Agriculture Government Departments Closing in 2 days TDR #56887033

Tender For Repairing Of Farm Office With Special Reference To Sanitary & Plumbing Works At Kotulpur Goat Farm, Kotulpur, Bankura-722141 Under Paschim Banga Go S Ad Bikash Sanstha , Kolkata-700106

Issued by Government Departments · 24 Paraganas North, West Bengal
Tender Value
46.50 Lakhs
Estimated cost
Bid Submission
25 Aug 2026
2 days left
EMD
93013
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairing Of Farm Office With Special Reference To Sanitary & Plumbing Works At Kotulpur Goat Farm, Kotulpur, Bankura-722141 Under Paschim Banga Go S Ad Bikash Sanstha , Kolkata-700106

BOQ

Name of Work:- Repairing of Farm office with special reference to Sanitary & Plumbing works at Kotulpur Goat Farm, Kotulpur, Bankura-722141 under Paschim Banga Go S ad Bikash Sanstha , Kolkata-700106
Sl. No. Item Description
1CIVIL AND ELECTRICAL REPAIRING Works
2Supplying, fitting and fixing in position FRP/GRP/COMPOSITE UV stabilizer Manhole Cover with high abrasion surface of 7mm top thickness with density of 2KG/m³ - approved make with rim of approved make (Heavy type)(ii) 20 MT load bearing capacity round manhole cover provided with two lifter hooks fitted with matching frame of sizeFrame: 600 mm (24\\")
3Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75m. In ground floor including roof(b) above 150 mm. thick
4Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.
5(A) Filling in foundation or plinth by silver sand inlayers not exceeding 150 mm as directed andconsolidating the same by thorough saturation withwater, ramming complete including the cost of supplyof sand. (payment to be made on measurement offinished quantity)(B) Do - by fine sand
6Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR value not more than 10% including necessary jointing materials for nonpressure underground Drainage, Sewerage & Cross drainage application
7(iv) 300mm internal dia.
8(ii) 200mm internal dia.
9Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping](iv) 12mm
10(B) Dressed wood work in post , plate , battens . etc. fitted & fixed complete (excluding the cost of bolts only, but including the cost of nails, screws etc.)(The quantum should be corrected upto three decimals)(ii) Sal : Local.
11Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge.The rate includes the cost of labour, adhesive and all incidental chargesthereof.In ground floorGlossy/Matt/Suede excluding surface texture or metallic lustre.(i) Thickness of laminate 1.5mm
12Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :(Two coats) ii) Luxury Quality
13Providing and fixing of false ceiling with powder coated exposed G.I. gridsuspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 15mm thick OW Acoustic Board (Mineral Fiber Acoustic Ceiling Tiles) of approved patern and size 595mm X 595mm with NRCvalue > 0.65 should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge.In ground floor.a) Acoustic False Ceiling (with 15mm thick OW Acoustic Board and E-Grid U1520)
1480 mm thick interlocking designer concrete paver block M-40 grade for medium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgradepreparation.) complete as per direction of Engineer-in-Charge. [Note: Subgrade CBR shouldnot be less than 5]Colour Decorative
15Supply of PVC insulated PVC sheathed/XLPE power cable of 1.1KV grade of AL. conductor cable as reqd. confirming to IS-7098 (part -1) 1988 with upto date amendment of the following sizes.
16(a) 4x95 sq mm armoured
17Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
184. Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] Avg Run 8 Mtr
19Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
20Supply & Fixing 240 V,6/16 A, 5 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wireetc.
21Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuitywire etc.
22Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
233 x 22/0.3 (1.5 sqmm)
242 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)(for 25 nos power plugs) for SPN DB to Power Plugs
252x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
26Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
27Supply and fixing 20 W LED tube light fittings(T 8 Crompton make) LT8-20-865-2 Incl supply and fixing Batten and Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length MAKE:CROMPTON/PHIIPS
28Supply and fixing 2'X2' LED CROMPTON MAKE 36 Watt LED surface light LCTLRN-36-FO-CDL
29S&F 230V,50 HZ AC (9'') Sweep Exhaust Fanm(Havells/EPC/ORIENT) after making hole in wall and making good damages & smooth cement finish etc .inclu. S&F leuvour Shutter/Cowl on wall with necessary bolts,nuts (6 mm x 62 mm long) and Providing necessary length of PVC insulated wire and making connection as per Gs.
30Supply and fixing 230 V,50 Hz AC (Crompton )Swing Gyro cabin fan .300-450 mm
31Charging of suitable Gas for split unit after repairing the bode and before assemble it to copper pipe
32Servicing of AC machine with jet pumping and cleaning both units
33Repairing of Out door Fan Motor
34Supply and fixing Running capacitor 45+5 MFD,440V AC,3% tolerence and new compressor terminal (APD P&D, APD MIS, server room & SE)
35supply and fixing new rotary type compressor which is sutitable fof 1.5 ton split AC machine (APD TRANING)
36Supply & replacement of existing aluminium coil with new copper coil and changing and providing necessary refrigeration piping matching with coil for 1.5 ton split AC machine
37supply and fixing of 2nos cpper pipe with insulation and rapping for 1.5 tr AC
38Taxes & Duties
39Add: G.S.T. @ 18% of Rs.39,02,218=24, ( sum of Sl. No. 1.01 to 1.36) i.e. Rs.7,02,399=28
40Add: Labour Cess @ 1% of Rs. 46,04,617=52 (sum of Sl. No. 1.01 to 2.01) i.e. Rs. 46,046=18 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56887033
AUTHORITY Government Departments
TENDER VALUE 46.50 Lakhs
LAST DATE 25-08-2026
Authority
Authority Name Animal Resources Development Department
Work Description Tender for Repairing Of Farm Office With Special Reference To Sanitary & Plumbing Works At Kotulpur Goat Farm, Kotulpur, Bankura-722141 Under Paschim Banga Go S Ad Bikash Sanstha , Kolkata-700106
Basic Detail
Tender No PBGSBS/ENGG-KGF/NIT-298/26-27
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 07 Aug 2026
Submission Date 25 Aug 2026
Open Date 27 Aug 2026
Finance
Tender Value 46.50 Lakhs
Tender Fee Ref. Documents
EMD 93013
Exemption Available
Document List
a4592beb-e620-4c26-8a01-d237ea3c9708.html
BOQ_2546111.xls
Tendernotice_1 (16).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Aug 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

a4592beb-e620-4c26-8a01-d237ea3c9708.html

xls

BOQ_2546111.xls

pdf

Tendernotice_1 (16).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders