as required. | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross member with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling withM.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 67 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling withM.S. suspenders including bolts & nuts, painting suspenders etc as | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling withM.S. suspenders including bolts & nuts, painting suspenders etc as |
| 68 | Strip HeatersSupplying, Installation, Testing and Commissioning of Electric Strip Heaters of capacities (3 KW each set of Heaters in Plenum/Return air chamber- 2 Nos of AHU`s) for monsoon reheat and winter heating arranged in banks complete with cooling / heating thermostats (TH), Humidistats (HU), safety stats (SF) etc. as per details given below for AHUs/ plenums complete with interwiring (but excluding cable and connection from AHU switch board) and connections etc. complete as required and as per specifications. - | Strip HeatersSupplying, Installation, Testing and Commissioning of Electric Strip Heaters of capacities (3 KW each set of Heaters in Plenum/Return air chamber- 2 Nos of AHU`s) for monsoon reheat and winter heating arranged in banks complete with cooling / heating thermostats (TH), Humidistats (HU), safety stats (SF) etc. as per details given below for AHUs/ plenums complete with interwiring (but excluding cable and connection from AHU switch board) and connections etc. complete as required and as per specifications. - |
| 69 | Supplying, installation, testing and commissioning of DP switch compatible with existing BMS system alongwith the all accessories etc as per site requirement completed in all respect. | Supplying, installation, testing and commissioning of DP switch compatible with existing BMS system alongwith the all accessories etc as per site requirement completed in all respect. |
| 70 | Supplying, installation, testing, commissioning and configuration of digital display unit (temp., RH, Room pressure) compatible and configuration with existing BMS system alongwith the all accessories etc as per site requirement completed in all respect. | Supplying, installation, testing, commissioning and configuration of digital display unit (temp., RH, Room pressure) compatible and configuration with existing BMS system alongwith the all accessories etc as per site requirement completed in all respect. |
| 71 | Supplying, installation, testing and commissioning of following size SS304 ball valve with SS304 nipple at both end as per site requirement completed in all respect. | Supplying, installation, testing and commissioning of following size SS304 ball valve with SS304 nipple at both end as per site requirement completed in all respect. |
| 72 | Supply, installation, testing and commissioning of ISI mark cpvc valve and pipe with other accessories i.e elbow, bend, tee , cooper connection/socket etc heavy duty of following size | Supply, installation, testing and commissioning of ISI mark cpvc valve and pipe with other accessories i.e elbow, bend, tee , cooper connection/socket etc heavy duty of following size |
| 73 | Supply, installation, testing and commissioning of 4-to 6 Row deep cooling coil made of 0.4mm thick & ½’’ dia. (Hair Pin Bend Copper Tubes) copper tube, aluminium Fins, 37gauge & 11-13 fins per inch, MS coil header, Galvanized coil casing, suitable size of SS drain pan, ceiling compound etc complete in all respect including providing of canvas connection, insulation, cutting-welding works etc & similar to existing above 3000CFM but below 4000CFM including leak testing and pressure testing at 300 PSI. I/C removal of damaged cooling coil from AHU, cutting-welding, insulation, canvas connections etc. and complete as per site requirement. The cooling coil should be certified by AHRI or ASHRAE. | Supply, installation, testing and commissioning of 4-to 6 Row deep cooling coil made of 0.4mm thick & ½’’ dia. (Hair Pin Bend Copper Tubes) copper tube, aluminium Fins, 37gauge & 11-13 fins per inch, MS coil header, Galvanized coil casing, suitable size of SS drain pan, ceiling compound etc complete in all respect including providing of canvas connection, insulation, cutting-welding works etc & similar to existing above 3000CFM but below 4000CFM including leak testing and pressure testing at 300 PSI. I/C removal of damaged cooling coil from AHU, cutting-welding, insulation, canvas connections etc. and complete as per site requirement. The cooling coil should be certified by AHRI or ASHRAE. |
| 74 | Supply, installation, testing and commissioning of 4 Row deep cooling coil made of 0.4mm thick & ½’’ dia. (Hair Pin Bend Copper Tubes) copper tube, aluminium Fins, 37gauge & 11-13 fins per inch, MS coil header, Galvanized coil casing, suitable size of SS drain pan, ceiling compound etc complete in all respect including providing of canvas connection, insulation, cutting-welding works etc & similar to existing above 1500CFM but below 3000CFM including leak testing and pressure testing at 300 PSI. I/C removal of damaged cooling coil from AHU, cutting-welding, insulation, canvas connections etc. and complete as per site requirement. The cooling coil should be certified by AHRI or ASHRAE. | Supply, installation, testing and commissioning of 4 Row deep cooling coil made of 0.4mm thick & ½’’ dia. (Hair Pin Bend Copper Tubes) copper tube, aluminium Fins, 37gauge & 11-13 fins per inch, MS coil header, Galvanized coil casing, suitable size of SS drain pan, ceiling compound etc complete in all respect including providing of canvas connection, insulation, cutting-welding works etc & similar to existing above 1500CFM but below 3000CFM including leak testing and pressure testing at 300 PSI. I/C removal of damaged cooling coil from AHU, cutting-welding, insulation, canvas connections etc. and complete as per site requirement. The cooling coil should be certified by AHRI or ASHRAE. |
| 75 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 76 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required |
| 77 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
| 78 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 79 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 80 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender