Defence Statutory Bodies & Commissions/Committees Closing in 4 days TDR #56885111

Tender For special Repair To Lt Network & External Water Supply System At Nagtalao Under Ge Banar

Issued by Statutory Bodies & Commissions/Committees · Jodhpur, Rajasthan
Tender Value
38.50 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
4 days left
EMD
77000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Lt Network & External Water Supply System At Nagtalao Under Ge Banar

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 20-Aug-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-Aug-2026

BOQ

Name of Work:- SPL REPAIR TO LT NETWORK & EXTERNAL WATER SUPPLY SYSTEM AT NAGTALAO UNDER GE BANAR
Sl. No. Item Description
1Dismantling and taking down Old Prestressed concrete pole, 9.0 metres long, including street light,bracket and junction box complete all as specified and directed by Engr-in-Charge.
2Dismantling old rusted Earthing set complete all as specified and directed by Engr-in-Charge.
3Taking up of old aluminium Conductor of any size complete all as specified and directed by Engr-in-Charge.
4Taking up of old Al armoured cable up to 35 sqmm complete all as specified and directed by Engr-in-Charge.
5Taking up of old HDPE/GI pipe complete all as specified and directed by Engr-in-Charge.
6Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth for taking out and laying pipe lines/cables not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and directed by Engr-in-Charge.
7Excavation in trenches in Hard Rock not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth for taking out and laying pcc poles/cables not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and directed by Engr-in-Charge.
8Returning, filling in, including spreading, watering and well ramming in layers not exc 25cm in any type of soil complete all as specified and directed by Engr-in-Charge.
9Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
10M&L for tibba sand locally available sand filling in trenches dry and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed by Engr-in-Charge. Note :- Only punned thickness shall be measured for payment purpose.
11M&L for laying jodhpur stone quarry stone slab cover 25 to 30 cm in width, 60cm long and 40 to 50 mm thick laid in trenches and over sand covered under ground cables complete all as specified and directed by Engr-in-charge.
12Material and labour plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in base of the pole or in any situation complete all as specified and directed by Engr-in-Charge.
13Material and labour plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of the pole or in any situation complete all as specified and directed by Engr-in-Charge.
14M&L Cement concrete in foundations, filing, mass concreting etc., PCC 1:4:8 type D2 using 40 mm graded aggregate complete all as specified and directed by Engr-in-Charge.
15Supply and errecting of Prestressed concrete pole, 9.0 meter long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 including painting alternative black & white strips of 30 cm width upto 1.5 mtr above ground level all as required at site or complete all as specified and directed by Engr-in-Charge.
16Material and labour for edging the machine cut /true dressed jodhpur stone patty of size 30 cm in width, 60 cm long and 50 mm thick, to make edge aroung the LT Panels and complete all as specified and directed by Engr-in-Charge.
17Supply and laying the graded coarse aggregate 40mm size for loose filling around the LT Panels surface dressing and cleaning the vegetation before spreading the gravel and complete all as specified and directed by Engr-in-Charge.
18M&L for Cutting the road / hard standings/Interlocking bricks and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable/pipe including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete and matching with the surroundings complete all as specified and directed by Engr-in-Charge.
19Supply and fixing the LT Cable route indicator made by Jodhpur stone well finished and marking of letter \\"DANGER LT Cable MES\\", size 100mmx10mm, 75cm long, 15cm grouted with 1:3:6 PCC foundation below the ground level and 60cm of marker will be elevated on ground. letters of \\"DANGER LT Cable MES\\" will be painted with post office red colour and with black colour background andcomplete all as specified and directed by Engr-in-Charge.
20Supply,Laying and testing in trenches or fixing or passing through pipe 1100 volts grade heavy duty cable XLPE Insulated multi stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and over PVC sheathed of following sizes complete all as specified and directed by Engr-in-Charge. Note:- Excavation , cable cover, sand and earth work will be paid saperately.
213.5 core 185 Sq mm
223.5 core 120 Sq mm
233.5 core 95 Sq mm
243.5 core 35 Sqmm
254 core 25 Sqmm
264 core 16 Sqmm
272 core 16 Sqmm
28Material and labour for 100 mm dia galvanized iron pipe Light grade for cable protection pole ,plinth protection, road crossing, trenches, footpath etc, ccomplete all as specified and directed by Engr-in-Charge including clamps, nut bolt and washers.
29Material and labour for 80 mm dia galvanized iron pipe Light grade for cable protection pole ,plinth protection, road crossing, trenches, footpath etc, complete all as specified and directed by Engr-in-Charge including clamps, nut bolt and washers.
30Material and labour for 50 mm dia galvanized iron pipe Light grade for cable protection pole ,plinth protection, road crossing, trenches, footpath etc, complete all as specified and directed by Engr-in-Charge including clamps, nut bolt and washers.
31Supply and laying high density polyethylene pipe 40mm internal dia (HDPE) of pressure rating 6 kg/sq cm including all fittings laid in trenches or on wall with clamps complete with all fittings for passing of LT cable complete all as specified and directed by Engr-in-Charge.
32Supply and fixing led street light of capacity 70 watt, having pressure die cast aluminium housing, ip-66, having efficiency of ≥ 110 lumens/watt, operating voltage – 120 – 277 ~ volts, p.f ≥ 0.95, t.h.d < 10 %, surge protector 10 kv ( in fixture housing ). driver of the fitting must be potted type only and must have features like – apfc for power factor correction , inbuilt surge arrestor (in driver ) 5 kv, over voltage protection ≥300 vac, 440v withstand for continuous 8 hrs. both fixture and driver must have separate bis marked registration number and must be clearly mentioned on fixture & as well as on driver also. the fitting must be suitable for 35 to 50 mm o.d mounting pipe and suitable for mounting on wall / pole with necessary mounting arrangements ) including connecting up with three core twisted flexible copper conductor cable with suitable size, mounting pipe/bracket , nut, bolts and accessories including disconnected & taking down old unserviceable light complete. the manufacturer of the led fitting shall have inhouse nabl accrediated lab & contractor shall furnish same along with lm-79,lm-80, test report etc. complete all as specified and directed by Engr-in-Charge.
33S&F in replacement of 32 mm dia GI pipe bracket (medium grade) bent to shape of length not less than 1.2 mtr including fixing on pole using flat iron 25x3 mm size clamps 2 Nos of suitable size nuts,bolts,washers etc includig paint of two coats of alluminium paint over one coat of red oxide primer suitable for street light fittings complete all as specified and directed by Engr-in-Charge.
34Supply and Fixing of pole mounted junction box of inside dimension 240x130x110 made out of FRP body (hot mulded type) with IP-55 protection and locking with screws alongwith 5/6 Amp rating MCB SP-01 No, 4 pole connector suitable to insert the cable size up to 16 Sqmm-01 No,with neutral link and din rail suitable for mounting the MCB/Connector etc complete in side box and duly fixed on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and out going cales and complete all as specified and directed by Engr-in-Charge.
35Supply & fixing of PVC insulated, sheathed weather proof, copper conductor of size 1.5 sqmm, 3 core complete all as specified and directed by Engr-in-Charge.
36Supply & fixing of PVC conduit 20 mm, heavy duty rigid non metallic including of all tee, bends, elbows etc complete all as specified and directed by Engr-in-Charge.
37Supply and fix in repairs of automatic street light/security light switch for Three phase load of 5-8 KW,using infra red sensor based nature switch for automatic switching of street lights. nature switch operation should be based on natural light lux level . required illuminence level for switcing on is -< 30 lux for > 30 sec and for switching off >- 10 lux for > 30 sec . the sensor should also have part night operation facility of minimum 4 hrs to maximum 12 hrs. the sensor along with 03 Nos contactor each of 20 to 25 amps, Incoming MCB and out going MCB's of 20-25 Amps (03 Nos) and auto manual (Senser by pass), size of circuit wiring should be multistanded FRLS min size of 10 sqmm, selection option should be enclosed in a pole /wall mountable enclosoure made of rust proof , electric shock proof, termite proof and FR grade special moulding compund( Sintex made SMC Junction box) confirming to IP 66 and model Swadeep-66-5KW3P, complete all as specified and directed by Engr-in-Charge.
38Supply and installation, testing and commissioning LT feeder pillar box suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC Supply outdoor type IP-65 floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 600 A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 75 cm made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears complete all as specified and directed by Engr-in-Charge. INCOMING:- MCCB 4P 400 Amp 36 KA thermal adjustable type OUTGOING :- (i) MCCB 4P 200 Amp 36 KA thermal adjustable type -03 Nos, MCCB 4P 63 Amp 16 KA thermal adjustable type-01 No, Nos,Digital type volt meter & Amp Meter, LED type Indicating Lamp (03 Nos)
39Supply and installation, testing and commissioning LT feeder pillar box suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC Supply outdoor type IP-65 floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 250 A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 75 cm made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears complete all as specified and directed by Engr-in-Charge. INCOMING:- MCCB 4P 160 Amp 36 KA thermal adjustable type OUTGOING :- (i) MCCB 4P 63 Amp 16 KA thermal adjustable type-05 No, Nos,Digital type volt meter & Amp Meter, LED type Indicating Lamp (03 Nos)
40Supply and installation, testing and commissioning LT feeder pillar box suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC Supply outdoor type IP-65 floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 250 A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 75 cm made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears complete all as specified and directed by Engr-in-Charge. INCOMING:- MCCB 4P 160 Amp 36 KA thermal adjustable type OUTGOING :- (i) MCCB 4P 63 Amp 16 KA thermal adjustable type-07 No, Nos,Digital type volt meter & Amp Meter, LED type Indicating Lamp (03 Nos)
41Supply and installation, testing and commissioning LT feeder pillar box suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC Supply outdoor type IP-65 floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 250 A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 75 cm made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears complete all as specified and directed by Engr-in-Charge. INCOMING:- MCCB 4P 160 Amp 36 KA thermal adjustable type OUTGOING :- (i) MCCB 4P 100 Amp 25 KA thermal adjustable type-02 No, MCCB 4P 63 Amp 16 KA thermal adjustable type -06 Nos,Digital type volt meter & Amp Meter, LED type Indicating Lamp (03 Nos)
42Supply and installation, testing and commissioning LT feeder pillar box suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC Supply outdoor type IP-65 floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 250 A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 75 cm made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears complete all as specified and directed by Engr-in-Charge. INCOMING:- MCCB 4P 125 Amp 25 KA thermal adjustable type OUTGOING :- (i) MCCB 4P 63 Amp 16 KA thermal adjustable type -06 Nos,Digital type volt meter & Amp Meter, LED type Indicating Lamp (03 Nos)
43Supply and installation, testing and commissioning LT feeder pillar box suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC Supply outdoor type IP-65 floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 150 A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 75 cm made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears complete all as specified and directed by Engr-in-Charge. INCOMING:- MCCB 4P 100 Amp 25 KA thermal adjustable type OUTGOING :- (i) MCCB 4P 63 Amp 16 KA thermal adjustable type -02 Nos,Digital type volt meter & Amp Meter, LED type Indicating Lamp (03 Nos)
44M & L for earthing complete with galvanised steel earth plate electrode 60 x 60x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron strip 32x6mm as earthing lead as shown in Electrical Plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI medium grade water pipe, 40 mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation of hard /dense soil and earth work pit cover including disposal of surplus soil to a distance not exceeding 50m, complete testing on completion all complete as shown in electrical plate No 3 of SSR Part I 2009 complete all as specified and directed by Engr-in-Charge.
45M & L for building earthing complete with galvanised steel earth plate electrode 60 x 60x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron wire 4mm as earthing lead as shown in Electrical Plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in hard/dence soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI medium grade water pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not exceeding 50m, complete testing on completion all complete as shown in electrical plate No 3 of SSR Part I 2009 complete all as specified and directed by Engr-in-Charge.
46Supply and laying galvanized steel tubing, medium grade including all fittings laid in trenches complete all as specified and directed by Engr-in-Charge of 50mm bore of pipe.
47Supply and laying galvanized steel tubing, medium grade including al fittings laid in trenches complete all as specified and directed by Engr-in-Charge of 40mm bore of pipe.
48Supply and laying galvanized steel tubing, medium grade including al fittings laid in trenches complete all as specified and directed by Engr-in-Charge of 20mm bore of pipe.
49Supply and fix in replacement Gun metal gate valve, painted finish with forged brass spindle and iron wheel head, screwed both end internally IS -778 marked class 2 for iron pipe of size 50 mm bore complete all as specified and directed by Engr-in-Charge.
50Supply and fix in replacement Gun metal gate valve, painted finish with forged brass spindle and iron wheel head, screwed both end internally IS -778 marked class 2 for iron pipe of size 40 mm bore complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56885111
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 38.50 Lakhs
LAST DATE 27-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Lt Network & External Water Supply System At Nagtalao Under Ge Banar
Basic Detail
Tender No CWE (A) JODH/BNR- OF 2026-27(82627/32/E8)
Bidding Type Tender
Location
City Jodhpur
State Rajasthan
Key Dates
Publish Date 20 Aug 2026
Submission Date 27 Aug 2026
Open Date 29 Aug 2026
Finance
Tender Value 38.50 Lakhs
Tender Fee 500
EMD 77000
Exemption Available
Document List
5a603265-2c45-4d4b-a34d-c522122e1bd9.html
BOQ_877268.xls
TENDER32.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 27, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

5a603265-2c45-4d4b-a34d-c522122e1bd9.html

xls

BOQ_877268.xls

pdf

TENDER32.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders