Tender For Repair/Maint Of Lt Oh Lines/Ug Cables, Lt Feeder Pillar Boxes, Lt Panels, Poles, Capacitor, Panels, Connected Switch Gears And Other Allied Works At Unchibassi Under Ge South Pathankot
Tender Value
10 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
16 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hoshiarpur → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Lt Oh Lines/Ug Cables, Lt Feeder Pillar Boxes, Lt Panels, Poles, Capacitor, Panels, Connected Switch Gears And Other Allied Works At Unchibassi Under Ge South Pathankot
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, Foundation, filling of poles or stays complete all as specified and directed by Engineer-in-Charge. |
| 2 | Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 3 | Returning, filling in, including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required complete all as specified and directed by Engineer-in-Charge. |
| 4 | M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified and directed. Note: Punned thickness of sand shall be measured. |
| 5 | Supply and laying sub class 'B' bricks of (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge |
| 6 | Laying only old bricks retrieved from item No. 7 here-in-after of any size/type laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge |
| 7 | Taking up the existing cables from trenches of any size any type all as specified and directed by Engr-in-Charge. |
| 8 | Supply and lay cable XLPE insulated armored heavy duty electric cable with aluminum conductor, 1100 volts grade of cross sectional area 16 Sq mm 2 core complete all as specified and directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushioning , cable protection cover, GI protection pipe shall be measured and paid for separately under respective item of Schedule |
| 9 | All as per item No. 8 here-in-before but of size 16 Sqmm 04 core |
| 10 | All as per item No. 8 here-in-before but of size 25 Sqmm 4 core |
| 11 | All as per item No. 8 here-in-before but of size 35 Sqmm 3.5 core |
| 12 | All as per item No. 8 here-in-before but of size 50 Sqmm 3.5 core |
| 13 | All as per item No. 8 here-in-before but of size 70 Sqmm 3.5 core |
| 14 | All as per item No. 8 here-in-before but of size 95 Sqmm 3.5 core |
| 15 | Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 10 to 16 Sqmm 2/4 core with working voltage 1100 volts, complete all as specified and directed. |
| 16 | Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 25 to 50 Sqmm 3.5/4 core with working voltage 1100 volts, complete all as specified and directed. |
| 17 | Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 70 to 120 Sqmm 3.5 core with working voltage 1100 volts, complete all as specified and directed. |
| 18 | Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 150 to 185 Sqmm 3.5 core with working voltage 1100 volts, complete all as specified and directed. |
| 19 | Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 240 to 300 Sqmm 3.5 core with working voltage 1100 volts, complete all as specified and directed. |
| 20 | Material, labour , testing & commissioning of indoor End jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 16 to 50 Sqmm 3.5/4 core with working voltage 1100 volts, complete all as specified and directed. |
| 21 | Material, labour , testing & commissioning of indoor End jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 70 to 120 Sqmm 3.5 core with working voltage 1100 volts . |
| 22 | Material, labour , testing & commissioning of indoor End jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 150 to 185 Sqmm 3.5 core with working voltage 1100 volts, complete all as specified and directed. |
| 23 | Material, labour , testing & commissioning of indoor End jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 240 to 600 Sqmm 3.5 core with working voltage 1100 volts, complete all as specified and directed. |
| 24 | M&L for GI pipe light grade 40 mm dia for cable protection on road crossings /plinth protection with fixed to the pole or wall etc including suitable fittings for cable protection complete all as specified and directed. |
| 25 | Material and labour for GI tubing light grade 80 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole including fittings complete all as specified and directed. |
| 26 | All as per srl item No 24 here-in-before but 50mm bore |
| 27 | Supply and erecting in true vertical or to be planed as strut, steel tubular swaged welded pole complete with MS base plate final taper plug, bolt, nuts & screw, 6mm thick of size 300mmx300mm welded at the centre of the pole, type 410 SP-31 (09 Mtr long) including drilling of holes of required size and nuts for fixing of cross arms, painting with coat of red oxide zinc chrome primer and two coats of aluminum paint on exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three black and three white bands at lower portion of pole each of 300mm height at 300mm spacing complete all as specified incl dismantling old one complete all as directed and specified. NOTE :- Earth work, Cement concrete in foundation, coping etc. will be measured and paid separately under relevant item. |
| 28 | S&F in repair PVC insulated 3 core 2.5 Sq mm stranded copper conductor cable for connecting OH line/junction box to street light fitting, testing and commissioning complete all as specified and directed. |
| 29 | M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete all as specified and directed. |
| 30 | M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work complete all as specified and directed. |
| 31 | M & L for disconnecting burnt end or portion of UG Cable, removing the cable from loop or trench including necessary excavation and earth work, relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminal by replace with new cable joint kit for cable of cross sectional area 10 Sqmm 4 core to 300 Sqmm 3.5 core of LT cable to pole, main switch, LT Panel etc. complete all as specified and as directed Note :- Cable joints and cable will be measured separately under respective item of schedule. |
| 32 | Supply and Fixing in Replacement for 600 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 50 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed. |
| 33 | Supply and Fixing in Replacement for 400 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed. |
| 34 | Supply and Fixing in Replacement for 250 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 25 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed. |
| 35 | Supply and Fixing in Replacement for 200 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 25 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed. |
| 36 | Supply and Fixing in Replacement for 160 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 16 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed. |
| 37 | S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carrying capacity 32 to 40 Amps complete including control wiring thimbles etc. complete all as specified and directed. |
| 38 | Supply, installing, testing and commissioning of LT feeder pillar box factory made outdoor type, fabricated out of 3.15 mm thick CRCA sheet with angle iron base frame made of 40x40x6mm, 45 cm height, dust and vermine proof, suitable for voltage 415 separate hinge door for each compartment for incoming and outgoing MCCB etc. with locking arrangement, with back door openable screwed, legs grouted in PCC including painting with two coats of epoxy powder paint over a coat of primer after alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminum busbar (TPN), including provn of following :- Note : (a) The panel shall be as per CPRI certificate (b) Rates inclusive of PCC complete. i) Alluminium bus bar 400 A- mounted on porcelain insulator - 01 Set ( Set of 4 Nos) with PVC sleeve insulation ii) MCCB 4 pole 415 V 3 phase 250 Amp, 36 KA (Thermal magnetic release) - 01 No (incoming) ii) MCCB 4 pole 415 V 3 phase 160 Amp, 25 KA (Thermal magnetic release) - 04 Nos (outgoing) vi) Digital Voltmeter of size 96x96mm 0-500 volts with selector switch - 01 No vi) Digital Amp meter of size 96x96mm rating 0-1000 Amp with CT's & selection switch - 01 No vii) RYB LED indicator- one set |
| 39 | Supply, installation, testing and commissioning of LT panel outdoor type suitable for 3 phase 415 Volt of both side opening double door with push type metal lock, heavy duty wide hinges, made out 3.15 mm thick CRCA sheet with angle iron frame of size 80 x 80 x 6 mm cubical type complete with 4 Nos Aluminium bus bar 200 Amp, MCCB 4 Pole , 100 Amp, 415 V, 25 KA (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%- 01 No (incommer) & RYB LED indicator- one set with IP 54 as per IS 13947 protection, internal wiring by FRLS grade multi stranded PVC insulated copper conductor of size not less than 10 Sq.mm duly marked with ferrule, incl powder coated painting in inner & outer side, including making all suitable necessary electrical connection complete all as directed by the Engineer -in - Charge. Note : (i) The panel shall be as per CPRI certificate. (ii) The rates deemed to be inclusive necessary PCC for grouting of panels. |
| 40 | S&F in repair Capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 10 KVAR capacitor complete all as specified and directed. |
| 41 | S&F in repair Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 3 to 15 KVAR complete all as specified and directed. |
| 42 | S&F in repair Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 20 to 25 KVAR complete all as specified and directed. |
| 43 | M&L in replacement of existing unserviceable contactor of current carrying range 25 A to 40 Amp (AC-3 duty) at different places in APFC panels/other electric panel including required electrical connections with suitable size of single core pvc copper cable & testing complete all as specified and directed. |
| 44 | M&L in replacement of existing unserviceable contactor current carrying range 9 to 18 Amp (AC-3 duty) at different places in APFC panels/other electric panel including required electrical connections with suitable size of single core pvc copper cable & testing complete all as specified and directed. |
| 45 | S&F in repair APFC relay with inbuilt PF meter suitable for 5A CTR suitable for 8 Stage complete all as specified and directed. |
| 46 | M&L for Earthing complete with galvanized cast iron earth plate electrode of size 600x600x6 mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using galvanized iron strip 32x6mm earthing lead as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil remain surplus excavated material all as required at site and specified in EP No 3 of SSR complete all as specified and directed by Engineer-in-charge incl testing on completion. |
| 47 | Supply and fixing in repair onload change over switch 04 Pole, confirming to IEC 947-E, EN-60947-3, AC -23A front operated, 415 V, 50 HZ of capacity 200 A front handle including dismantling the old burnt out change over switch, fixing complete with suitable lugs, testing complete all as directed and specified |
| 48 | Supply and fixing in repair onload change over switch 04 Pole, confirming to IEC 947-E, EN-60947-3, AC -23A front operated, 415 V, 50 HZ of capacity 400 A front handle including dismantling the old burnt out change over switch, fixing complete with suitable lugs, testing complete all as directed and specified |
| 49 | Supply and fixing in repair onload change over switch 04 Pole, confirming to IEC 947-E, EN-60947-3, AC -23A front operated, 415 V, 50 HZ of capacity 600 A front handle including dismantling the old burnt out change over switch, fixing complete with suitable lugs, testing complete all as directed and specified |
| 50 | M&L for preparation of old painted surfaces of LT electrical panel/Bus Bar chamber incl removing oily/greasy spots & rusting and cleaning internally and applying two coats of epoxy powder paint over a coat old primer after alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate complete all as specified and directed by Engr-in-Charge. |
| 51 | S&F in repair Digital Voltmeter of size 96x96mm rating 0-500 volts with selector switch complete all as specified and directed. |
| 52 | S&F in repair Digital Amp meter of size 96x96mm rating 0-1000 Amp with CT's & selector switch complete all as specified and directed. |
| 53 | S&F in repair R,Y,B indicator lamp for LT Feeder panel/Bus Bar chamber complete all as specified and directed. |
| 54 | Supply and fix in repair 20 mm dia HDPE flexible pipe for covering open electrical wire etc. , black colour complete all as specified and directed. |
| 55 | Supply and fix in repair 25 mm dia HDPE flexible pipe for covering open electrical wire etc. , black colour complete all as specified and directed. |
| 56 | Supply and fix in repair 32/40 mm dia HDPE flexible pipe for covering open electrical wire etc. , black colour complete all as specified and directed. |
| 57 | S&F loop-in/loop-out box of outer size 250x210x115 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc. complete in the box, duly fixed to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one. |
| 58 | Supply and fixing in replacement of MCB SP 6-32 Amps, 10 KA breaking capacity , 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge. |
| 59 | Supply and fixing in replacement of MCB SPN 32 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge. |
| 60 | Supply and fixing in replacement of MCB SPN 40 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge. |
| 61 | Supply and fixing in replacement of MCB TPN 40 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge. |
| 62 | Supply and fixing in replacement of MCB TPN 63 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge. |
| 63 | Supply only PVC insulation tape roll of dimension 1.80 cm x 6.5m x 0.125 mm for jointing the connection etc. complete all as specified and directed. |
| 64 | Supply and fix in repair 80 MM dia HDPE flexible pipe for covering open electrical wire etc. black colour complete all as specified and directed. |
| 65 | Supply and fixing in repair of industrial change over switch gear 400 Amp 415 V Four Pole Off Load Side Handle Operated In Sheet enclosure, Powder Coated, Weather proof conforming to IS: 13947 by connecting the electrical connection and fixing on wall or panel with clamp nut, bolt etc. complete all as specified and as directed by Engr-in-Charge. |
| 66 | Supply and fix in replacement of 1.1 KV LT DMC conical insulator of red colour for support of AL/CU strip of dimension 25 to 50 mm or as per site requirement all as specified and directed by Engr-in-Charge. |
| 67 | S&F in replacement of u/s AL thimbles/lugs for connection of LT cable of size 10 sqmm to 16 sqmm all as specified and directed by Engr-in-Charge. |
| 68 | S&F in replacement of u/s AL thimbles/lugs for connection of LT cable of size 25 sqmm to 50 sqmm all as specified and directed by Engr-in-Charge. |
| 69 | S&F in replacement of u/s AL thimbles/lugs for connection of LT cable of size 70 sqmm to 120 sqmm all as specified and directed by Engr-in-Charge. |
| 70 | S&F in replacement of u/s AL thimbles/lugs for connection of LT cable of size 150 sqmm to 300 sqmm all as specified and directed by Engr-in-Charge. |
| 71 | Supply and laying in repairs synthetic Insulating Mat of size 2m X 1m and 2mm thick for up to 3.3 KV Volts made from synthetic insulating material, free from any insertions leading to detoriation of insulating properties. Note : The upper surface should have small aberration (Rough Surface) with out edges to avoid slippery effects.The mat should be fire retardant & self extiguishing complete all as specified and directed by Engr-in-Charge. |
| 72 | M & L for preparation of old painted surfaces of 09 mtr long PCC poles incl removing oily/greasy sports and applying one coat of synthetic enamel paint of black and yellow in alternate strip of 30 cm witdth upto 1.5 mtr height including including applying a coat of white wash on pole coping and lettering the pole details with white letters/black background etc complete all as directed |
| 73 | M & L for preparation of old painted surfaces of 09 mtr long steel poles incl removing oily/greasy sports and applying one coat of aluminium paint complete above 1.5 mtr and one coat of synthetic enamel paint of black and yellow in alternate strip of 30 cm witdth upto 1.5 mtr height including applying a coat of white wash on pole coping and lettering the pole details with white letters/black background etc complete all as directed |
| 74 | S&F in replacement of APFC panel front glass for min 5 KVAr to 35 KVAr or as per site requirement all as directed. |
| 75 | Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.(ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender