Health and Family Welfare Government Departments Closing in 8 days TDR #56890085

Tender For Supply Installation Testing and Commissioning of Cctv & Epbax System In 50 Bedded Satelite Hospital Parthviraj Nagar, Distt. Jaipur

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
11.40 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
8 days left
EMD
22800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Cctv & Epbax System In 50 Bedded Satelite Hospital Parthviraj Nagar, Distt. Jaipur

BOQ

Name of Work:- SITC of CCTV & EPBAX System in 50 Bedded Satelite Hospital Parthviraj Nagar, Distt. Jaipur
Sl. No. Item Description
1S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
225 mm
3Providing & Fixing of ISO certified company made virgin material PVC trunking system as per PWD specification for electrical Works, with double lock feature for cable management including finishing accessories like corners, tees, adjustable angles, junction etc. as required . The trunking system shall have adaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. OEM shall have submit NABL accrediated /CPET lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
432mm X 20mm
5Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
6Supply & Installation of IP-20 & IK-08 , UL Listed Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19\\" angles with wall mounting provision on wall. Accessories like: 1 No of 19\\" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19\\" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
715 U Rack with Width 600 mm & Depth 400 mm + 100 mm
8Supply, Installation, Testing & Commissioning of 1 KVA 1 Phase Input,with IGBT Based Rectifier True Online Double Conversion Robust design Wide input voltage range: 160~300VAC @ 100% load (linearly derating to 50% load @ 100VAC input). Generator Compatible with Wide Input voltage window Double Conversion Efficiency >91% & ECO mode efficiency up to 98% 100% load @ 0~40C operating temp. Active Input Power Factor Correction 0.99 O/P power factor 0.9 Inbuilt OVCD (Over Voltage Cut-off device) Fully conform coated PCBA adaptable to harsh environment Offer terminal blocker on 2K/3K rating to connect to big capacity equipment Digital Charger Technology provide 02-10 A charging current Easy understanding LCD for convenient installation setup with Minimum 60 minute battery back up (26AH x 3 Nos of SMF batteries branded and recommended by UPS OEM, battery stand and interlink FR PVC copper cable of appropriate size and lugs), with required cabling for incoming & outgoing connection. UPS should be NABL certified with CE, ROHS & BIS compliance. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
9Supply, Installation, Testing & Commissioning of 2 KVA 1 Phase Input,with GBT Based Rectifier True Online Double Conversion Robust design Wide input voltage range: 160~300VAC @ 100% load(linearly derating to 50% load @ 100VAC input). Generator Compatible with Wide Input voltage window Double Conversion Efficiency >91% & ECO mode efficiency up to 98% 100% load @ 0~40C operating temp. Active Input Power Factor Correction 0.99 O/P power factor 0.9 Inbuilt OVCD (Over Voltage Cut-off device) Fully conform coated PCBA adaptable to harsh environment Offer terminal blocker on 2K/3K rating to connect to big capacity equipment Digital Charger Technology provide 02-10 A charging current Easy understanding LCD for convenient installation setup with Minimum 60 minute battery back up (26AH x 6 Nos of SMF batteries branded and recommended by UPS OEM, battery stand and interlink FR PVC copper cable of appropriate size and lugs), with required cabling for incoming & outgoing connection. UPS should be NABL certified with CE, ROHS & BIS compliance. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
10Supply, Installation, testing and commissioning of BIS compliance Professional series Diagonal Screen size 43\\" LED with Resolution 3,840 x 2,160 (4K UHD) along with Static (Panel) Contrast Ratio (1300:1) or better with viewing angle of 178/178 degree with response time of 8ms along with HDMI In 2.0 - 2 nos., USB 2.0-2 nos., RS 232- 1 nos., RJ 45- 1Nos. with Built in Speaker(10W + 10W) , with high speed processor and android or other reputated operationg system along with 4 GB RAM along with all audio and video decoder, Stand-by / sleep / off mode power 0.5 watt, . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
11SITC of 8 port Giga PoE Switch with dual uplink : unmanaged PoE switch; 8X10/100/1000 mbps Base-T PoE; 2*10/100/1000 Base-T (Uplink) or 2*1000 Base-X (uplink); PoE Power Consumption per Port: ≤30W; power budget: minimum 96 W; PoE Protocols: IEEE802.3af, IEEE802.3at ; Switching Capacity: 20 Gbps or better; MAC Table Size 2K or better; Working Temperature: -5°C~55°C; Power supply: DC48~57V Certificate of compliance: CE/FCC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with P.W.D. Electrical B.S.R. 2022.
12SITC of IR IP Based 5 MP Dome camera : 1/2.8\\" Progressive CMOS, ICR, IR, 2560(H)x1920(V):25fps(P) , 2.8/3.6 mm lens (As per site requirement) H 264,H265/MJPEG, dual-stream, 120dB WDR or better, 3D DNR, BLC, IR: minimum 30 mtr, Provision for Support on-board storage up to 256 GB (SD card not included), intrusion detection, Line crossing detection, Motion detection, Dynamic analysis, Alarm should be trigger on (Tampering alarm, Network disconnect, IP address conflict, Storage exception), security feature such as (password protection, privacy mask, watermark, IP address filtering, anonymous access), Open standard to support ONVIF (PROFILE S, PROFILE G), Metal Housing, Vandal-proof housing IP 67, DC 12V & PoE, Complete with Junction box for cable management Oerating Conditions : 20 °C - 50 °C or better. Model should be : CE, BIS,/UL,FCC,ROHS compliance. The CCTV OEM should have CMMI Level 5 or above or equivalent setup certification. The CCTV OEM should have its office and service/ support center in RajasthanAll as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
13SITC of IR IP based 5 MP Bullet Camera 5 MP , Video Resolution: 2592(H)x1944(V) Pixels , 1 to @25 fps; Image Sensor: 1/2.8-inch CMOS; Built in Infra-Red: 40 to 50 mtr; High Dynamic Range- 120 dB WDR; Lense- 2.8/3.6 mm, ;H264,H265/MJPEG , provision for Support on-board storage up to 256 GB (SD card not included) , intrusion detection, Line crossing detection, Motion detection, Dynamic analysis, Alarm should be trigger on (Tampering alarm, Network disconnect, IP address conflict, Storage exception), security feature such as (password protection, privacy mask, watermark, IP address filtering, anonymous access), Open standard to support ONVIF (PROFILE S, PROFILE G), Metal Housing, Vandal-proof housing IP 67, DC 12V & PoE, Complete with Junction box for cable management Oerating Conditions : -30°C to + 70 °C or better. Onvif Profile S,G,Confirmant;Model should be : CE, BIS,/UL,FCC,ROHS complianceThe CCTV OEM should have CMMI Level 5 or above or equivalent setup certification. The CCTV OEM should have its office and service/ support center in RajasthanAll as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
14Supply, Installation, Testing & Commissioning of 32 ch NVR Pre-licenced, NVR supports upto 40 TB HDD Support, 32 ch IP inputs; ; Support ANR technology; 320mbps incoming bandwidth, supports up to 12MP full channel recording; support H.265 compression; 16ch syncronised playback @1080p; support 3rd party cameras ONVIF type; 4K output; minimum 04 SATA HDD Slots; each slot should suppport upto 10TB HDD; Dual gigabit self adaptive Ethernet interface; serial interface; USB interface; (all cameras and Storage-NVR should be of same make for the smooth functioning of the system).complete with mounting accessories & junction box (to be provided by OEM) for cable management. Model should be : Certificates of Compliance: UL, CE/FCC, BIS. The CCTV OEM should have CMMI Level 5 or above or equivalent setup certification. The CCTV OEM should have its office and service/ support center in RajasthanAll as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
15Supply, Installation, Testing & Commissioning of of 3.5\\" 6 TB SATA ,USB 3.0 Surveillance Hard Disk .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
16Supply Installation Testing and Comissioning of Digital EPABX System with 06 PNT incoming lines, 02 Digital Ports, 80 Extension Analog Extension lines Expandable upto 160 Ports . It should have built-in participant’s conference. i.e. 3 party conference & iNBUILD MUSIC ON HOLD should Support ISDN / PRI Line for 30 channel ,System should have Digital Phone with 24 Keys and 12 Keys for Operator for monitoring call at Receptions Systems should have .
17Supply Installation Testing and Comissioning of Digital Phone with following Specification: Handsfree and open listening, 24 Programable Keys, , WithDisplay, Last number redial.
18Supply Installtion Testing and Comissioning of Analog Phone with Handsfree and open listening, 50 entries for CLIP, Last number redial.
19Supply Installtion Testing and Comissioning of 200 Pair MDF with Crone type Modules with following specifications: Thickness of MDF Box: 20 Gauge (0.812 MM) with powder coting
20Supply Installtion Testing and Comissioning of 1+1 Analog Phone with Handsfree and open listening, 50 entries for CLIP, Last number redial. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56890085
AUTHORITY Government Departments
TENDER VALUE 11.40 Lakhs
LAST DATE 19-08-2026
Authority
Authority Name Medical And Health Services
Work Description Tender for Supply Installation Testing and Commissioning of Cctv & Epbax System In 50 Bedded Satelite Hospital Parthviraj Nagar, Distt. Jaipur
Basic Detail
Tender No NIT No.12/2026-27EEM and HDiv 2 Jaipur/
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 07 Aug 2026
Submission Date 19 Aug 2026
Open Date 20 Aug 2026
Finance
Tender Value 11.40 Lakhs
Tender Fee 500
EMD 22800
Exemption Not Available
Document List
a2025d3c-0ece-443e-85d2-67bd74653546.html
Annexure-A-BSR-2022.pdf
BOQ_1036730.xls
Special-TandC-for-Electri_1.pdf
T-and-C-for-Electrical-wo_2.pdf
Tendernotice_1 (31).pdf
Tendernotice_2 (3).pdf
Tendernotice_3 (2).pdf
Tendernotice_4.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Aug 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

a2025d3c-0ece-443e-85d2-67bd74653546.html

pdf

Annexure-A-BSR-2022.pdf

xls

BOQ_1036730.xls

pdf

Special-TandC-for-Electri_1.pdf

pdf

T-and-C-for-Electrical-wo_2.pdf

pdf

Tendernotice_1 (31).pdf

pdf

Tendernotice_2 (3).pdf

pdf

Tendernotice_3 (2).pdf

pdf

Tendernotice_4.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders