Tender For Certain Electromechanical (E/M) And Buildings And Roads Repair Works To Building At Wsa Bdps At Af Stn Utarlai
Tender Value
30 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
5 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Barmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Certain Electromechanical (E/M) And Buildings And Roads Repair Works To Building At Wsa Bdps At Af Stn Utarlai
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing the demolished material to a distance upto 500m and depositing where directed, complete all as directed by Engr-in-Charge. |
| 2 | M&L for 100 mm thick PCC 1:4:8 type D-2 using 40mm stone aggregate as in sub base floor/floors and paving etc. |
| 3 | S&F rubber moulded Machine pressed PCC interlocking paver block confirming to IS 15658-2006 of size 80 mm thickness M-40 Grade with grey cement and pigment laid dry over 25mm thick screed river washed sand cushion as in floor, shape and colour as directed by Engr in charge. |
| 4 | M&L for Pre-cast cement concrete Type B1 1:2:4 (20 mm graded aggregate) kerb solid blocks, exc. 10 cm in width and setting in cement mortar 1:4, complete all as specified |
| 5 | M&L for 100 mm thick plain cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in flooring complete all as specified and directed. |
| 6 | M&L for treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed. |
| 7 | Surface dressing n exc 15 cm deep in soft/loose soil on top surface of filled up each of traverse of blast pens complete all as specified and directed. |
| 8 | Supply and stacking of approved soil/earth out side defence land and deposited at blast pen or any other places in tech area (The soil shall be used for filling against item ser no. ) complete all as directed |
| 9 | Levelling of top surface of blast pens /traverse wall by using approved soil in layers n exc 30 cm thick watering ramming and finishing to required size shape etc . The levelling work shall be carried out from base of the blaste pen up to top height varying from 0.00 mtr to 10.00 mtr |
| 10 | M&L for preparation of old steel surfaces of any description exceeding 10cm in width or girth and applying two coats of fire resisting paint complete all as specified and directed. |
| 11 | Taking down any type of copper/aluminium flame proof point wiring (light, fan) complete, including fixture and fittings such as rotary switches, steel conduit etc. complete including making good the disturbed surfaces of walls, ceilings complete all as specified and as directed. |
| 12 | M&L Point wiring for flame proof light point controlled by one switch with 1100 volts grade 1.5 sqmm PVC insulated unsheathed FRLSH multistranded copper conductor cable as per IE colour code for phase /neutral /earthing wire drawn into and including rigid in stove enamelled mild steel ERW conduit medium grade minimum 20mm dia and accessories concealed in walls/roof/floors with continuous 1.5 sqmm PVC insulated unsheathed FRLSH multistranded copper conductor cable as earth continuity conductor and connecting to common earth dolly complete including cutting chases in brick/ block/stone masonry wall , replastering and making good to match the existing specifications complete all as directed. |
| 13 | S&F in replacement for flame proof wiring with 2 runs of 4.0 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade drawn through and included ERW mild steel conduit of minimum 20mm dia external (which shall be increased as per actual site requirement in Accordance of clause No 19.125.07 SSR part -I) with all conduit accessories like bends,juction boxes etc and FRLSH PVC insulated unsheathed copper conductor wire of 4.0 Sqmm as a continous earth wire fixed on wall surface /ceiling . Note : 2 runs of 4.0 sqmm FRLSH PVC insulated unsheathed copper conductor and 1 run of 4.0 sqmm FRLS PVC insulated unsheathed copper conductor and 1 run of Steel conduit of size 20 mm will be measured as single run. |
| 14 | Supply and fix in replacement of FLP/WP switch 16 Amp, 250V single pole ON/OFF rotary type with termination box in LM6 all as specified and directed by Engr-in-Charge. |
| 15 | Supply and fix in replacement of FLP/WP switch 16 Amp, 250V double pole ON/OFF rotary type with termination box in LM6 all as specified and directed by Engr-in-Charge. |
| 16 | Supply and fix in replacement of FLP/WP switch 25 Amp, 250V double pole ON/OFF rotary type with termination box in LM6 all as specified and directed by Engr-in-Charge. |
| 17 | Supply and fix in replacement of flameproof DB 4 way, TPN, Incommer MCB TPN 63A -01 No, Outgoing MCB 6 A-12 Nos as per existing all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 18 | Supply and fix in replacement of flameproof DB 4 way, TPN, Incommer MCB TPN 63A -01 No, Outgoing MCB 6 A-12 Nos as per existing all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender