Tender For Construction Of Mssr Tower At Porbandar Airport [Sh: Civil & Electrical Works].
Tender Value
4.08 Crore
Estimated cost
Bid Submission
27 Aug 2026
15 days left
EMD
12.24 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Rajkot → Gujarat
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Mssr Tower At Porbandar Airport [Sh: Civil & Electrical Works].
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil cum |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.Hard rock (blasting prohibited) |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 4 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Hard rock (blasting prohibited) |
| 5 | Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soilPipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and for all lift. |
| 7 | Extra for every additional lift of 1.5 m or part therof in excavation / banking excavated or stacked materials All kinds of Soil |
| 8 | Extra for every additional lift of 1.5 m or part therof in excavation / banking excavated or stacked materials Ordinary or hard rock |
| 9 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 10 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 11 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 12 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) |
| 15 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-lll) derived form natural source : 4 graded stone aggregate 20mm nominal size derived form natural source). |
| 16 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. |
| 17 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 18 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 19 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 20 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundation footing bases of coloumn, etc for mass concrete. |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : a) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landing, balconies and access platfrom. |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintles, beam plinth beams girders, bressumers and cantilevers. |
| 25 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, pliiars piers, abutments, post and struts. |
| 26 | Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 27 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Weather shed, Chajjas, corbels etc. inlcuding edges |
| 28 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every addittional height of 1 meter or part thereof (Plan area to be measured) Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) |
| 29 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 30 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500 D or more. |
| 31 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M30 grade with minimum cement content of 350 kg /cum |
| 32 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 350 kg /cum |
| 33 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 34 | Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof. |
| 35 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 36 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 37 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 38 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 39 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc. |
| 40 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 41 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm |
| 42 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete (a) 250x10 mm |
| 43 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :150x10 mm |
| 44 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : a) 125 mm |
| 45 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screwsetc. complete.Twin rubber stopper |
| 46 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge. |
| 47 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm |
| 48 | Providing and fixing 19 mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS : 710 of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws etc. complete as per direction of Engineer-in-charge. |
| 49 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 50 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 51 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover |
| 52 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 53 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 54 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 55 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 56 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 57 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Dark shade pigment using ordinary cement |
| 58 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick. |
| 59 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 60 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 61 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) joining with grey cement slurry @3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 62 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm |
| 63 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outletcomplete. |
| 64 | Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 : 2000 |
| 65 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.a) 110 mm diameter |
| 66 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler110 mm |
| 67 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single tee with door110x110x110 mm |
| 68 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee without door 110x110x110 mm |
| 69 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5°110 mm bend |
| 70 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe |
| 71 | Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 ceemnt : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 72 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) |
| 73 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 74 | 6 mm cement plaster of mix: 1:3 (1 cement : 3 fine sand) |
| 75 | Neat cement punning |
| 76 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 77 | White washing with lime to give an even shade: New work (three or more coats) |
| 78 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour.New work (two or more coats) over and including water thinable priming coat with cement primer having VOC content less than 50 gram/litre. |
| 79 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 80 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 81 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 82 | Providing and applying white cement based putty of average thichness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 83 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colourTwo coats |
| 84 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) |
| 85 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 86 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
| 87 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 88 | Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in-charge. |
| 89 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 90 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 91 | Supplying and stacking at site.Good earth |
| 92 | Supplying and stacking at site.Moorum |
| 93 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq. mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 94 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 95 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-35 grade with approved color design and pattern. |
| 96 | Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. |
| 97 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 98 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White |
| 99 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. |
| 100 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings :Flat back wash basin of size 550x400 mm |
| 101 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe32 mm dia |
| 102 | Providing and fixing toilet paper holder : a) C.P. Brass |
| 103 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes |
| 104 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work25 mm nominal dia Pipes |
| 105 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work40 mm dia nominal bore |
| 106 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore |
| 107 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 108 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 (a) 15 mm nominal bore. |
| 109 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore |
| 110 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (a) 15mm nominal bore |
| 111 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :300 mm dia. R.C.C. pipe |
| 112 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :450 mm dia. R.C.C. pipe |
| 113 | Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).500 mm dia piles |
| 114 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 115 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 116 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 117 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides. |
| 118 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 119 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): a)With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
| 120 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors , embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. a) With stainless steel cover plate minimum 1.25 mm thickness. |
| 121 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 122 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured. |
| 123 | Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 124 | Brick work with common burnt clay non modular bricks of class designation 3.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) all complete as per direction & satisfaction of Engineer In-Charge |
| 125 | Brick work with common burnt clay non modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) all complete as per direction & satisfaction of Engineer In-Charge |
| 126 | Brick work with non modular fly ash bricks of class designation 5 average compressive strength above plinth level in :Cement mortar 1:4 (1 cement : 4 coarse sand) all complete as per direction & satisfaction of Engineer In-Charge |
| 127 | Masonry work with Porbandar Stone/ Bela Stone/ Wankaner Stone in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) all complete as per direction & satisfaction of Engineer In-Charge |
| 128 | Masonry work with Porbandar Stone/ Bela Stone/ Wankaner Stone in superstructure above plinth level in:Cement mortar 1:4 (1 cement : 4 coarse sand) all complete as per direction & satisfaction of Engineer In-Charge |
| 129 | Providing and fixing 15 mm thick prepolished, machine cut Granite stone slab of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges, as required, to give high gloss finish etc. complete at all levels. |
| 130 | Providing and fixing SS Aldrop of size 250mm of approved finish, with nuts and screws etc. complete. |
| 131 | Providing and fixing SS tower bolts of approved finish, with necessary screws etc. complete :200 mm |
| 132 | Providing and fixing aluminium composite panel (ACP Sheet) of 4.0mm thickness in cladding, partition etc. all complete as per the directions & satisfaction of Engineer-in-charge . |
| 133 | Providing and fixing Circular/ Hexagonal/octagonal metallic sheet box for holding ceiling fan clamp, of dia. of approx. 140 mm, with clamp of bent bar all complete as per direction & satisfaction of Engineer In-Charge |
| 134 | Providing & fixing fly proof Stainless steel wire gauze to windows, clerestory windows, doors etc. all complete as per direction & satisfaction of Engineer In-Charge. |
| 135 | Providing and laying 15 mm thick, flamed finish Granite stone slab in required design, patterns, size, location, colour, shade & texture all complete as per the drawings over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 136 | Providing and fixing three-layer uPVC roofing sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of minimum thickness of 2 mm. The sheet shall be fixed using self drilling /self tapping screws with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 137 | Providing and erecting 2.4 metre high temporary barricading of Galvanised iron profile sheet with additional 450mm x 450mm MS holding arrangement at approx. interval of 3.0 metre, for and including 600mm dia concertina coil (the additional holding arrangement & coil to be placed as per the requirement and as directed by Engineer In-Charge) at site; with suitable MS support and bracing. The sheet shall be fixed with suitable MS section by suitable welding/riveting. Suitable arrangement shall be made to fix the barricading to avoid from overturning. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes reflective signs, marking, flags, caution tape etc. as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). |
| 138 | Providing and fixing beveled edge mirror of superior glass (of approved quality) with SS stud etc. all complete as per direction and satisfaction of Engineer In-Charge. |
| 139 | Providing and fixing 25 mm dia. CPVC ball valve of approved quality all complete as per direction and satisfaction of Engineer In-Charge. |
| 140 | Providing and fixing Pillar cock Jaquar OPP-CHR-15001PM or approved equivalent , all complete as per direction and satisfaction of Engineer In-Charge. |
| 141 | Providing and fixing 3 mm ACP (Aluminium Composite Panel) sheet of approved, quality, make & shade, in panelling fixed in aluminum doors, windows shutters and partition frames etc. with C.P. brass / stainless steel screws etc. complete as per drawings and directions of engineer-in-charge. |
| 142 | Providing and fixing false ceiling at all heights with 15 mm thick integral densified calcium silicate based false ceiling tiles of approx. size of 595x595 mm of approved texture, design and patterns, in true horizontal level suspended on suitable holding arrangements. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 143 | Providing and fixing at Window Roller blinds of approved shade & texture of Vista make or as approved by Engineer In-Charge, all complete as per direction & satisfaction of Engineer In-Charge. |
| 144 | Deduct for taking away Mild Steel items etc. all complete as as direction & satisfaction of Engineer In-Charge |
| 145 | Preparation and submission of detailed structural & architectural design & drawing of proposed Antenna tower of approximate height of 35.00 Metre including layout and landscaping (design of outer side development), drawings good for construction, services drawings, design and structural drawing for RCC structure including soil investigation and testing etc. complete. Rate of items including following stages-1. Carrying out of soil investigation as per design (latest IS code/ relevant specification) requirement and prevailing AAI guidelines.2. Preparation of Preliminary drawings, quantity calculation of RCC and Reinforcement, Bar Binding schedule (BBS) based on soil investigation report etc. for proposed provision of Antenna Tower (Foundation & superstructure) to be submitted for approval of Engineer-in-charge.3. After finalization of preliminary drawings. Submission of vetted \\" Good for construction\\" drawings in six sets & soft copy.4. Structural analysis for design of Antenna Tower including reinforcement detailing etc with relevent IS codes with upto date corrections and submission of structural working drawings.5. Drainage design and drawing details (Internal and external works).6. Water supply (Plumbing) (Internal and external works).7. Sewerage and rain water disposal plan and design of septic tank & soak pit.8. All drawings & designs along with design report shall be vetted by IIT/NIT/Govt. Engg college to be submitted in 6 sets of final drawing and design along with soft copy.9. Structural Consultant to be appointed with prior approval of Engineer-in-Charge and registered architect with council of architecture. Visit of consultant during each stage & as and when desired by EIC at the time of execution of work.10. Working drawing for road/outer side development.(Note : Concept level architectural drawings will be supplied by AAI. Contractor shall submit structural design calculation and engineering working drawing showing all relevant details needed for execution of work in required numbers. The payment for this item shall be released in stages as per decision of Engineer-In-Charge which shall be final and binding) |
| 146 | Supply of 2'x2' recessed type LED panel light with housing material - CRAC steel sheet, fixture should have minimum net efficacy at System level (Not Chip Level) >= 120 lumens/watt, luminous flux of 4200 lumen, Life of fixture 50000 hrs (minimum), CCT up to 6500K, CRI >80, PF >0.89, IP 20 and suitable for 180v- 270V AC, 50Hz. supply, Internal Surge Protection >= 3 KV. The fixture should comply with the parameters as per IS10322 and IEC60598 and LED driver shall be BIS registered & luminair manufacture shall provide LM79 report from NABL accredited lab & LM80 report issued by LED manufacturer and warranty for 05 years (minimum). |
| 147 | Supply of LED street Light fixture with housing material - Aluminum Alloy,Optic material - Polycarbonate with integrated electronic power supply unit, fixture should have minimum net efficacy at System level (Not Chip Level) >=120lumens/watt & minimum luminous flux of 5400 lumen, Life of fixture 50000hrs @ L70 Lumen maintenance, CCT upto 5700K, CRI >70, PF >=0.95, IP-66, IK-08, and suitable for 150V-275V AC, 50Hz. supply minimum internal Surge Protection >= 4KV. The fixture should comply with the parameters as per IS10322 and IEC60598 and LED driver shall be BIS registered & luminair manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer and warranty for 05 years (minimum). |
| 148 | Supply of 4 ft LED batten Tube Light fixture with housing material - Extruded aluminium housing,Optic material - Polycarbonate with integrated electronic power supply unit, fixture should have minimum net efficacy at System level (Not Chip Level) >=120 lumens/watt & minimum luminous flux of 2000 lumen, Life of fixture 25000hrs @ L70 Lumen maintenance, CCT upto 6500K, CRI >80, PF >=0.95, IP-22 and suitable for 150V-270V AC, 50Hz. supply minimum internal Surge Protection >= 3KV. The fixture should comply with the parameters as per IS10322 and IEC60598 and LED driver shall be BIS registered & luminair manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer and warranty for 05 year (minimum). |
| 149 | Supply of LED Bulkhead, pressure die cast, aluminium housing, polycarbonate diffuser, fixture should have minimum net efficacy at System level (Not Chip Level) >= 110 lumens/watt, luminous flux of 1100 lumen, Life of fixture 50000 hrs (minimum), CCT up to 6500K, CRI >80, PF >0.89, IP 66, IK08 and suitable for 180v- 270V AC, 50Hz. supply, Internal Surge Protection >= 3 KV. The fixture should comply with the parameters as per IS10322 and IEC60598 and LED driver shall be BIS registered & luminair manufacture shall provide LM79 report from NABL accredited lab & LM80 report issued by LED manufacturer and warranty for 05 years (minimum). |
| 150 | Supply of LED aviation obstruction light with high pressure die-cast aluminium housing with Red polycarbonate dome for better illumination, integral driver, IP65, feature and benifits protection against short circuit vide operating input voltage range 140V - 270 V AC, optical lens arrangement to provide 360 degre confirming to ICAO specifications complete as required. |
| 151 | Supply of 4 ft approx rechargable Inverter Batten 20 W (100 lm/W minimum) having power Back up to 10 hours (Make:-Havells, Model : Pride Plus or Equivalent from preffered make list). |
| 152 | Supply of Heavy duty Portable LED rechargable Emergency Light having battery 4500 mAh, backup upto 10 hours and having hanging arrangement (Make:-Bajaj, Model :ELX 36 LED or Equivalent approved make). |
| 153 | Supply of 1200mm dia sweep BEE 5 star BLDC ceiling fan having 5 years warranty from OEM with remote all standard accessories etc., complete as required. |
| 154 | Supply of 400mm sweep, up to 1400RPM plastic wall fan having PP material 3 nos of blade, Control Method- Pull string, Air Flow Capacity 85 cmm with 2 years warranty from OEM with all standard accessories etc., complete as required.(Make- Crompton, Model-Hiflo Wave Plus or equivalent from preferred make). |
| 155 | Supply of 300mm sweep, up to 1400RPM heavy duty exhaust fan with 2 years warranty from OEM with all standard accessories etc., complete as required.(Bajaj , Model no.Freshee or equivalent approved make). |
| 156 | Supply of 0.5HP, single phase, 230 V openwell submersible pump with starter panel board (Make : Kirloskar Model KOSi-0520 / Make- Crompton, model- OWE052(1PH)Z-21FS or equivalent in approved make). |
| 157 | Supply of 7.5 HP, three phase, 410 V, Size 80mm, Dewatering (Sewage) Submersible Pump. (Make : Kirloskar Model ETERNA 5500 CW+ or equivalent in approved make). |
| 158 | Supply of Three Phase MK2 Direct On Line (DOL) Starter suitable for 7.5 HP Sumersible pump. (Make : Lauritz Knudsen Model CS90947PODO or equivalent in approved make). |
| 159 | Supply of XLPE insulated and PVC sheathed aluminium conductor armoured cable of 1.1 KV grade conforming to IS : 7098 (Part:-I) /1988 with upto date amendments etc.,as required.of following sizes :4 C X 16 Sq.mm |
| 160 | Supply of XLPE insulated and PVC sheathed aluminium conductor armoured cable of 1.1 KV grade conforming to IS : 7098 (Part:-I) /1988 with upto date amendments etc.,as required.of following sizes :4 C X 25 Sq.mm |
| 161 | Supply of ISI‑marked HDPE pipe, PE100, 50 mm OD, SDR 11, conforming to IS 4984:2016, in standard straight lengths suitable for armoured cable laying works as per site requirement. |
| 162 | Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with good soil after laying of cable, pipe, warning tape etc ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 meters. |
| 163 | Excavation in hard rock/PCC/bituminous not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 meters. |
| 164 | laying of upto 50mm dia.(O.D.) HDPE pipe in open duct along with all accessories like socket, bend, couplers etc. with fitting, cutting and jointing etc.including alignment, complete as required. |
| 165 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.Upto 35 sq. mm |
| 166 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray/ Wall as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 167 | Supply & fixing of 1Mtr wide & 2MM Thick, ISI marked Electrical Insulating Mats Confirming to IS: 15652 / 2006 with help of SR 998 Adhesives, Working voltage upto 3.3 KV. |
| 168 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.4 C X 16 sq. mm (28mm) |
| 169 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.4 C X 25 sq. mm (28mm) |
| 170 | Supplying 3 x 2.5 sqmm FRLS PVC insulated flat submersible copper conductor, 3 core cable etc. as per site requirement. |
| 171 | Supplying of 3 Core 1.5 Sq.mm Multistraind bright electrolight annealed bear copper conductor PVC insulated / PVC sheathed multicore round flexible industrial cable for working voltage upto and including 1100 volt as per IS 694 complete etc. as required. |
| 172 | SITC of on load manual TPN change over switch-disconnector in SS enclouser , 63A , 415V,50Hz, 4 Pole etc as per site requirement (Make: L&T, model :CO10630OSOO or equivalent approved make) |
| 173 | SITC of on load manual TPN change over switch-disconnector in SS enclouser , 400A , 415V,50Hz, 4 Pole etc as per site requirement (Make: L&T, model :CO44000OSOO or equivalent approved make) |
| 174 | Supplying and fixing of 32mm dia G.I. pipe (medium class) of length 01 Mtr. for installation of street light fiting including bending the pipe to the required shape and clamp arrangement complete as required. |
| 175 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/LED fitting of all types complete with all accessories and tube etc. directly on ceiling/ false ceiling/ wall/ Pole/Banner,including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.(supporting structure for fitting , rectification of reducer, hanging arrangement or adjustment of angle of light or minor cutting and welding etc as per site requirement and stairs/ scaffolding will be under scope of this item ) |
| 176 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 177 | Installation of exhaust fan/ Wall Fan on the existing opening / door, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 178 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C |
| 179 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group A |
| 180 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 181 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 182 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 183 | Wiring for light/ power plug with 2X4 sq.mm FRLS/HFFR PVC insulated copper conductor singlecore cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copperconductor single core cable for loop earthing as required. |
| 184 | Wiring for light/ power plug with 4X4 sq. mm FRLS/HFFR PVC insulated copper conductor singlecore cable in surface/ recessed steel conduit along with 2 Nos. 4 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable for loop earthing as required. |
| 185 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.25mm |
| 186 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm |
| 187 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connections etc. as required. |
| 188 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 189 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches/LAN outlet/Telephone socket outlet/TV antenna socket outlet in recess etc as required.1 or 2 Module (75 mmX75 mm) |
| 190 | Supplying and fixing following modular item on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Data/ LAN outlet |
| 191 | Supplying and fixing following modular item on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 192 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable |
| 193 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.4 Pair |
| 194 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing and looping loop out box etc. as required. (But without MCB/RCCB/Isolator)6 way (8 + 18), Double door |
| 195 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing and looping loop out box etc. as required. (But without MCB/RCCB/Isolator)8 way (8 + 24), Double door |
| 196 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (8 + 12), Double door |
| 197 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door |
| 198 | Supplying and fixing 32 A, 415 V, TPN Industrial type socket outlet having 5 pin, with 4 pole and earth, metal enclosed plug top alongwith 32 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 199 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, DP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 200 | Supplying and fixing 63A rating, four poles, (three phase and neutral) 415 Volts, 10kA MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 201 | Supplying and fixing 63A rating, Four pole, (Three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 202 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 203 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double Pole |
| 204 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple Pole |
| 205 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40A |
| 206 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 207 | SITC of Low Impedance Digital Grounding System 240kA Three Phase four wire LIDGS 4th Generation equipment Grounding & bonding system with built in 100% Lightning and Surges, static charge, Noises, ESD, EPR and abnormal electrical characteristics eliminator which enter from power and other service lines and ensuring clear bonding potential (earth to Neutral voltage) less than 1.0V, a digital 3 Digit LCD Impulse real Date time Counter with threshold of 1KA, self health visual status indicator, built Zero leakage Current based solution. Lightning Impulse Current Discharge Capability up to 12 KA (10/350μsec) Surge Discharge Current Capability up to 40KA (8/20μsec) 7 Modes of Protection (L1-N, N PE, L1- PE) total surge handling capacity 240KA Shortcircuit extinguishing and limiting capabilities up to 25KArms without tripping of Letthrough- energy of less than 01 Joule in a Pre-wired pulverulent body painted metal enclosure to be connected in parallel to the power supply circuit,Conforming solution CE NABL IEC 61643-11 -2011 along with all accessories. |
| 208 | SITC of 1 phase module, 24 Hours Programmable Digital Automatic Time Switch , 240V,50Hz, etc having Contact rating of 1 changeover contact 16A, 250V,Programmes -56, Battery reserve-5 years, Working ambient: -20°C to +55°C, Accuracy: ~ 0.1 s / day in suitable Enclosure as per site requirement (Make- Legrand, Cat No.- 412631, Model- APHAREX D21 or equivalent AAI approved make ) |
| 209 | Provision of IP68 Hydrogen gas detector having facility to detect Combustible gases – Lower Explosive Limit (LEL), Oxygen (O₂), Hydrogen Sulfide (H₂S), Carbon Monoxide (CO), Sulfur Dioxide (SO₂) having warranty of 3 years (minimum) from OEM or authorized OEM delaer.(Make and Model- MSA Altair 4xR Multi Gas Detector or Equivalent) |
| 210 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, with prefabricated bend, Tee, cross member, reducer joints, coupling plate & nuts bolts etc as per site requirement in convenient sections, joined with connectors, suspended from the deck slab / ceiling / high roof truss / wall etc with G.I. suspenders (for ceiling) / MS angel 35 x 5 mm (for Wall / Floor) including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 211 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, with prefabricated bend, Tee, cross member, reducer joints, coupling plate & nuts bolts etc as per site requirement in convenient sections, joined with connectors, suspended from the deck slab / ceiling / high roof truss / wall etc with G.I. suspenders (for ceiling) / MS angel 35 x 5 mm (for Wall / Floor) including G.I. bolts & nuts, etc. as required.300 mm width X 62.5 mm depth X 2.0 mm thickness |
| 212 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, with prefabricated bend, Tee, cross member, reducer joints, coupling plate & nuts bolts etc as per site requirement in convenient sections, joined with connectors, suspended from the deck slab / ceiling / high roof truss / wall etc with G.I. suspenders (for ceiling) / MS angel 35 x 5 mm (for Wall / Floor) including G.I. bolts & nuts, etc. as required.600 mm width X 62.5 mm depth X 2.0 mm thickness |
| 213 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. |
| 214 | Supplying, installation,testing & commissioning of IP based Addressable fire alarm panel,LCD display, suitable for 02 loop, the panel should be equipped with loop capacity to take minimum 120 intelligent addressable detectors/ devices (In any combination) in one loop complying relevant national fire alarm code for local fire alarm system with mimic diagram for all area / zone covered,complete with all connections.The panel shall have input of 240 volts AC power supply,inbuilt automatic battery charger, 24volts, 2X12volts, 7Ah sealed lead acid maintenance free batteries sufficient for 24 hours normal power backup & working, interconnections. The panel shall be UL / EN / FM listed and along with GSM auto dialer facility (20 Nos min.) etc. as required. |
| 215 | Supply, Installation, Testing & commissioning of UL / EN listed (latest version) addressable Smoke detector base and with unique optical sensing chamber, visible LED, fully coated circuit board, superior RF / Transient protection suitable for 2 wires loop connection, complete with plug into common separate base & housing constructed of LEXAN (or polycarbonate) complete with connections etc. as required and to be installed below / above false ceiling roof and concealed space and as per enclosed specifications ,complete as required. (Cost of plug in common base shall deemed to be included in cost of detectors). |
| 216 | Supply, Installation, Testing & commissioning of UL / EN listed (latest version) Addressable Manual call station (Resetable pull / push type) suitable for semi flush mounting, IP 54 for indoor use & IP 65 for outdoor use with inbuilt fault isolator / isolator module with double gang outlet box, equipment for key operated test-reset lock. Manual pull station shall be connected with two wire to SLC loop of Fire Control Panel. Cover shall be made out of LEXAN (or poly carbonate equivalent) with clear operating instruction and the word Fire appearing on the front complete with connections etc. as required and as per enclosed specifications. |
| 217 | Supply, installation, testing and commissioning of UL / EN listed (latest version) Hooter-cumstrobe with inbuilt fault isolator / isolator module with adjustable sound level in the range of min. 90 db to Max. 120 db at 1M distance complete with termination etc. as required and as per enclosed specification. |
| 218 | Supply, Installation, Testing and commissioning of UL/EN listed (Latest Version) Response Indicator for getting fire indications of detectors i/c mounting boxes installed above/below false ceiling area interconnecting to loop cable complete as required. |
| 219 | SITC of 2.8 kg Aerosole based automatic fire exingushers approved by BIS / NABL / EN / UL/any regulatory authority along with complete system required to operate in case of fire complete as required. |
| 220 | Supply and fixing of Aerosol fire Extinguishing Generator - 8 Gram |
| 221 | Supply and fixing of Aerosol fire Extinguishing Generator - 20 Gram |
| 222 | SITC of 2 Zone Gas release panel complete with battery back up complete as required. |
| 223 | Supplying, installation, testing & commissioning of conventional type smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 224 | Supplying, installation, testing & commissioning of conventional type heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. |
| 225 | SITC of Monitor Module complete as required. |
| 226 | Providing and fixing of Dry Chemical Powder (UL Listed MAP-50% ABC) 6 Kg, Stored Pressure Type, UGTS Pressure Gauge, Controllable discharge mechanism, Jet Range 5 Meters, applicable on Class A,B & C and electrically started Fire, A Rating- 3A, B Rating 21B, Can Construction : Deep drawn & CO2 Mig welded, CE Marked Valve with inbuilt NRV & Safety Release Provision, EPDM Rubber Hose with both end Aluminum clamped, External Coating - Pure Polyester Powder coating (UV Resistant), Brass forged valves with safety Pin is of SS material, Helium Leak Detection Tested, ISI Approved IS 15683:2006 and CE Certified. |
| 227 | Shifting of nozzle of existing gas suppression system from one location to another within a maximum distance of 15 meters in the same system, including careful dismantling of the existing nozzle and associated fittings, supply of additional carbon steel seamless ASTM class pipe or as per OEM recommendation piping and accessories, re-routing of the piping to the new designated location with proper supports and clamps, re-installation of the nozzle in accordance with OEM specifications, and testing of the relocated section for leak-proof performance and operational compliance. |
| 228 | Supply, fixing, testing and commissioning of single spike air terminals of following lengths and dia as required and as per site conditions. the air terminal shall be manufactured with copper coated steel. The terminal shall be provided with the integrated / attached threaded base support suitable for mounting the terminals as per site condition. The base support shall be minimum 3 mm thick and shall have inbuilt connector fitting for connection of lightning conductor in such a way that conductor contact area shall not be less than 40mm on all side of the conductor as per IS/IEC 62305.a) 2000 mm- 10 and 16 mm dia (Bottom 1mtr 16 mm dia and other 1mtr 10 mm dia) |
| 229 | Providing and fixing 8 mm dia copper clad steel round conductor for air termination network at parapet wall. Including providing suitable parapet conductor holder, Tee, Straight & cross connector etc. on parapet wall, roof and vertical facade of mesonery / glass / metalic work as per IS/IEC 62305. |
| 230 | Supply and fixing of copper Bridging cable of 16 sqmm including lugs to connect air termination rod with any metallic structure on the roof as per IS/IEC 62305 |
| 231 | Providing and fixing 8 mm dia copper clad steel round conductor for Down conductors to be installed on vertical façade of mesonery / glass / metalic work. Including providing connector holder etc and install at every 1 mtr. as per IS/IEC 62305. (For vertical run) |
| 232 | Supply, fixing, testing and commissioning of Lightning Strike counter for counting the number of lightning strikes without any power supply. The Counter should be mounted on the Down Conductor. The Lightning Counter should be IP65 rated enclosure suitablefor external application as per IS/IEC 62305. |
| 233 | Supply and fixing of Test Link to disconnect the down conductor from the earth termination network for regular checks of the earth terminaton resistance value. (with stainless steel enclosure) as per IS/IEC 62305. |
| 234 | Supply and fixing of Expansion piece of made of 8mm Copper clad steel (CCS) to maintain the flexibility to the conductor due to heat IS/IEC 62305. |
| 235 | Providing and laying 10 mm dia. Copper clad steel (CCS) Conductor laid at 500mm below the ground, as required and as per specification and code of practice IS/IEC 62305. |
| 236 | Supply and fixing of Maintenance Free Earthing termination made of copper-bonded rod of 10 feet length, 14.2 mm dia. (Minimum copper bonding shall be 0.25mm) along with Rod-to-Conductor connectors, Carbon based Earth enhancement material 25 kg, including earth excavation, filling, PVC Pit Cover and other accessories as required and as per IEC 62561/IS:3043-2018 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysAug 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender