Housing Urban and Rular Development Government Departments Closing in 6 days TDR #56887479

Tender For maintenance and repair To Shahad Water Works And Udds Dombivali...Providing Annual Maintenance For Lt Control Panels And Starters At Shahad Water Works And Udds Dombivali.

Issued by Government Departments · Thane, Maharashtra
Tender Value
38.52 Lakhs
Estimated cost
Bid Submission
22 Aug 2026
6 days left
EMD
38600
Bank guarantee accepted
Document Fee
10030
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thane → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for maintenance and repair To Shahad Water Works And Udds Dombivali...Providing Annual Maintenance For Lt Control Panels And Starters At Shahad Water Works And Udds Dombivali.

BOQ

Name of Work:- M&R to Shahad Water Works and UDDS Dombivali...Providing annual maintenance for LT control panels and starters at Shahad Water Works and UDDS Dombivali.
Sl. No. Item Description
1Sub Estimate 1Providing annual maintenance for LT control panels and starters at Shahad Water Works.
21. Maintenance of 15HP/25HP/60HP/75HP/200HP FCMA Soft Starter/Star Delta starter for each pump set with test and trial labour charges at Phase-I & Phase-II UDDS Dombiali, Raw Water Works and Pure Water Works, Shahad.
32. Labour rate for monthly maintenance contract including inspection, checking & servicing of LT motor control panels with MCCB, power contactor for each pump set with appropriate settings / testing of relay timer/contacts, cleaning of all spares/equipments with cleaning spray, etc. complete and giving testing and trials for period of one years.
43. AMC of Static VAR Generator (IPFC) panel along with the manufacturer consisting of all the essential consumables like cleaning spray, duster and hardware required and carrying out necessary corrective maintenance. Job includes 1) Half yearly servicing 2) Attending repairing works within 24 hours 3) Sending standby manpower for VIP movement.
54. Providing Power Contactor 3 pole 400A MNX type AC3 Duty 240 V coil AC, 2 NO + 2 NC.
65. Providing Power Contactor 3 pole 300A MNX type AC3 Duty 240 V coil AC, 2 NO + 2 NC.
76. Providing Power Contactor 3 pole 250A MNX type AC3 Duty 240 V coil AC, 2 NO + 2 NC.
87. Providing Power Contactor 3 pole 140A MNX type AC3 Duty 240 V coil AC, 2 NO + 2 NC.
98. Providing Power Contactor 3 pole 70A MNX type AC3 Duty 240 V coil AC, 2 NO + 2 NC.
109. Providing Auxilary MXO-Contactor 22E Duty 240V coil AC 2 NO + 2 NC
1110. Providing Motor Protection relay MPR D2, Range:2-5.5A, 230V AC, CTR-400/5A, Setting-3.12A.
1211. Providing overload relay for motor starter Range6-10 Sec, Relay Range 20-33A.
1312. Providing MN12 (CT operated) Thermal overload relay, Relay Range: 180 – 300A.
1413. Providing Electronic timer ST 100, on Relay, Range 0.3 Sec-30 min, 240V AC/DC, Selected Range- 3 Min, Setting-30 sec.
1514. Providing Current Sensor (S2CTS 1/5) (up to 3.00 H.P.) (5 Amp.)
1615. Providing Add on Block D range contactor Rating 45A-80A, TA1-DN-22 2N0 + 2 NC 240 V Coil AC
1716. Providing Push Button Illuminated Actuator, Flush (with BA9S Filament Bulb 130V) 220V AC with series resistor.
1817. Supplying, erecting, testing & commissioning LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
1918. FCMA ELTEC SOFT STARTER Model SS1-150-OE-L1 50KW/ 200 HP / SS -415- 187KW/ 250HP (similar to existing design).
2019. Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-MCCB
2120. Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB
2221. Providing & erecting 3 Pole MCCB, 415V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no lineload bias in provided enclosure/panel as per specification no. SW-MCCB
2322. Supplying, erecting & marking TP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
2423. Supplying, erecting & marking SP MCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
2524. Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
2625. Supplying and erecting static energy meter with 240V 50 Hz. AC supply 10 to 60 A, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of energy & MD in kW & kVA) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weatherproof PVC wires duly tested by electric supply company.
2726. Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
2827. Providing 315A TPN Switch Fuse Unit (CSSDF315B3N)
2928. Providing 160A TPN Switch Fuse Unit (CSSDF160B3N)
3029. Providing 125 A TPN Switch Fuse Unit (CSSDF125B3N)
3130. Providing 100A TPN Switch Fuse Unit (CSSDF100B3N)
3231. Providing 63 A TPN Switch Fuse Unit (CSSDF63B3N)
3332. Providing 32 A TPN Switch Fuse Unit (CSSDF32B3N)
3433. Providing HRC Fuse Link (DIN Type) 200 A (CSDFL1)
3534. Providing HRC Fuse Link (DIN Type) 100 A (CSDFL00)
3635. Providing HRC Fuse Link (DIN Type) 125 A (CSDFL00)
3736. Providing HRC Fuse Link (DIN Type) 32 to 63 A(CDFL00 & CSDFL00)
3837. Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
3938. Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box/panel and duly connecting with necessary PVC wire leads and lugs.
40Sub Estimate 2Providing annual maintenance for LT control panels and starters at UDDS Dombivali.1. Providing & erecting 4 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB (Note:- 1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
412. Providing & erecting 3 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB
423. Supplying, erecting & marking TP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
434. Supplying, erecting & marking TP MCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
445. Supplying, erecting & marking SP MCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
456. Supplying, erecting & marking FP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
467. Providing Power Contactor 3 pole 205A, AC3 Duty 240 V coil AC, 1 NO + 1 NC.
478. Providing Power Contactor 3 pole 185A, AC3 Duty 240 V coil AC, 2 NO + 2 NC (LC1FDP185AE)
489. Providing Power Contactor 3 pole 80A, AC3 Duty 240 V coil AC, 1 NO + 1 NC (TC1-D8011)
4910. Providing Power Contactor 3 pole 32A MNX type AC3 Duty 240 V coil AC, 2 NO + 2 NC.
5011. Providing Power Contactor 3 pole 25A MNX type AC3 Duty 240 V coil AC, 2 NO + 2 NC.
5112. Providing overload relay for motor starter Range 6-10 Sec, Relay Range 65-105A (LR1F105)
5213. Supplying and replacing thermal overload relay for motor starter 10 HP to 17.5 HP.
5314. Providing Motor Protection relay MPR D2, Range:2-5.5A, 230V AC, CTR-200/5A, Setting-3.12A.
5415. Supplying, erecting, testing & commisioning LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
5516. Supplying & replacing electronic timer above 30 HP motor starter.
5617. Providing timer 800SD-2-230, on Relay, Range 30 to 60 Sec, Change over 50/100ms, 2 C/O, 230V AC,
5718. Supplying, installing, testing and commissioning air circuit breaker manual fixed type, non-drawout type, 650V, 630A, rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection), 50 kA (Ics=Icu=Icw for 1s), with standard accessories with ready to close, individual fault trip, alarm and trip indications, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-ACB
5819. Providing 200A, 4P Switch Fuse Unit ( CSSDF200B4FN)
5920. Providing 100A, 4P Switch Fuse Unit (CSSDF100B4FN)
6021. Providing 63 A TPN Switch Fuse Unit (CSSDF63B3N)
6122. Providing 32 A TPN Switch Fuse Unit (CSSDF32B3N)
6223. Providing HRC Fuse Link (DIN type) 200 A (CSDFL1)
6324. Providing HRC Fuse Link (DIN type) 100 A (CSDFL00)
6425. Providing HRC Fuse Link (DIN type) 32 to 63 A (CDFL00 & CSDFL00 )
6526. Push Button Illuminated Actuator, Flush (with BA9S Filament Bulb 130V) 220V AC with series resistor.
6627. Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
6728. Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
6829. Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box/panel and duly connecting with necessary PVC wire leads and lugs.
6930. Supplying, erecting, testing & commisioning 525 V 3 phase, 50 Hz., MPP type capacitor having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours kVAr bank of metalised polypropylene condensers (MPP) with the standard capacities of 2, 3, 5, 7, 10, 12.5 and 15 kVAr units of P.F. correction for operation on 3 phase 50 Hz. with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee.
7031. LT - MCCBs (SW-MCCB)31.1. Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-MCCB
7131.2. Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB
7231.3. Providing & erecting 3 Pole MCCB, 415V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56887479
AUTHORITY Government Departments
TENDER VALUE 38.52 Lakhs
LAST DATE 22-08-2026
Authority
Authority Name Maharashtra Industrial Development Corporation
Work Description Tender for maintenance and repair To Shahad Water Works And Udds Dombivali...Providing Annual Maintenance For Lt Control Panels And Starters At Shahad Water Works And Udds Dombivali.
Basic Detail
Tender No MIDC/E and M/AMB/38939/26/2026-27
Bidding Type Tender
Location
City Thane
State Maharashtra
Key Dates
Publish Date 07 Aug 2026
Submission Date 22 Aug 2026
Open Date 25 Aug 2026
Finance
Tender Value 38.52 Lakhs
Tender Fee 10030
EMD 38600
Exemption Not Available
Document List
bde6c635-4ab2-47b8-946c-ee8cdc151832.html
BOQ_2270937.xls
ItemSpecification.pdf
TenderDocument.pdf
Tendernotice_1 (31).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

bde6c635-4ab2-47b8-946c-ee8cdc151832.html

xls

BOQ_2270937.xls

pdf

ItemSpecification.pdf

pdf

TenderDocument.pdf

pdf

Tendernotice_1 (31).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders