Tender For Special Repair To Bldg No P-132 To 137 At 17 Jak Rif Under Ge (West) Delhi Cantt-10.
Tender Value
48.57 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
11 days left
EMD
97140
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Bldg No P-132 To 137 At 17 Jak Rif Under Ge (West) Delhi Cantt-10.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-Aug-2026 | Revised BOQ | BOQ | 27-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) n. exc 1.5 sq. m each complete all as spd & directed. |
| 2 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as spd & directed. |
| 3 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as spd & directed. |
| 4 | Dismantling Brick tiles or terracing tiles, single layer on roofs including thatching any type, mud phuska etc including cleaning the surface by water/air pressure and removal of debrish beyond MOD land complete all as specified and directed. |
| 5 | M&L for powder coated Anodised aluminium frame for doors, windows, ventilators, grill, partitions, sliding tracks, aluminium section for shutters suitable for two/three/four track window and aluminium section sliding members incl all necessary fittings and fixtures, jointing cleats, rubber packing etc complete all as specified and directed. |
| 6 | S&F powder coated aluminium window and ventilator shutters, side hung type with/ without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21, 100mm long (2 Nos) suitable handle (1 No) complete all as specified and directed. |
| 7 | S&F 5.5 mm thick Sheet glass, selected quality and fixed to aluminium joinery in square n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 8 | Supply and fixing plain ACP Board 5 mm thick, fixed in aluminium joinery/partitions including cutting, packing, finishing complete all as specified and directed. |
| 9 | M&L for 75mm thick PCC 1:3:6 type C-2 (40mm graded agg) for plinth protection laid in bays and finished even and fair incl filling the joint with bitumen mastic including demolition of plinth protection complete all as specified and directed . |
| 10 | M&L for machine cut kota stone slab 20-25mm thick as in riser of stpes, skirting, dado and pillar, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing surface and including 15 mm thick screed bedding layer in CM 1:6 complete all as spd & directed. |
| 11 | M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping, bed plates, kerbs including weathering slightly rounded or chamfered and throating complete all as specified and directed. |
| 12 | M&L for brick work in cement mortar 1:6 using sub class B bricks, straight or curved on plan exc 6mtr mean radius complete all as specified and directed. |
| 13 | M&L for Ready Mix plaster 15mm thick on brick or concrete surface of internal and external walls finished even and fair surface without using extra cement complete all as specified and as directed. |
| 14 | M & L Rendering 5mm thick in ready mix on ceiling to be finished even and fair (without using extra lime or cement) as in patch works or whole work complete all as specified and directed.. |
| 15 | M&L for preparation of old treated brick surfaces of walls upto by scrubbing with wire brush, hard brush, washing down with water and applying two coats of cement paint, white or tinted over one coat of alkali resistant primer complete all as spd & directed. |
| 16 | M&L preparation old plastered surfaces of ceiling and applying two coats of white wash all as specified and directed. |
| 17 | M & L preparation of new surfaces plastered of wall two coats of distempering walls with distemper oil emulsion, white or tinted over a coat of primer complete all as specified and directed. |
| 18 | M&L for Preparation of newly plastered surfaces of walls and applying two coats of cement based paint white or tinted ,complete all as specified. |
| 19 | M&L preparation of newly plastered surfaces and applying two coat of white wash on ceiling surface complete all as specified and as directed. |
| 20 | M&L for preparing old treated surface of wall and applying two coats of oil bound distemper all as specified and directed. |
| 21 | M&L for brushing neat cement slurry with 3.0 Kg of cement per sqm complete all as specified and directed |
| 22 | M&L for cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in roof padding/kerb, mud slopes, rounded or chamfered edge complete all as specified and directed |
| 23 | M&L for rendering 10mm thick cement mortar 1:4 on fair face of brick work or concrete surface complete all as specified and directed. |
| 24 | M&L for water proofing treatment to roof surface with APP water proofing membrane 3mm thick & weighing not less than 3.0 kg/sqm of approved make black finish & reinforced with non woven polyester matt of min 150 gm/sqm laid over a coat of bitumen primer conforming to IS-3384 @ 0.4 Ltr/sqm over prepared roof surfaces, forcing overlap with a propane or a butane gas torch with a overlap of 100mm at sides & 100mm at ends & sealing as per manufacturer's instructions including two coat (i.e 0.2 ltr/Sqm) of aluminium paint entire treated surface.Note :- 1. Water proofing treatment shall be got carried out by the manufacturer or their authorised applicator only. 2. Bitumen primer, bitumen and membrane shall be of same make/manufacturer. |
| 25 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr depth for fdn etc for soft manhole not exc 10 sqm on plan and getting out any type of soil complete all as specified & directed. |
| 26 | Returning filling in soft/loose soil incl spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified & directed. |
| 27 | Removing of surplus soil to exc 250 mtr but n.exc 500 mtr and deposited where directed as a level n.exc 1.5 mtr above the starting point complete all as specified & directed. |
| 28 | M&L for cement concrete 1:3:6 type C-2 using 40mm graded agg incl packing under and haunching against sides of 150mm dia (Internal dia) pipe after they are laid and tested complete all as specified (Thickness of concrete bed 150mm) complete all as specified & directed. |
| 29 | M&L for Reinforced concrete pipe class NP2, 450mm dia laid in trenches & jointed in cement mortar (1:2) with collars complete all as specified and directed. |
| 30 | M&L for 75mm thick SFRC manhole/drain cover size not exc 1.00sqm each set and jonted in cement mortar 1:4 complete all as specified & directed. |
| 31 | M&L for RCC M25 design mix, using 20mm graded stone aggregate in basement slabs, hardstanding floors including mixing of metallic floor hardener, ramps and mass concrete complete all as specified and directed. (Note: Metallic hardener qty will be paid separately ) |
| 32 | Supply of metallic floor hardener for mixing in RCC complete all as specified and directed |
| 33 | Forming 12 mm thick expansion joints filled with pre formed bituminous filler with glass strip and top 30 mm primed and sealed with sealing compound Gade A depth upto 100mm complete all as specified and directed. |
| 34 | Taking down existing unserviceable rolling shutter complete of any size and any type and removing from site |
| 35 | S & F,rolling shutter with thickness of laths 1.25 mm including top cover, anchoring rod, hasp and staple, ball bearing, spring and one shop coat of primer and erect with gear operated type incl bevel gear box and crank handle, with 1.25 mm thick laths all as specified and directed. |
| 36 | Taking down rolling shutter push pull or manual type and re-fixing the same in position after necessary repairs such as cleaning , replacement of rusted nuts and bolts and necessary repair/replacement to dislocated curtain/laths with required welding/ grinding/resecuring/punching and making good any damage to the existing shutters of any size |
| 37 | Taking down rolling shutter gear operated type with lever gear box and crank handle and re-fixing the same in position after necessary repairs such as cleaning , greasing, replacement of rusted nuts and bolts and necessary repair/replacement to dislocated curtain laths with required welding /grinding/resecuring/punching and making good any damage to the existing shutters of any size complete all as specified and directed. |
| 38 | S & F Gear box assembly for rolling shutter including rod, required nuts, bolts, cleats, crank handle etc. complete of standard make and fixed in position including one coat of primer including removal of old gear box assembly and other accessories all as specified and directed. |
| 39 | S & F suitable size steel ball bearing for smooth functioning of old rolling shutter. |
| 40 | S & F steel spring of suitable size for old rolling shutter and including smooth functioning and removal of old steel spring from site all as directed. |
| 41 | M&L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of syntethic enamel paint complete all as spd & directed. |
| 42 | M&L for preparation of old steel surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of syntethic enamel paint complete all as spd & directed. |
| 43 | Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets,regulators light fittings, conduits, sunken box, etc.) and making good the disturbed surfaces of wall/floors/ceiling etc) complete all as specfied & directed. |
| 44 | Material and labour for concealed point wiring with PVC insulated unsheathed multistranded colour code copper conductor in PVC conduit with FRLS cable 1.5 Sqmm size 1100 volts grade in box of suitable thickness including one coat of synthetic enamelled black paint and providing with brass screws and cup washers including single core multi stranded FRLS copper conductor 1.5 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit all as specified and directed by Engr-in-charge for the following :- |
| 45 | (a) One light/fan/bell point controlled by one way switch 5 amps. |
| 46 | (b) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board. |
| 47 | (c) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board. |
| 48 | Material and Labour for concealed point wiring with PVC insulated unsheathed multistranded FRLS copper conductor in PVC conduit with cable 2.5 Sqmm size 1100 volts grade in box of suitable thickness including one coat of synthetic enamelled black paint and providing with brass screws and cup washers including single core multi stranded FRLS copper conductor 2.5 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit for One 3 Pin socket 15A Indepentent board |
| 49 | S&F of switch piano type 5/6amps single pole one way complete all as specified and directed. |
| 50 | S&F of switch piano type 15/16 amps single pole one way complete all as specified and directed. |
| 51 | S&F of socket outlet multipurpose 2/3 pin 5/6 amps flush button type complete all as specified and directed. |
| 52 | S&F of socket outlet multipurpose 2 in 1, 5/6 and 15/16 Amps complete all as specified and directed. |
| 53 | Supply laying testing and commissioning of XLPE insulated armoured heavy duty electric cable with aluminum stranded aluminium conductor 1100 volt grade crosssectional area 16 Sqmm 2 core LT cable complete all as specified directed |
| 54 | S&F of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and directed.NOTE (a) MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. |
| 55 | S&F of single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete including taking down old MCB's complete all as specified and directed. |
| 56 | S&F of SPN MCB 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 10 KA breaking capacity, complete all as specified and directed. |
| 57 | Supply and fix in repair LED batten luminaire surface mounted system wattage of 20 watts and system lumen efficacy=>100 lm/watt output, power factor=>0.9, color temperature 3000K- 6500 K ,voltage range - 150 to 270 volts AC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. |
| 58 | Supply and fixing in repairs energy saving environment frindly & robust highbay LED light with PDC housing suitable for Ceiling (Surface/Suspended) mounting IP 65 protected luminaire of capacity 150 watts, with efficacy not less than 150 lm/W, Wide voltage operating range of 140 V - 270 Volts & Wide temperature operating range: -10 °C to +50 °C complete all as specified and directed. |
| 59 | S&F surface mounting LED building security light fitting fitted in high pressure die cast aluminium housing not less than 35 W including fabrication of GI bracket 25mm dia suitable for fixing of LED light fitting duly fixed with clamps, nut bolts & washer etc. Fixture should have minimum efficacy at system level >=100 lumens/watt, CCT 4000-6500K, IP 66 protection with an operating voltage Range of 140-270V including all connection upto ceiling rose complete all as specified and directed. |
| 60 | S&F ceiling rose 3 phase/PVC/polycarbonate isolated body complete all as specified and directed. |
| 61 | M&L far Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 10, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Aug 27, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 11 daysAug 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender