Tender For Certain Repair/ Maintenance Of Day To Day Complaint Of Lt Distribution System, Lt Panels And Allied Works At Ph-I Ph-Ii Areas Under Ge Narangi
Tender Value
49 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
0 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup Metro → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Certain Repair/ Maintenance Of Day To Day Complaint Of Lt Distribution System, Lt Panels And Allied Works At Ph-I Ph-Ii Areas Under Ge Narangi
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 2 | Excavation in trenches n.exc 1.5mtr wide and exc. 1.5m in depth for foundation and getting out in soft/loose soil complete all as specified and as directed. |
| 3 | Supply and spreading clean dry river sand in cable trenches as in cable cushioning complete all as specified and as directed. (Note: Punned thickness shall be measured and paid) |
| 4 | Material and labour for Sub class ‘B’ old size well burnt brick laid flat in trenches over the cable for protection of LT cable complete all as specified and as directed. |
| 5 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and as directed. |
| 6 | Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed. |
| 7 | Taking out old unserviceable UG cable of size 10-16 Sqmm 2/4 core from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid seperately under relavent BoQ items. |
| 8 | Taking out old unserviceable UG cable of size 25-50 Sqmm 3.5 core from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid seperately under relavent BoQ items. |
| 9 | Taking out old unserviceable UG cable of size 70-95 Sqmm 3.5 core from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid seperately under relavent BoQ items. |
| 10 | Taking out old unserviceable UG cable of size 120-185 Sqmm 3.5 core from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid seperately under relavent BoQ items. |
| 11 | Taking out old unserviceable UG cable of size 240-300 Sqmm 3.5 core from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid seperately under relavent BoQ items. |
| 12 | Labour only for laying serviceable UG XLPE cable of size 70 to 95 sqmm, 3.5 core in trenches/ wall/ roof etc. including cutting and jointing through cable jointing kit as required and connecting to the main switches/cut outs MCB/MCCB with necessary lugs after cutting to required length complete all as specified and as directed. NOTE: (a) Serviceable UG XLPE cable shall be obtained from BoQ item No. 9 here-in-before. (b) Excavation and earth work,brick protection, sand cushioning etc. shall be measured and paid seperately under relavent BoQ items. |
| 13 | Labour only for laying serviceable UG XLPE cable of size 120 to 185 sqmm, 3.5 core in trenches/ wall/ roof etc. including cutting and jointing through cable jointing kit as required and connecting to the main switches/cut outs MCB/MCCB with necessary lugs after cutting to required length complete all as specified and as directed. NOTE: (a) Serviceable UG XLPE cable shall be obtained from BoQ item No.10 here-in-before. (b) Excavation and earth work,brick protection, sand cushioning etc. shall be measured and paid seperately under relavent BoQ items. |
| 14 | Labour only for laying serviceable UG XLPE cable of size 240 to 300 sqmm, 3.5 core in trenches/ wall/ roof etc. including cutting and jointing through cable jointing kit as required and connecting to the main switches/cut outs MCB/MCCB with necessary lugs after cutting to required length complete all as specified and as directed. NOTE: (a) Serviceable UG XLPE cable shall be obtained from BoQ item No. 11 here-in-before. (b) Excavation and earth work,brick protection, sand cushioning etc. shall be measured and paid seperately under relavent BoQ items. |
| 15 | Material and labour for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 10 sqmm 4 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed. |
| 16 | Material and labour for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 4 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed. |
| 17 | Material and labour for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 25 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed. |
| 18 | Material and labour for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 50 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed. |
| 19 | Material and labour for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 70 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed. |
| 20 | Material and labour for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 95 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed. |
| 21 | Material and labour for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 120 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed. |
| 22 | Material and labour for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 150 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed. |
| 23 | Material and labour for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 185 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed. |
| 24 | Material and labour for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 300 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed. |
| 25 | Material and labour for Removing electric / mechanical connections of old LT UG cable from MCCB of existing LT Panel of size from 16 sqmm to 95 Sq mm, 3.5 / 4.0 core including cutting/removing the burnt end/ jointed area and after refixing with new aluminium thimble /lugs set , incl covered with proper insulated tape, clamps, nut bolts etc if required etc complete all as specified and as directed.Note : One Panels cable will measured as one Job |
| 26 | Material and labour for Removing electric / mechanical connections of old LT UG cable from MCCB of existing LT Panel of size from 120 sqmm to 300 Sq mm, 3.5 / 4.0 core including cutting/removing the burnt end/ jointed area and after refixing to MCCB/ACB with new aluminium thimble /lugs set , incl covered with proper insulated tape, clamps, nut bolts etc if required etc complete all as specified and as directed..Note : One Panels cable will measured as one Job |
| 27 | Material and labour for taking out the loose or separated Door / canopy / front & back sheet covers for existing the LT panel and refixing the same after welding, provn of nut bolts / hinges if required as per site, proper locking arrangement and fixing of proper earth connection etc complete all as specefied and directed. |
| 28 | Material and labour for replacement of out door panel board canopy door, made CRCA sheet with 3.15 mm thick, duly power coated with removable door hinges, water proof rubber beading and , locking arrangement with SS aldrop & pad lock/ concealed locking arrangement, Danger notice boards, Panel details including gas welding for fixing the door complete all as specefied and directed. |
| 29 | Material and labour for replacement of out door/in door panel board, made CRCA sheet with 2 mm thick, duly notched/punched cavity for operation of switch gear and duly power coated with removable door hinges, water proof rubber beading and , locking arrangement, Danger notice boards, switch gear details including gas cutting & welding for fixing the door complete all as specefied and directed. |
| 30 | Supply and fix in repair danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20 cm size complete all as specefied and directed. Please Enable Macros to View BoQ information |
| 31 | Supply and fix in repair danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20 cm size complete all as specefied and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender