Tender For special repair Of Slabs Under Ceiling, Open Courtyard At First & Second Floor With Projections On Windows In Punjab Govt. Houses Cat-I, Group-Iii (2471-2486, 2503-2534, 2543-2560) Sector 39C, Chandigarh
Tender Value
47.46 Lakhs
Estimated cost
Bid Submission
18 Aug 2026
9 days left
EMD
94939
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special repair Of Slabs Under Ceiling, Open Courtyard At First & Second Floor With Projections On Windows In Punjab Govt. Houses Cat-I, Group-Iii (2471-2486, 2503-2534, 2543-2560) Sector 39C, Chandigarh
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling brick work tile, masonry or tile lining. (b) In cement. (CSR 8.5) (b) |
| 2 | Dismantling concrete (e) Reinforced cement concrete(CSR 8.6) (e) |
| 3 | Scraping (c) Cement plaster (CSR 8.31) (c) |
| 4 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.(CSR 9.8) |
| 5 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.(CSR 10.20) |
| 6 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete. (CSR 18.18) |
| 7 | Steel work in built up tubular pipes (round, square or rectangular hollow tubes etc. ISI Marked) for flat shed/railing at all heights (ie.Where no truss work is involved) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.(CSR 18.53) |
| 8 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S.clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerincharge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. (CSR 31.36) |
| 9 | Chipping of loose concrete from under ceiling with scratching tool and applying cement slurry on the exposed layer complete in all respect to the entire satisfaction of Engineer-in-Charge. (N.S) |
| 10 | 12.5 mm thick cement plaster 1:4 (CSR 15.9) |
| 11 | 12.5mm thick raised cement mortar bend / drip course in cement mortar 1:4 (CSR 15.13) |
| 12 | Plastering on underside of ceiling 10mm thick cement plaster 1:4 (CSR 15.44) |
| 13 | White washing (Three coat). (CSR 16.3) |
| 14 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.(CSR 16.17) |
| 15 | Applying priming coat with metal primer on new steel or iron work including preparation of surface.(CSR 16.20) |
| 16 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43 litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm. (CSR 16.60) |
| 17 | Providing 5\\" long dash fastener or rawl plug with the help of drilling machine to fasten the railing in concrete slab including dismantling of concrete floor and after fixing railing grouted with CC 1:2:4 to match the level with finished floor including all other expenditure complete in all respect (N.S) |
| 18 | Site clearance (b) Surface dressing of terrace including removing rank vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kinds of soil and repair with cement mortar. (CSR 32.4) (b) |
| 19 | Water proofing treatment of Roof Slab/chajja with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge.(CSR 13.91) |
| 20 | Providing and applying injection grouting using cement slurry admixed with Fosroc Chemical Conplast WL or any other equivalent compound @ 300 ml/ Bag of cement through the uPVC nozzles ( 12mm dia uPVC/ Plastic Nozzles - 4\\" to 9\\" long @ 5 No: / Sqm of area) , provided into the cracks/ honeycombed areas using 140 PSI hand operated Grouting Pump under pressure till the refusal,doing final Cement slurry Grouting (after 28 Days),, finally cutting & sealing of Nozzle. including all labour, supervision, tools and tackles and transportation etc. complete as per direction of Enginner -in- charge. (CSR 13.94) |
| 21 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS clamps. (i) U-PVC pipes (working pressure 4 kgf. / sqcm) pipe 110 mm dia.(CSR 13.74) (a) (i) |
| 22 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. (a) UPVC 110 mm bend. (CSR 13.75) (a) |
| 23 | Carriage of Earth,Surkhi, Sand, Earth, Fly Ash, Bajri, Ballast, Stone boulders, Kankar and building rubbish, Earth. (i) 10.0 km (CSR 5.2) (i) |
| 24 | Credit of bricks |
| 25 | Credit of brick bats (CSR M12D) |
| 26 | Removal of Malba by mannual labour |
| 27 | Credit of Steel Scrape recovered after the Dismantling the RCC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysAug 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender