| Sl. No. | Item Description |
| 1 | Surface dressing n.exc 15 cm deep incl as in any type soil including taking out all sapling shrubs, brushwood, undergrowth, roots, and trees n. exc 30 cm girth all removing to a distance n.exc 100 m from starting point complete all as specified and directed by Engr-in-charge (The area is to be carried out in and around,structches viz transformes, HT and electric poles over head reservoirs, around power house and pump house and other E/M installation at Haldwani & Ranibagh. |
| 2 | Excavation in trenches nexc, 1.5m wide and not exc 1.5m deep and getting out complete in hard/dense soil for taking out and laying of CI/GI pipe and forming bottom surfaces of trenches to reqd slop/ gradient complete all as specified and directed. |
| 3 | Returning filling in, including spreading levelling watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed. |
| 4 | Removing excavated surplus materials (soils) to a distance nexc 50M and depositing where directed at a level nexc 1.5M above the starting point complete all as specified and directed. |
| 5 | Taking up or down steel tubing of any grade including all GI fitting laid in trenches or on open surface and connections for relaying or removal complete all as specified and directed for the following sizes :- (a) 50 mm dia |
| 6 | (b) 40 mm dia |
| 7 | (c) 32 mm dia |
| 8 | (d) 25 mm dia |
| 9 | (e) 20 mm dia |
| 10 | (f) 15 mm dia |
| 11 | Supply and laying in trenches GI tubing medium grade with all fittings (such as bend, elbow, tees, connectons, short pieces, bak nuts, union, valve, caps and plugs etc) for pipe complete all as specified and directed for the following sizes :- (a) 80 mm dia |
| 12 | (b) 50 mm dia |
| 13 | (c) 40 mm dia |
| 14 | (d) 32 mm dia |
| 15 | (e) 25 mm dia |
| 16 | (f) 20 mm dia |
| 17 | (g) 15 mm dia |
| 18 | M&L for making good the leaking of upto 150mm bore GI/CI pipe lines by welding all around the pipe , thickness of metal to be welded exc 9mm but n exc 20mm respectively including all necessary excavation and earth work removal of old joints etc complete all as specified and directed. Loc : PumpHouse, Haldwani , Ranibagh, Kamola |
| 19 | Taking out sluice valve suitable for 150 mm bore pipe from valve pit for re-facing & re-grinding and re-fixing, including all jointing material such as nut, bolts, washers, rubber gasket/packing 6 mm thick, including glan packing etc and as required at site complete all as specified and directed. Loc : Pump House, Haldwani, Ranibagh & Kamola |
| 20 | All as per item No 8 herein before but of size 100 mm size sluice valve. |
| 21 | All as per item No 8 herein before but of size 80 mm size sluice valve. |
| 22 | Taking out old u/s sluice valve from valve pit or vertical line of O/H tank valve and supply, Install, commissioning and testing of 150 mm size sluice valve of cast iron body flanged & drilled conforming to IS-14846, PN-1 with stainless steel spindle including all accessories such as nut-bolts, washers & fibre/rubber gasket as required at site complete all as specified and directed. |
| 23 | As same as ser No 11 but of size 100mm size sluice valve |
| 24 | As same as ser No 1 1 but of size 80mm size sluice valve |
| 25 | Removing water meters, any pattern from bore of pipes 20mm by unserewing unions , fitting unions with screw plugs, or inserting short or tubing screwed both ends so as to maintain supply all as specified and directed. Note ;- After removing all water meters will be deposited to MES store by the contracter. |
| 26 | M&L for de-watering of 100000 Glns capacity under ground water sump including removing fungus, scales slurry etc from the inside wall of the sump, taking out sludge, mud clay deposited at the bottom of the sump and removing the same to a distance not less than 50 mtr, washing the walls of the sump with water and chemical salt as bleaching powder etc and Applying two coat of lime washing on all the internal surfaces of the tank and two coat of cement base on external surfaces of approved make and shade snowcem on all the outside surfaces of the tank and one coat of synthetic enamel paint over the iron/steel surfaces. The entire job is to carried out all as specified and directed by Engr-in-chage. Loc : Haldwani Note :- (i) The contractor shall write the date on which the tank is cleaned with white synthetic enamel paint in bold letter and back ground shall be painted with black paint on wall of UG Tank. (ii) Rate quoted by the contractor shall deemed to be included the same and no extra payment shall be made on this account. |
| 27 | All as per item No 22 herein before but 50,000 Glns capacity. Loc : Haldwani |
| 28 | M&L for cleaning of RCC overhead tank of capacity 10000 Glns on 15 Mtr staging from inside, extraction of dust/sand/mud/algae deposits, making it free from algae growth by scrapping and washing with water including or cleaning of the out side surfaces and area surrounding the tank including drains etc. Applying two coat of lime washing on all the internal surfaces of the tank and two coat of cement base on external surface including staging of approved make and one coat of synthetic enamel paint over the iron/steel surfaces. The entire job is to carried out all as specified and directed by Engr-in-chage. Loc : Ranibagh/KamolaNote :- (i) The contractor shall write the date on which the tank is cleaned with white synthetic enamel paint in bold letter and back ground shall be painted with black paint on wall of OH Tank. (ii) Rate quoted by the contractor shall deemed to be included the same and no extra payment shall be made on this account. |
| 29 | All as per item No 21 herein before but capacity 25000 Glns. Loc : F/Qty, Haldwani |
| 30 | All as per item No 21 herein before but capacity 50000 Glns. Loc : R&O Area, Haldwani |
| 31 | Taking out old u/s cast iron Non return valve of any type and size for replacement and supplying, fixing, testing and commencing non return valve suitable for 100 mm bore pipe (suction line) both ends flanged including nut bolts, gasket and washer from sump and pump house bldg complete all as specified and directed. Loc : Pump House Haldwani, Ranibagh & Kamola |
| 32 | Material & Labour for repair and overhauling of elect motor 30 HP capacity installed with pump set at pump house, Haldwani comprising of the following works :-(a) Dismantling of 30 HP elect motor 3 phase, 440 volts from foundation and taking away local works shop and transporting back the same after repairs.(b) Opening of motor winding, cutting of burnt coils and cleaning of slots complete all as specified and directed.(c) Applying one coat of red oxide primer, fixing of packing with Pnumax paper and green sheet of glass cloth, rewinding with suitable gauge of super enamelled insulated wire (Appx qty- 25 Kg)(d) Making suitable Star/Delta connections for three phase wiring with 6 Sqmm x 6 run (Appx 24 RM) of FRLS wire incl PVC pipe and pin type lugs complete all as specified and directed.(e) Varnishing with doctor bake varnish, during backtrol and heating properly complete all as specified and directed(f) Replacement of u/s rubber star coupling and providing new pin bush coupling complete all as specified and directed. - 01 Nos (g) Repair of Main shaft of pump. |
| 33 | (h) Replacement of Pump bearing suitable size and fillup greesh for lubrication complete all as specified and directed. - 02 Nos (j) Repalcement of imppellers suitable size. - 02 Nos (k) Replacement of pump bushes of suitable size.(l) Replacement in repair Gland packing, greasing to brgs.Notes :- Standby electric motor of 30 HP should be provided by contractor at the site without any extra cost. |
| 34 | All as per item No.27 hereinbefore but electric motor of capacity 20 HP installed at MES pump house Haldwani complete all as specified and directed. |
| 35 | All as per item No. 27 hereinbefore but electric motor of capacity 7.5 HP installed at Ranibag complete all as specified and directed. |
| 36 | Material & Labour for servicing of silent DG set capacity 250 KVA (Three phase diesel engine driven Generator set) complete all as specified and directed. Comprising of the following works :-(a) Overhauling of Self starter assy including required defective part.(b) Replacement of engine oil filters -02 Nos (c) Replacement of diesel filters - 02 Nos (d) Replacement of Air filter - 01 Nos. (e) Replacement of engine oil of required cap with specified grade - 26 Ltr (Approx)(f) Replacement of alternator carbon bushes.(g) Fan belt as per sample - 03 Nos (h) Replacement of alternator bearing of required size - 02 Nos (j) Replacement slipering assy - 01 Nos (k) Replacement of coolant of required cap.(i) Replacement of Battery 12 V, 180 Ah - 02 Nos (m) Replacement of proximate coolant sensor complete with wiring connection. (n) Replacement of LOP (Low oil pressure) indicator sensor - 01 Nos (o) Replacement of door lock - 04 Nos (p) Replacement of fuel tank cap with lock - 01 Nos (q) Replacement of unserviceable ARB card - 01 Nos |
| 37 | Material & Labour for servicing of silent DG set capacity 160 KVA (Three phase diesel engine driven Generator set) complete all as specified and directed. Comprising of the following works :-(a) Overhauling of Self starter assy including required defective part.(b) Replacement of engine oil filters -02 Nos (c) Replacement of diesel filters - 02 Nos (d) Replacement of Air filter - 01 Nos. (e) Replacement of engine oil of required cap with specified grade - 25 Ltr (Approx)(f) Replacement of alternator carbon bushes.(g) Fan belt as per sample - 03 Nos (h) Replacement of alternator bearing of required size - 02 Nos (j) Replacement slipering assy - 01 Nos (k) Replacement of coolant of required cap.(i) Replacement of Battery 12 V, 180 Ah - 02 Nos (m) Replacement of proximate coolant sensor complete with wiring connection. (n) Replacement of LOP (Low oil pressure) indicator sensor - 01 Nos (o) Replacement of door lock - 04 Nos (p) Replacement of fuel tank cap with lock - 01 Nos (q) Replacement of unserviceable ARB card - 01 Nos |
| 38 | All as per item No 25 herein before but 30 KVA at Ranibagh all as specified and directed . |
| 39 | All as per item No 25 herein before but 25 KVA at Ranibagh all as specified and directed . |
| 40 | All as per item No 25 herein before but 7.5 KVA at Ranibagh all as specified and directed . |
| 41 | Supply only Puri Chlor brand Calcium Hypo Chlorite 65-70% Chlorine content in granular and tablet from disinfectant for water treatment in 45 kg Drums Sree Rayalaseema HI- Strenght Hypo Ltd. Or equivalent make and brand as mentioned in latest approved list of E-in-C br New Delhi and Cheif engineer central command all as specified and directed |
| 42 | M&L in repair for opening of CI sluice valve of 150 mm size any type for replacement of defective spindle with stem and providing new spindle with stem made of stainless steel duly machine threaded, heat treated and shaped including cast iron handwheel and making good the stuffing box with suitable size of gland packing and greasing at Haldwani & Ranibagh complete all as specified and directed. |
| 43 | All as per item No 27 herein before but of size 100 mm size sluice valve. |
| 44 | All as per item No 27 herein before but of size 80 mm size sluice valve. |
| 45 | Excavation in trenches by manually or mechanical method n.exc. 10 Sqm on plan, exc. 1.5 m deep but n.exc. 3.0m in deep for foundation etc. in any type of soil including taking out old filler material from the mild steel pipe joint including cleaning of joints and making the joints completely water tight and air tight by means of lead joint & filler material to the entire satisfaction of Engineer in charge including retuning/ filling, to be done after joints are sealed complete all as specified and directed. Note :- The rate quoted by the contractor shall deemed to included of all T & P and material , nothing extra shall be paid. |
| 46 | M & L in repair for complete dismantling of u/s water level indicator of UG Sump & OH tank including M & L for replacing the same indicater made out of angle iron frame MS SHEET 1.6 mm steel rope of suitable gauge/size 4mm MS indicator of suitable size copper float valve of 230mm dia MS pully for smooth operation of steel rope including painting the complete frame and making the scale suitable for the 0.5/1.0 lakh glns capacity at Haldwani |
| 47 | M & L for repair and replacement of contactor/relay with necessary connected partrs including wire in startor panel of 30 HP at pump house Haldwani |
| 48 | M & L for repair and replacement of contactor/relay with necessary connected partrs including wire in startor panel of 20 HP at pump house Haldwani Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender