Tender For Special Repair Of Bldg No T-207 (Chdh) Of 472 Fd Hosp At Nurla Mil Stn Under Age (I) Nimu
Tender Value
9.32 Lakhs
Estimated cost
Bid Submission
25 Aug 2026
2 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Leh → Ladakh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair Of Bldg No T-207 (Chdh) Of 472 Fd Hosp At Nurla Mil Stn Under Age (I) Nimu
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness (belowor above ground level) complete all as specified and directed by Engr-in charge. |
| 2 | M&L for 75mm thick Cement concrete type D- 2,1:4:8 (40mm graded aggregate) as in sub base of floor complete all as specified and directed by Engr-in charge. |
| 3 | Dismantling floor, hearth or wall tilling including cement mortar bedding ( but not backing ) removing serviceable tiles to store and rubbish of the premises complete all as specified and directed by Engr-in charge. |
| 4 | M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. over 15mm thick Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in charge. |
| 5 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in charge. |
| 6 | S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engr-in charge. |
| 7 | M&L painting on steel surface over 10 cm width or girth including preparation of surface and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in charge. |
| 8 | Dismantling timber scantling 40 sqcm and over in section, in any position in framed work in scantling etc complete all as specified and directed by Engr-in-charge. |
| 9 | M&L second class Hard wood in clean sawn timber fixed and fixed in scantlings complete all as specified and directed by Engr-in-charge. |
| 10 | Dismantling wall and ceiling boards(fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness including cover fillets complete all as specified and directed by Engr-in charge. |
| 11 | S&F 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work as in Ceiling complete all as specified and directed by Engr-in charge. |
| 12 | S&F 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails to timber frame work as in walls complete all as specified and directed by Engr-in charge. |
| 13 | Dismantling timber scantling as in fillets, rails, posts, rafters, purlinf, etc under 40 sq.cm in section in any position as in unframed work complete all as specified and directed by Engr-in charge. |
| 14 | M&L for 2nd class soft wood of sectional area exc 13 & n.exc 25 sq.cm in plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads complete all as specified and directed by Engr-in charge. |
| 15 | Demolition of Stone slabs and tiles of any description laid, bedded and pointed in in any mortar or thickness in floors, aprons etc complete all as specified and directed by Engr-in charge. |
| 16 | M&L for 20mm thick Granite (of any type) tiles machine cut, bedded including Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying finishes and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed by Engr-in charge. |
| 17 | S&F in repair Stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc.overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engr-in charge. |
| 18 | S&F in repair 15mm bore Bib Tap Chromium plated fancy type complete all as specified and directed by Engr-in charge. |
| 19 | Taking up/down 15mm bore old tubing on walls and connection of size 15mm bore complete all as specified and as directed complete all as specified and directed by Engr-in charge. |
| 20 | S&F for 25mm outer dia 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed by Engr-in charge. |
| 21 | Dismantling broken water tank of cap exc 500 ltr but n exc 1000 ltr complete all as specified and directed by Engr-in charge. |
| 22 | S&F for 1000 ltr cap Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engr-in charge. |
| 23 | S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or floor of 75mm bore pipe complete all as specified and directed by Engr-in-charge |
| 24 | S & F PVC (SWR) floor trap of 75mm plain with grating including jointing with solvent cement complete all as specified and directed by Engr-in charge. |
| 25 | M&L for 100mm thick cement concrete 1:3:6 type C2 bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; complete all as specified and directed by Engr-in charge. |
| 26 | S&F BALL VALVE 25mm dia complete all as specified and directed by Engr-in charge. |
| 27 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of internal dia 75-100mm incl any earth work and demolition of PCC complete all as specified and directed by Engr-in charge. |
| 28 | Taking down carefully aluminium/Copper point wiring light, fan socket or power complete fitting such as switches, ceiling rose, fan regulator, socket including light fitting etc complete with /PVC /MS conduit and T/W battern / casing caping and all as specified and as directed by Engineer-in-Charge. |
| 29 | Taking out old unsv underground cable of any size/make/ type etc from excavted tranches/ on pole passing through pipes etc from different locations complete all as specified and directed by the engr in charge. |
| 30 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core 16 sq. mm nominal cross section in all as directed by Engineer-in-Charge |
| 31 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-(a) One light point/one fan point controlled by one switch |
| 32 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-(b) One 3 pin 5 amps socket outlet independent with cables 2.5 sqmm size |
| 33 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for following :-(c) One 3 pin 5 Amp socket outlet on same board. |
| 34 | All same as per item No 32 above but with conductor of size 4 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 4 sqmm PVC insulated stranded copper conductor Cable complete all as specified and directed by the engr in charge. |
| 35 | S&F Socket 2 in 1, 5 pin 5 Amp flush type complete all as specified and directed by Engr In Charge. |
| 36 | S&F Switch piano flush type 5 Amp, single pole, one way complete all as specified and directed by Engr in Charge. |
| 37 | S&f Switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed by Engr in Charge . |
| 38 | S&F Switch Socket Combination 2 in 1, 3 pin, 15/16 amp flush type Universal complete all as specified and directed by Engr in Charge . |
| 39 | M&L for ceiling rose surface Bakelite 65x50mm two to three terminal complete all as specified and as directed by Engr-in-Charge. |
| 40 | S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and directed by Engr in Charge. |
| 41 | S&F basic all purpose surface and wall mounted LED batten with polycarbonate housing and integreted electronic driver of cap 10 watt, 2 feet long, with all accessories complete all as per specified and as directed by Engr-in-Charge.(Havells Cat Pt No. - LHEXACP7IN1W010 or equivalent in Philips/Crompton) |
| 42 | S&F basic all purpose surface and wall mounted LED batten with polycarbonate housing and integreted electronic driver of cap 20 watt, 4 feet long, with all accessories complete all as per specified and as directed by Engr-in-Charge.(Havells Cat Pt No. - LHEXAXPNIN1W020 or equivalent in Philips/Crompton) |
| 43 | S&F Decorative wall mounting with matt gold finish with soda glass suitable for 9 W G9 LED Lamp with G9 base basic all purpose light with polycarbonate housing and integreted electronic driver of , with all accessories complete all as per specified and as directed by Engr-in-Charge.(Havells Cat Pt No. - LEFOAJE1TN1I060) |
| 44 | S&F in repair sheet metal powder coated versatile Double door SPN distribution board, 12 way suitable for MCB's fitted with copper bus bar rated 200amps, neutral link , earth bar and din rail suitable for use on 240 Volt, 50Hz all as directed by Engr in Charge. |
| 45 | M&L in repair for MCB SPN 63 Amp, 240V with 10KA breaking capacity of 'C' series in distribution boards complete all as specified and directed by the engr in charge. |
| 46 | S&F in repair to MCB SP 6-32 Amp with 10KA breaking capacity of 'C' series in distribution boards with all accessories complete all as per specified and as directed by Engr-in-Charge. |
| 47 | Dismantling and Taking down old u/s street / building sequrity Light fittings from poles, flood lights, post top lantern lights and garden lights for replacement with LED fittings all as specified and as directed by Engr in Charge. |
| 48 | Supply and fix LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete Specified and directed by Engr in charge. |
| 49 | M&L for GI bracket 1.5 mtr long made out of GI pipe 40mm dia bend to suitable radius incl clamps nuts bolts washers incl painting with aluminum paint etc complete all as specified and directed by Engr in charge. |
| 50 | Supply and fix in repair electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessoriessuch as safety valve, thermostate,NRV, connection piece etc. complete Specified and directed by Engr in charge. |
| 51 | Supply and fix in repair exhaust fan made of steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and complete with louvers shutter, voltage 230V, 50 Hz RPM 1200, Copper winding of sweep 300 mm sweep with, blades, and frame and louvers all as per specified and as directed by Engr-in-Charge. |
| 52 | S & F in repair Air termination, single pointed, copper rod 12mm dia and 300mm long different locations / Bldg complete all as specified and directed by the engr in charge. |
| 53 | S & F in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by the engr in charge. |
| 54 | S&F in repair Galvanised earth lead wire 4.0mm dia for roof conductors and down conductors above ground complete all as specified and directed by the engr in charge. |
| 55 | Supply and fix in repair or laying 32 mm light grade GI Tubes in trenches/on wall/ poles/ structures as in repairs GI tubeing light grade for road crossing/ for cable protection / fixing of pigmi lights etc, of the folling size including necessary provision for cable / Strip entry if reqd in pigmi lights pole fixinf screws / clmp complete as required complete all as specified and directed by Engr in Charge. |
| 56 | M & L for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to MS galvanised earth lead wire 4.0mm dia by means of bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, GI strip laid in dia 40 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit (30X30X30cm) with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysAug 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender