Tender For Addn/Altn To Lt Infrastructure Incl Lt Panels And Allied Items Near Mafi Ph-I And Base Ops Area At Afs Hasimara
Tender Value
44 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
12 days left
EMD
88000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalpaiguri → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Addn/Altn To Lt Infrastructure Incl Lt Panels And Allied Items Near Mafi Ph-I And Base Ops Area At Afs Hasimara
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority:GE (AF) HASIMARA Name of Work : ADDN/ALTN TO LT INFRASTRUCTURE INCL LT PANELS AND ALLIED ITEMS NEAR MAFI PH-I AND BASE OPS AREA AT AFS HASIMARA Contract No: GE/HAS/ /2026-27 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE 'A' (BoQ)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 metre in depth for foundation of pole/stay, or cable trenches etc n. exc. 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed. |
| 3 | Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed. |
| 4 | Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed. |
| 5 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of cross sectional area 400 Sqmm 3.5 core, complete all as specified and directed.Note : Cable protection pipe/cable cover, etc shall be measured and paid seperately. |
| 6 | All as per item No 4.00 here-in before but cross sectional area 240 Sqmm, 3.5 core, complete all as specified and directed. |
| 7 | All as per item No 4.00 here-in before but cross sectional area 95 Sqmm, 3.5 core, complete all as specified and directed. |
| 8 | All as per item No 4.00 here-in before but cross sectional area 70 Sqmm, 3.5 core, complete all as specified and directed. |
| 9 | All as per item No 4.00 here-in before but cross sectional area 50 Sqmm, 3.5 core, complete all as specified and directed. |
| 10 | All as per item No 4.00 here-in before but cross sectional area 35 Sqmm, 3.5 core, complete all as specified and directed. |
| 11 | Supply and laying double walled corrugated (DWC) HDPE duct pipe of 50mm outer dia, heavy duty, conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed. |
| 12 | Supply and laying double walled corrugated (DWC) HDPE duct pipe of 90mm outer dia, heavy duty, conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed. |
| 13 | S&F factory fabricated busbar chamber, outdoor type, made out of 3.15mm thick CRCA sheet with powder coating of size not less than 0.8 x 0.6 x 0.4m for set of 04 aluminium busbar 200 Amps rating, supported with suitable size heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral, The chamber shall be fixed 90cm above the normal ground level complete with PCC foundation with and including PCC (1:2:4 ) type B2, of required size, as recommended by OEM, complete all as specified and directed. |
| 14 | S&F factory fabricated onload change over LT panel of capacity 200 Amp with rotary handle outdoor type, made out of 2mm thick CRCA sheet with powder coating of size not less than 0.8 x 0.6 x 0.4m with suitable size of GI nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral, fixing arrangement of the panel shall be with and including angle iron 50 x 50 x 6mm on floor/wall, complete all as specified and directed. |
| 15 | S&F factory fabricated onload change over switch of capacity 100 Amp with stainless steel encloser with suitable size of GI nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral, fixed to wall with necessary fixing arrangement, complete all as specified and directed. |
| 16 | Supply, fabrication, installation, testing and commissioning of outdoor type LT feeder pillar box of size 1000(H) x 900(W) x 400(D)mm, factory fabricated, wall/floor mounted double door, dust and vermin proof CPRI approved inner parts made of 2.00mm thick CRCA sheet and outer shell of 3.15mm thick CRCA sheet, having rain canopy type, four side slop top, suported on 50 x 50 x 6mm angle iron base frame and legs of 500mm height, painted with texured powder coated paint of thickness not less than 100 micron, after preparation of surface in 8 tank sheet process system with copper bus bar & strips of size 800 Amp current capacity, calculated by using formola current capacity (Amp) = cross-sectional area (Sqmm) x 1.2 A/Sqm all outgoing switchgears shall have extended strips for easy and comfortable outgoing connection, wiring shall be completed with sockets and ferrule markings, front and back openable including locking arrangement including suitable size copper conductor control wiring, necessary cable glands, lugs etc, proper arrangement for ventilation including PCC foundation as per OEM recommendation, with and including the following accessories :-INCOMING:(i) MCCB 630 Amps, AC, 4 pole 415 Volt, 36 KA Breaking capacity, Ics = 100% Icu, 50 Hz with thermal magnetic release range 100A, with suitable rotary extendable handle for operation of MCCB-01 No.(ii) CT coil 30/5 - 03 Nos.(iii) Digital multi function Meter 0- 500 Volt (4405 series) - 01 No.(iv) RYB Indicating (LED) lamps -03 Nos.(v) MCB SP 6 Amp 'C' curve, 10 KA - 01 No.OUTGOING:(i) Onload change over switch 630 Amp, 4 pole - 01 No. |
| 17 | M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping of poles etc finished the concrete surfaces fair and even including formwork (as required), complete all as specified and directed. |
| 18 | M& L for power cable route marker pre-cast RCC of size 1500mm x 300mm x 50mm with top curved portion, 8mm dia round bar reinforcement, emboshing of letter (MES-POWER CABLE) both faces of pre-cast during casting of RCC precast, applying two coats of weather proof exterior emulsion paint over a coat of primer, approved colour and painting of emboshed surface with exterior emulsion black paint over a coat of primer including necessary earth work and excavation for fixing of route marker, complete all as specified and directed. |
| 19 | M &L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.0cm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to GI earth strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part -1, including necessary excavation and earth work, P.C.C (1:3:6) type C-1 with 50mm thick Pre-cast R.C.C. (1:2:4) type B1 cover slab (reinforced with 8mm dia deformed bar 10cm C/C both ways and suitable handle of 10mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around the earth electrode, with funnel and 20mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, Gl earth wire protected by 40mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including dismantling of old unserviceable earthing of any descriprtion, complete all as specified and as directed.Note : GI earth strip from earth pit to pole/LT panel/DB shall deemed to be included in the unit quoted rate. |
| 20 | Horizontal boring under the road (with manual method) below 1mtr from the road surface and dia of hole not exc. 120mm, without damaging the existing road, getting out and disposal off excaveted materials (soil) to a distance not exceeding 50m from the site of work, complete all as specified and directed. |
| 21 | S&F GI tubing 100mm bore, light grade, (ISI marked) with all fittings for protection of cables, laid in trenches, road crossing etc. including making good to the distrurbed surfaces, complete all as specified and directed Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysSep 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender