Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #56885209

Tender For Repairs / Replacement Of Distribution Boards Mccb Mcb Submain Wiring Earthing Fire Fighting Flame Proof Lights And Connected Works In The Area Of Age E/M Yard-I Under Ge (East) Lucknow

Issued by Statutory Bodies & Commissions/Committees · Lucknow, Uttar Pradesh
Tender Value
40 Lakhs
Estimated cost
Bid Submission
28 Aug 2026
10 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairs / Replacement Of Distribution Boards Mccb Mcb Submain Wiring Earthing Fire Fighting Flame Proof Lights And Connected Works In The Area Of Age E/M Yard-I Under Ge (East) Lucknow

BOQ

Name of Work:- REPAIRS / REPLACEMENT OF DISTRIBUTION BOARDS MCCB MCB SUBMAIN WIRING EARTHING FIRE FIGHTING FLAME PROOF LIGHTS AND CONNECTED WORKS IN THE AREA OF AGE E/M YARD-I UNDER GE (EAST) LUCKNOW
Sl. No. Item Description
1Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete except fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete all as specified and directed.
2Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box with 3 mm thick Hylem laminated sheet top cover, steel screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed.
3All as per serial item No 02 here-in-before but one bell point controlled by one bell push, 06 Amp.
4All as per serial item No 02 here-in-before but one, two way light point controlled by two, two way switches, 06 Amp.
5All as per serial item No 02 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.
6All as per serial item No 02 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp.Note : One run of main power wire of size 1.5 sqmm nominal cross sectional area copper conductor will run from DB and quoted unit rate shall be deemed inclusive for this provision.
7All as per Serial Item No 02 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
8Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of modular type (Flush box paid under seprate items) etc and making good to the disturbed surfaces to match the existing complete all as specified and directed.
9Taking down OLD U/S Switch/socket/bell push/Ceiling rose any type and size complete all as specified and directed.
10S&F Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed
11S&F Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed
12S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed
13S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed
14Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) MCB, SPN, AC, 240 volt of 40 Amp, \\"C\\" curve, 10 KA breaking capacity - 08 Nos.
15Supply and fix in replacement of factory made Pantone 7541C shade powder coated distribution board SP & N 12 way fabricated of CRCA sheet with metal door (IP-43 protection) bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as a incomer and 10 SP MCBs as outgoing complete all as specified and directed conforming to IS: 8623 along end box for above complete all as specified and directed.
16Supply and fix in replacement of factory made Pantone 7541C shade powder coated distribution board SP & N 8 way fabricated of CRCA sheet with metal door (IP-43 protection) bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as a incomer and 6 SP MCBs as outgoing complete all as specified and directed conforming to IS: 8623 along end box for above DB.
17Supply and fix in replacement of AC Modular Box 20 Amp with steel enclosure suitable for Geyser & AC protection to human from eletric shock due to direct and Indirect current as well as provide protection from overload and short circuit fault complete with double pole MCB 20Amp after fixing making good surface with fine plastering, finishing and colouring with existing colour matching complete all as specified
18Supply and fix in replacement of TPN MCB 40 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity and terminal box suitable upto 35 sqmm cable complete all as specified and directed.
19Supply and fix in replacement of TPN MCB 63 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity complete all as specified and directed.
20Supply and fix in replacement of SP MCB 6 TO 32 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity and terminal box suitable upto 35 sqmm cable complete all as specified and directed.
21Supply and fix in replacement of MCB Single Pole & Neutral MCB 32 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity complete all as specified an directed.
22Supply and fixing in replacement of MCCB current rating 100 Amps with thermal magnetic release, 4 pole, 415 volts AC 16 KA Ics = 50% Icu as per IEC 60947-2 ruputuring capacity all as specified and directed.
23Supply and fixing in replacement of MCCB current rating 125 Amps with thermal magnetic release, 4 pole, 415 volts AC 25 KA Ics = 50% Icu as per IEC 60947-2ruputuring capacity all as specified and directed.
24Supply and fixing in replacement of MCCB current rating 160 Amps with thermal magnetic release, 4 pole, 415 volts AC 25 KA Ics = 50% Icu ruputuring capacity all as specified and directed.
25S&F in replacement of LED flood light 100 Watts with aluminium die cast IP 66 with symmetric light distribution energy saving, environmental friendly suitable for high lighting archtechural faced all as specified and directed.
26Supply fix in replacement LED building security light of 36W Led Street Light made up of pressure die cast aluminium housing with Polycarbonate cover and unique road optics for better uniformity. The luminaire shall be with higher ingress protection IP66 and impact resistance of IK07. Operating voltage range: 140-270V/50Hz, Lumen efficacy of LED >120Lm/W, CRI≥70, CCT-5700K, & SDCM<5. Powered by built-in potted LED driver gives constant light over wide voltage range. Shall have High Voltage cut-off@325V & safety from 440V (P2P) for 8 hours. Surge protection 4 kV, Power factor ≥0.95, THD ≤10 complete including 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fitting complete all as specified.
27Supply and fixing in replacement of Solar integral AIO streetlight with Aluminium housing, reliable & robust construction with IP65 & IK08 protection. The luminare Lithium /LifePo4 Battery capacity min [email protected] or 20w4.5v pv panel power CRI >=70, System Efficacy >165lm/W, & Minimum Lumen 4000 system wattage should not be more than 25W ± 2%, if wattages increases then the size of battery & panel shall also be increased in similar percentage to maintain equal autonomy of the system. Weight not more than 2.32 kg . The fixture should have in microwave motion sensor &sensor dealy time 18 seconds Life class of LED 50000hrs@ complete all as specified.
28Supply & fix in replacement LED building Flood light of 70 W Led Street Light made up of pressure die cast aluminium housing with Polycarbonate cover and unique road optics for better uniformity. The luminaire shall be with higher ingress protection IP66 and impact resistance of IK07. Operating voltage range: 140-270V/50Hz, Lumen efficacy of LED >120Lm/W, CRI≥70, CCT-5700K, & SDCM<5. Powered by built-in potted LED driver gives constant light over wide voltage range. Shall have High Voltage cut-off@325V & safety from 440V (P2P) for 8 hours. Surge protection 4 kV, Power factor ≥0.95, THD ≤10 complete including 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fitting complete all as specified.
29Supply & fix in replacement recess mounting LED light fitting 2'x2' luminaire architectural recessed luminaire with CRCA housing and Molded PC diffuser with an unique angular optics for making the illumination easy on eyes for light comfort in office areas with UGR<=19. The luminaire should have a color consistency SDCM< 5, CRI > 80 and choice of CCT: 5700K. Luminaire shall be designed to emit at least 3000 lumens and an efficacy of atleast 120Lm/W and maximum system wattage of 36 Watt, designed for ambient temp 45 deg C. The metallic electronic driver shall have a power factor >0.95, THD <10%, 4KV internal surge protection and the Ripple factor should be <5% to minimise the Flicker and Stroboscopic effect and The driver should be complied with Fixed output/DALI/POE version and Fixture should have an operating voltage range of 140-270VAC incl It should have over voltage protection @320V Cut-off with auto restart features. all as specified and directed by engineer in charge.
30Supply & fix in replacement recess mounting LED light fitting 1'x1' of 20/25 watt white powder coated CRCA housing with LEDs.,efficacy 100 lumen/watt,CRI>80 and pf>0.9,surge protection 2.5 KV, Seamless front frame with flat white high transmission acrylic cover and including cutting of 2x2 false ceiling sheet with cutting fitting size all as specified and directed by engineer in charge.
31Supply and fixing in replacement LED Bldg security light fitting LED 25 watt with SPD, PF not less or equal 0.9,epoxy coated cover sheet aluminium housing with heat resistant toughtened glass & IP 66 incl with bracket, clamps, nuts, bolts protection complete all as specified and directed and directed.
32Supply and fixing in replacement LED Bldg security light fitting LED 45 watt with SPD, PF not less or equal 0.9,epoxy coated cover sheet aluminium housing with heat resistant toughtened glass & IP 66 incl with bracket, clamps, nuts, bolts protection complete all as specified and directed and directed.
33Material and labour for replacement of sub main wiring with 10 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 10 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
34Material and labour for replacement of sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
35Material and labour for replacement of sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
36M & L for replacment of chemical earthing complete with Copper plate 600 x 600 x 3 mm buried directly in the ground vertically to depth not less than 2.25 Mtr below the ground level with the top edge of earth plate, depth not less than 1.5 Mtr below the ground level connected to copper strip of 20 mm x 3 mm size by means of bolts, nuts and washers , returning & filling the pit with excavated soil mixing with charcoal 250 KG ,crystal salt 200 KG , magnesium sulphate of 100 KG and vegitable soil all around the plate up to 350 mm above from top edge of plate and balance portion filling with excavated soil in layers not exceeding 25mm thick, 25 mm galvanized iron medium grade watering pipe up to top of plate ,50 mm bore galvanized iron light grade pipe for earth strip protection , including all excavation earth work in any type of soil ,PCC 1:3:6 type C1 for chamber of internal size 300 mm X300X300mm with 120 mm thick wall and 700 mmX700mmX150 mm thick ,bed concreate,RCC 1:2:4,type B1 for precast chamber cover 50 mm thick ,reinforced with welded steel wire fabric of XPM jali (weight not less than 4.00 Kg/sqm),funnel,with wire mesh, complete al as specified and directed. Note:- Up to 7.5 Mtr length of pipe of 40 mm dia and copper strip shall be deemed to be included in unit rate quoted by tenderer.
37M & L for replacment of earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including taking down and testing on completion complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56885209
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 28-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repairs / Replacement Of Distribution Boards Mccb Mcb Submain Wiring Earthing Fire Fighting Flame Proof Lights And Connected Works In The Area Of Age E/M Yard-I Under Ge (East) Lucknow
Basic Detail
Tender No GE/E/LKO/T-45 OF 2026-27
Bidding Type Tender
Location
City Lucknow
State Uttar Pradesh
Key Dates
Publish Date 07 Aug 2026
Submission Date 28 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
BOQ_877480.xls
d6b1d1b1-b7d9-453c-84a1-9843751a4bd7.html
Tendernotice_1 (6).pdf
TenderT45.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_877480.xls

html

d6b1d1b1-b7d9-453c-84a1-9843751a4bd7.html

pdf

Tendernotice_1 (6).pdf

pdf

TenderT45.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders