Tender for Renovation And Reconfiguration Of Office Floor Through Interior Fit- Out Works For Creation Of Executive Chambers And Additional Workstations Including Modular Aluminium Partitions, Decorative Wall Lining And Associated Electrical Installations At Power House, Dulhasti Power Station, Kishtwar
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC Conduit with modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group-B) |
| 2 | Wiring for circuit/ submain wiring along with earth wirewith the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.A) 2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire |
| 3 | Wiring for Power circuit/submain alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit as required. B) 2X 4 sq.mm + 1X 4 sq.mm earth wire |
| 4 | Supply and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.surface/recessed including cutting the wall and making good the same in case of recessed conduit as required. A) 1 or 2 Module (75mmX75mm) |
| 5 | Supply and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.surface/recessed including cutting the wall and making good the same in case of recessed conduit as required. B) 3 Module (100mmX75mm) |
| 6 | Supply and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.surface/recessed including cutting the wall and making good the same in case of recessed conduit as required. C) 6 Module (200mmX75mm) |
| 7 | Supply and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.surface/recessed including cutting the wall and making good the same in case of recessed conduit as required. D) 8 Module (200mmX75mm) |
| 8 | Supply and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.surface/recessed including cutting the wall and making good the same in case of recessed conduit as required. E) 12Module (200mmX150mm) |
| 9 | Supply and fixing following moduler switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. A) 5/6 A switch |
| 10 | Supply and fixing following moduler switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. B) 15/16 A switch |
| 11 | Supply and fixing following moduler switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. C) 3 pin 5/6 A socket outlet |
| 12 | Supply and fixing following moduler switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. D) 6 pin 15/16 A socket outlet |
| 13 | Supply and fixing following moduler switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. E) Telephone socket outlet (With RJ45 Jack) |
| 14 | Supply and fixing following moduler switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. F) Telephone socket outlet (With RJ11 Jack) |
| 15 | Supply and fixing 5 A to 32 A rating, 240/415V, 10KA, \\"C\\" curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) Single pole |
| 16 | Supply and fixing following rating double pole, 240V, Isolator in existing MCB DB complete with connections, testing and commissioning etc. as required. A) 40A |
| 17 | Supply and fixing following rating double pole, 240V, Isolator in existing MCB DB complete with connections, testing and commissioning etc. as required. B) 63A |
| 18 | Supply and fixing following way single pole and neutral , sheet steel, MCB distribution board, 240V on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnection, power painted including earthing etc. as required (but without MCBs and incomer ). A) 16 way , Double door |
| 19 | Supply and drawing UTP 4 Pair CAT 6 LAN Cable in the existing surface/ recessed steel/PVC conduit as required. A) 1 run of cable |
| 20 | Supply and drawing follwing Pair 0.5mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/PVC conduit as required. A) 1 Pair |
| 21 | Supply of LED panel light 2*2 feet 36 Watt |
| 22 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar |
| 23 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead : of area of 3 sqm. and below |
| 24 | Dismantling aluminum / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge. |
| 25 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead.For thickness of tiles 10 mm to 25 mm |
| 26 | Flooring with marble stone of specified thickness as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including rubbing, polishing and curing complete with: 18 mm, Makrana White Second quality |
| 27 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mmdrop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powdercoated of thickness 60 microns (minimum), including factory painted after bending. |
| 28 | Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge. |
| 29 | Providing and fixing in wall lining of specified medium density board, pre-laminated one side decorative lamination other side balancing lamination Grade I, exterior grade, with necessary fixing arrangement and screws etc. complete.MDF board IS: 1998 marked 12 mm thick |
| 30 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (Area of slab upto 0.5 sqm) 16MM |
| 31 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 32 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 33 | Half brick masonry with common burnt clay (non-modular) bricks of class designation7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 34 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 35 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 36 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040mm bowl depth 250mm |
| 37 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 20mm nominal outer dia pipes. |
| 38 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete:Flexible pipe 40 mm dia |
| 39 | Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. |
| 40 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 41 | Providing and fixing un plasticized P.V.C. connection pipe with PTMT nuts, collars and bush of approved quality and colour 15 mm nominal bore with 45 cm length. |
| 42 | Providing and fixing 110 mm uPVC single socketed pipe and fittings as per direction of Engineer-in-charge : External work including trenching, refilling etc. |
| 43 | Providing and fixing factory made PVC door frames of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and jointed with two numbers of 150mm long brackets of 15x15mm MS square tube, the vertical door profiles to be reinforced with 19x19mm MS square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using MS screws of 65/100mm size complete as per manufacturers’ specifications and directions of engineer-in-charge |
| 44 | Providing and fixing 30 mm thick door shutters to existing door frames. Fiberglass reinforced plastic (FRP) Flush door shutter in different plain and wood finished made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate all around with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/ polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of FRP laminate confirming to table- 3 of IS : 14856-2000, complete as per directions of engineer-in-charge. |
| 45 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing,panelling and dash fasteners to be paid for separately.For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately . Powder coated aluminum (minimum thickness of powder coated 50 microns) |
| 46 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer- in-charge. (Cost of aluminum snap beading shall be paid in basic item.) With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm) |
| 47 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including:a) Structural analysis & design and preparation of shop drawings for pressure equalization or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metallic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanized with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi- metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material &labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 48 | Providing and fixing aluminum tower bolts ISI marked anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with necessary screws etc. complete : 250x10 mm |
| 49 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.125 mm |
| 50 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm |
| 51 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete |
| 52 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 53 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 54 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats |
| 55 | Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-in- charge (Frame work shall be paid for separately). 6mm thick commercial ply conforming to IS : 1328 BWR type |
| 56 | Providing and fixing 12 mm thick pine wood decorative lining tongued and grooved, including providing wooden plugs complete with necessary screws and priming coat on unexposed surface & polishing of exposed surface etc. complete. |
| 57 | CARRIAGE OF MATERIALS By Mechanical Transport including loading, unloading and stacking- Lime, moorum, building rubbish 2 km |
| 58 | CARRIAGE OF MATERIALS By Mechanical Transport including loading, unloading and stacking- Cement, stone blocks, G.I. C.I., A.C., Stainless Steel & C.C. pipes below 100 mm dia and otherheavy materials 2 km |
| 59 | CARRIAGE OF MATERIALS By Mechanical Transport including loading, unloading and stacking- Bricks |
| 60 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 61 | Providing and fixing aluminum die cast body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessoriesand screws etc. complete : |
| 62 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 63 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 64 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender