Tender For Construction Of 220/132 Kv, 1X160 Mva; 132/33 Kv, 1X40/50 Mva Substation At Malpura Including Survey Supply Of All Equipments/Materials, Erection (Including Civil Works), Testing And Commissioning On Turnkey Basis Against Specification No.

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
51.23 Crore
Estimated cost
Bid Submission
07 Sep 2026
27 days left
EMD
1.02 Crore
Bank guarantee accepted
Document Fee
23600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of 220/132 Kv, 1X160 Mva; 132/33 Kv, 1X40/50 Mva Substation At Malpura Including Survey Supply Of All Equipments/Materials, Erection (Including Civil Works), Testing And Commissioning On Turnkey Basis Against Specification No. Rvpn/Ehv/Bn-9019002607.

BOQ

Name of Work:- Construction of 220/132 kV, 1x160 MVA; 132/33 kV, 1x40/50 MVA substation at Malpura INCLUDING SURVEY SUPPLY OF ALL EQUIPMENTS/MATERIALS, ERECTION (INCLUDING CIVIL WORKS), TESTING AND COMMISSIONING on Turnkey basis AGAINST SPECIFICATION NO. RVPN/EHV/BN-9019002607.
Sl. No. Item Description
1MAIN MATERIAL/ ITEMS
2Circuit Breaker
3220kV circuit breakers (3 Ph.) Along with support Structure
4220kV circuit breakers (3 Ph.) Along with support Structure
5132 kV Circuit Breakers
6132 kV circuit breakers (3 Ph.) Along with support Structure
71250 A, 40 kA
833 kV Circuit Breakers
933 kV circuit breakers (3 Ph.) Along with support Structure
101600 A, 31.5kA
11Instrument Transformers
12Capacitor Voltage Transformer
13Single-Phase, 220 kV, 4400 pf CVT
14Single Phase 132 kV , 4400 pf CVT
1533 kV Potential Transformer
1633/√3 kV /110-110√3
17Current Transformer (1-Phase)
18220 kV CT
191000/1 A, 5C
20132 kV CT
211000/1 A, 3C
22500/1 A, 3C
2333 kV CT
241000/1 A, 4C
25500/1A, 2C
26C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)
27New Substation
28Control Panel for 220 kV Transformer (220 kV Side) Type: SAS-THCB
29Relay Panel for 220 kV Transformer (for both HV & MV) Type: SAS-THRB
30Control Panel for 220 kV Feeder Type: SAS-FCB
31Relay Panel for 220 kV Feeder Type: SAS-FRB
32Control Panel for 220 kV Bus Coupler Type: SAS-BCCB
33Relay Panel for 220 kV Bus Coupler Type: SAS-BCRB
34220 kV Busbar Protection Relay Panel Type: SAS-BBRB
35Control Panel for 220 kV Transformer (132 kV Side) Type: SAS-TLCB
36Relay Panel for 220 kV Transformer (132 kV Side) Type: SAS-TLRB
37Control and Relay Panel for 1x 50/31.5/25 MVA, 132/33 kV Power Transformer Type SAS-TCRA
38Control Panel for 132 kV Feeder Type SAS-FCA
39Relay Panel for 132 kV Feeder Type SAS-FRA
40Control and Relay Panel for 132 kV Bus-Coupler Type SAS-BCRA
41Control and Protection Panel for 33 kV Feeder (I/C, O/G)/Bus-coupler/ Capacitor Bank [For TWIN FEEDER/BAY] Type-FCRD
42Station HMI [Industrial grade Computer with 21\\"TFT monitor as per specification requirements]
43Station HMI (Hot Standby)[Industrial grade Computer with 21\\"TFT monitor as per specification requirements]
44HMI View Node[Industrial grad Computer with 21\\"TFT monitor as per specification requirements]
45A3 Size B&W Laser Printer
46Substation Automation System Network Panel Type SAS-NW
47Modems (both sending and Receiving End) for communication to RCC & Sub SLDC for PLCC]
48Data Concentrator Unit (DCU) at Substation for RAS mounted in suitable enclosure & fully wired
49Software: Application as well as System Software as per specification requirements for various hardware elements for meeting of functional requirement of the specification.
50Substation Auxiliary Monitoring Panel Type SAS-SAMP
51Other Items:
52Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements.
53Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards.
54Surge Arresters
55220 kV LA
56132 kV LA
5733 kV LA
58Substation LT Transformer
5933/ 0.433 kV, 250 kVA LT transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil
60Batteries & Battery Charger
61Batteries (Sizing shall be as per requirement of technical specification)
62220 V [Min. 600 AH]
6348 V [Min. 600 AH]
64Battery Charger System
65220 V Float and Boost
6650 V Float and Boost
67Lighting System
68Outdoor Lighting & other Works
69Lighting Fixture Type FL-1
70Lighting Fixture Type FL-2
71Outdoor Receptacle
72Type-RP
73Type-RO
74Substation Premises Lighting
75Lighting poles
76Type-L1
77Type-D1
78Street Lighting Type-SL-L1 for mounting on poles
79Street Lighting Type-SL-D1 for mounting on Poles
80Sub-Lighting Boxes/Panels Type -SLP at Lighting Mast and Other Loaction as designated complete with all controgears and accessories, items etc.
81Lighting Panel Type ACP-2 as per technical specification
82Lighting Panel Type ACP-3 as per technical specification
83Indoor Lighting & Other Works
84Electrification
85Electric Fitting (if not covered under Civil Works) with G.I. Conduit, Junction Boxes, pull out boxes, copper wiring, Modular Switchboards, Modular Switches, GI Wire (16SWG) etc. for control room, Hall and administrative office building as per the requirements of the specifications
86Illumiation
87Lighting fixtures and Receptacles (including accessories/ materials etc. as per requirement alongwith complete accessories and mounting arrangements)
88Indoor Lignting Panels
89Lighting Panel (Indoor) Type ACP-1 as per technical specification
90Lighting Panel (Indoor) Type DCP as per technical specification
91Wall mounted fans Approx. 400 mm sweep
92Ceiling Fan - Approx. 1400mm sweep with electronic Step regulator
93Exhaust Fans
94Fire Extinguisher DCP Type
95i) 5 Kg.
96ii) 10 Kg.
97Carbon di oxide type – 6 Liters.
98Foam Type- 9 Liters
99Sand type
100i) GI Buckets 9 liters capacity
101ii) Steel Stands for four buckets
102Air Conditioning System
103Air Conditioning for the Rooms specified in the specifications
1041.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building]
105Power Cables(XLPE)
1061Cx630 sq.mm
1073.5Cx300 sq.mm
108Power Cable(PVC)
1091Cx150 sq.mm
1103.5Cx70 sq.mm
1113.5Cx35 sq.mm
1124Cx16 sq.mm
1134C x 6 Sq. mm
1142C x 6 Sq. mm
115Control Cable (PVC)
1164 CX4 Sq. mm
1175Cx2.5 sq.mm
1187Cx2.5 sq.mm
11910Cx2.5 sq.mm
12014Cx2.5 sq.mm
12119Cx2.5 sq.mm
122Substation Structures
123Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]:
124NON Standard Pipe support Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for Pipe support structure as per specification requirements]:
125Isolators
126220 kV (3-Phase) (Horizontal DOUBLE BREAK)
1271600A, 50KA, isolator with one E/S
128Post insulators for above Isolator
1291600A, 50KA, isolator with two E/S
130Post insulators for above Isolator
1311600A, 50KA, isolator without E/S
132Post insulators for above Isolator
1331600A, 50KA, isolator without E/S (TANDEM Type)
134Post insulators for above Isolator
135132 kV (3-Phase) (Horizontal DOUBLE BREAK)
1361250A, isolator with one E/S
137Post insulators for above Isolator
1381250A isolator without E/S
139Post insulators for above Isolator
14033 kV (3-Phase) (Horizontal DOUBLE BREAK)
1411250A, isolator without E/S
142Post insulators for above Isolator
143800 A isolator without E/S
144Post insulators for above Isolator
145800A isolator withE/S
146Post insulators for above Isolator
147Switchyard Erection
148Busbar & Interconnections
149New Substation/ Switchyard
150220 kV Switchyard Works:
151Main-I Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/Porcelain Long Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]
152Main-II Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Pocelain Long Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]
153Aux Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string(DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]
154220 kV Overhead Jack Bus (for DMT Layout) on Twin ACSR Zebra(Bus-Coupler Bay)/ Single ACSR Zebra (Transformer/ Line on ACSR Zebra) with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
155Twin ACSR Zebra
156Single ACSR Zebra
157Equipment Interconnections to Main Bus, Overhead Bus including Single ACSR Zebra (for Line), Twin ACSR Zebra (forTransformer bay & B/C Bay), bus-bar materials, clamps, connectors, spacers, corona shields, including equipment connectors, Junction box including of all accessories etc. for the following:
158220 kV DMT-type layout
159Line bay
160Transformer bay
161Bus-Coupler
162Bus CVT Interconnections to Main Buses including Single ACSR Zebra, clamps, connectors, junction box including of all accessories etc.
163132 kV Switchyard Works:
164Main Bus: 132 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulator, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays]
165Aux Bus: 132 kV Single ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays]
166132 kV Overhead Jack Bus (for Main & Aux Layout) on Twin ACSR Zebra(220 kV Transformer/Bus-Coupler Bay), Single ACSR Zebra(132 kV Transformer/Bus-Coupler Bay) Single ACSR Panther (Line on ACSR Panther) on Single Panther ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
167Twin ACSR Zebra
168Single ACSR Zebra
169Single Panther
170Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Zebra (Bus Sectionalizer/ 220 kV Transformer /Bus-Coupler Bay)/ Single ACSR Zebra (132 kV Transformer Bay) Single ACSR Panther ( Line on ACSR Panther), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:
171132 kV Main & Aux-type layout
172Line bay
173Transformer bay
174Bus-Coupler
175Bus CVT Interconnections to Main Bus including Single ACSR Zebra, clamps, connectors, junction box including of all accessories etc.
17633 kV Switchyard Works:
177Main Bus: 33 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string, Disc Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 5 bays+ Bus Coupler]
178Aux Bus: 33 kV Single ACSR Zebra Bus with conductor, busbar material, insulator string, Disc Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 5 bays+ Bus Coupler]]
17933 kV Overhead Jack Bus for Transformer Incomer (for Main & Aux Layout) on Twin Zebra ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
180Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Panther ( Transformer /Bus-Coupler Bay)/ Single ACSR Panther ( Line bays), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:
18133 kV Main & Aux-type layout
182Line bay
183Transformer bay
184Bus-Coupler
185LT Transformer connection with ACSR Panter conductor, 33 kV DO Fuse Set alongwith required Clamp/connectors
186Bus PT Interconnections to Main Bus including Single ACSR Panter , clamps, connectors, junction box including of all accessories etc.
187Bus Post Insulators (BPI)
188220 kV
189132 kV
19033 kV
191Earthing & Lightning Protection System
192Main, Auxilary Earthmats, Risers etc. for complete earthing in the Switchyard Area
19328 mm Dia MS Rod
19428mm Dia, 3.2 M Long MS Rod Earth Electrodes Directly Driven.
19528mm Dia, 8 M Long MS Rod Earth Electrodes Directly Driven.
19628mm Dia, 3.2M Long MS Rod Earth Electrode in untreated pit with test link
19728 mm dia, 3000 mm long GS pipe electrodes with test links and treated earth pits with C.I. cover hinged to C.I. frame alongwith all associated civil works
19850X12 mm GS Flat
19950X6 mm GS Flat
200Earth Enhancing Compound for treated pits as above and other requirement as per specification
201Cleat type clamps(8mm thick) for earthing down conductor (10.98 mm dia), 50x12 mm GS Flat and 50x6 mm GS flat
202Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats
203Earth Wire for Shielding Protection of Switchyard
2047/3.15 Galvenized Steel Wire
205Earthwire tension clamps with D Shackle assembly
206PG calmp to suit 7/3.15 mm GS earth wire
207Cleat clamp on structure to suit 7/3.15 mm GS earth wire/ 50 X 12 mm GS Flat
208Pad clamp on structure to suit 7/3.15 mm earth wire and 75 x 12 GS flat
209Lug to suit 7/3.15 mm earth wire
210Other Clamps, Copper Earth Bond etc. as per layout diagram for erection of Earth Wire
211Bay Marshalling KIOSK
212200 way (Stud Type Connectors)
213AC Distribution Boxes (Outdoor Type)
214Outdoor AC Distbibution Box (Double Front type)
215Outdoor AC Distbibution Box (Single Front type)
216Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building]
217Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washers etc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works]
218LT Switchgear
219LT AC Main Panel
220LT AC Distribution Board
221Main Lighting Distribution Board
222Emergency Lighting Distribution Board
223220V DCDB
22448V DCDB
225PLCC EQUIPMENTS
226220 kV Wave trap (1250A, 0.5 mH, 40 kA)
227132 kV wave trap (1000A, 0.2 mH, 40 kA)
2284 kH to 16 kHz Channel Digitial PLCC Carrier terminal with digital protection coupler (DTPC) IEC/101/104 data and 4 W E&M speech applications .
2294 kH to 16 kHz Channel Digitial PLCC Carrier terminal with out digital protection coupler (DTPC) IEC/101/104 data and 4 W E&M speech applications .
230VFT equipment (Modem) suitable for transmission of Data through PLCC links based on frequency shift keying modulation techniques programmable for both baud rate from 50 Baud to 2400 Baud and center frequency through switches or jumpers (A.F. Shift Channel)
231Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
232Coupling Devices for Phase to Ground coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
233HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
234Microprocessor based 24/8 line Electronic Private Automatic Exchange (EPAX) with PLCC interphasing facility
235Telephone Sets (Push Button Type)
23610 pair Jelly Filled and armoured telephone cable with copper conductor of 0.5 mm
2375 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.5 mm
2385 Pair jelly filled un armoured telephone cable having copper conductor of Dia. 0.5 mm
239TESTING & MEASURING INSTRUMENTS, TOOLS & TACKLES AND MISCELLANEOUS ITEMS
240(A) TESTING EQUIPMENT/ INSTRUMENTS [This shall consist of all the standard accessories, cables, software etc. required for satisfactory operation of equipment meeting functional requirements]
241Insulation Tester (5000 Volts, Digital)
242SF6 Leakage Detector
243Digital Multimeter
244Digital Clamp Meter
245Level meter cum Generator incliding impedance return loss
2464-1/2 digit LCD Multimeter with input impedance of 10Mohm & with a range of 0.1 mV to 1000 V DC, 0.1mV to 600v AC, 0-10 AMP AC,(40hz to 10KHz) & 0-20 Mohm With builtin power –supply.
247(B) Maintenance Tools& Tackles
248Oil Sampling Bottle (1 Liter Capacity)
249Vaccum Cleaner
250Telescopic ladder aluminium 6 meter height
251Ring spanner set
252Tube spanner set
253Pipe wrench 24 inch
254Pipe wrench 18 inch
255Hydraulic crimping tools up to 630 sq.mm
256Threading die set for pipe threading
257Welding machine (arc welding) 10kVA
258Heavy duty drilling machine
259Bench Vice
260Insulated cuttingplier 12 inch
261Insulated cuttingplier 8 inch
262Screw driver 18 inch
263Screw driver 12 inch
264Hammer 8 lbs
265Hammer 2 lbs
266Chain pulley block 5 ton
267Pipe derrick
268Allen Keys
269Box Spanners
270(C )Office and Miscellaneous Equipments/ Items
271Insulation Rubber mat (1mX2mX 12 mm)
272Isulation Rubber Gloves (33 kV Tested)
273Furniture for Control Room Building:
274SCADA Room Furniture (Control Desk for specified consoles and Revolving Chair) matching with the overall interiors as per specification
275Executive Desk bulit in wood and steel with lockable drawings on both side (6 feetX2 ½ feetx 2 ½ feet)
276Junior executive table with three drawings on right side One Cup board left side with prelaminated decolam top 20mm thick over painted M.S. Frame ( 4 ½ feet x 2 ½ feetx 2 ½ feet).
277Library Shelf with Glass Door (min 4 Shelf)
278Steel tubular “S” type with continuous and one feet dia 14guage pipe, cane seat backing, teak wood with quality cane.
279Archival Storage 4 Drive Type
280Lateral Filing Cabinets
2813 Drawer Unit
2824 Drawer Unit
283Steel Almirah of size 6 ½ feetx 3 feet x 19 inch with four shelves making five compartments in 22 guage or better with two way locking system.
284Steel Almirah (with Glass doors) of size 6 ½ feetx 3 feet x 19 inch with four shelves making five compartments in 22 guage or better with two way locking system.
285Minor Almirah of size 4 ½ feet x30 inch x 17 inch with three shelves making four compartments in 22 guage or better with two waylocking system.
286Steel rack of size 5 feet x 3 feet x 16 inches with six shelves making five compartments (22 guage).
287Steel file trays of size 16 inches x11 inches x 3 inches of guage 14 SWG.
288Steel stools of size 15 inch x15 inch x 18 inch square pipe 16 guage
289Steel waste paper baskets of size 12 inch (H) and Approx. 10 inch Dia Round.
290Key board (wooden) with Glass door
291First Aid Box
292Shock Treatment Chart [Laminated with Frame]
293Safety Instruction Boards [ Laminated with Frame]
294(D) Drinking Water Arrangement
295Water Cooler (Storage type, Storage Capacity 40 Ltr, Cooling Capcity 20 Ltr./hr)
296RO/ Water Purifier
297Refrigirator (380 Lt.)
298Substation Name Board [1 No. Glow Type & 1 No. Painted Type] [Size and Color etc. be got approved from owner]
299Danger Plate [Size and Color etc. be got approved from owner]
300MANDATORY SPARES
301(A )Circuit Breakers
302220 KV
303(One pole of circuit breaker complete with pole column and interrupter with M.B. but without support structure and operating mechanism.
304Rubber gaskets, ‘O’ rings and seals
305Fixed Contacts
306Moving Contacts
307Terminal pads and connectors
308Closing Assembly Valve
309Trip Assembly Valve
310Auxiliary Switch Assembly
311Operation Counter
312Closing Coils
313Tripping coils
314Support insulator complete for one pole of breaker
315145 kV
316One pole of circuit breaker without support structure and operating mechanism.
317Rubber gaskets, ‘O’ rings and seals
318Fixed Contacts
319Moving Contacts
320Terminal pads and connectors
321Closing assembly valve
322Trip assembly valve
323Auxiliary switch assembly
324Operation counter
325Closing Coils
326Tripping coils
327Support insulator (set complete for one pole of breaker)
328Instrument Transformer
329Spare of 245kV Capacitive Voltage Transformer
330(i) Complete CVT
331Spare of 145kV Capacitive Voltage Transformer
332(i) Complete CVT
333Spare of 245kV Current Transformer
334(i) Complete CT [1 No. each type supplied)
335Spare of 145kV Current Transformer
336(i) Complete CT (1 No. each type supplied)
337Spare of 33 kV Current Transformer
338(i) Complete CT (1 No. each type supplied)
339(E) C&R panels (similar items as used in the quoted panels)
340Bay Control Unit (220 kV Side of offered type)
341Bay Control Unit (132 kV Side of offered type)
342Bay Control & Protection Unit (33 kV Side of offered type)
343Bay Unit (For 220 kV Busbar Protection of offered type)
344Bay Protection Unit (Distance for 220 kV Feeders of offered type)
345Bay Protection Unit (Line Distance cum Differential for 220 kV Feeders of offered type)
346Bay Protection Unit (Distance for 132 kV Feeders of offered type)
347Bay Protection Unit (Differential for 220 kV Transformers of offered type Main-I)
348Bay Protection Unit (Differential for 220 kV Transformers of offered type-Main-II)
349Bay Protection Unit (Differential for 132 kV Transformers of offered type)
350Bay Protection Unit (Back-up Overcurrent & E/F of offered type)
351Breaker failure relay (numerical type)
352Trip circuit supervision relay
353Self reset trip relay
354Hand reset trip relay
355Timer relay
356DC supervision relays
357Flag relays
358Auxiliary relays
359Multifunction Panel Meter
360Fiber Optic Cable with Connectors
361Transducers (Each Type used in the autoamtion system)
362Ethernet Switch (of offered type)
363(F) Station Transformer
36410% of total Transformer Oil quantity in non-returnable drums
365HV bushing
366LV bushing
367Pressure relief device
368Tap charger contact
369Set of valves
370Set of gasket
371Silica gel required for five replacements
372(G) Surge Arrester
373220kV class 198 kV rating LA complete as specified.
374132kV class 120 kV rating LA complete as specified.
37533 kV Class of 30kV rating LA Complete as specified
3762 Nos. Terminal connector of each type as spare
377(H) Battery & Battery Charger
378220 V & 48 V Type Battery
379Spare battery cell without electrolyte
380Terminal connectors with bolts & Nuts
381Float level indicators
382Vent Plugs
383220V/ 50V Battery Chargers
384Set of Control Cards
385Set of relays
386Set of contactor
387Micro-switches
388Filter Capacitors
389Thyristor/ Diode
390Set of switches
391Set of wound resistors
392Potentiometers
393Fuses of Thyristor with indicators
394(I) L.T. SWITCHGEAR :
395Relays
396CTs AND PTs
397Switches/Push buttons and Meters
398TPN Switches/MCB
399L.T. Breaker spares
400a) Spring charging motor
401b) Aux. Contact sets
402c) Busbar Seal off insulators
403d) Arc-chutes
404e) Moving contacts
405f) Arcing contacts (Fixed/Moving)
406g) Springs (Closing/Opening)
407h) Closing coil
408i) Tripping coil
409j) Aux. finger contact
410k) Limit switches
411l) Jaw contacts
412Busbar
413a) Busbar insulators
414b) Interphase barrier
415c) Busbar strip 1mm (Aluminium)
416(J) LIGHTING SYSTEM
417Single Pole MCB
418Triple pole MCB
419Fluorescent tube & Starter
420a) Choke
421b) Bottom Strips
422c) Top covers & reflector (if applicable)
423d) Holders
424e) Complete fittings
425Sodium vapour/Mercury vapour Lamps a) Lamp
426b) Ballast
427c) Condenser/ Igniter
428d) Lamp holder
429e) Lamp holder
430f) Complete fittings
431Incandescent lamp
432a) Bulbs
433b) Holders
434c) Complete fittings
435Switches and sockets
436Junction box
437Celing Fan
438(K) Clamps & Connectors Set
439(M) Isolators
440220 kV
441Solid core Insulator Stacks (Requirement of one Isolator)
442Relays, power contactors, MCB’s switch fuses, push buttons and resistors, timers, key interlock for electrical control circuit as per approved schematic --- Each set containing one number of each type and rating as offered.
443Limit switches & aux.switches--Each Set containing one no. of each type and rating as offered
444Motor with gear assembly and bevel gear assembly.
445Bearings (Requirement of one Isolator)
446Current carrying assembly total (Requirement of one Isolator)
447132 kV
448Solid core Insulator Stacks (Requirement of one Isolator)
449Relays, power contactors, MCB’s switch fuses, push buttons and resistors, timers, key interlock for electrical control circuit as per approved schematic --- Each set containing one number of each type and rating as offered.
450Limit switches & aux.switches--Each Set containing one no. of each type and rating as offered
451Motor with gear assembly and bevel gear assembly.
452Bearings (Requirement of one Isolator)
453Current carrying assembly total (Requirement of one Isolator)
45433 kV
455Solid core insulator Stacks ( Requirement of one Isolator)
456Limit switches and auxiliary switches ---Each Set containing one no. of each type and rating as offered
457Bearings (requirement of one isolator)
458Current carrying assembly 2000A total (requirement of one isolator)
459Motor with gear assembly and bevel gear assembly.
460Relays, power contactors, MCB’s switch fuses, push buttons and resistors, timers, key inter lock for electrical control circuit as per approved schematic-- Each Set containing one no. of each type and rating as offered
461Add: Any other supply item, if any, bidder may require completing the substation as per specification requirements.
462Auto Transformer:
463220/132 kV, 160 MVA Auto Transformer with all accessories (excluding transformer Oil) as per technical specification
464Insulating Oil for 160 MVA 220/132 kV Auto Transformer as per S-I , (1) above
465Digital RTCC Panel consisting of Digital RTCC relay as per technical Specification for transformers at S-I (1) above
466Power Transformer:
467132/33 kV, 50 MVA Power Transformer with all accessories (excluding transformer Oil) as per technical specification
468Insulating Oil for 50 MVA 132/33 kV Power Transformer S-II (4) above
469Digital RTCC Panel consisting of Digital RTCC relay as per technical Specification for transformers S-II, (4) above
470Circuit Breakers
471220 kV Circuit Breakers
472220kV circuit breakers (3 Ph.) Along with support Structure
4732500 A, 50 kA
474132 kV Circuit Breakers
475132 kV circuit breakers (3 Ph.) Along with support Structure
4761250 A, 40 kA
47733 kV Circuit Breakers
47833 kV circuit breakers (3 Ph.) Along with support Structure
4791600 A, 31.5 kA
480Instrument Transformers
481Capacitor Voltage Transformer
482Single-Phase, 220 kV, 4400 pf CVT
483Single Phase 132 kV , 4400 pf CVT
48433 kV Potential Transformer
48533/√3 kV /110-110√3
486Current Transformer (1-Phase)
487220 kV CT
4881000/1 A, 5C
489132 kV CT
4901000/1 A, 3C
491500/1 A, 3C
49233 kV CT
4931000/1 A, 4C
494500/1A, 2C
495C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)
496New Substation
497Control Panel for 220 kV Transformer (220 kV Side) Type: SAS-THCB
498Relay Panel for 220 kV Transformer (for both HV & MV) Type: SAS-THRB
499Control Panel for 220 kV Feeder Type: SAS-FCB
500Relay Panel for 220 kV Feeder Type: SAS-FRB
501Control Panel for 220 kV Bus Coupler Type: SAS-BCCB
502Relay Panel for 220 kV Bus Coupler Type: SAS-BCRB
503220 kV Busbar Protection Relay Panel Type: SAS-BBRB
504Control Panel for 220 kV Transformer (132 kV Side) Type: SAS-TLCB
505Relay Panel for 220 kV Transformer (132 kV Side) Type: SAS-TLRB
506Control and Relay Panel for 1x 50/31.5/25 MVA, 132/33 kV Power Transformer Type SAS-TCRA
507Control Panel for 132 kV Feeder Type SAS-FCA
508Relay Panel for 132 kV Feeder Type SAS-FRA
509Control and Relay Panel for 132 kV Bus-Coupler Type SAS-BCRA
510Control and Protection Panel for 33 kV Feeder (I/C, O/G)/Bus-coupler/ Capacitor Bank [For TWIN FEEDER/BAY] Type-FCRD
511Station HMI [Industrial grade Computer with 21\\"TFT monitor as per specification requirements]
512Station HMI (Hot Standby)[Industrial grade Computer with 21\\"TFT monitor as per specification requirements]
513HMI View Node[Industrial grad Computer with 21\\"TFT monitor as per specification requirements]
514A3 Size B&W Laser Printer
515Substation Automation System Network Panel Type SAS-NW
516Modems (both sending and Receiving End) for communication to RCC & Sub SLDC for PLCC]
517Data Concentrator Unit (DCU) at Substation for RAS mounted in suitable enclosure & fully wired
518Software: Application as well as System Software as per specification requirements for various hardware elements for meeting of functional requirement of the specification.
519Substation Auxiliary Monitoring Panel Type SAS-SAMP
520Other Items:
521Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements.
522Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards.
523Surge Arresters
524220 kV LA
525132 kV LA
52633 kV LA
527Substation LT Transformer
52833/ 0.433 kV, 250 kVA LT transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil
529Batteries & Battery Charger
530Batteries (Sizing shall be as per requirement of technical specification)
531220 V [Min. 600 AH]
53248 V [Min. 600 AH]
533Battery Charger System
534220 V Float and Boost
53550 V Float and Boost
536Lighting System
537Outdoor Lighting & other Works
538Lighting Fixture Type FL-1
539Lighting Fixture Type FL-2
540Outdoor Receptacle
541Type-RP
542Type-RO
543Substation Premises Lighting
544Lighting poles
545Type-L1
546Type-D1
547Street Lighting Type-SL-L1 for mounting on poles
548Street Lighting Type-SL-D1 for mounting on Poles
549Sub-Lighting Boxes/Panels Type -SLP at Lighting Mast and Other Loaction as designated complete with all controgears and accessories, items etc.
550Lighting Panel Type ACP-2 as per technical specification
551Lighting Panel Type ACP-3 as per technical specification
552Indoor Lighting & Other Works
553Electrification
554Electric Fitting (if not covered under Civil Works) with G.I. Conduit, Junction Boxes, pull out boxes, copper wiring, Modular Switchboards, Modular Switches, GI Wire (16SWG) etc. for control room, Hall and administrative office building as per the requirements of the specifications
555Illumiation
556Lighting fixtures and Receptacles (including accessories/ materials etc. as per requirement alongwith complete accessories and mounting arrangements)
557Indoor Lignting Panels
558Lighting Panel (Indoor) Type ACP-1 as per technical specification
559Lighting Panel (Indoor) Type DCP as per technical specification
560Wall mounted fans Approx. 400 mm sweep
561Ceiling Fan - Approx. 1400mm sweep with electronic Step regulator
562Exhaust Fans
563Fire Fighting System
564DCP Type
565i) 5 Kg.
566ii) 10 Kg.
567Carbon di oxide type – 6 Liters.
568Foam Type- 9 Liters
569Sand type
570i) GI Buckets 9 liters capacity
571ii) Steel Stands for four buckets
572Air Conditioning System
573Air Conditioning for the Rooms specified in the specifications
5741.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building]
575Power Cables(XLPE)
5761Cx630 sq.mm
5773.5Cx300 sq.mm
578Power Cable(PVC)
5791Cx150 sq.mm
5803.5Cx70 sq.mm
5813.5Cx35 sq.mm
5824Cx16 sq.mm
5834C x 6 Sq. mm
5842C x 6 Sq. mm
585Control Cable (PVC)
5864 CX4 Sq. mm
5875Cx2.5 sq.mm
5887Cx2.5 sq.mm
58910Cx2.5 sq.mm
59014Cx2.5 sq.mm
59119Cx2.5 sq.mm
592Substation Structures
593Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]:
594NON Standard Pipe support Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for Pipe support structure as per specification requirements]:
595Isolators
596220 kV (3-Phase) (Horizontal DOUBLE BREAK)
5971600A, 50KA, isolator with one E/S
598Post insulators for above Isolator
5991600A, 50KA, isolator with two E/S
600Post insulators for above Isolator
6011600A, 50KA, isolator without E/S
602Post insulators for above Isolator
6031600A, 50KA, isolator without E/S (TANDEM Type)
604Post insulators for above Isolator
605132 kV (3-Phase) (Horizontal DOUBLE BREAK)
6061250A, isolator with one E/S
607Post insulators for above Isolator
6081250A isolator without E/S
609Post insulators for above Isolator
61033 kV (3-Phase) (Horizontal DOUBLE BREAK)
6111250A, isolator without E/S
612Post insulators for above Isolator
613800 A isolator without E/S
614Post insulators for above Isolator
615800A isolator with E/S
616Post insulators for above Isolator
617Switchyard Erection
618Busbar & Interconnections
619New Substation/ Switchyard
620220 kV Switchyard Works:
621Main-I Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/Porcelain Long Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]
622Main-II Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Pocelain Long Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]
623Aux Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string(DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]
624220 kV Overhead Jack Bus (for DMT Layout) on Twin ACSR Zebra(Bus-Coupler Bay)/ Single ACSR Zebra (Transformer/ Line on ACSR Zebra) with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
625Twin ACSR Zebra
626Single ACSR Zebra
627Equipment Interconnections to Main Bus, Overhead Bus including Single ACSR Zebra (for Line), Twin ACSR Zebra (forTransformer bay & B/C Bay), bus-bar materials, clamps, connectors, spacers, corona shields, including equipment connectors, Junction box including of all accessories etc. for the following:
628220 kV DMT-type layout
629Line bay
630Transformer bay
631Bus-Coupler
632Bus CVT Interconnections to Main Buses including Single ACSR Zebra, clamps, connectors, junction box including of all accessories etc.
633132 kV Switchyard Works:
634Main Bus: 132 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulator, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays]
635Aux Bus: 132 kV Single ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays]
636132 kV Overhead Jack Bus (for Main & Aux Layout) on Twin ACSR Zebra(220 kV Transformer/Bus-Coupler Bay), Single ACSR Zebra(132 kV Transformer/Bus-Coupler Bay) Single ACSR Panther (Line on ACSR Panther) on Single Panther ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
637Twin ACSR Zebra
638Single ACSR Zebra
639Single Panther
640Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Zebra (Bus Sectionalizer/ 220 kV Transformer /Bus-Coupler Bay)/ Single ACSR Zebra (132 kV Transformer Bay) Single ACSR Panther ( Line on ACSR Panther), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:
641132 kV Main & Aux-type layout
642Line bay
643Transformer bay
644Bus-Coupler
645Bus CVT Interconnections to Main Bus including Single ACSR Zebra, clamps, connectors, junction box including of all accessories etc.
64633 kV Switchyard Works:
647Main Bus: 33 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string, Disc Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 5 bays+ Bus Coupler]
648Aux Bus: 33 kV Single ACSR Zebra Bus with conductor, busbar material, insulator string, Disc Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 5 bays+ Bus Coupler]
64933 kV Overhead Jack Bus for Transformer Incomer (for Main & Aux Layout) on Twin Zebra ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
650Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Panther ( Transformer /Bus-Coupler Bay)/ Single ACSR Panther ( Line bays), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:
65133 kV Main & Aux-type layout
652Line bay
653Transformer bay
654Bus-Coupler
655LT Transformer connection with ACSR Panther conductor, 33 kV DO Fuse Set alongwith required Clamp/connectors
656Bus PT Interconnections to Main Bus including Single ACSR Panther , clamps, connectors, junction box including of all accessories etc.
657Bus Post Insulators (BPI)
658220 kV
659132 kV
66033 kV
661Earthing & Lightning Protection System
662Main, Auxilary Earthmats, Risers etc. for complete earthing in the Switchyard Area
66328 mm Dia MS Rod
66428mm Dia, 3.2 M Long MS Rod Earth Electrodes Directly Driven.
66528mm Dia, 8 M Long MS Rod Earth Electrodes Directly Driven.
66628mm Dia, 3.2M Long MS Rod Earth Electrode in untreated pit with test link
66728 mm dia, 3000 mm long GS pipe electrodes with test links and treated earth pits with C.I. cover hinged to C.I. frame alongwith all associated civil works
66850X12 mm GS Flat
66950X6 mm GS Flat
670Earth Enhancing Compound for treated pits as above and other requirement as per specification
671Cleat type clamps(8mm thick) for earthing down conductor (10.98 mm dia), 50x12 mm GS Flat and 50x6 mm GS flat
672Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats
673Earth Wire for Shielding Protection of Switchyard
6747/3.15 Galvenized Steel Wire
675Earthwire tension clamps with D Shackle assembly
676PG calmp to suit 7/3.15 mm GS earth wire
677Cleat clamp on structure to suit 7/3.15 mm GS earth wire/ 50 X 12 mm GS Flat
678Pad clamp on structure to suit 7/3.15 mm earth wire and 75 x 12 GS flat
679Lug to suit 7/3.15 mm earth wire
680Other Clamps, Copper Earth Bond etc. as per layout diagram for erection of Earth Wire
681Bay Marshalling KIOSK
682200 way (Stud Type Connectors)
683AC Distribution Boxes (Outdoor Type)
684Outdoor AC Distbibution Box (Double Front type)
685Outdoor AC Distbibution Box (Single Front type)
686Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building]
687Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washers etc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works]
688LT Switchgear
689LT AC Main Panel
690LT AC Distribution Board
691Main Lighting Distribution Board
692Emergency Lighting Distribution Board
693220V DCDB
69448V DCDB
695PLCC EQUIPMENTS
696220 kV Wave trap (1250A, 0.5 mH, 40 kA)
697132 kV wave trap (1000A, 0.2 mH, 40 kA)
6984 kH to 16 kHz Channel Digitial PLCC Carrier terminal with digital protection coupler (DTPC) IEC/101/104 data and 4 W E&M speech applications .
6994 kH to 16 kHz Channel Digitial PLCC Carrier terminal with out digital protection coupler (DTPC) IEC/101/104 data and 4 W E&M speech applications .
700VFT equipment (Modem) suitable for transmission of Data through PLCC links based on frequency shift keying modulation techniques programmable for both baud rate from 50 Baud to 2400 Baud and center frequency through switches or jumpers (A.F. Shift Channel)
701Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
702Coupling Devices for Phase to Ground coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
703HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
704Microprocessor based 24/8 line Electronic Private Automatic Exchange (EPAX) with PLCC interphasing facility
705Telephone Sets (Push Button Type)
70610 pair Jelly Filled and armoured telephone cable with copper conductor of 0.5 mm
7075 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.5 mm
7085 Pair jelly filled un armoured telephone cable having copper conductor of Dia. 0.5 mm
709Add: Any other item bidder may require to complete the Electrical Service works as per specification requirements
710CIVIL WORKS
711TOWER/ EQUIPMENT FOUNDATIONS :
712TOWER/ EQUIPMENT FOUNDATIONS :
713MAIN MATERIAL/ ITEMS
714Circuit Breakers
715220 kV Circuit Breakers
716220kV circuit breakers (3 Ph.) Along with support Structure
7172500 A, 50 kA
718Instrument Transformers
719Capacitor Voltage Transformer
720Single-Phase, 220 kV, 4400 pf CVT
721Current Transformer (1-Phase)
722220 kV CT
7231000/1 A, 5C
724C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)
725Control Panel for 220 kV Feeder Type: SAS-FCB similar to existing control panel at 400 KV GSS, Jaipur South (PGCIL)
726Relay Panel for 220 kV Feeder Type: SAS-FRB similar to existing control panel at 400 KV GSS, Jaipur South (PGCIL)
727Software: Application as well as System Software as per specification requirements for various hardware elements for meeting of functional requirement of the specification and integration to existing RTU/SCADA and RAS System
728Other Items:
729Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements.
730Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards.
731Surge Arresters
732220 kV LA
733Power & control Cable Cable (PVC)
734Power & control Cable Cable (PVC)
735Substation Structures
736Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]:
737Isolators
738220 kV (3-Phase) (Horizontal DOUBLE BREAK)
7391600A, 50KA, isolator with one E/S
740Post insulators for above Isolator
7411600A, 50KA, isolator with two E/S
742Post insulators for above Isolator
7431600A, 50KA, isolator without E/S (TANDEM Type)
744Post insulators for above Isolator
745Switchyard Erection
746Busbar & Interconnections
747Line bays on Existing terminal Substations
748220 kV Switchyard Works:
749Bus Bar Materials, Clamps, discs and Insulators
750Bus Post Insulators (BPI)
751220 kV
752Earthing & Lightning Protection System
753Main, Auxilary Earthmats, Risers etc. for complete earthing in the Existing Switchyard Area
754Earthing & Lightning Protection System
755Bay Marshalling KIOSK
756200 way (Stud Type Connectors)
757Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building]
758Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washers etc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works]
759PLCC EQUIPMENTS
760220 kV Wave trap (1250A, 0.5 mH, 40 kA)
7614 KHZ to 16 Khz channel digital PLCC carrier terminal with digital protection coupler (DTPC) IEC 101/104 data and 4W E&M speech applications
762Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
763HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
7645 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.5 mm
7655 Pair jelly filled un armoured telephone cable having copper conductor of Dia. 0.5 mm
766Add: Any other supply item, if any, bidder may require completing the substation as per specification requirements.
767SERVICE+ETC+Civil
768220 kV Circuit Breakers
769220kV circuit breakers (3 Ph.) Along with support Structure
7702500 A, 50 kA
771Capacitor Voltage Transformer
772Single-Phase, 220 kV, 4400 pf CVT
773Current Transformer (1-Phase)
774220 kV CT
7751000/1 A, 5C
776C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)
777Control Panel for 220 kV Feeder Type: SAS-FCB similar to existing control panel at 400 KV GSS, Jaipur South (PGCIL)
778Relay Panel for 220 kV Feeder Type: SAS-FRB similar to existing control panel at 400 KV GSS, Jaipur South (PGCIL)
779Software: Application as well as System Software as per specification requirements for various hardware elements for meeting of functional requirement of the specification and integration to existing RTU/SCADA and RAS System
780Other Items:
781Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements.
782Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards.
783Surge Arresters
784220 kV LA
785Power and control cable
786Power and control cable
787Substation Structures
788Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]:
789Isolators
790220 kV (3-Phase) (Horizontal DOUBLE BREAK)
7911600A, 50KA, isolator with one E/S
792Post insulators for above Isolator
7931600A, 50KA, isolator with two E/S
794Post insulators for above Isolator
7951600A, 50KA, isolator without E/S (TANDEM Type)
796Post insulators for above Isolator
797Switchyard Erection
798Busbar & Interconnections
799Line bays on Existing terminal Substations
800220 kV Switchyard Works:
801Bus Bar Materials, Clamps, discs and Insulators
802Bus Post Insulators (BPI)
803220 kV
804Earthing & Lightning Protection System
805Main, Auxilary Earthmats, Risers etc. for complete earthing in the Switchyard Area
806Earthing & Lightning Protection System
807Bay Marshalling KIOSK
808200 way (Stud Type Connectors)
809Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building]
810Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washers etc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works]
811PLCC EQUIPMENTS
812220 kV Wave trap (1250A, 0.5 mH, 40 kA)
8134 KHZ to 16 Khz channel digital PLCC carrier terminal with digital protection coupler (DTPC) IEC 101/104 data and 4W E&M speech applications
814Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
815HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
8165 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.5 mm
8175 Pair jelly filled un armoured telephone cable having copper conductor of Dia. 0.5 mm
818Add: Any other item bidder may require to complete the Electrical Service works as per specification requirements
819CIVIL WORKS
820TOWER/ EQUIPMENT FOUNDATIONS :
821TOWER/ EQUIPMENT FOUNDATIONS :
822MAIN MATERIAL/ ITEMS
823Circuit Breakers
824132 kV Circuit Breakers
825132 kV circuit breakers (3 Ph.) Along with support Structure
8261250 A, 40 kA
827Instrument Transformers
828Capacitor Voltage Transformer
829Single Phase 132 kV , 4400 pf CVT
830Current Transformer (1-Phase)
831132 kV CT
832500/1 A, 3C
833C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)
834132 kV Feeder C&R Panel as per Specification (Conventional Type without BCU)
835Upgrade/ New Hardware & Software as required for integration to Existing RTU/SCADA and RAS System
836Other Items:
837Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements.
838Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards.
839Surge Arresters
840132 kV LA
8411.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building]
842Control Cable (PVC)
8434 CX4 Sq. mm
8444 CX2.5 Sq. mm
8456Cx2.5 sq.mm
84619Cx2.5 sq.mm
847Substation Structures
848Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]:
849Non-Standard type Pipe Support Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for Pipe Support structure as per specification requirements]
850Isolators
851132 kV (3-Phase) (Horizontal DOUBLE BREAK)
8521250A, isolator with one E/S
853Post insulators for above Isolator
8541250A isolator without E/S
855Post insulators for above Isolator
856Switchyard Erection
857Busbar & Interconnections
858Line bays on Existing terminal Substations
859132 kV Switchyard Works:
860132 kV Overhead Jack Bus (for Main & Aux Layout) on Twin ACSR Zebra(220 kV Transformer/Bus-Coupler Bay), Single ACSR Zebra(132 kV Transformer/Bus-Coupler Bay) Single ACSR Panther (Line on ACSR Panther) on Single Panther ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
861Single Panther
862Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Zebra (Bus Sectionalizer/ 220 kV Transformer /Bus-Coupler Bay)/ Single ACSR Zebra (132 kV Transformer Bay) Single ACSR Panther ( Line on ACSR Panther), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:
863132 kV Main & Aux-type layout
864Line bay
865Bus Post Insulators (BPI)
866132 kV
867Earthing & Lightning Protection System
868Main, Auxilary Earthmats, Risers etc. for complete earthing in the Switchyard Area
86928 mm Dia MS Rod
87050X12 mm GS Flat
871Earth Enhancing Compound for treated pits as above and other requirement as per specification
872Cleat type clamps(8mm thick) for earthing down conductor (10.98 mm dia), 50x12 mm GS Flat and 50x6 mm GS flat
873Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats
874Earth Wire for Shielding Protection of Switchyard
875Other Clamps, Copper Earth Bond etc. as per layout diagram for erection of Earth Wire
876Bay Marshalling KIOSK
877200 way (Stud Type Connectors)
878Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building]
879Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washers etc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works]
880PLCC EQUIPMENTS
881132 kV wave trap (100A, 0.2 mH, 40 kA)
8824 kH to 16 kHz Channel Digitial PLCC Carrier terminal with out digital protection coupler (DTPC) IEC/101/104 data and 4 W E&M speech applications .
883Coupling Devices for Phase to Ground coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
8845 Pair jelly filled un armoured telephone cable having copper conductor of Dia. 0.5 mm
885HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
886Add: Any other supply item, if any, bidder may require completing the substation as per specification requirements.
887SERVICE+ETC+Civil
888132 kV Circuit Breakers
889132 kV circuit breakers (3 Ph.) Along with support Structure
8901250 A, 40 kA
891Capacitor Voltage Transformer
892Single Phase 132 kV , 4400 pf CVT
893Current Transformer (1-Phase)
894132 kV CT
895500/1 A, 3C
896C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)
897132 kV Feeder C&R Panel as per Specification (Conventional Type without BCU)
898Upgrade/ New Hardware & Software as required for integration to Existing RTU/SCADA and RAS System
899Other Items:
900Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements.
901Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards.
902Surge Arresters
903132 kV LA
9041.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building]
905Control Cable (PVC)
9064 CX4 Sq. mm
9074 CX2.5 Sq. mm
9086Cx2.5 sq.mm
90919Cx2.5 sq.mm
910Substation Structures
911Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]:
912Non-Standard type Pipe Support Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for Pipe Support structure as per specification requirements]
913Isolators
914132 kV (3-Phase) (Horizontal DOUBLE BREAK)
9151250A, isolator with one E/S
916Post insulators for above Isolator
9171250A isolator without E/S
918Post insulators for above Isolator
919Switchyard Erection
920Busbar & Interconnections
921Line bays on Existing terminal Substations
922132 kV Switchyard Works:
923132 kV Overhead Jack Bus (for Main & Aux Layout) on Twin ACSR Zebra(220 kV Transformer/Bus-Coupler Bay), Single ACSR Zebra(132 kV Transformer/Bus-Coupler Bay) Single ACSR Panther (Line on ACSR Panther) on Single Panther ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
924Single Panther
925Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Zebra (Bus Sectionalizer/ 220 kV Transformer /Bus-Coupler Bay)/ Single ACSR Zebra (132 kV Transformer Bay) Single ACSR Panther ( Line on ACSR Panther), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:
926132 kV Main & Aux-type layout
927Line bay
928Bus Post Insulators (BPI)
929132 kV
930Earthing & Lightning Protection System
931Main, Auxilary Earthmats, Risers etc. for complete earthing in the Switchyard Area
93228 mm Dia MS Rod
93350X12 mm GS Flat
934Earth Enhancing Compound for treated pits as above and other requirement as per specification
935Cleat type clamps(8mm thick) for earthing down conductor (10.98 mm dia), 50x12 mm GS Flat and 50x6 mm GS flat
936Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats
937Earth Wire for Shielding Protection of Switchyard
938Other Clamps, Copper Earth Bond etc. as per layout diagram for erection of Earth Wire
939Bay Marshalling KIOSK
940200 way (Stud Type Connectors)
941Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building]
942Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washers etc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works]
943PLCC EQUIPMENTS
944132 kV wave trap (1000A, 0.2mH, 40 kA)
9454 kH to 16 kHz Channel Digitial PLCC Carrier terminal with out digital protection coupler (DTPC) IEC/101/104 data and 4 W E&M speech applications .
946Coupling Devices for Phase to Ground coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
947HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
9485 Pair jelly filled un armoured telephone cable having copper conductor of Dia. 0.5 mm
949Add: Any other item bidder may require to complete the Electrical Service works as per specification requirements
950CIVIL WORKS
951TOWER/ EQUIPMENT FOUNDATIONS :
952TOWER/ EQUIPMENT FOUNDATIONS :
953MAIN MATERIAL/ ITEMS
954Circuit Breakers
955132 kV Circuit Breakers
956132 kV circuit breakers (3 Ph.) Along with support Structure
9571250 A, 40 kA
958Instrument Transformers
959Capacitor Voltage Transformer
960Single Phase 132 kV , 4400 pf CVT
961Current Transformer (1-Phase)
962132 kV CT
963500/1 A, 3C
964C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)
965132 kV Feeder C&R Panel as per Specification (Conventional Type without BCU)
966Upgrade/ New Hardware & Software as required for integration to Existing RTU/SCADA and RAS System
967Other Items:
968Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements.
969Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards.
970Surge Arresters
971132 kV LA
9721.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building]
973Control Cable (PVC)
9744 CX4 Sq. mm
9754Cx2.5 sq.mm
9766Cx2.5 sq.mm
97719Cx2.5 sq.mm
978Substation Structures
979Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]:
980Non-Standard type Pipe Support Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for Pipe Support structure as per specification requirements]
981Isolators
982132 kV (3-Phase) (Horizontal DOUBLE BREAK)
9831250A, isolator with one E/S
984Post insulators for above Isolator
9851250A isolator without E/S
986Post insulators for above Isolator
987Switchyard Erection
988Busbar & Interconnections
989Line bays on Existing terminal Substations
990132 kV Switchyard Works:
991132 kV Overhead Jack Bus (for Main & Aux Layout) on Twin ACSR Zebra(220 kV Transformer/Bus-Coupler Bay), Single ACSR Zebra(132 kV Transformer/Bus-Coupler Bay) Single ACSR Panther (Line on ACSR Panther) on Single Panther ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
992Single Panther
993Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Zebra (Bus Sectionalizer/ 220 kV Transformer /Bus-Coupler Bay)/ Single ACSR Zebra (132 kV Transformer Bay) Single ACSR Panther ( Line on ACSR Panther), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:
994132 kV Main & Aux-type layout
995Line bay
996Bus Post Insulators (BPI)
997132 kV
998Earthing & Lightning Protection System
999Main, Auxilary Earthmats, Risers etc. for complete earthing in the Switchyard Area
100028 mm Dia MS Rod
100150X12 mm GS Flat
1002Earth Enhancing Compound for treated pits as above and other requirement as per specification
1003Cleat type clamps(8mm thick) for earthing down conductor (10.98 mm dia), 50x12 mm GS Flat and 50x6 mm GS flat
1004Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats
1005Earth Wire for Shielding Protection of Switchyard
1006Other Clamps, Copper Earth Bond etc. as per layout diagram for erection of Earth Wire
1007Bay Marshalling KIOSK
1008200 way (Stud Type Connectors)
1009Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building]
1010Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washers etc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works]
1011PLCC EQUIPMENTS
1012132 kV wave trap (1000A, 0.2mH, 40 kA)
10134 kH to 16 kHz Channel Digitial PLCC Carrier terminal with out digital protection coupler (DTPC) IEC/101/104 data and 4 W E&M speech applications .
1014Coupling Devices for Phase to Ground coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
10155 Pair jelly filled un armoured telephone cable having copper conductor of Dia. 0.5 mm
1016HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
1017Add: Any other supply item, if any, bidder may require completing the substation as per specification requirements.
1018SERVICE+ETC+Civil
1019132 kV Circuit Breakers
1020132 kV circuit breakers (3 Ph.) Along with support Structure
10211250 A, 40 kA
1022Capacitor Voltage Transformer
1023Single Phase 132 kV , 4400 pf CVT
1024Current Transformer (1-Phase)
1025132 kV CT
1026500/1 A, 3C
1027C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)
1028132 kV Feeder C&R Panel as per Specification (Conventional Type without BCU)
1029Upgrade/ New Hardware & Software as required for integration to Existing RTU/SCADA and RAS System
1030Other Items:
1031Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements.
1032Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards.
1033Surge Arresters
1034132 kV LA
10351.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building]
1036Control Cable (PVC)
10374 CX4 Sq. mm
10384Cx2.5 sq.mm
10396Cx2.5 sq.mm
104019Cx2.5 sq.mm
1041Substation Structures
1042Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]:
1043Non-Standard type Pipe Support Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for Pipe Support structure as per specification requirements]
1044Isolators
1045132 kV (3-Phase) (Horizontal DOUBLE BREAK)
10461250A, isolator with one E/S
1047Post insulators for above Isolator
10481250A isolator without E/S
1049Post insulators for above Isolator
1050Switchyard Erection
1051Busbar & Interconnections
1052Line bays on Existing terminal Substations
1053132 kV Switchyard Works:
1054132 kV Overhead Jack Bus (for Main & Aux Layout) on Twin ACSR Zebra(220 kV Transformer/Bus-Coupler Bay), Single ACSR Zebra(132 kV Transformer/Bus-Coupler Bay) Single ACSR Panther (Line on ACSR Panther) on Single Panther ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
1055Single Panther
1056Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Zebra (Bus Sectionalizer/ 220 kV Transformer /Bus-Coupler Bay)/ Single ACSR Zebra (132 kV Transformer Bay) Single ACSR Panther ( Line on ACSR Panther), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:
1057132 kV Main & Aux-type layout
1058Line bay
1059Bus Post Insulators (BPI)
1060132 kV
1061Earthing & Lightning Protection System
1062Main, Auxilary Earthmats, Risers etc. for complete earthing in the Switchyard Area
106328 mm Dia MS Rod
106450X12 mm GS Flat
1065Earth Enhancing Compound for treated pits as above and other requirement as per specification
1066Cleat type clamps(8mm thick) for earthing down conductor (10.98 mm dia), 50x12 mm GS Flat and 50x6 mm GS flat
1067Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats
1068Earth Wire for Shielding Protection of Switchyard
1069Other Clamps, Copper Earth Bond etc. as per layout diagram for erection of Earth Wire
1070Bay Marshalling KIOSK
1071200 way (Stud Type Connectors)
1072Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building]
1073Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washers etc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works]
1074PLCC EQUIPMENTS
1075132 kV wave trap (1000A, 0.2 mH, 40 kA)
10764 kH to 16 kHz Channel Digitial PLCC Carrier terminal with out digital protection coupler (DTPC) IEC/101/104 data and 4 W E&M speech applications .
1077Coupling Devices for Phase to Ground coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.
1078HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.
10795 Pair jelly filled un armoured telephone cable having copper conductor of Dia. 0.5 mm
1080Add: Any other item bidder may require to complete the Electrical Service works as per specification requirements
1081CIVIL WORKS
1082TOWER/ EQUIPMENT FOUNDATIONS :
1083TOWER/ EQUIPMENT FOUNDATIONS :
1084MAIN MATERIAL/ ITEMS
1085Circuit Breakers
108633 kV Circuit Breakers
108733 kV circuit breakers (3 Ph.) Along with support Structure
10881600 A, 31.5 kA
1089Current Transformer (1-Phase)
109033 kV CT
1091250/1 A, 2C
1092C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)
1093Control and Protection Panel for 33 kV Feeder (I/C, O/G)/Bus-coupler/ Capacitor Bank [For TWIN FEEDER/BAY] Type-FCRD
1094Other Items:
1095Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements.
1096Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards.
10971.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building]
1098Control Cable (PVC)
10994 CX4 Sq. mm
11003Cx2.5 sq.mm
11015Cx2.5 sq.mm
110214Cx2.5 sq.mm
110319Cx2.5 sq.mm
1104Substation Structures
1105Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]:
1106Isolators
110733 kV (3-Phase) (Horizontal DOUBLE BREAK)
1108800 A isolator without E/S
1109Post insulators for above Isolator
1110800A isolator withE/S
1111Post insulators for above Isolator
1112Switchyard Erection
1113Busbar & Interconnections
1114Line bays on Existing terminal Substations
111533 kV Switchyard Works:
111633 kV Overhead Jack Bus for Capacitor Bank (for Main & Aux Layout) on Twin Zebra ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
1117Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Panther ( Transformer /Bus-Coupler Bay)/ Single ACSR Panther ( Line bays), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:
111833 kV Main & Aux-type layout
1119Capacitor Bank bay
1120Bus Post Insulators (BPI)
112133 kV
1122Earthing & Lightning Protection System
1123Main, Auxilary Earthmats, Risers etc. for complete earthing in the Switchyard Area
1124MS Channel 100x50x6 MM
112528 MM MS Rod
112650x12 mm GS Flat
1127Earth Enhancing Compound for treated pits as above and other requirement as per specification
1128Cleat type clamps(8mm thick) for earthing down conductor (10.98 mm dia), 50x12 mm GS Flat and 50x6 mm GS flat
1129Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats
1130Earth Wire for Shielding Protection of Switchyard
1131Other Clamps, Copper Earth Bond etc. as per layout diagram for erection of Earth Wire
1132Bay Marshalling KIOSK
1133200 way (Stud Type Connectors)
1134Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building]
1135Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washers etc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works]
1136Capacitor Bank Equipments
113733 kV 5.43 MVAR Capacitor Bank with structure
1138Neutral current Transformer(NCT)(1A/5A)
1139Series reactors (1-phase) for parallel operation of two double star connected capacitor banks of 2.72 MVAR rating
1140Add: Any other supply item, if any, bidder may require completing the substation as per specification requirements.
1141Service+ETC+Civil
1142Circuit Breakers
114333 kV Circuit Breakers
114433 kV circuit breakers (3 Ph.) Along with support Structure
11451600 A, 31.5 kA
1146Current Transformer (1-Phase)
114733 kV CT
1148250/1 A, 2C
1149C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)
1150Control and Protection Panel for 33 kV Feeder (I/C, O/G)/Bus-coupler/ Capacitor Bank [For TWIN FEEDER/BAY] Type-FCRD
1151Other Items:
1152Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements.
1153Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards.
11541.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building]
1155Control Cable (PVC)
11564 CX4 Sq. mm
11573Cx2.5 sq.mm
11585Cx2.5 sq.mm
115914Cx2.5 sq.mm
116019Cx2.5 sq.mm
1161Substation Structures
1162Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]:
1163Isolators
116433 kV (3-Phase) (Horizontal DOUBLE BREAK)
1165800 A isolator without E/S
1166Post insulators for above Isolator
1167800A isolator withE/S
1168Post insulators for above Isolator
1169Switchyard Erection
1170Busbar & Interconnections
1171Line bays on Existing terminal Substations
117233 kV Switchyard Works:
117333 kV Overhead Jack Bus for Capacitor Bank (for Main & Aux Layout) on Twin Zebra ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]
1174Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Panther ( Transformer /Bus-Coupler Bay)/ Single ACSR Panther ( Line bays), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:
117533 kV Main & Aux-type layout
1176Capacitor Bank bay
1177Bus Post Insulators (BPI)
117833 kV
1179Earthing & Lightning Protection System
1180Main, Auxilary Earthmats, Risers etc. for complete earthing in the Switchyard Area
1181MS Channel 100x50x6 MM
118228 MM MS Rod
118350x12 mm GS Flat
1184Earth Enhancing Compound for treated pits as above and other requirement as per specification
1185Cleat type clamps(8mm thick) for earthing down conductor (10.98 mm dia), 50x12 mm GS Flat and 50x6 mm GS flat
1186Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats
1187Earth Wire for Shielding Protection of Switchyard
1188Other Clamps, Copper Earth Bond etc. as per layout diagram for erection of Earth Wire
1189Bay Marshalling KIOSK
1190200 way (Stud Type Connectors)
1191Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building]
1192Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washers etc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works]
1193Capacitor Bank Equipments
119433 kV 5.43 MVAR Capacitor Bank
1195Neutral current Transformer(NCT)(1A/5A)
1196Series reactors (1-phase) for parallel operation of two double star connected capacitor banks of 2.72 MVAR rating
1197CIVIL WORKS
1198TOWER/ EQUIPMENT FOUNDATIONS : Please Enable Macros to View BoQ information
1199TOWER/ EQUIPMENT FOUNDATIONS : Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56894075
AUTHORITY Government Departments
TENDER VALUE 51.23 Crore
LAST DATE 07-09-2026
Authority
Authority Name Rajasthan Rajya Vidhyut Prasaran Nigam Limited
Work Description Tender for Construction Of 220/132 Kv, 1X160 Mva; 132/33 Kv, 1X40/50 Mva Substation At Malpura Including Survey Supply Of All Equipments/Materials, Erection (Including Civil Works), Testing And Commissioning On Turnkey Basis Against Specification No. Rvpn/Ehv/Bn-9019002607.
Basic Detail
Tender No RVPN/EHV/BN9019002606
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 07 Aug 2026
Submission Date 07 Sep 2026
Open Date 08 Sep 2026
Finance
Tender Value 51.23 Crore
Tender Fee 23600
EMD 1.02 Crore
Exemption Not Available
Document List
BOQ_1036523.xls
d21a45a2-48b9-42b0-9273-cfaaa865167b.html
ELP_Drawings.pdf
Project_section_GSS.pdf
Technical_Malpura_GSS_VOL_1.pdf
Tendernotice_1 (31).pdf
Vol-1commercial_malpura.pdf
Vol_III_Civil.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 27 days
Sep 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 28 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1036523.xls

html

d21a45a2-48b9-42b0-9273-cfaaa865167b.html

pdf

ELP_Drawings.pdf

pdf

Project_section_GSS.pdf

pdf

Technical_Malpura_GSS_VOL_1.pdf

pdf

Tendernotice_1 (31).pdf

pdf

Vol-1commercial_malpura.pdf

pdf

Vol_III_Civil.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders