Educational and Research Institute Government Departments Closing in 10 days TDR #56897946

Tender For Comprehensive Annual Maintenance Contract For Electrical Installations At Cmpdi Exploration C , Kosala, Dist. - Angul, Odisha, For A Period Of 02 Years

Issued by Government Departments · Anugul, Odisha
Tender Value
23.89 Lakhs
Estimated cost
Bid Submission
18 Aug 2026
10 days left
EMD
29900
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Anugul → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Comprehensive Annual Maintenance Contract For Electrical Installations At Cmpdi Exploration C , Kosala, Dist. - Angul, Odisha, For A Period Of 02 Years

BOQ

Name of Work:- Comprehensive Annual Maintenance Contract for electrical installations at CMPDI Exploration c , Kosala, Dist. – Angul, Odisha, for a period of 02 years
Sl. No. Item Description
1Wiring for circuit/submain wiring alongwith earth wire with the 2x1.5 sq.mm + 1X1.5 sq.mm of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
2Wiring for circuit/submain wiring along with earth wire with 2x2.5 sq.mm + 1x2.5 sq.mm of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
3Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps,bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished and finished paint as required .
4Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/steel tubular/ rail pole etc. as required.
5Supplying and erection of 75 mm X 90 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required .
6Supplying and erection of 100 mm X 80 mm pin insulator with G. I. spindle, nuts and straps etc. as required .
7Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including binding etc. as required.
8Wiring for circuit/submain wiring alongwith earth wire with 2x4 sq.mm + 1x4 sq.mm of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
9Wiring for circuit/submain wiring alongwith earth wire with 2x6 sq.mm + 1x6 sq.mm of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
10Supply of 25 mm dia ISI marked PVC conduit
11Wiring for circuit/submain wiring alongwith earth wire with 2x10 sq.mm + 1x6 sq.mm of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
12Supplying and drawing of 3x1.5 sq.mm FR PVC insulated copper conductor single core cable in the existing surface/recessed steel / PVC conduit as required.
13Supplying and drawing of 3x2.5 sq.mm FR PVC insulated copper conductor single core cable in the existing surface/recessed steel / PVC conduit as required.
14Supplying and fixing of 5/6 amps switch on the existing switch box/cover including connections etc. as required
15Supplying and fixing of 3 pin 5/6 amps Socket Outlet on the existing switch box/cover including connections etc. as required
16Supplying and fixing of 15/16 amps switch on the existing switch box/cover including connections etc. as required
17Supplying and fixing of 3 pin 15/16 amps socket outlet on the existing switch box/cover including connections etc. as required
18Supplying and fixing Bell push switch on the existing switch box/cover including connections etc. as required
19Supplying and fixing of call bell/buzzer suitable for single phase, 230 volts, complete as required.
20Wiring for light point / fan point/exhaust fan /call bell point with 1.5 sqmm FR PVC insulated,copper conductor, single core cable in surface/recessed steel / PVC conduit , with piano type switch , phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc as required. Group A - 3 mtrs
21Wiring for light point / fan point/exhaust fan /call bell point with 1.5 sqmm FR PVC insulated,copper conductor, single core cable in surface/recessed steel / PVC conduit , with piano type switch , phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc as required. Group B - 4 mtrs
22Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required.
23Supply and fixing 5A to 32 A rating 240/415V ,10 kA \\"C\\"- curve miniature circuit breaker suitable for inductive load for Single pole in the existing MCB DBs complete with connections , testing , commissioning etc. as required.
24Supply and fixing 5A to 32 A rating 240/415V ,10 kA \\"C\\"- curve miniature circuit breaker suitable for inductive load for Double pole in the existing MCB DBs complete with connections , testing , commissioning etc. as required.
25Supply and fixing 5A to 32 A rating 240/415V ,10 kA \\"C\\"- curve miniature circuit breaker suitable for inductive load for Triple Pole and Neutral in the existing MCB DBs complete with connections , testing , commissioning etc. as required.
26Supplying, erecting & marking FP MCB 40A to 63A, with rated short- circuit breaking capacity (Icn) 10 kA in provided distribution board as per specification no. SW-MCB
27Supplying and fixing 40 A ,double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCBDBcomplete with connections, testing and commissioning etc. as required
28Providing and fixing 36 kA, 200 amps four pole rating and breaking capacity and pole MCCB with thermomagnatic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel ,making connections etc. as required .
29Providing and fixing 50 kA, 400 amps four pole rating and breaking capacity and pole MCCB with thermomagnatic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel ,making connections etc. as required .
30Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable, 1100 V, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
31Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
32Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
33Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
34Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for 3½ x 35 sq mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
35Providing servicing of 1.5/2 TR capacity split/ window air conditioning unit complete with all necessary material. Job includes checking of performance of unit, cleaning of filters of indoor unit, cleaning of outdoor unit with blower, checking of electrical connection of indoor as well as outdoor unit and submitting report to Engineer incharge.
36Providing vaccumising the air conditioner system and charging with R-22 refrigerant for air conditioning unit
37Providing replacement of unserviceable running / Starting capacitor for A/C unit
38Supplying and installing of new fan motor for condensor for air conditioning unit
39Replacing the existing ball bearing of table/ cabin/ pedestal/ ceiling/ exhaust fan complete with alignment of shaft & testing the same
40Replacing the existing bush / rubber with ring and washers of table/ cabin/ pedestal/ ceiling/ exhaust fan complete with alignment of shaft & testing the same.
41Rewinding the motor of table / pedestal / wall bracket / cabin fans of all type and makes including minor repairs lubricating of ball bearings & bush bearing, replacing condenser, screws etc. & testing for original speed and consumption with guarantee for 1 year including transportation from site and back.
42Rewinding the motor of the ceiling fan 1200 mm / 1400 mm of all types and makes and overhauling including minor repairs lubricating of ball bearings & bush bearing, replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year
43Rewinding the motor of the exhaust fan 900 / 1400 RPM 300 mm of all types and makes and overhauling including minor repairs, lubricating of ball bearings & bush bearing, replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year
44Supplying and erecting integrated LED street light fitting 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG ODF/SL
45Earthing with GI earth plate 600mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required
46Supply of aluminium binding wire
47Supply and fixing phase separator in overhead line
48Supply of 55 mm2 All alloy aluminum conductor AAAC
49Trimming of tree branches near the overhead line in camp premises.
50Supply and fixing of 10 watt LED tube light batten (make wipro ,bajaj ,philips or equivelent.)
51Supply and fixing of 20 watt LED tube light batten (make wipro ,bajaj ,philips or equivelent.)
52Supply and fixing of R06 type (AA), 1.5V Battery
53Supply and fixing of R03 type(AAA), 1.5V Battery
54Supply and fixing of 4 pole 40 Amp.,415 volts onload changeover switch with enclosure
55Supply and fixing of PVC board of 7\\"x4\\" sizes with backelite sheet on top.
56Supply and fixing of PVC board of 8\\"x6\\" sizes with backelite sheet on top.
57Supply and fixing of bolted fuse link (16 Amp. To 32 Amp)
58Supply and fixing of fuse holders 20 Amp.
59Supply and fixing of fuse holders 32 Amp.
60Electrician for maintenance - comprising of Electrical fault rectification, Generator operation, substation manning, etc. ( detail scope provided in NIT) by deployment of two electrician with valid wireman licence per shift for 2 shifts per day.
61Reparing and servicing of 3 phase 2 HP submersible pumpset installed in CMPDI Campus - Rewinding work
62Reparing and servicing of 3 phase 2 HP submersible pumpset installed in CMPDI Campus - lathe work for shaft repair
63Reparing and servicing of 3 phase 2 HP submersible pumpset installed in CMPDI Campus - Motor Bush
64Reparing and servicing of 3 phase 2 HP submersible pumpset installed in CMPDI Campus - Pump impeller
65Reparing and servicing of 3 phase 2 HP submersible pumpset installed in CMPDI Campus - Pump Diffuser
66Reparing and servicing of 3 phase 2 HP submersible pumpset installed in CMPDI Campus - Pump shaft
67Reparing and servicing of 3 phase 2 HP submersible pumpset installed in CMPDI Campus - Pump coupling
68Reparing and servicing of 3 phase 2 HP submersible pumpset installed in CMPDI Campus - Installation
69Servicing and Maintenance of DG set 1 x 25 KVA - Air Filter
70Servicing and Maintenance of DG set 1 x 25 KVA - Fuel filter pre element
71Servicing and Maintenance of DG set 1 x 25 KVA - Element fuel Micro Filter
72Servicing and Maintenance of DG set 1 x 25 KVA - Lub Oil Filter element
73Servicing and Maintenance of DG set 1 x 25 KVA - Pre-mix 10 ltr Pack
74Servicing and Maintenance of DG set 1 x 25 KVA - Lub oil 20Ltr Pack
75Servicing and Maintenance of DG set 1 x 25 KVA - Coggled belt
76Servicing and Maintenance of DG set 1 x 25 KVA - PDC rocker cover gasket
77Servicing and Maintenance of DG set 1 x 25 KVA - packing & forwarding charges
78Servicing and Maintenance of DG set 1 x 25 KVA - Servicing of DG set such as replacement of spares, tuning and adjustment & testing
79Repairing of 11/.415 kV Transformer - Topping-up of transformer with new transformer oil (Chargable as per actual )
80Providing, fixing new battery along with buy back of old battery of rating 12V 120 AH for DG set
81Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56897946
AUTHORITY Government Departments
TENDER VALUE 23.89 Lakhs
LAST DATE 18-08-2026
Authority
Authority Name Central Mine Planning And Design Institute Limited
Work Description Tender for Comprehensive Annual Maintenance Contract For Electrical Installations At Cmpdi Exploration C , Kosala, Dist. - Angul, Odisha, For A Period Of 02 Years
Basic Detail
Tender No CMPDI/RI-VII/BBSR/EnM/2026/907
Bidding Type Tender
Location
City Anugul
State Odisha
Key Dates
Publish Date 07 Aug 2026
Submission Date 18 Aug 2026
Open Date 19 Aug 2026
Finance
Tender Value 23.89 Lakhs
Tender Fee Ref. Documents
EMD 29900
Exemption Not Available
Document List
7da0ce47-d2e9-4e0d-bf5f-f1d3da58f947.html
BOQ_376209.xls
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Aug 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

7da0ce47-d2e9-4e0d-bf5f-f1d3da58f947.html

xls

BOQ_376209.xls

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender