Tender for Provn Of 01 X Covered Vehs Shed For Parking Of 15 X B Vehs & Mt Store Room Of 16 Arty Bde C At Faridkot Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in post holes in soft/loose soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, |
| 2 | M&L for Plain Cement Concrete Type B2 1:2:4 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete.All as specified and directed by engr in charge. |
| 3 | M&L for tubular vertical post, fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections,tubular pole) including distance pieces, cleats etc. |
| 4 | M&L for Roof trusses (framed),trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections,tubular pole) including distance pieces, cleats etc. |
| 5 | S&F Rolled Mild steel Plates (plain or Chequred) channels, square cut or notched, forming holes, with riveted, bolted or welded attachment confirming to Fe 410 - O or Fe 310 - O. |
| 6 | S&F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet (ISI Marked) 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screw all as specified and directed. |
| 7 | M&L for Preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint. |
| 8 | Surface Excavation, not exceeding 30 CM deep and averaging 15cm deep and getting out in soft / loose soil complete All As specified and directed by Engr in Charge. |
| 9 | M&L for broken stone or boulder hardcore of gauge n exc 63mm deposited spread and levelled in layer n exc 10 cm thick watered and rammed to a true surface complete all as specified and directed. |
| 10 | M&L for 100 mm PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregates as in sub base flooring complete all as specified. |
| 11 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete. |
| 12 | S & F Precast kerb stones(factory made) in PCC 1:2 :4 type B-1 incl chamfers, weatherings,throatings etc in smooth finish & set in cement mortar 1:4 on sides of roads including necessary excavation embedding blocks in the ground to depth as directed . |
| 13 | M&L for prperation of newly surfaces of concrete and applying two coat of synthetic enamel paint complete all as specified and directed by Engr-in Charge. |
| 14 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil |
| 15 | M&L PCC 1:4:8 type D2 (using 40mm graded aggregate) in foundation, filling and mass concrete complete all as specified and directed by Engr-in-Charge |
| 16 | M&L for brick work with fly ash bricks (old size bricks) straight or curved on plan exceeding 6m mean radius with old size bricks in wall built in cement mortar (1:6) complete all as specified and directed by Engr-in-Charge |
| 17 | M&L Rendering 15 mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge |
| 18 | M&L Cement concrete 75mm thick type C2, 1:3:6 using 20mm graded aggregate as in plinth protection/path finishing surfaces even and fair (without using extra cement) all as specified and directed by Engr-in-Charge |
| 19 | M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in coping, bed blocks and similar works including slightly rounded or chamfered angles including necessary formwork complete all as specified and directed. |
| 20 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm |
| 21 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point |
| 22 | M&L Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. m |
| 23 | M&L Polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m |
| 24 | M&L preparation of newly plastered or unplastered surfaces of wall and applying two coat of cement base paint over a prime coat complete all as specified and directed by Engr -in - charge. |
| 25 | Point wiring complete with ISI marked 2.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLSH with multistranded copper conductor drawn through & including PVC rigid concealed conduit suitable size with all accessories bend reducers,MS hooks,MS junction boxes,terminal boxes & including modular steel terminal boxes factory made and cover modular plate with frame suitable for (modular switches, sockets, fan regulator) & including 2.5 sqmm copper conductor as earth continuity to connect common earth dolly complete for the following all as specified and as directed. (a) One light point/Fan point/Exhaust point controlled by one way switch |
| 26 | (b) One three pin socket out let 5 amps on the same board with other switches |
| 27 | (c) One 3 pin, 5A switch socket outlet point on independent board |
| 28 | All as per item no. 25 here-in-before but with 4 sqmm cable for 1No 16 amps socket outlet point on independent board including 4 sqmm PVC insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor. |
| 29 | Supply and fixing of LED tube light fiting 20W, 230 V, wall mounted LED batten with polycarbonate housing & integrated electronic driver and including connections up with copper conductor wire with suitable size as per specification and directed by Engineer-in-chrg. |
| 30 | M&L ceiling rose 3 terminal / PVC / polycarbonate isolated body |
| 31 | S&F Moduler switch single pole 1 way 6 amps,1 Module 230 volt AC supply complete all as specified and directed by Engr-in-Charge. |
| 32 | S&F Moduler socket two in one 2/3 Pin 6 Amps 2 Module 230 volt AC supply complete all as specified and directed by Engr-in-Charge. |
| 33 | S&F Moduler type switch single pole 1 way 16 amps,1 Module 230 volt AC supply complete all as specified and directed. |
| 34 | S&F Moduler socket 2/3 Pin 16 Amps 2 Module 230 volt AC supply complete all as specified and directed by Engr-in-Charge. |
| 35 | M&L submain wiring with two single core PVC FRLSH insulated copper conductor 4 sqmm and same 4 sqmm for continuous earth wire drawn in and including concealed PVC conduit complete with all accessories as specified and directed by Engr-in-Charge. Note: Cost of earth wire including in sub main wiring. |
| 36 | Supply and fixing amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of SPN 32 AMP and current carrying capacity in the MCB DB complete with connection all as specified and directed. |
| 37 | Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection all as specified and directed. |
| 38 | S&F sheet metal enclosure for DB's SPN 230 volts 8 way double door complete all as specified and directed. |
| 39 | Supply and fixing energy efficient LED Security light fitting of 35W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, complete fitting with all accessories and following specifications,(a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the same make as of the luminaire.(j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily) |
| 40 | M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel & wiremesh, PCC chamber in cement concrete (1:2:4) type B1 including 40mm thick pre-cast RCC (1:2:4) type B0 cover and 40x40x6mm angle iron frame on top of pit cover and excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. complete all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysAug 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender