Road Transport and Highways Government Departments Closing in 9 days TDR #56873549

Tender For Renovation Work Of Electrical Installation In Workshop, Washing Plant And Other Allied Works At Dtc Sarojini Nagar Depot.

Issued by Government Departments · Delhi, Delhi
Tender Value
26.01 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
9 days left
EMD
52025
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation Work Of Electrical Installation In Workshop, Washing Plant And Other Allied Works At Dtc Sarojini Nagar Depot.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 07-Aug-2026 Corrigendum I Date 17-Aug-2026

BOQ

Name of Work:- Renovation work of electrical installation in workshop, washing plant and other allied works at DTC Sarojini Nagar Depot.
Sl. No. Item Description
1Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
3Group C
4Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
5Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulatedcopper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
6Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
72 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
82 X 6 sq. mm + 1 X 6 sq. mm earth wire
94 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
10Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
11Group C
12Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
133 x 4 sq. mm
14Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1525 mm
16Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
175/6 A switch
1815/16 A switch
193 pin 5/6 A socket outlet
206 pin 15/16 A socket outlet
21Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
223 Module (100 mmX75 mm)
236 Module (200 mmX75 mm)
248 Module (125 mmX125 mm)
2512 Module (200 mmX150 mm)
26Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
27Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
28Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
29Group C
30Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
31100 A, 30kA, FPMCCB
32Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
3312 way, Double door
34Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
358 way (4 + 24), Double door
36Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
374 way (4 + 12), Double door
388 way (4 + 24), Double door
3912 way (4 + 36), Double door
40Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
41Single pole
42Double pole
43Triple pole
44Triple pole and neutral
45Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
46Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
47Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
48Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
49Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
50Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
51Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
52Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
53Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.
54Upto 35 sq. mm (clamped with 1mm thick saddle)
55Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mmMS flat clamp)
56Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
573 X 10 sq. mm (22mm)
584 X 10 sq. mm (25 mm)
594 X 16 sq. mm (28mm)
604 X 25 sq. mm (28mm)
614 X 50 sq. mm (35 mm)
62Supply of XLPE insulated PVC Sheathed Armoured Aluminium Conductor cable1.1KV Grade Conforming to IS-7098 of size 3x10 Sq. mm.
63Supply of XLPE insulated PVC Sheathed Armoured Aluminium Conductor cable1.1KV Grade Conforming to IS-7098 of size 4x10 Sq. mm.
64Supply of XLPE insulated PVC Sheathed Armoured Aluminium Conductor cable 1.1KV Grade Conforming to IS-7098 of size 4x16 Sq. mm.
65Supply of XLPE insulated PVC Sheathed Armoured Aluminium Conductor cable 1.1KV Grade Conforming to IS-7098 of size 4x25 Sq. mm.
66Supply of XLPE insulated PVC Sheathed Armoured Aluminium Conductor cable 1.1KV Grade Conforming to IS-7098 of size 4x50 Sq. mm.
67LED Batten light 18- 22 watt (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). CRCA Sheet Body (Thickness ≥ 0.50 mm)
68Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.[1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)]
69LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with ,70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) CRCA Sheet Body (Thickness ≥ 0.50 mm) 36 watt
70LED Flood Light , powder coated pressure die cast aluminum (System lumen efficacy ≥120 and <135 lm/Watt) Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 degto 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
7150 watt
72100 watt
73250 watt
74S/I/T/C of LED High Bay Flood Light 100 watt robust highbay LED with PDC housing suitable for ceiling (Surface/Suspended) mounting with system efficacy ≥ 150 lm/W including all accessories for mounting/fixing and connection of highbay lights as per site requirement.
75S/I/T/C of 600mm Industrial Wall fan 1440 RPM single phase including all accessories for mounting/fixing and connection of fans as per site requrement.
76Supplying, fixing and Installing of 63A 4-Pole rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of Three poles and Neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.
77S/I/T/C of 300mm Exhaust fan heavy duty 1400 RPM single phase
78S/I/T/C of 380mm Exhaust fan heavy duty 1400 RPM single phase
79S/I/T/C of Main LT Panel, floor-mounted, indoor, fixed type, fabricated from 1.6 mm CRCA sheet with 2.0 mm CRCA door, complete with 200A TPN aluminium busbar, 125A, 4P, 36kA MCCB incomer with rotary handle and spreader link, 5 Nos. 63A, 4P, 25kA MCCB outgoing feeders with rotary handles and spreader links, R-Y-B LED indication lamps, VIF meter, 3 Nos. 100/5A CTs, 3 Nos. 6A SP MCBs for metering circuits, PVC insulated internal copper wiring, colour-coded busbar sleeves, insulators, ferrules, cable channels, panel locks, hardware and all other accessories required for complete operation, including factory wiring, testing, inspection and commissioning, complete as required.(IP-4X)
80Dismentling work of all old defective electrical installtions (including cable, DB, wiring etc).
81Salvage value of old defective ceiling fan
82(+) Add prevailing cost index @ 31.27% On DSR-2016 Amount i.e. on :
83(-)@9.5% below on (DSR-2016 Rate+Add prevailing cost index @ 31.27%) on : Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56873549
AUTHORITY Government Departments
TENDER VALUE 26.01 Lakhs
LAST DATE 17-08-2026
Authority
Authority Name Delhi Transport Corporation
Work Description Tender for Renovation Work Of Electrical Installation In Workshop, Washing Plant And Other Allied Works At Dtc Sarojini Nagar Depot.
Basic Detail
Tender No Dy. CGM (Civil)/ CED/ Elect. / 2026-27/08
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 07 Aug 2026
Submission Date 17 Aug 2026
Open Date 17 Aug 2026
Finance
Tender Value 26.01 Lakhs
Tender Fee Ref. Documents
EMD 52025
Exemption Not Available
Document List
Tendernotice_1 (11).pdf
BOQ_394857.xls
c8bce38d-233f-487b-82c5-8f93e75639f0.html
Tenderdocument.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 9 days
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1 (11).pdf

xls

BOQ_394857.xls

html

c8bce38d-233f-487b-82c5-8f93e75639f0.html

pdf

Tenderdocument.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders