Housing Urban and Rular Development Government Departments Closing in 5 days TDR #56880254

Tender For flood damage repair / Renovation Of L.I. Scheme At Debtabari Under Budhjungnagar Vc Of Lefunga Rd Block During The Year 2026-27 / Sh:- Replacement Of 1 (One) No. Pump Motor Set, Renovation Of Pump House And Pipe Line In/C Electrical Access

Issued by Government Departments · tripura, Tripura
Tender Value
9.65 Lakhs
Estimated cost
Bid Submission
13 Aug 2026
5 days left
EMD
19306
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for flood damage repair / Renovation Of L.I. Scheme At Debtabari Under Budhjungnagar Vc Of Lefunga Rd Block During The Year 2026-27 / Sh:- Replacement Of 1 (One) No. Pump Motor Set, Renovation Of Pump House And Pipe Line In/C Electrical Accessories And Other Allied Works Within The Jurisdiction Of W.R. Sub-Division Mohanpur. (Job No. Tr/13/Minor Works/Wrd-I/2026-27)

BOQ

Name of Work:- FDR / Renovation of L.I. Scheme at Debtabari under Budhjungnagar VC of Lefunga RD Block during the year 2026-27 / SH:- Replacement of 1 (one) no. Pump Motor set, Renovation of Pump house and pipe line in/c electrical accessories and other allied Works within the Jurisdiction of W.R. Sub-Division Mohanpur. (Job No. TR/13/Minor Works/WRD-I/2026-27)
Sl. No. Item Description
1Dismantling GS sheet roofing including ridges, hips, valleys, gutters wind ties etc. including dismembering and stacking of serviceable materials and unserviceable materials separately with all lifts and upto a lead of 50 m etc.complete as per direction of the Engineer- in-charge.
2Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :i) Of area 3 sqm and below.
3Demolishing brick work including stacking of serviceable materials and disposal of unserviceable materials with all lifts and upto a lead of 50m etc.complete as per direction of the Engineer- in-charge:- i) In cement mortar
4Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level.i) 1 : 2 : 4 ( 1 cement : 2 fine sand : 4 graded well burnt brick aggregate of 20 mm nominal size)
5First class brick work in foundation and plinth including cost of all materials as required complete.I) In Cement mortar 1:4 ( 1 cement : 4 fine sand)
6Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-i) In cement mortar 1:4 ( 1 cement : 4 fine sand )
7Reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete upto plinth level.A) Thermo-Mechanically Treated bars of grade Fe-500D or more
8Centering shuttering including struttings, propping etc. and removal of form work for: i) Suspended floors roofs landings balconies and access plat form with timber plank
9ii) Columns, Pillars, Piers, Abutments, Posts and Struts with wooden plank.
10Reinforced cement concrete work in beams ,suspended floors, roofs having slope upto 15 degree landing balconoes shelves chajja lintels bands plain windows sills , staircase upto floor five level excluding cost centering , shurttering, finishing and reinforcement.i) 1:2:4(1 cement:2 fine sand:4 gradded well burnt aggt.20 mm nominal size)
11Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, & with cleats with bolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required:-i) Using flates 30 x6mm for diagonal braces and central cross piece.
12Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.i) Fixed to steel windows by welding.
13Providing and laying cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips etc.complete.i) 40 mm thick with 20 mm well burnt brick aggregate
14Steel work in built up tubular( round , square or ractangular hollow tubes etc) trusses etc. includng cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, in/c welding and bolted with special shaped washers etc.complete i) Hot finished welded type tubes
15Providing and fixing M.S. round holding down bolts with nuts and washer complete as per standard design.
16Providing & fixing MS nuts & bolts. Including washers complete as per standerd design;-(a) Upto 300 mm length
17Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
18Charges for fixing corrugated G.S. Sheet roofing fixed with polymer coated J or L hooks 8 mm diameter, bolts and nuts 6 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with lead and including a coat of approved steel primer and two coats of approved epoxy paint on overlapping of sheets complete ( upto a pitch of 60 degrees ) over a built structure including all types of necessary scaffoldings etc. but excluding the cost of the C.G.S. sheets, purlins, rafters and trusses etc.as per clauses of Chapter - 12 of CPWD specification. a) 0.63 mm thick with zinc coating not less than 275 gm / m2
19Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.i) 0.63 mm thick with zinc coating not less than 275 gm / m2
20Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.i) 0.63 mm thick with zinc coating not less than 275gm/m2
21Providing and Installation of Horizontal pump motor set (Centrifugal) with allied equipments by maintaining proper level / slope , alignment etc. in/c all necessary nuts & bolts, washers etc. at site of work and making necessary electrical connection with main switch / starter with motor in/c commissioning & trial run for 10 hrs. in two spell as per direction of the Engineer-in-charge.i) 25 HP motar with 60 LPS 22 m head pump
2212 mm cement plaster of mixi) In Cement mortar 1:4 ( 1 cement : 4 fine sand )
23Neat cement punning .
24Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:i) Two or more coats on new work
25Painting on G.S. sheet with synthetic enamel paint ( two or more coats ) of approved brand and manufacture of required colour to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : i) New work (two or more coats) including a coat of appropriate steel primer but excluding a coat of mordant solution
26Providing and fitting fixing of 6 feet x 4 feet x 1 inch (thickness) Gamair wood / plywood pannel board for fitting fixing of electrical items, in/c 2 nos MS angle post ( size 2 inch x 2 inch x 9 feet ), nuts & bolts etc. for irrection of the same by 1:1.5:3 cement concrete casting ( 1 feet x 1 feet x 2 feet) below the ground level and painting two or more coats & plastic paint as per specification and direction of the Engineerin-charge.
27Providing & fitting fixing Steel sheet enclosed switch Fuse unit (Suitable for DIN fuse) triple pole with Neutral Link (TPN) , 415/500 Volt,L&T/ Havells/BCH make etc complete as per Specification direction of Engineer-in-Charge.i) Current range 63 Amps.
28ii) Current range 200 Amps
29Providing & fitting fixing of Fully Automatic Star Delta type Motor startar ( 3ph, 50 Hz, 415V in steel sheet enclosure with Conductors and Timer etc. complete suitable for motor pump L&T, BCH,ABB make as per Specification direction of Engineer-in-Charge.i) 25HP/18.5 kw Relay range within 13-21 +10%
30Supplying & fitting fixing of PVC insulated Copper Wire with all electrical equipments including trial run etc. complete (ISI Marked) on the pannel board of approved quality.i) 7/16 Copper Wire
31Supplying and fitting fixing power capacitor (ISI Marked) of approved quality.i) 12.5 KVAr
32Providing and fitting fixing 3 phase indicating lamp fiited with panel board with three different colour lamps with batten holder complete as per specification and direction of the Engineer-in-charge.
33Providing & fixing 200 Amps busber of size 600 x450x100 mm with 4 nos. copper strips of size 450x40x4 mm of approved quality
34Providing and fixing G.I. pipes of medim class as per IS : 1239 with latest amendment complete with G.I.fittings including trenching and refilling etc. complete as per CPWD specification and direction of the Engineer - in - charge.External worki) 40 mm dia. nominal bore
35Providing and fixing C.I. non-return valve of approved quality as per CPWD specification and direction of the Engineer - in -chargei) 125 mm nominal bore
36Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.i) 150 mm dia. A. PN - 1.6
37ii) 125 mm dia. A. PN - 1.6
38Providing & fixing of GI . Bend , elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the EIC. i) 125 mm dia
39ii) 150 mm dia
40Providing & fitting fixing of MS flange ( 8 mm wall thickness ) by welding with G.I. / MS pipe and placing position as per specification and the direction of the Engineer-in-charge.i) 150 mm dia
41ii) 125 mm dia
42Providing & fitting fixing rubber flange washer 6mm thick at site of work of approved quality.i) 125 mm dia.
43ii) 150 mm dia.
44Providing and fitting fixing of moving iron type Range 0-500 V. 96 x 96 mm size AC volt meter (L & T/ AE make ) with selector switch as a electrical instrument of the panel board as per specification and direction of the Eng-in-charge.
45Providing and fitting fixing of moving iron type Range 0- 100/0-200 amps. 96 x 96 mm size AC amps meter (L & T/ AE make ) with selector switch as CT coil as a electrical instrument of the panel board as per specification and direction of the Eng-in-charge.
46Supplying & fitting fixing of C.I. tail piece of approved quality at site of work. i) 150 mmdia
47ii) 125 mm dia
48Providing and fitting fixing PVC suction hose pipes of wall thickness 6 mm. as per relevant IS specification and direction of Engineer-in-charge.i) 150 mm dia
49Providing and fitting fixing MS Foot valve as per relevant IS specification and the direction of the Engineer-in-charge.a) 150 mm dia
50Providing & fitting fixing MS hose clamp with nuts & bolts etc.complete as per relevant IS specification and direction of Engineer-in-charge.a) 150mm dia
51Excavating trenches of required width for pipes, cables, etc. including excavation for sockets and dressing of sides ramming of bottoms , depth minimum 1.25m including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming watering etc. and disposal of surplus excavate dsoil as directed within a lead of 50 m as per CPWD Specification & direction of Engineer-in-charge.A) All kinds of soil.a) For pipe not exceeding 90mm dia .
52b) For pipe exceeding 90 mm dia but not exceeding 300 mm dia .
53B) For G.I. / C.I. / D.I. pipes in new worka) For pipes exceeding 90 mm dia but not exceeding 300 mm dia
54Providing and laying different dia rigid UPVC pipes of Working Pressure 4.0 kg/ sq.cm. complete with necessary coupler and solvent cement as per CPWD Specification & direction of Engineer-in-charge.i) 90 mm dia
55ii) 110 mm dia
56iii) 140 mm dia
57iv) 160 mm dia
58v) 200 mm dia
59Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc.complete as per CPWD specification and direction of the Engineer - in - charge.a)External work.i) 150 mm dia. nominal bore
60ii) 125 mm dia.nominal bore
61Providing and fitting fixing of G.I hydrant suitable for PVC pipes asper standard specification complete as per direction of Engineer-incharge (Rate excluding the cost of NTP control valve).80X50 mm dia.
62Providing and fitting fixing of different dia rigid UPVC unequal Tee (including earth cutting & backfilling all socketted) suitable for pipes as per IS specification of working pressure 4.0 kg/sq.cm confirming to IS: 10124 (part-V) as per CPWD Specification & direction of Engineer-in-chargei) 160x160x140 mm dia
63ii) 160x160x110 mm dia
64iii) 160x160x90 mm dia
65iv) 140x140x110 mm dia
66v) 140x140x90 mm dia
67vi) 110x110x90 mm dia
68Labour charge for repairing of leakage in existing UPVC distribution system including required earth cutting and fitting fixing of necessary coupler etc. complete and refilling the trench with available excavated earth as per direction of the Engineer-in-charge. (Payment of couplers, tees, reducers etc will be made separately)i) 250 mm dia to 110 mm dia.
69ii) 90 mm dia.
70Providing, fixing and laying fabricated UPVC socket / coupler conforming to IS : 10124 ( Part 2 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in -charge.i) 90 mm dia.
71ii) 110 mm dia.
72iii) 140 mm dia.
73iv) 160 mm dia.
74Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 ( Part 3 ) with solvent cement conforming to IS : 14182 including testing of joints completeas per CPWD specification and direction of the Engineer - in -charge.i) 160 x140 mm dia
75ii) 140 x110 mm dia
76iii) 110 x90 mm dia Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56880254
AUTHORITY Government Departments
TENDER VALUE 9.65 Lakhs
LAST DATE 13-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for flood damage repair / Renovation Of L.I. Scheme At Debtabari Under Budhjungnagar Vc Of Lefunga Rd Block During The Year 2026-27 / Sh:- Replacement Of 1 (One) No. Pump Motor Set, Renovation Of Pump House And Pipe Line In/C Electrical Accessories And Other Allied Works Within The Jurisdiction Of W.R. Sub-Division Mohanpur. (Job No. Tr/13/Minor Works/Wrd-I/2026-27)
Basic Detail
Tender No 24_EE_WRD_I_DNIET_2026_27
Bidding Type Tender
Location
City tripura
State Tripura
Key Dates
Publish Date 06 Aug 2026
Submission Date 13 Aug 2026
Open Date 14 Aug 2026
Finance
Tender Value 9.65 Lakhs
Tender Fee 1000
EMD 19306
Exemption Not Available
Document List
BOQ_76771.xls
DNIeT_24_EE_2026-27.pdf
f3cda076-4c14-4fe6-98c4-0fae1655f693.html
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Aug 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_76771.xls

pdf

DNIeT_24_EE_2026-27.pdf

html

f3cda076-4c14-4fe6-98c4-0fae1655f693.html

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders