Housing Urban and Rular Development Government Departments Closing in 5 days TDR #56880228

Tender For Annual Maintenance Contract Of Electrical Installation In All The Buildings Of Modern Psychiatric Hospital, Narsingarh, Tripura(W) For The Year 2026-27.

Issued by Government Departments · tripura, Tripura
Tender Value
5.47 Lakhs
Estimated cost
Bid Submission
13 Aug 2026
5 days left
EMD
10953
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Annual Maintenance Contract Of Electrical Installation In All The Buildings Of Modern Psychiatric Hospital, Narsingarh, Tripura(W) For The Year 2026-27.

BOQ

Name of Work:- Annual maintenance Contract of electrical installation in all the buildings of Modern Psychiatric Hospital, Narsingarh, Tripura(W) for the year 2026-27.
Sl. No. Item Description
1Providing and fixing of 3 pin 5/6 amps plug point with piano type 5/6 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on switch board, earthing the 3rd pin etc. as required:-
2Providing and fixing of 3/6 pin15/16 amps plug point with piano type 15/16 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) on switch board, earthing the 3rd pin etc. as required:-
3Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with PVC switch board and fancy type switch with cover plate including connection etc as required:-
4Short Point :-
5Medium Point :-
6Long Point :-
7Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-
8Short Point :-
9Medium Point :-
10Long Point :-
11Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
12Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
13Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.
142 X 1.5 sq mm
152 X 2.5 sq mm
162 X 4 sq mm
174 X 4 sq mm
184 X 6 sq mm
19Supplying and fixing of the following electrical accessories including necessary connection etc. as required.
205/6 amps piano type switch
215/6 amps fancy type switch with cover plate
2216/20 amps piano type switch
235/6 amps piano type call bell push
243 pin 5/6 amps piano type socket
253/6 pin 16/20 amps piano type socket
26Electronic 4 step mini fan regulator
27Pandent holder
28Angle/batten holder
29Buzzer Call bell
30Ding dong call bell
31Musical call bell
32Remote controlled call bell
332.5 mfd fan capacitor
343mm thick bakelite sheet
355 amps power top:-
3615 amps power top:-
3732 amps DP kit kat switch:-
38Supplying and fixing of the following sizes PVC switch boards with cover etc. as required.
3975mm x 75mm (3\\" X 3\\") :-
40102mm x 102mm (4\\" X 4\\")
41102mm x 178mm (4\\" X 7\\") :-
42152mm x 203mm (6\\" X 8\\") :-
43203mm x 254mm (8\\" X 10\\") :-
44Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required.
451-2 module plastic switch board:-
463 module plastic switch board:-
474 module plastic switch board:-
486 module plastic switch board:-
498 module plastic switch board:-
5012 module plastic switch board:-
51Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required.
521-2 module :-
533 module :-
544 module :-
556 module :-
568 module :-
5712 module :-
58Supplying and fixing of the following modular accessories including necessary connection etc. as required.
596/10 amps one way SP switch (1M) :-
606/10 amps two way SP switch (1M) :-
6116/20 amps one way SP switch (1M) :-
623 pin 6/10 amps socket outlet (2M):-
633/6 pin 16/20 amps socket outlet (2M):-
644 step fan regulator (1M):-
6520/25 amps single phase motor starter switch (2M):-
66Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required.
67Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copper wire on surface or in existing G.I / PVC / Polythene pipe for loop earthing as required.
68Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals.
69Supply and fixing of 25mm x 3mm Copper on walls/ floor of the building for horizontal/ vertical network including necessary spacers and porcelain insulators at regular intervals.
70Supply and fixing of the following sizes GI prong with necessary nuts & bolts etc as required grouted on roof for Lightning protection.
71Copper. Prong 450 mm long
72Copper. Prong 1000 mm long
73Providing earthing system with maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminal size 32mmx 6mm including accessories with masonry enclosure of CI cover plate size 12\\"x 12\\" having locking arrangement including CC works etc as required:-
74Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : -
75Supplying & installation of 400 mm sweep AC padestal fan with metal blade including connection etc as required:-
76Supplying & installation of 450 mm sweep wall mounting air circulator including connection etc as required:-
77Supplying & installation of 450 mm sweep AC padestal air circulator including connection etc as required:-
78Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:-
79Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required:-
80Supplying & installation of 300 mm sweep 900 rpm metalic body exhaust fan including connection etc as required (ISI marked) :-
81Supplying & installation of 380 mm sweep 900 rpm metalic body exhaust fan including connection etc as required (ISI marked) :-
82Supplying & installation of 450 mm sweep 1400 rpm metalic body exhaust fan including connection etc as required (ISI marked) :-
83Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-
84Supplying & installation of shutter for 380/450 mm sweep metalic body exhaust fan in the existing hole as required:-
85Supplying of 400 mm sweep AC padestal fan with metal blade etc as required:-
86Supplying of 400 mm sweep AC wall mounting fan with metal blade etc as required:-
87Dismantling the existing ceiling fan and making winding by (34/35/36 S.W.G) Copper wire, varnish, oiling, greasing and re-fixing the same including wiring the down rod of standard length (up to 30 cm) etc. as required :-
88Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required:
89Supplying and fixing of following room heater complete with 15 amps top including necessary connection etc as required.
901000 watt fixed type room heater:-
911000/1500/2000/2500 watt blower type room heater:-
92Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-
93Surface mounted integrated 20 watt LED batten with polycarbonate diffuser:-
94Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):-
95Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:-
96Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-
9760 watt LED flood light fixture with integral driver and secondary lens (IP 66):-
9880 watt LED flood light fixture with integral driver and secondary lens (IP 66):-
99Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-
10018/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):-
1019 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :-
102Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.
1034 way horizontal TPN MCB DB (Double door):-
1046 way horizontal TPN MCB DB (Double door):-
1058 way horizontal TPN MCB DB (Double door):-
10612 way horizontal TPN MCB DB (Double door):-
1074 way vertical TPN MCB DB suitable for FP MCB incomer (Double door):-
1084 way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 amps (Double door):-
1096 way vertical TPN MCB DB suitable for FP MCB incomer (Double door):-
110Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:-
1116 to 32 amps SP MCB:-
1126 to 32 amps DP MCB:-
1136 to 32 amps TP MCB:-
1146 to 32 amps TPN MCB:-
1156 to 32 amps FP MCB:-
11640 amps DP MCB:-
11740/50/63 amps TP MCB:-
11840/50/63 amps TPN MCB:-
11940/50/63 amps FP MCB:-
120Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):-
121125 amps FP MCCB, Breaking capacity 25KA (Thermal Magnetic) :-
122Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required
1232 core 4 Sq mm
1243.5 core 35 Sq mm
125Supplying and laying of following sizes XLPE insulated PVC sheathed copper conductor Un-armoured cable including necessary connection etc as required.
1263 core 1.5 Sq mm
1274 core 2.5 Sq mm
128Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes : -
1294/6 sq mm
13010 sq mm
13116 sq mm
132Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: -
1332.5 sq mm
1344 sq mm
1356 sq mm
13610 sq mm
13716 sq mm
13825 sq mm
13935 sq mm
140Supplying and fixing of 20 mm MS pipe as down rod for installation of luminaries with necessary accessories etc as required.
141Supplying & fixing of 40 mm dia G.I pipe (medium gauge) cross bar for fixing of ceiling fan/luminaries including painting & necessary accessories etc as required.
142Drawing of armoured/un-armoured cable with proper saddling etc as required:-
143Supplying & installation of Digital timer Switch including necessary connection etc as required:-
144Supplying & installation of Astronomical timer Switch including necessary connection etc as required:-
145Cleaning of existing ceiling fan/luminaries.
146Hiring of Skilled Electrician/Semi-Skilled Electrician for maintenance of Electrical distribution box, panel, maintenance of earth pit and other patty maintenance work, cleaning of electical accessories related to internal electification work.
14701 (One) Skilled Electrician from 9.00 AM to 5.00 PM for supervision and testing of whole system i.e
14801 (One) Semi-Skilled Electrician from 9.00 AM to 5.00 PM for supervision and testing of whole system i.e Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56880228
AUTHORITY Government Departments
TENDER VALUE 5.47 Lakhs
LAST DATE 13-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Annual Maintenance Contract Of Electrical Installation In All The Buildings Of Modern Psychiatric Hospital, Narsingarh, Tripura(W) For The Year 2026-27.
Basic Detail
Tender No EE_IED_AGT_65_2026_27
Bidding Type Tender
Location
City tripura
State Tripura
Key Dates
Publish Date 06 Aug 2026
Submission Date 13 Aug 2026
Open Date 13 Aug 2026
Finance
Tender Value 5.47 Lakhs
Tender Fee 1000
EMD 10953
Exemption Not Available
Document List
173070d8-4029-4d33-852a-8440b07b1f9f.html
BOQ_76816.xls
DNIeT65.pdf
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Aug 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

173070d8-4029-4d33-852a-8440b07b1f9f.html

xls

BOQ_76816.xls

pdf

DNIeT65.pdf

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders