Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #56885090

Tender For special Repair Of Bldg No T-696 (Recreation Hall) And T-145 (R&I) Sec For Electrical Rewiring Of 184 (I) Fd Wksp Coy Eme , special Repair To Bldg No T-415 (Sa, Tcm & Opto Sect) Of 184 (I) Fd Wksp Coy Eme And special Repair To Underground C

Issued by Statutory Bodies & Commissions/Committees · Leh, Ladakh
Tender Value
9.75 Lakhs
Estimated cost
Bid Submission
25 Aug 2026
2 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Leh → Ladakh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for special Repair Of Bldg No T-696 (Recreation Hall) And T-145 (R&I) Sec For Electrical Rewiring Of 184 (I) Fd Wksp Coy Eme , special Repair To Bldg No T-415 (Sa, Tcm & Opto Sect) Of 184 (I) Fd Wksp Coy Eme And special Repair To Underground Cable Main Supply Cable 4 Core 25 Sqmm From Generator Room To Wksp Repair Bay/All Section With Bus Bar And Main Electrical Mcb Of 184 (I) Fd Wksp Eme At Nimu Mil Stn Under Age (I) Nimu

BOQ

Name of Work:- SPL REPAIR OF BLDG NO T-696 (RECREATION HALL) AND T-145 (R&I) SEC FOR ELECTRICAL REWIRING OF 184 (I) FD WKSP COY EME , SPL REPAIR TO BLDG NO T-415 (SA, TCM & OPTO SECT) OF 184 (I) FD WKSP COY EME AND SPL REPAIR TO UNDERGROUND CABLE MAIN SUPPLY CABLE 4 CORE 25 SQMM FROM GENERATOR ROOM TO WKSP REPAIR BAY/ALL SECTION WITH BUS BAR AND MAIN ELECTRICAL MCB OF 184 (I) FD WKSP EME AT NIMU MIL STN UNDER AGE (I) NIMU
Sl. No. Item Description
1Taking down carefully aluminium/Copper point wiring light, fan socket or power complete fitting such as switches, ceiling rose, fan regulator, socket including light fitting etc complete with /PVC /MS conduit and T/W battern / casing caping and all as specified and as directed by Engineer-in-Charge.
2Taking out old unsv Service wiring of any size/make/ type etc from excavted tranches/ on pole passing through pipes etc from different locations complete all as specified and directed by the engr in charge.
3Supply and laying or fixing or passing through pipe, 16sq mm 2core 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm 2 CORE nominal cross section in service connections complete all as specified and directed by the engr in charge.
4M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-(a) One light point/one fan point controlled by one switch
5M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-(b) One 3 pin 5 amps socket outlet independent with cables 2.5 sqmm size
6M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-(c) One 3 pin 5 Amp socket outlet on same board with cables 2.5 sqmm size
7All same as per item No 5 above but with conductor of size 4 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 4 sqmm PVC insulated stranded copper conductor Cable complete all as specified and directed by the engr in charge.
8S&F Socket 2 in 1, 5 pin 5 Amp flush type complete all as specified and directed by Engr In Charge.
9S&F Switch piano flush type 5 Amp, single pole, one way complete all as specified and directed by Engr in Charge.
10S&f Switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed by Engr in Charge .
11S&F Switch Socket Combination 2 in 1, 3 pin, 15/16 amp flush type Universal complete all as specified and directed by Engr in Charge .
12M&L for ceiling rose surface Bakelite 65x50mm two to three terminal complete all as specified and as directed by Engr-in-Charge.
13S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and directed by Engr in Charge.
14S&F basic all purpose surface and wall mounted LED batten with polycarbonate housing and integreted electronic driver of cap 10 watt, 2 feet long, with all accessories complete all as per specified and as directed by Engr-in-Charge.(Havells Cat Pt No. - LHEXACP7IN1W010 or equivalent in Philips/Crompton) complete all as specified and directed by the engr in charge.
15Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor all as per specified and as directed by Engr in Charge.
16S&F basic all purpose surface and wall mounted LED batten with polycarbonate housing and integreted electronic driver of cap 20 watt, 4 feet long, with all accessories complete all as per specified and as directed by Engr-in-Charge.(Havells Cat Pt No. - LHEXAXPNIN1W020 or equivalent in Philips/Crompton) complete all as specified and directed by the engr in charge.
17S&F in repair sheet metal powder coated versatile Double door SPN distribution board, 12 way suitable for MCB's fitted with copper bus bar rated 200amps, neutral link , earth bar and din rail suitable for use on 240 Volt, 50Hz all as directed by Engr in Charge.(FOR lighting load) complete all as specified and directed by the engr in charge.
18M&L in repair for MCB SPN 63 Amp, 240V with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
19S&F in repair to MCB SP 6-32 Amp with 10KA breaking capacity of 'C' series in distribution boards with all accessories complete all as per specified and as directed by Engr-in-Charge.
20Supply and fix in repair electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed by the engr in charge.
21Dismantling and Taking down old u/s street / building sequrity Light fittings from poles, flood lights, post top lantern lights and garden lights for replacement with LED fittings all as specified and as directed by Engr in Charge.
22Supply and fix LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete Specified and directed by Engr in charge.
23M&L for GI bracket 1.5 mtr long made out of GI pipe 40mm dia bend to suitable radius incl clamps nuts bolts washers incl painting with aluminum paint etc complete all as specified and directed by Engr in charge.
24Supply and fix in replacement of exhaust fan, engineering plastic body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm AC single phase with, blades, and frame and louvers of size 300 mm sweep all as per specified and as directed by Engr-in-Charge.
25M & L in repair for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to MS galvanized earh strip of size 25 x 4 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, GI strip laid in dia 40 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit (30X30X30cm) with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified.
26Taking out old unserviceable underground cable of any size/ make/ type etc from excavated trenches/ on poles/ passing through pipes etc from different locations complete all as spd.
27Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core
28Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge.
29Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge.
30Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge.
31Material and labour for un reinforced pre cast concrete cable cover class LV type I, flat size 250 mm x 150 mm x 40 mm.
32M&L Sand cushioning to under ground cable complete all as specified in clause 19.75 of SSR Part - I.
33Dismantling and Taking down LT U/S panels incl all outgoing and incoming connections and making good the disturbed area from site all as specified and directed by Engineer-in-Charge.
34M&L for Busbar chambers with 4 aluminium busbar strip of rating 400 Amp 6 way fixed on angle iron of size 40mm x40mm x5mm complete all as specified and directed by Engineer in Charge.
35M & L for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to MS galvanized earh strip of size 32 x 6 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified.
36S&F in repair Air termination, single pointed, copper rod 12mm dia and 300mm long different locations / Bldg complete all as specified and directed by the engr in charge.
37S&F in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by the engr in charge.
38S&F in repair Galvanised earth lead wire 4.0mm dia for roof conductors and down conductors above ground complete all as specified and directed by the engr in charge.
39Supply and fix in repair laying 32 mm light grade GI Tubes in trenches/on wall/ poles/ structures as in repairs GI tubeing light grade for road crossing/ for cable protection / fixing of pigmi lights etc, of the folling size including necessary provision for cable / Strip entry if reqd in pigmi lights pole fixinf screws / clmp complete as required complete all as specified and directed by Engr in Charge.
40M & L in repair for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to MS galvanised earth lead wire 4.0mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, GI strip laid in dia 40 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit (30X30X30cm) with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified.
41Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and as directed by the Engineer - in - Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56885090
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 9.75 Lakhs
LAST DATE 25-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair Of Bldg No T-696 (Recreation Hall) And T-145 (R&I) Sec For Electrical Rewiring Of 184 (I) Fd Wksp Coy Eme , special Repair To Bldg No T-415 (Sa, Tcm & Opto Sect) Of 184 (I) Fd Wksp Coy Eme And special Repair To Underground Cable Main Supply Cable 4 Core 25 Sqmm From Generator Room To Wksp Repair Bay/All Section With Bus Bar And Main Electrical Mcb Of 184 (I) Fd Wksp Eme At Nimu Mil Stn Under Age (I) Nimu
Basic Detail
Tender No AGE(I)/NIT-46/2026-27
Bidding Type Tender
Location
City Leh
State Ladakh
Key Dates
Publish Date 06 Aug 2026
Submission Date 25 Aug 2026
Open Date 27 Aug 2026
Finance
Tender Value 9.75 Lakhs
Tender Fee 500
EMD 20000
Exemption Not Available
Document List
3b3f4b4d-9e34-46b4-a378-1d4c7d250762.html
BOQ_877258.xls
TENDER.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Aug 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

3b3f4b4d-9e34-46b4-a378-1d4c7d250762.html

xls

BOQ_877258.xls

pdf

TENDER.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders