Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #56890524

Tender For Provn Of Ladies/Gents Toilets At Small Arms Ranges, Addn/Altn To Certain Toilet At Offrs Mess, Provn Of Garden Lights At Certain Locations, Provision Of Complete Re-Wiring Of 41 Dsc Guard Post For Stand By Light Supply And Provn Of Qty 04

Issued by Statutory Bodies & Commissions/Committees · Darjeeling, West Bengal
Tender Value
30.89 Lakhs
Estimated cost
Bid Submission
28 Aug 2026
15 days left
EMD
61780
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Darjeeling → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Ladies/Gents Toilets At Small Arms Ranges, Addn/Altn To Certain Toilet At Offrs Mess, Provn Of Garden Lights At Certain Locations, Provision Of Complete Re-Wiring Of 41 Dsc Guard Post For Stand By Light Supply And Provn Of Qty 04 Acs At Gdcc At Af Stn Bagdogra Under Ge (Af) Bagdogra

BOQ

Name of Work:- Provn of ladies/gents toilets at Small Arms Ranges, Addn/Altn to certain toilet at Offrs Mess, Provn of garden lights at certain locations, Provision of complete re-wiring of 41 DSC guard post for stand by light supply and provn of Qty 04 ACs at GDCC at AF Stn Bagdogra under GE (AF) Bagdogra
Sl. No. Item Description
1Surface dressing n.exc (not exceeding) 15 cm deep and getting out soft/loose soil complete all as specified and directed.
2Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and not exc. 1.5 m. in depth and getting out in soft/loose soil complete all as specified and directed.
3Returning filling in , including spreading, levelling, watering & well ramming in layers not exc 25 cm complete all as specified and directed.
4Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
5M&L Cement concrete 1:4:8 (Type D2) in foundations, filling and mass concrete all as specified and directed.
6M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
7M&L for chequered cement concrete tiles 30cmx30cmx25mm thick , set, jointed & pointed in neat cement slurry, in floor with grey cement and no pigment screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:4 mortar complete all as specified directed.
8M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including bituminium gap filling necessary form work, complete all specified.
9M&L TMT bar 10 mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including steel wire (annealed) not less than 0.90 mm dia as reinforcement complete all as specified and directed.
10All as per Ser item no 9 above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
11Use and waste of formwork to sides of concrete foundation, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beam as rough finish and similar wrok vertical or to batter complete all as specified and directed
12Use and waste of formwork to sides of and soffits of floor or roof beams beam haunchings girders, bressummers ,lintels cantilevers, shelves including supports, overhangs, etc also splays between floors and beams complete all as specified and directed.
13Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions as in rough finished surfaces of concrete complete all as specified and directed.
14Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide as in rough finished surfaces of concrete complete all as specified and directed.
15M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick rough finished in flat surface complete all as specified and directed.
16M&L for RCC 1:2:4 type B-1 (Nominal mix) (using 20 mm graded aggregate) as in foundation, footing, foundation beam, plinth beam, base for columns, etc. complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately.
17M&L for RCC 1:2:4 type B-1 (Nominal mix) (using 20 mm graded aggregate)as in columns, etc. complete all as specified and directed (Note: Reinforcement shall be measured and paid separately.
18M&L for providing reinforced cement concrete (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
19M&L for RCC 1:2:4 type B-1 (Nominal mix) (using 20 mm graded aggregate) as in beams, cantilevers, bressumm ers, lintels over 1.5m span complete all as specified and directed (Note: Reinforcement shall be measured and paid separately.
20Supply only Integral water proofing compound (WPC), conforming to IS and as approved, complete all as specified and directed.
21M&L for brick work sub class 'B' bricks, straight or curved on plan, exc 6m mean radius built in CM 1:6 complete all as specified and directed.
22M&L for brick work sub class 'B' bricks, straight or curved on plan, exc 6 m mean radius built in CM 1:4 complete all as specified and directed.
23M&L for half brick work in CM 1:4 complete all as specified and directed.
24M&L for Steel work in tubular/angle trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
25M&L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with J hook and fixing arrangement complete all as specified and directed.
26M&L for Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
27M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
28M&L for Powder coated galvanised iron snap grid frame work of size 600 x 600 mm for false ceiling comprising of Main runner 'T' section of size 38mm x 24mm x 0.40mm thickness, Cross 'T' of size 29mm x 24mm x 0.3mm thickness and wall angle of size 24mm x 24mm x 0.43mm thick suspended with 2mm dia GI wire from purlin @ 1.20m c/c and fixed with 4mm thick designer ceiling boards complete all as specified and directed.
29M&L Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specific ratio & drawing complete all as specified and directed.
30M&L factory made solid PVC door Frame of size 50 mmx47 mm made out of 5mm thick wood grain printed PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with printed sheet reinforced MS square tube supplying & fixing in opening as per specification & drawing complete all as specified and directed.
31S&F chromium plated hand shower health faucet ABB body with 8 mm dia. 1.00 m long CP flexible pipe 15 mm bore with wall hook complete all as specified and directed.
32S&F connection pipe, chromium plated, 450mm long with PTMT nuts at both ends 15 mm dia, suitable for gyser complete all as specified and directed.
33S&F for CP 15mm bore angular stop cock with wall flange fixed with screws complete all as specified and directed.
34S&F in repair, 15 mm bore chromium plated fancy type long body bib tap with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
35S & F corner shelf of PTMT fixed with chromium plated brass screws and wooden / plastic cleats (Minimum weight 300 gms) complete all as specified and directed.
36S&F figured glass pin head 4.00 mm thick ordinary quality and glazing with oil putty in square, rectangle exc 0.5 Sqm in each pane complete all as specified and directed.
37S&F tubular/towel rail 20mm dia brass chromium plated 'D' type 60cm long between flange brass CP fixed with and incl chromium plated brass screws and wooden plastic cleats complete all as specified and directed.
38S&F CP fancy type Pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixe complete all as specified and directed.
39S & F ,CP toilet paper holder with flat recessed type stainless steel fixed to walls with chromium plated brass screws completed all as specified and directed
40S&F 150 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
41S&F Extruded aluminium alloy handle 150 mm long fabricated type anodised complete all as specified and directed.
42M&L powder coated aluminium window / ventilator shutters, sliding type with styles, rails, sash bar, 3 tier sliding frame etc. all are made from powder coated aluminium section weighting not less than 0.55 kg/m including necessary jointing cleats, glazing clips, rubber packing, aluminium snap beadings, screws, aluminium handles, locking arrangement etc complete all as specified and directed.
43S&F half stall urinal pot of size 355x340x535mm fixed with bracket including necessary fittings complete all as specified and directed.
44M&L PCC 1:2:4 type B-0, (using 12.5mm graded aggregate) 25 mm as in sub base in floors finished even complete all as specified and directed.
45M&L PCC 1:4:8 type D-2, (using 40mm graded aggregate) 75 mm as in sub base in floors finished even complete all as specified and directed.
46M&L Non-skid coloured ceramic tiles 7- 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.16 sqm, in floors etc. set and jointed in neat cement slurry over 15mm screed bed in CM 1:6 and pointed in white or coloured cement to match complete all as specified and directed.
47M&L Glazed colour ceramic tiles in vertical surface 450X 300X6-7mm thick set and jointed in neat cement slurry over 10mm backing coat in CM 1:4 and pointed in white or colour cement to match complete all as specified and directed.
48M&L for rendering 10 mm thick. on fair faces of brick or concrete surfaces in CM 1:6 finished even and fair without using extra cement as internal plaster on walls complete all as specified and directed.
49M&L for rendering 15 mm thick. on fair faces of brick or concrete surfaces in CM 1:4 in two layers and second layer mixed with integral water proofing compound and finished even and fair without using extra cement as external plaster on walls complete all as specified and directed.
50M&L for Preparation of new wall surfaces & applying two coats of oil emulsion distemper over a coat of chalk whitening complete all as specified and directed.
51M&L for preparing New surfaces of walls and applying two coats of exterior emulsion paint (weather coat) over a coat of alkali resistance primer complete all as specified and directed).
52M&L PCC 1:3:6 type C2 (using 20 mm graded stone, aggregate) as in concrete bed to drain pipes including packing under haunching against the sides of pipes after they are laid and tested for 150 mm dia SWG pipe complete all as specified and directed.
53M&L laying salt glazed stoneware drain pipe conforming to IS 651-1972 grade ‘A’ in trenches and jointed in cement mortar (1:1) for 150 mm internal diameter of pipes complete all as specified and directed.
54M&L Cutting into existing manholes for connecting new drains, making good to 150mm pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed.
55M&L pre-cast reinforced cement concrete 1:2:4 type B1(using 20 mm graded crushed stone aggregate) as in cover slab of man holes, septic tank etc set in CM 1:4 including necessary forms, moulds etc complete all as specified and directed.
56S&F vitreous china wash down water closet pan (pedestal pattern) white including connection to drain (or outgoing pipe) and to flush pipe, antishonage pipe and Plastic water closet seat, black, closed pattern with flat bottom, and cover and steel chromium plated or aluminised hinging device etc complete all as specified and directed.
57S&F 110mm bore PVC (SWR) Trap ‘S’/'P' complete all as specified and directed.
58S&F PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action type with inlet ball valve and float, handle with & including bracket and PVC flush pipe 32 mm bore complete all as specified and directed.
59S&F 1000 litres capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
60S&F PVC(SWR)floor trap 75 mm ,plain with grating setting and jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
61S&F110 mm PVC (SWR) pipe, single socketed, in any length, with rubber rings laid in trenches or floor complete all as specified and directed.
62S&F PVC (SWR) bend 110mm bore complete all as specified and directed.
63S&F 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
64S&F 75 mm PVC (SWR) pipe, single socketed, in any length, with rubber rings fixed to walls complete all as specified and directed.
65S&F PVC (SWR) vent cowl 75mm dia complete all as specified and directed.
66S&F PVC (SWR) Bend radius any radius 75mm bore complete all as specified and directed.
67S&F PVC (SWR) junction single, (Single T) equal or unequal 75mm bore complete all as specified and directed.
68S&F vitreous china pedestal wash hand basin size 550x400 mm including one number chromium plated waste fittings 32 mm dia with long screw shanks and fly nuts ,flange end beded in red lead cement and other end fixed ,with and including 32 mm di PVC waste pipe with connector ,including cutting for and pinning in ends of brackets complete all as specified and directed.
69Supplying and laying of 25mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
70Supplying and laying of 20mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
71S&F in repair, 600 mm x 450 mm size beveled edge mirror of selected quality glass, 5.50 mm thick, mounted on 6mm thick AC pain building board or commercial plywood and fixed to wall with wooden plugs and chromium plated brass screws & cup washers complete all as specified and directed.
72S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to 20mm bore steel tube complete all as specified and directed.
73S&F in repair, CP soap dish fixed to wall with screw complete all as specified and directed.
74Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 250 litters but not exceeding 1000 litres complete all as specified and directed.
75Demolition of brickwork built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
76Demolition of unreinforced cement concrete in ground flooring and paving not exc. 15 cm thickness below or above ground level complete all as specified and directed.
77Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition of any description in any position not specifically provided complete all as specified and directed.
78Surface dressing n.exc (not exceeding) 15 cm deep and getting out soft/loose soil complete all as specified and directed.
79Excavation in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and not exc. 1.5 m. in depth and getting out in soft/loose soil complete all as specified and directed.
80Returning filling in , including spreading, levelling, watering & well ramming in layers not exc 25 cm complete all as specified and directed.
81Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
82Taking down 15mm bore steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed.
83Taking down 20mm bore steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed.
84Taking down chowkat or frame with shutter (without taking off shutter from frames) not exc. 1.5 sqm each, including cutting holes for removing the hold fast etc (Distrubed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same) complete all as specified and directed.
85M&L Cement concrete 1:4:8 (Type D2) in foundations, filling and mass concrete complete all as specified and directed.
86M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including bituminium gap filling necessary form work, complete all as specified and directed.
87M&L for RCC 1:2:4 type B-1 (Nominal mix) (using 20 mm graded aggregate) as in foundation, footing, foundation beam, plinth beam, base for columns, etc. complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately.
88M&L for RCC 1:2:4 type B-1 (Nominal mix) (using 20 mm graded aggregate)as in columns, etc. complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately.
89M&L for providing reinforced cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
90M&L for RCC 1:2:4 type B-1 (Nominal mix) (using 20 mm graded aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately.
91M&L TMT bar 10 mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including steel wire (annealed) not less than 0.90 mm dia as reinforcement complete all as specified and directed.
92All as per ser Item No 91 above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
93Use and waste form work to side of concrete foundation, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beam as rough finish and similar wrok vertical or to batter complete all as specified and directed.
94Use and waste of formwork to sides of and soffits of floor or roof beams beam haunchings girders, bressummers ,lintels cantilevers, shelves including supports, overhangs, etc also splays between floors and beams complete all as specified and directed.
95Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions as in rough finished surfaces of concrete complete all as specified and directed.
96Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide as in rough finished surfaces of concrete complete all as specified and directed.
97Use and waste of formwork to soffit of suspended slabs such as roof slabs, floorslabs, landings and similar work not exceeding 200 mm thick rough finished in flat surface complete all as specified and directed.
98Supply only Integral water proofing compound (WPC), conforming to IS and as approved, complete all as specified and directed.
99M&L for brick work sub class 'B' bricks, straight or curved on plan, exc 6m mean radius built in CM 1:6 complete all as specified and directed.
100M&L for providing 3 mm thick wall care putty on ceiling before applying acrylic distemper /exterior emulsion paint and making the surface uniform complete all as specified and directed.
101M&L rendering 10mm thick in cement mortar (1:3) as in ceilings finished even and fair (without using extra cement) complete all as specified and directed.
102M&L for rendering 15 mm thick. on fair faces of brick or concrete surfaces in CM 1:4 in two layers and second layer mixed with integral water proofing compound and finished even and fair without using extra cement as external plaster on walls complete all as specified and directed.
103M&L for preparing New surfaces of walls and applying two coats of exterior emulsion paint (weather coat) over a coat of alkali resistance primer complete all as specified and as directed) complete all as specified and directed.
104M&L PCC 1:2:4 type B-0, (using 12.5mm graded aggregate) 25 mm thick as in sub base in floors finished even complete all as specified and directed.
105M&L PCC 1:4:8 type D-2, (using 40mm graded aggregate) 75 mm as in sub base in floors finished even complete all as specified and directed.
106M&L Non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry over 15mm screed bed in CM 1:6 and pointed in white or coloured cement to match complete all as specified and directed.
107M&L Glazed colour ceramic tiles in vertical surface 450X 300X 6-7mm thick set and jointed in neat cement slurry over 10mm backing coat in CM 1:4 and pointed in white or colour cement to match complete all as specified and directed.
108M&L 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking plat forms and like in cement mortar (1:4) including pointing in white cement (1:2) us ing marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
109M&L Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
110M&L factory made solid PVC door Frame of size 50 mmx47 mm made out of 5mm thick wood grain printed PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with printed sheet reinforced MS square tube supplying & fixing in opening as per specification & drawing complete all as specified and directed.
111S&F 100 mm Butt hinge, extruded brass, with steel hinge pin, bright polished and fixed, type B-11 complete all as specified and directed.
112S&F 200mm long aluminium anodised tower bolt of extruded section and fixed, complete all as specified and directed.
113S&F Extruded aluminium alloy handle 150 mm long fabricated type anodised complete all as specified and directed.
114M&L powder coated aluminium window / ventilator shutters, sliding type with styles, rails, sash bar, 3 tier sliding frame etc. all are made from powder coated aluminium section weighting not less than 0.55 kg/m including necessary jointing cleats, glazing clips, rubber packing, aluminium snap beadings, screws, aluminium handles, locking arrangement etc complete all as specified and directed.
115M&L figured glass pin head 4.00 mm thick ordinary quality and glazing with oil putty in square, rectangle exc 0.5 Sqm in each pane complete all as specified and directed.
116S&F chromium plated hand shower health faucet ABB body with 8 mm dia. 1.00 m long CP flexible pipe 15 mm bore with wall hook complete all as specified and directed.
117S&F connection pipe, chromium plated, 450mm long witth PTMT nuts at both ends 15 mm dia, suitable for geyser complete all as specified and directed.
118S&F for CP 15mm bore angular stop cock with wall flange fixed with screws complete all as specified and directed.
119S&F in repair, 15 mm bore chromium plated fancy type long body bib tap with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
120S & F corner shelf of fixed with chromium plated brass screws and wooden / plastic cleates (Minium weight 300 gms) complete all as specified and directed.
121S&F tubular/towel rail 20mm dia brass chromium plated 'D' type 60cm long between flange brass CP fixed with and incl chromium plated brass screws and wooden plastic cleats complete all as specified and directed.
122S&F in repair 15mm dia cast copper alloy chromium plated fancy type wall mixer with with crutch and adjustable wall hook copper alloy with capstan heads C.P screwed down high pressure with or without without lettered hot or cold with screwed shanks and fly nuts screwed for iron and fixed complete all as specified and directed.
123S & F ,CP toilet paper holder with flat recessed type stainless steel fixed to walls with chromium plated brass screws complete all as specified and directed.
124S&F in repair 110mm bore PVC (SWR) Trap ‘S’/'P' complete all as specified and directed.
125S&F in repair vitreous china Rimless Single Piece WC (White) With PP Soft Close Slim Seat Cover, Hinges, Dual Flush Cistern Fittings, Fixing Accessories And Accessories Set, Size: 370x690x750 mm, S Trap- 300 mm complete all as specified and directed.
126S&F for rotational moulded polyethylene water storage tanks 1000 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as per SSR Part I complete all as specified and directed.
127S&F in repair PVC(SWR)floor trap 75 mm ,plain with grating setting and jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
128S&F in repair 110 mm PVC (SWR) pipe, single socketed, in any length, with rubber rings laid in trenches or floor complete all as specified and directed.
129S&F in repair PVC (SWR) bend 110mm bore complete all as specified and directed.
130S&F in repair 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
131S&F in repair 75 mm PVC (SWR) pipe, single socketed, in any length, with rubber rings fixed to walls complete all as specified and directed.
132S&F in repair PVC (SWR) vent cowl 75 mm dia complete all as specified and directed.
133S&F in repair PVC (SWR) Bend radius any radius 75mm bore complete all as specified and directed.
134S&F in repair vitreous china Counter top Wash hand basin (White) of size (570x420x195 mm) mm complete all as specified and directed.
135Supplying and laying of 15mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
136Supplying and laying of 20mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
137S&F in repair 5 mm thick glass mirror (600X800) mm with Decorative high bright LED strip Touch switch for LED light Double coat for protection and longevity Silver plating on the back for better reflection complete all as specified and directed.
138S&F Gun-metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed to 20mm bore steel tube complete all as specified and directed.
139S&F in repair, CP soap dish fixed to wall with screw complete all as specified and directed.
140M&L for Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLS type drawn through and including PVC concealed conduit (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.6mm thick, with 3mm thick plastic laminated sheet cover of adequate size for one light or one fan point controlled by one switch incl 1.5 Sqmm (nominal area) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of luminaires/ fan at other end complete as per site requirement and complete all as specified and directed for the following:- (a) One light point or one fan point controlled by one switch with cables 1.5 sq. mm size Note:- Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc.
141All as per ser item No. 140 above, but for One 5 Amp 5 pin socket outlet point on independent board complete all as specified and directed.
142All as per ser item No. 140 here in before, but with 4.0 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 5 pin socket outlet point including PVC cable 4 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to common earth & earth terminals including boards for mounting purposes complete all as specified and directed.
143S&F in replacement switch piano flush button 5 Amp single pole one way 230 volts white finish complete all as specified and directed.
144S&F in replacement switch socket combination flush type 5 pin 5 Amp multipurpose 230 volts single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish complete all as specified and directed.
145S&F in replacement of switch socket combination multipurpose flush type 2 in 1 type (3 and 5 pin) 5/15 Amps, 230V, AC complete all as specified and directed.
146S&F in replacement ceiling rose surface PVC 50mm dia 3 terminal including PVC mounting block white/ivory finish complete all as specified and directed.
147S&F LED Mirror light fitting 1x 5W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
148S&F LED light fitting 1x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
149S&F distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 4 ways complete all as specified and directed.
150S&F of MCB SP 6-32 Amps/ 40 Amps, 230 Volts, 50 Hz with 10 KA ,'C' series complete all as specified and directed.
151Supply and Fixing of MCB SPN/DP upto 32 Amps, 230 Volts, 50 Hz with 10 KA ,'C' series complete all as specified and directed.
152S&F in replacement exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete as per site requirement and complete all as specified and directed..
153M& L of earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5mtr below normal ground level connected to galvanized lead wire of 4.00mm dia by means of bolts nuts,check nuts and washers of galvanized iron or steel incl PCC pit of 1:2:4 type B-1, cover reinforced with XPM weight not less than 4kg/ Sqm and 6mm dia handle , earth pit angle iron frame of size 25mm x 25mm excavation and earth work in any type of soil charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire mesh and medium grade GI protection pipe of 15mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical plate No. 3 of MES Sch 2009 (Part I) connected to main switch board complete all as specified and directed and testing on completion.
154Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed.
155Returning, filling in trenches, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer in soft/loose soil complete all as specified and directed.
156Removing excavated material/surplus soil and depositing where directed at a distance not exceeding 50mtr and depositing at a level not exceeding 1.5 mtr from starting point complete all as specified and directed.
157Supply lay/spread in trenches, river sand, clean, including spreading, levelling, punning as in cushioning of cables complete all as specified and directed. Note :- Punned depth will be measured and paid.
158Supply, lay in trenches fly ash bricks, old size for cable protection complete all as specified and directed. Note:- Bricks shall be laid in such a way that its length is perpendicular to the length of cable.
159Supply, laying, connecting and testing LT UG cable FRLS XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade sheathed, multi stranded of 10 sqmm 2 core cross sectional area complete all as specified and directed :- Note :-(i) Lugs and glands are deemed to be included in the rate quoted for laying of cable and to be used properly wherever required while connecting cables to the panel board. (ii) Earth work such as excavation, refilling, etc. shall be measured separately under relevant items.
160Taking down carefully copper/aluminium point wiring complete (light, fan, plug point & power complete alongwith fittings (switches, ceiling roses, tube light fittings, bulk head fitting regulator, sockets , removing materials to store and offering credit & making good of disturb surfaces of wall/floors etc as specified & directed.
161M&L for Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLS type drawn through and including PVC concealed conduit (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.6mm thick, with 3mm thick plastic laminated sheet cover of adequate size for one light or one fan point controlled by one switch incl 1.5 Sqmm (nominal area) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of luminaires/ fan at other end complete all as specified & directed. for the following:- (a) One light point or one fan point controlled by one switch with cables 1.5 sq. mm size Note:- Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc.
162All as per ser item No. 161 here in before but for One 5 Amp 5 pin socket outlet point on independent board complete all as specified & directed.
163All as per ser item No. 161 here in before but with 4.0 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 5 pin socket outlet point including PVC cable 4 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to common earth & earth terminals including boards for mounting purposes complete all as specified & directed.
164S&F in replacement modular switch piano flush button 5 Amp single pole one way 230 volts white finish complete all as specified & directed.
165S&F in replacement modular switch socket combination 6 Amp multipurpose 230 volts single pole one way suitable for 3 pin/2pin 6 Amp plug top white ivory finish complete all as specified and directed.
166S&F in replacement modular switch socket combination 6 Amp multipurpose 230 volts single pole one way suitable for 16 Amp plug top white ivory finish complete all as specified and directed.
167S&F in replacement ceiling rose surface PVC 50mm dia 3 terminals including PVC mounting block white/ivory finish.
168S&F LED Mirror light fitting 1x 5W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
169S&F LED light fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
170M&L of submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 6 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits including 6 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note:- (i) Two runs of cables and one run of continuous earting cable drawn in conduit/ casing and caping will be measured as one lengt of sub main. (ii) PVC conduit / casing caping and its accessories is deem to be included in this item rates.(iii) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc.
171S&F distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 8 ways complete all as specified and directed.
172S&F sheet metal encloures with plug socket single pole and neutral with two pin and earth plug and with one MCB f 20 Amps (SP) complete all as specified and directed.
173S&F in replacement of MCB SP 6-32 Amps/ 40 Amps, 230 Volts, 50 Hz with 10 KA ,'C' series complete all as specified & directed.
174S&F in replacement of MCB SPN/DP upto 32 Amps, 230 Volts, 50 Hz with 10 KA ,'C' series complete all as specified & directed.
175S&F in replacement exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete as per site requirement and complete all as specified & directed.
176S&F electric water heater, storage type steel body with MS inner tank and heating element upto 2 kw capacity 25 ltrs BEE 5 star rated complete with accessories such as safety valve, thermostate, NRV, connection pipes etc complete all as specified and directed.
177S&F in replacement of 8 Watt Bamboo LED Bollard decorative light Glaze fitting with low glare diffuser including taking down of old unserviceable light fitting and necessary PCC work 1:2:4 of adequate size for fixing of bollard fitting as per site requirement, testing & commissioning and complete all as specified and directed.
178Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core complete all as specified and directed.
179Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed.
180Returning, filling in trenches, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer in soft/loose soil complete all as specified and directed.
181Removing excavated material/surplus soil and depositing where directed at a distance not exceeding 50mtr and depositing at a level not exceeding 1.5 mtr from starting point complete all as specified and directed.
182M&L for HDPE Double wall corrugated duct pipe of size 40mm OD and 32mm ID for cable protection laid in trenches complete all as specified and directed.
183M&L Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FR type drawn through and including PVC casing caping/PVC conduit (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc fixed on surface of walls, columns/beams alongiwth 1.5 Sqmm (nominal area)copper conductor cable (multistranded) PVC insulated and unsheathed as earth wire connected to common earth dolly at one end and metallic bodies of luminaire/fan at other end including PVC folding boards with sunmica top for mounting switches, sockets, fan Regulators, accessories etc as per site requirement and complete all as specified and directed for the following :- (a) One light point or one fan point controlled by one switch with cable 1.5 Sqmm size
184All as per ser item No 183 above but with 2.5 PVC copper standed cable FRLS type for one 15 Amp 6 pin socket outlet point including PVC cable 2.5 Sqmm FRLS type copper standed conductor as earth wire as specified and connected to common earth & earth terminals including boards for mounting purpose complete all as specified and directed.
185S&F in replacement switch piano flush button 5 Amp single pole one way 230 volts white finish complete all as specified and directed.
186S&F of switch socket combination multipurpose flush type 2 in 1 type (3 and 3 Pin) 5/15 Amps, 230V, AC complete all as specified and directed.
187Supply and installation of air cooled split unit air conditioner electric driven, single phase of capacity of 2 TR with 5 star rating along with connected accessories, complete all as specified and directed.
188M&L PVC Sheathed cable wiring with copper conductor cables in PVC casing and caping, one 3 pin socket outlet, 15 amps |independent with cables 4sgmm size complete all as specified and directed.
189S&F Single pole and neutral enclosure with a two pin earth olug and socket complete with one single pole MC8 complete all as specified and directed.
190M&L Wiring for submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor sing Cable in surface /recessed as required 2x6.0 sqmm+ 1x6.0 sqmm earth wire in Steel Conduit complete all as specified and directed.
191S&F Single pole and neutral 4 way with 200 Amps rated bus bar complete all as specified and directed.
192Supply and installation of air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 TR with 5 star rating along with connected accessories, complete all as specified and directed.
193S&F amp rating 240V 10KA C Curve miniature circuit breaker (MCB) of following pole sand Current carrying capacity in the MCR DB complete with connection testing and commissioning SP 20 Amps complete all as specified and directed.
194S&F 415V 10 KA 'C' curve miniature circuit breaker (MCB) of following Poles and current carrying capacity in tvhey DB complete with connection testing and commissioning TPN 40 to 100 AM complete all as specified and directed.
195S&F Voltage Stabilizer 5 kva 5 star with rated capacity 130-300 Volt operation range in auto mode with high and low voltage auto cut off complete all as specified and directed.
196Excavation in trenches in soft / loose soil n.exc 1.5 mtr wide n.exc 1.5 mtr deep getting out soil complete all as specified and directed.
197Returning filling in including spreading levelling well ramming in layers n.exc 25 cm thick in a layers complete all as specified and directed.
198Removing excavated material (Soil) n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
199M&L XLPE insulated armoured heavy electric cable with aluminium conductor ,1100 volts grade ,cross sectional area 4 core 25 sqmm complete all as specified and directed.
200M&L HDPE double wall corrugated duct pipe of size 40mm outer dia for protection of cable laid in trench complete all as specified and directed.
201S&F 415V A C curve miniature circuit breaker MCB) of 100 AMP complete all as specified and directed.
202S&F Triple Pole and neutral 4 way DB 415 volt double door complete all as specified and directed.
203NOTES :-1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56890524
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30.89 Lakhs
LAST DATE 28-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Ladies/Gents Toilets At Small Arms Ranges, Addn/Altn To Certain Toilet At Offrs Mess, Provn Of Garden Lights At Certain Locations, Provision Of Complete Re-Wiring Of 41 Dsc Guard Post For Stand By Light Supply And Provn Of Qty 04 Acs At Gdcc At Af Stn Bagdogra Under Ge (Af) Bagdogra
Basic Detail
Tender No 8702/E8
Bidding Type Tender
Location
City Darjeeling
State West Bengal
Key Dates
Publish Date 07 Aug 2026
Submission Date 28 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 30.89 Lakhs
Tender Fee 500
EMD 61780
Exemption Available
Document List
BOQ_877531.xls
faa714be-60c4-4eec-9e7b-144f6b23c435.html
Tenderdocuments8702.pdf
Tendernotice_1 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_877531.xls

html

faa714be-60c4-4eec-9e7b-144f6b23c435.html

pdf

Tenderdocuments8702.pdf

pdf

Tendernotice_1 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail