Educational and Research Institute Government Departments Closing in 0 days TDR #56897456

Tender For Electrification Work Of Mahi Hostel At Mahila Engineering College Ajmer

Issued by Government Departments · Ajmer, Rajasthan
Tender Value
12 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
0 days left
EMD
24000
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ajmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Electrification Work Of Mahi Hostel At Mahila Engineering College Ajmer

BOQ

Name of Work:- Electrification Work of Mahi Hostel at Mahila Engineering College Ajmer
Sl. No. Item Description
1Wiring of light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq.mm FR PVC insulated earth conductor (IS:694) on surface ISI marked MMS (IS:9537 P-III) PVC conduit & accessories, 1.2mm thick Hot Dipped GI MS box with earth terminal, 6A switch, 3 pin ceiling rose/holder/3-way connector, 3mm thick ISI marked phenolic laminated sheet (IS:2036-1995), screws, cup washers, making connections, testing etc. as required. Short point (up to 3 mtr.)
2Wiring of light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq.mm FR PVC insulated earth conductor (IS:694) on surface ISI marked MMS (IS:9537 P-III) PVC conduit & accessories, 1.2mm thick Hot Dipped GI MS box with earth terminal, 6A switch, 3 pin ceiling rose/holder/3-way connector, 3mm thick ISI marked phenolic laminated sheet (IS:2036-1995), screws, cup washers, making connections, testing etc. as required.Medium point (up to 6 mtr.)
3Wiring of light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq.mm FR PVC insulated earth conductor (IS:694) on surface ISI marked MMS (IS:9537 P-III) PVC conduit & accessories, 1.2mm thick Hot Dipped GI MS box with earth terminal, 6A switch, 3 pin ceiling rose/holder/3-way connector, 3mm thick ISI marked phenolic laminated sheet (IS:2036-1995), screws, cup washers, making connections, testing etc. as required. Long point (up to 10 mtr.)
4Wiring of twin control light point with 1.5 sq.mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq.mm FR PVC insulated earth conductor (IS:694) on surface ISI marked MMS (IS:9537 P-III) PVC conduit & accessories, 2 Nos. 1.2mm thick Hot Dipped GI MS box, 2 Nos. 6A two way switch, ceiling rose/holder, phenolic laminated sheet, screws, making connections, testing etc. as required.Long point (up to 10 mtr.)
5Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq.mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and earth conductor (IS:694) on surface ISI marked MMS (IS:9537 P-III) PVC conduit & accessories, 1.2mm thick Hot Dipped GI MS box, 6A switch, 3/5 pin 6A socket, phenolic laminated sheet, screws, making connections, testing etc. as required.On board
6S&F following sizes (dia.) of ISI marked MMS (IS:9537 P-III) PVC conduit along with ISI marked (IS:3419-1988) accessories as required on surface including heavy duty saddles with base at spacing of 0.60 mtr. etc. as required.20 mm
7S&F following sizes (dia.) of ISI marked MMS (IS:9537 P-III) PVC conduit along with ISI marked (IS:3419-1988) accessories as required on surface including heavy duty saddles with base at spacing of 0.60 mtr. etc. as required.32 mm
8Supplying and laying FR PVC insulated & unsheathed flexible copper conductor with ISI marked (IS:694) and as per IS 8130:2013 of 1.1 kV grade in existing surface or recessed PVC/MS conduit/casing capping, making connections with Copper Lugs, Ferrules, testing etc. as required.3 x 1.5 sq.mm
9Supplying and laying FR PVC insulated & unsheathed flexible copper conductor with ISI marked (IS:694) and as per IS 8130:2013 of 1.1 kV grade in existing surface or recessed PVC/MS conduit/casing capping, making connections with Copper Lugs, Ferrules, testing etc. as required..2 x 2.5 sq.mm + 1 x 1.5 sq.mm
10Supplying and laying FR PVC insulated & unsheathed flexible copper conductor with ISI marked (IS:694) and as per IS 8130:2013 of 1.1 kV grade in existing surface or recessed PVC/MS conduit/casing capping, making connections with Copper Lugs, Ferrules, testing etc. as required.3 x 1.5 sq.mm
11Supply and Laying ISI marked P.V.C. insulated submersible cable conforming to (IS:694) and as per IS 8130:2013 of 1.1 kV grade in existing pipe/open trench/Cable tray/on surface including making connection etc. as required.
12Providing & Fixing of 240/415V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic), 4KV impulse withstand voltage, ISI marked IS 8828(1996)/conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism, energy limiting class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20A, 10,000 upto 63A, 5000 for 80A & above rating including making connections, testing etc. as required.Single Pole MCB (With B/C curve) — 6A to 32A rating
13Providing & Fixing of 240/415V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic), 4KV impulse withstand voltage, ISI marked IS 8828(1996)/conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism, energy limiting class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20A, 10,000 upto 63A, 5000 for 80A & above rating including making connections, testing etc. as required.Four Pole MCB (With B/C curve) — 50/63A rating
14Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal/Glazed/Acrylic) Distribution board with Metal end box made out from Galvanized steel/CRCA sheet, powder coated conforming to IS-8623-1&3/IEC 61439-1&3, complete with 100 amp. insulated copper bus bar/shorting link, brass neutral link with shrouds, brass earth link, door earthing arrangement, color coded interconnecting wire set of minimum 10.0 sq.mm and din bar, masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required.Metal door (Single phase) IK-09 and IP-43 with Metal end box — 12 Way
15Metal door (Three phase) IK-09 and IP-43 with Metal end box — 4 Way (8 incomer + 12 Outgoing)
16Providing & Fixing of IS 11037 marked non modular socket size flush type 100W rotary minimum 5-step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate material including making connection, testing etc. as required.
17Providing & Fixing of IS:1293 marked modular type lockable feature socket with CM/L no. printed duly made out of unbreakable and fire retardant virgin polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc. as required.6/16A shuttered socket
18Providing & Fixing of following modular accessories, made out of unbreakable and fire retardant virgin polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc. as required.Modular MCB 6A to 32A SP
19Providing and fixing of power plug point with non modular accessories with Galvanized box of 1.2mm thick with earth terminal, 3mm thick phenolic laminated sheet (IS: 2036-1995) cover including cost of 16 amp. Switch (IS: 3854) and 3/6 pin 16 amp. Socket outlet, making connection, testing etc. as required.
20Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable conforming to IS: 7098 P-I of 1.1KV with H4-Grade electrolytic aluminium conductor conforming to IS 8130 of purity >99.6%, round/flat strip armouring of cables, Inner/outer sheath conforming to IS: 5831 in existing RCC/Hume/Stoneware/PVC pipe/open duct/cable trench/Cable tray (with cable tie) including testing commissioning etc. as required.16.0 Sq.mm — 4 core
21Supplying and making end termination with heavy aluminium lugs (Pin/ring type) conforming to IS 8309-1993 duly crimped with crimping tool, PVC tape etc. of following size.16.0 sq.mm
22SITC of Copper Bonded rod Earthing with high tensile strength (>600 N/sq.mm) low carbon steel rod molecularly bonded with Copper thickness (250 microns) conforming to UL 467 including: (a) Bore a hole of dia 100mm of required length; (b) Earth enhancing compound 25 kg for 3000 mm, tested from NABL accredited lab for low resistivity (<0.12 Ohm-meter) as per IEC 62561-7; (c) Connect rod with copper strip/conductor with tinned copper/SS304 clamp; (d) Heavy duty weather proof PP earth inspection chamber conforming to IEC 62305 with lockable lid 250mm x 250 to 300mm; (e) Testing of earth resistance to 5 ohms or less. OEM test certificates mandatory.17.2mm thick and 3 Mtr. Long
23Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/soldering/welding, Jointing by overlapping double the width of strip with 2 sets of GI nut bolt & spring washer spaced at 50cm, making connection etc. as required.20mm x 3mm G.I. (Hot Dipped) Strip
24Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity >95% thimble etc. as required.10 SWG G.I. (Hot Dipped) Wire
25Supply & fabrication steel structure with MS channel/angle/joist/ISMB/sheet etc. including welding, rivetting, cutting, nut & bolt, one coat of primer & two coat of enamel paint etc. as required complete in all respect.
26Providing and fixing 1400mm Ceiling Fan — Sweep Size 1400 mm (56 inches), Air Delivery 245 to 270 m3/min (CMM), Rotational Speed 270 to 300 RPM, Power Consumption 75W to 80W, 3 Aerodynamic Blades, Motor Type 100% Copper Winding or Brushless DC (BLDC), BEE 5 Star Rated, including all accessories, making connections, testing etc. as required.
27Providing and fixing Exhaust Fan — Sweep Size 230 mm (9 inches), Air Delivery 510 to 750 m3/hr (CMH), Speed 1,350 to 1,400 RPM, Power Consumption 40W to 50W, Operating Voltage 230V AC Single Phase 50 Hz, 100% copper wound motor, pre-lubricated double ball bearings, integrated rust-free steel bird guards, including all accessories, making connections, testing etc. as required.
28Supplying and fixing of 20W LED Tubelight (Cool Daylight, 6500K), 2000 Lumens (Efficacy 100 lm/W), Voltage Range 140V to 300V AC with 4kV surge protection, Lifespan 25,000 to 50,000 burning hours, Body: Polycarbonate (PC) with aluminium heat sink, BIS Approved, Power Factor 0.9, including all accessories, making connections, testing etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56897456
AUTHORITY Government Departments
TENDER VALUE 12 Lakhs
LAST DATE 17-08-2026
Authority
Authority Name Government Women Engineering College
Work Description Tender for Electrification Work Of Mahi Hostel At Mahila Engineering College Ajmer
Basic Detail
Tender No GWECA/ELECTRICAL ESTATE/2026-27/1052
Bidding Type Tender
Location
City Ajmer
State Rajasthan
Key Dates
Publish Date 07 Aug 2026
Submission Date 17 Aug 2026
Open Date 18 Aug 2026
Finance
Tender Value 12 Lakhs
Tender Fee 1000
EMD 24000
Exemption Available
Document List
04059f7e-305f-40a9-9c8e-282ac5ff5371.html
Annexure.pdf
Bid.pdf
BOQ_1037342.xls
Tendernotice_1 (32).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

04059f7e-305f-40a9-9c8e-282ac5ff5371.html

pdf

Annexure.pdf

pdf

Bid.pdf

xls

BOQ_1037342.xls

pdf

Tendernotice_1 (32).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender