Tender For Providing 1 No. 1.5Tr And 1 No. 2Tr Split Type Air Conditioner Units, Ac Plug Points And Power Mains Arrangements To Office Room And Male Op Room At Government Hospotal At Kadayanallur In Tenkasi District.
Tender Value
1.48 Lakhs
Estimated cost
Bid Submission
20 Aug 2026
5 days left
EMD
1500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tenkasi → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Providing 1 No. 1.5Tr And 1 No. 2Tr Split Type Air Conditioner Units, Ac Plug Points And Power Mains Arrangements To Office Room And Male Op Room At Government Hospotal At Kadayanallur In Tenkasi District.
BOQ
| Sl. No. | Item Description |
| 1 | Supply and errection of 1.5 Ton 3 STAR rated Carrier make Duractiv Split type Airconditioners (4500 K.cal/hr) GI sheet (ABS, HIPS plastic Fitted with Hermetically,scaled compressors operating refrigerant R-22/non CFC suitable (for floor mounting and ceiling mounting) confiriming to IS 1391 (part2) 92 (AMDT .1)(except power consumption Norms) suitable,operation on 230V,50HZ single phase AC supply. |
| 2 | a. Mounting/Filting Indoor & Outdoor units at their respective location.b. Laying Refrigerant pipe line of required length connecting both units units after drilling hole/ holes in the wall,if required .Thckness of copper tubing shall not be less than 0.7 mm.c. Insulating the suction pipe with expanded polyethelene foam 5mm tubing. |
| 3 | d. Laying 15mm dia flexible pvc drain pipe to throw out the condensate water being formed in the indoor unit.e. Leak testing the entire system unit.f. Charging Refrigerant gas in the unit.g. Suitable electric wiring & switch should be provided with in 3 meters of the location of unit. |
| 4 | Supply and errection of 1.5 Ton 3 STAR rated Carrier make Duractiv Split type Airconditioners (6000 K.cal/hr) GI sheet (ABS, HIPS plastic Fitted with Hermetically,scaled compressors operating refrigerant R-22/non CFC suitable (for floor mounting and ceiling mounting) confiriming to IS 1391 (part2) 92 (AMDT .1)(except power consumption Norms) suitable,operation on 230V,50HZ single phase AC supply. |
| 5 | a.Mounting/Filting Indoor & Outdoor units at their respective locationb.Laying Refrigerant pipe line of required length connecting both units units after drilling hole/ holes in the wall,if required .Thckness of copper tubing shall not be less than 0.7 mmc.Insulating the suction pipe with expanded polyethelene foam 5mm tubing. |
| 6 | d. Laying 15mm dia flexible pvc drain pipe to throw out the condensate water being formed in the indoor unit.e. Leak testing the entire system unit.f. Charging Refrigerant gas in the unit.g. Suitable electric wiring & switch should be provided with in 3 meters of the location of unit. |
| 7 | Supplying and installation of 4KVA electronic wide range automatic voltage stabilizer (V. Guard / equ. 500/ equ. ) with input range of 140 - 270 V and out put voltage cut off and 3 minutes time delay relay with demonstration. |
| 8 | Supplying and installation of 5KVA electronic wide range automatic voltage stabilizer (V. Guard / equ. 500/ equ. ) with input range of 140 - 270 V and out put voltage cut off and 3 minutes time delay relay with demonstration. |
| 9 | Supply and laying of 5/8\\" and 3/8\\" copper pipe |
| 10 | Supply and fixing of MS stand for fixing outdoor unit |
| 11 | Supply and fixing of water drain pipe line (1” PVC Pipe) |
| 12 | Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug on wall with earth connection (For AC Plug) |
| 13 | Supply and fixing of 32A Double pole MCB in sheet steel enclosure on wall and making good of the concealed portion with earth connection.[The MCB and metal enclosure should be of Legrand (MDS) / Hager (L&T) make]. |
| 14 | Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 No 32A 4P MCB as incoming and 12 Nos 6A to 32A SP MCB as outgoing on wall with Earth connection only. Higher End |
| 15 | Shifting of 2TR split type AC indoor and outdoor unit from one location to another including dismantling, shifting, fixing, refilling of refridgerant gas and testing. |
| 16 | Supply and fixing of 400mm sweep wall mounting oscillationg fan with inbuilt speed controlling regulator on the existing wall. |
| 17 | Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting. |
| 18 | Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour. |
| 19 | GST Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysAug 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender