Power Government Departments Closing in 4 days TDR #56895921

Tender For Supply Installation Testing and Commissioning of 8 Mtr Mini Mast With 4 Nos Of 100W Led Flood Lights At Ward 16 , Cholappuram And Ward 5 , Nariyarakunnh In Cheriyamundam Grama Panchayath, Tanur Block Panchayath Under Mplads 2025-26 Of Sri

Issued by Government Departments · Malappuram, Kerala
Tender Value
2.47 Lakhs
Estimated cost
Bid Submission
14 Aug 2026
4 days left
EMD
6177
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Malappuram → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of 8 Mtr Mini Mast With 4 Nos Of 100W Led Flood Lights At Ward 16 , Cholappuram And Ward 5 , Nariyarakunnh In Cheriyamundam Grama Panchayath, Tanur Block Panchayath Under Mplads 2025-26 Of Sri Abdussamad Samadani Mp(Project Code:12225)

BOQ

Name of Work:- SITC of 8 Mtr Mini Mast with 4 nos of 100W LED Flood Lights at ward 16 , Cholappuram and ward 5 , Nariyarakunnh in Cheriyamundam Grama Panchayath, Tanur Block Panchayath under MPLADS 2025-26 of Sri Abdussamad Samadani MP(Project Code:12225)
Sl. No. Item Description
1Civil Work
22.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil
34.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size)
45.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
55.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
65.1.2Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources)
713.1.1 12 mm cement plaster of mix: 1:4 (1 cement : 4 fine sand)
82.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m
9Electrical Work
1090.15.1.1 Supply, installation, testing and commissioning of Octagonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter, thickness 3 mm, base plate dimensions of 200 x 200 x 16 mm, suitable for windspeed as per IS 875 Part III, fixed head frame including round arm luminary carriage suitable to install 4/6 luminaries in symmetrical arrangement including connector, foundation bolt 4 nos, existing RCC foundation and junction box etc., complete. 8 Meters height
1190.15.4.7Supply Conveyance, installation, testing and commissioning of 100W LED Floodlight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chipmake Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internalsurge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartmentshould be seperatly accessible for maintenance (LM 79&80 certificates from NABLaccredited Third party lab to be produced mentioning chip manufacturer)
12OD117658/2026-2027Supply and fabrication conveyance and installation of Feeder Pillar Sintex BoxDouble Door.
13OD117646/2026-2027Supply and fixing of 25A 2 Pole AC 1 rated power contactor, 25A Connector, Digitaltimer, SuitableCopper socket, 2.5 sq. mm ISI marked FRLS PVC insulated single core copperconductor cable, 1.5 sq.mm ISI marked FRLS PVC insulated single core copper conductor cable.
14OD117647/2026-2027Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-wayneutral links mountedon DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVCinsulated single core copper conductor cable.
1590.14.5Supply and fabrication conveyance and installation of angle iron frame work for wallmounting panel board
162.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
172.10.3Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole
182.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
192.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps
2090.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVCsheathed 650/1100 V grade copper conductor round flexible cables conforming to IS694 part I 1960 in the existing surface / recess conduit as required including givingnecessary connections of the following sizes.3 core 1.50 sq mm
2190.6.5.12Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVCsheathed 650/1100 V grade copper conductor round flexible cables conforming to IS694 part I 1960 in the existing surface / recess conduit as required including givingnecessary connections of the following sizes.3 core 2.50 sq mm
225.3Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke andsalt ) as required.
2390.16.4.2Supply and clamping the following sizes of strips on surface of wall / parapet/existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted orheavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good thedamages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip
2490.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG)
2590.16.5.3Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG)
2690.12.1.12Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in ground includingexcavation of trench of size 35 x 75 cm, refilling the trench etc. as required butexcluding sand cushioning and protective covering (in ordinary soil).3 core 4 sq mm
2790.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated(DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanicalprotection to underground power cables with all required accessories in ground in theexisting trench50/38 mm or nearest size
28OD117645/2026-2027Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.<br>3 X 4 sq. mm (19mm)
29OD117648/2026-2027Fabrication ,supply, conveyance and installation of Granite name board indicating thecost involved, the commencement, completion and inauguration date etc
30OD117659/2026-2027Supply and fixing of Name Board with Angles, Flats, Square pipe, ACP Sheetincluding Nut &Bolt Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56895921
AUTHORITY Government Departments
TENDER VALUE 2.47 Lakhs
LAST DATE 14-08-2026
Authority
Authority Name Kerala Electrical And Allied Engineering Co Limited
Work Description Tender for Supply Installation Testing and Commissioning of 8 Mtr Mini Mast With 4 Nos Of 100W Led Flood Lights At Ward 16 , Cholappuram And Ward 5 , Nariyarakunnh In Cheriyamundam Grama Panchayath, Tanur Block Panchayath Under Mplads 2025-26 Of Sri Abdussamad Samadani Mp(Project Code:12225)
Basic Detail
Tender No KEL/ KEMG/ 100/2026-27
Bidding Type Tender
Location
City Malappuram
State Kerala
Key Dates
Publish Date 07 Aug 2026
Submission Date 14 Aug 2026
Open Date 17 Aug 2026
Finance
Tender Value 2.47 Lakhs
Tender Fee 590
EMD 6177
Exemption Available
Document List
a734cd92-1574-421d-ade5-8a83f88cec48.html
BOQ_1463338.xls
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

a734cd92-1574-421d-ade5-8a83f88cec48.html

xls

BOQ_1463338.xls

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders