Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56885058

Tender For Provn/Addn/Alt Of Perimeter Security Wall With Guard Posts, Guard Rest Room And Security Lights At Certain Locations At Af Stn Awantipur.

Issued by Statutory Bodies & Commissions/Committees · Pulwama, Jammu and Kashmir
Tender Value
10.50 Crore
Estimated cost
Bid Submission
10 Sep 2026
18 days left
EMD
8.55 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pulwama → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn/Addn/Alt Of Perimeter Security Wall With Guard Posts, Guard Rest Room And Security Lights At Certain Locations At Af Stn Awantipur.

BOQ

Name of Work:- PROVN/ADDN/ALT OF PERIMETER SECURITY WALL WITH GUARD POSTS, GUARD REST ROOM AND SECURITY LIGHTS AT CERTAIN LOCATIONS AT AF STN AWANTIPUR.
Sl. No. Item Description
1SCHEDULE `A' PART-I (BUILDING WORK)
2Total amount of Sch 'A' PART-I (Sec-I) (BUILDING WORKS)
3Total amount of Sch 'A' PART-II (Sec-I) (INTERNAL ELECTRIC SUPPLY WORKS)
4SCHEDULE `A' PART-II (Sec-II) (INTERNAL ELECTRIC SUPPLY WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs. 0.00\\" under Col.5 signifies this fact only.
5Supply and fixing switch piano flush type (ISI marked), single pole, two way, 5 Amp, 240 Volts complete all as specified and directed.
6S & F Energy efficient LED integrated Batten Type Luminaires suitable for wall or ceiling mounting with built in LED Chip & integral LED Driver 20 watt, Aluminium channel housing & Polycarbornate diffuser of lenghth 1200 mm(approx.), colour temperature 6500K or as directed , Luminaire efficiency not less than 100lm/W with all accessories, fixing arrangement internally pre-wired, making all connection using 1.5 sqmm copper conductor multistrand PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through PVC flexible conduit complete fixed in position & connecting complete all as specified and directed by Engineer-inCharge.
7Supply and fixing LED Flood light watt,120 watt for operting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K),CRI between 80-85, conforming to LM79 and LM 80 standards or as per IS-16104: 2012 and IS-16106: 2012, for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws with IP 65/66 protection, complete all as specified and as directed.
8Supply and Fixing Bracket made out of GI light grade pipe of size 40 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 50mm x 50mm and 04 sets of nuts,bolts and washers painting with two coats of synthetic enamel paint over a red oxide primer complete all as specified and as directed.
9S & F LED Light fitting mirror type with hight out put diffusior 2 feet, 10 watt, 220V AC decorative type with driver holder and LED Lamp including connecting up with three core flexible copper conductor cable of suitable size complete making all connection using 1.5sqmm copper conductor multistrand PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through PVC flexible conduit complete all as specified and directed.
10Supply and fixing Exhaust fan 230/250mm sweep, heavy duty motor with double ball bearing, metallic body, With bird guard to protect the fan in running condition, AC, single phase, 230 Volts, including connection with 1.5 sqmm mutistrand copper conductor flexible wire from ceiling rose, including outside louvers with proper hole, and necessary fixing arrangment and making good to disturbed surface complete all as specified and as directed.
11Supply and fixing Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 6 way with IP-43 IK-09 protection double door complete with appropriate size 200 amps bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good disturbed wall surfaces to match with existing specification complete all as specified and as directed.
12Supply and fixing Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 4 way with IP-43 IK-09 protection double door complete with 200 amps copper bus bar and neutral link, fixed flush in wall including chases cutting in wall for fixing DB and making good disturbed wall surfaces to match with existing specification complete all as specified and as directed.
13Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below normal ground level) connected to and including galvanised styeel earth lead wire 4mm dia by means of bolts, nuts, chock, nuts and washers with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanized earth lead wire by means of bolts, nuts, check nuts and washers of galvanized iron or steel including PCC Pit in 1:2:4 type B-1 angle iron frame with RCC cover and handle, excavation and earthwork in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore upto main Board complete all as shwon in electrical Plate No. 3 of MES Sch 2009 (Part 1) connected to main control board as specified and testing completion complete all as specified and directed. Note :-(i) The unit rate includes GI Pipe upto 7.5m for protection of earth lead. for any additional length the same shall be adjusted through deviation order.(ii) The unit rate includes main earthing lead/strip from electrode to test point upto 7.5m (iii) Incase measured value of earth resistance is recorded more than 1.0 Ohms then the earthing shall be re done by the contractor without any extra cost to the department.
14Total amount of Sch 'A' PART-II (Section-II) (INTERNAL ELECTRIC SUPPLY WORK)
15Total amount of Sch 'A' PART-III (Section-I) (INTERNAL WATER SUPPLY WORK)
16SCHEDULE `A' PART-III (SECTION-II) (INTERNAL WATER SUPPLY WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs. 0.00\\" under Col.5 signifies this fact only.
17S&F C P health Faucets with flexible tube 15mm dia for EWC including all connection complete and all as specified by Engineer-in-Charge.
18Total amount of Sch 'A' PART-III (Section-II) (INTERNAL WATER SUPPLY WORK)
19Total amount of Sch 'A' PART-IV (PLUMBING WORK)
20SCHEDULE `A' PART-IV (SECTION-II) (PLUMBING WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs. 0.00\\" under Col.5 signifies this fact only.
21S & F 110mm PVC (SWR) Bend complete all as specified and as directed.
22S & F 75mm PVC (SWR) Bend complete all as specified and as directed.
23Total amount of Sch 'A' PART-IV (Section-II) (PLUMBING WORK)
24Total amount of Sch 'A' PART-V (HOT WATER SUPPLY WORK)
25Total amount of Sch 'A' PART-VI (CIVIL WORK FOR VIEW CUTTER WORK)
26Total amount of Sch 'A' PART-VII (PATH WORKS)
27Total amount of Sch 'A' PART-VIII (SEC-I) (SEWAGE DISPOSAL WORK)
28Sch 'A' PART-VIII (SEC-II) (SEWAGE DISPOSAL WORK) Note: This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs. 0.00\\" under Col.5 signifies this fact only.
29Onsite LLDPE Septic Tank conventional type designed to carry Sewage and sullage water, exacavation in nay type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 5 Users
30Soakge well exacavation, in any type of soil, foundation in PCC 1:3:6, walls of Honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/SFRC cover, interconnecting pipe of RCC/DWC complete filled with Brick Bats of size 1.2M diaX 1.50M effective depth
31Total amount of Sch 'A' PART-VIII (SEC-II) (SEWAGE DISPOSAL WORK)
32Total amount of Sch 'A' Part-IX (GATE WORK)
33Total amount of Sch 'A' PART-X (Section-I) (EXTERNAL WATER SUPPLY WORK)
34Sch 'A' Part-X (Section-II) (EXTERNAL WATER SUPPLY WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs. 0.00\\" under Col.5 signifies this fact only.
35Material and labour for construction of valve chamber of size 600x 600 x 600 mm deep dimensions (Over all internal dimension) for control valve etc. with PCC foundation, PCC block masonry walls, Plastering, PCC Coping, white washing, mild steel chamber cover, painting to chamber cover including Excavation and earth work in any type of soil complete all as specified below:-Valve chamber shall be provided with the following specifications:-(i) Cement concrete for foundation (1:4:8) type D2 using 40mm graded stone aggregate 150 mm thick extended up to 150 mm beyond the outer face of block masonry.(ii) Walls of valve chamber 200 mm thick with precast cement concrete (1:5:8) (using 20mm graded stone aggregate) solid building blocks , setting in CM 1:6 complete. (iii) Internal and exposed surfaces of valve chamber both concrete and block masonry surface shall be plastered with CM (1:4), 15 mm thick finished even and smooth.(iv) 50 mm thick coping in PCC 1:3:6 type C1 over block masonry wall.(v) Entire plastered surfaces shall be treated with 3 coat of white wash.(vi) Chamber cover shall be of 3 mm thick MS sheet with 40 x 40 x 6 mm size angle iron frame with hold fast and locking arrangement including handle. Steel surface shall be painted with two coats of synthetic paint of first quality over one coat of red oxide primer.
36Material and labour for cutting of water supply mains, GI 80mm dia for alterations or additions and reducing to required length before laying, Screwing existing steel tubing including supply and insertion of new tee of size 80 x 80 x 40mm or as per site requirement, for branch connection complete all as specified and as directed
37Material and labour for cutting of water supply mains, GI 80mm dia for alterations or additions and reducing to required length before laying, Screwing existing steel tubing including supply and insertion of new tee of size 80 x 80 x 25mm or as per site requirement, for branch connection complete all as specified and as directed
38Total amount of Sch 'A' PART-X (Section-II) (EXTERNAL WATER SUPPLY WORK)
39Total amount of Sch 'A' -XI (Section-I) (EXTERNAL ELECTRIFICATION WORK)
40Sch 'A' Part-XI (Section-II) (EXTERNAL ELECTRIFICATION WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs. 0.00\\" under Col.5 signifies this fact only.
41Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level) connected to galvanised Earth Strip 24X4mm as earthing lead by means of bolts, nuts, chuck nuts and washers of GI or Steel all as shown in electrical Plate No 5 including charcoal dust comman salt, 20mm bore GI medium grade watering pipe funnel with wire mesh, including 40mm dia GI pipe light grade for protection of GI Strip including PCC pit 1:2:4 type B-1 using 20mm graded stone aggregates with angle iron 40X40X5mm frame 60mmthick RCC cover with 8mm steel bars 100mm Centre to centre both ways i.e. horizontal and vertical complete all as directed by Engineer-in-Charge and testing for required value complete.Note: If earth resistance of earthing is not found satisfactory it will be done by contractor on his risk and cost.
42Material and labour for Boring of holes not less than 200mm dia under taxi track/road pavement hard standing or in any strata of soil by trenchless technology using ultra sounding latset technique and necessary machinery including provision of HDPE pipe 150mm dia PN 10 up to full length of bore,making good the disturbed surface using PCC work as per site requirement and returning/ refilling of excavated material and removal of surplus soil from site complete all as specified and as directed.
43Supply and fixing LED fllood Light fitting 120 watt, for opearting voltage between 140V to 300V system efficiency not less than 120 lumen / watt,PF-0.95 minimum, IP66 protection, 5700CCT(K),CRI between 80-85,confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012,for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver with over voltage protection,surge protection and other safety test as per IS 15885 Part-2/Sec 13, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing(heat sink) with UV stabilized optics, polycarbonate LENS for symmetrical light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, complete all as specified and as directed
44Supply and fixing hot pressed moulded Glass reinforced polyester sheet moulding compound (SMC) Junction box of dimensions 250mm x 200mm x 100mm, SMC confirming to IS: 13410:1992 Grade S 1 ,thickness of SMC sheet not less than 1.5mm, outdoor type, single door hinged with front side opening, weather proof, suitable locking arrangement at front, arrangement for incoming and out going cable entry at the bottom ,earthing arrangement using One no. of Earthing bolt of MS with 2 nuts and 2 washers provided on RH side of box, Earthing sign has to be provided near to earthing bolt complete all as specified and comprising of the followings items as under:- (a) single phase and neutral bus bar duly colour coded of capacity 100 amps using aluminium strips of size 25mm x 4mm mounted on epoxy resin base insulators, drilled holes for cable connection on bus bar including provision of PVC cable of suitable size and length from bus bar to MCB . (b) MCB SP 5 to 32 Amps, - 01 No (c) Provision of clamp for mounting on pole/wall, clamp made from 20mm x 1.5mm flat iron of suitable shape and length duly fixed with nuts & bolts on the rear side of box
45Supply, installation, testing and commissioning of LT Junction box outdoor type of size 120cm x 75 cm x 45 cm with provision of aluminium busbar three phase and neutral(TPN) with 4 strip each 100 amps capacity and 75 cm long duly colour coded, with 4 pole MCCB as incoming of capacity 100 Amps, 10KA, Ics = 100% Icu, with thermal magnetic release, adjustable overload, 415 volts-01 No. Busbar mounted on epoxy resin base insulators, drilled holes for cable connection on bus bar confirming of IS 8623 Part (one), CPRI approval, totally enclosed vermin proof suitably ventilated for 3 phase, 4 wire 415 Volts, 50Hz, AC supply, outer shell shall be made out of 3.00mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated. Front and back door opening. Protection of enclosure IP 56 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60 cm long using angle iron 40x40x6mm, and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, legs grouted in PCC 1:2:4 and making good distrubed surface complete all as specified and as directed
46M&L for brick laying with subclass 'B' bricks well burnt, laid dry flat in trenches for protection of cable over LT cable, complete all as specified and as directed by the Engineer-In-Charge
47Total amount of Sch 'A' PART-XI (SEC-II) (EXTERNAL ELECTRICAL SUPPLY WORK)
48Total amount of Sch 'A' Part-XII (SITE CLEARANCE, EXCAVATION AND EARTH WORK)
49NOTE: Amount against schedule of credit for retrieved materials mentioned under relevant part of Sch of Credit of tender document in PDF form will be deducted offline/manually from overall amount quoted by the lowest bonafide bidder during award of contract. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56885058
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 10.50 Crore
LAST DATE 10-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn/Addn/Alt Of Perimeter Security Wall With Guard Posts, Guard Rest Room And Security Lights At Certain Locations At Af Stn Awantipur.
Basic Detail
Tender No CEAFU- Token-07 of 2026-27
Bidding Type Tender
Location
City Pulwama
State Jammu and Kashmir
Key Dates
Publish Date 06 Aug 2026
Submission Date 10 Sep 2026
Open Date 17 Sep 2026
Finance
Tender Value 10.50 Crore
Tender Fee 3000
EMD 8.55 Lakhs
Exemption Available
Document List
1MainDrgT072026.rar
1TDsDrgT072026.rar
2MainDrgT022026.rar
2TDsDrgsT072026.rar
35126b5b-2831-48e2-9dc1-2692b63589ca.html
3MainDrgT072026.rar
3TDsDrgsT072026.rar
4TDsDrgsT072026.rar
BOQ_877275.xls
TenderdocT7.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Sep 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
rar

1MainDrgT072026.rar

rar

1TDsDrgT072026.rar

rar

2MainDrgT022026.rar

rar

2TDsDrgsT072026.rar

html

35126b5b-2831-48e2-9dc1-2692b63589ca.html

rar

3MainDrgT072026.rar

rar

3TDsDrgsT072026.rar

rar

4TDsDrgsT072026.rar

xls

BOQ_877275.xls

pdf

TenderdocT7.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders