Housing Urban and Rular Development Local Bodies Closing in 1 days TDR #56871104

Tender For maintenance of Various Colonies Under Horticulture Zonesh:-Maintenance Of Iei, Cctv, Epbax System And Other Electrical Installation At Office Complex Of Electrical Division -13 & Horticulture Division-9/Dda. Estimated Cost :- ₹ 8,37,373.00

Issued by Local Bodies · Delhi, Delhi
Tender Value
8.37 Lakhs
Estimated cost
Bid Submission
12 Aug 2026
1 days left
EMD
16747
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for maintenance of Various Colonies Under Horticulture Zonesh:-Maintenance Of Iei, Cctv, Epbax System And Other Electrical Installation At Office Complex Of Electrical Division -13 & Horticulture Division-9/Dda. Estimated Cost :- ₹ 8,37,373.00

BOQ

Name of Work:- M/o various colonies under Hort. ZoneSH:-Maintenance of IEI, CCTV, EPBAX System and other electrical installation at office complex of Elect. Division -13 & Hort. Division-9/DDA. Estimated Cost :- ₹ 8,37,373.00
Sl. No. Item Description
1Maintenance of IEI, fans and other Electrical installation at office building of Elect. Div-13, Horticulture Div-9 /DDA as per inventory attached by deploying staff as per terms and conditions attached.
2Providing and Replacement of Digital Telephone System having 4 P&T Lines & 16 Single Line Extension, 8 VoIP Trunks, 10 SIP Extensions having standard features including line cord with RJ-11/45 connectors to connect system to MDF complete etc. as required.
3Providing and replacement of Digital Key Telephone with 20 (4 Context Sensitive Keys, 16 DSS Keys) Programmable keys, Polyphonic Ringtone, Full Duplex Speaker Phone, Hold, Conference,Redial, Transfer, Message Wait Lamp, Ringer Lamp complete as required.
4Providing and fixing of 50 Pair MDF Box with lock & key for 3 Nos. Krone make 2/10 Connection-Disconnection module complete etc. as required.
5Comprehensive Annual Repair & Maintenance of existing CCTV surveillance system with. 2 MP camera (20 Mtr. IR Range), 1 Nos. NVR, With Giga PoE Switch etc., Full HD LED Monitors, complete with CAT-6 i/c upkeep of recording, data process complete etc. as reqd. as per additional terms and conditions attached.
6Supplying and replacement of inverter tabular battery of 150 AH i/c connection and testing etc as required
7Supplying and replacement of following piano type switch/ socket on the existing switch box/ cover includingconnections etc. as required.
85/6 Amp one way switch Piano type ISI marked
93 Pin 5/6 Amp socket outlet piano type ISI marked
1015/16 Amp one way switch Piano type ISI marked
116 Pin 15/16 & 5/6 Amp socket & replacement /HFFR out let, piano type ISI marked
12Supplying of FRLS PVC insulated single core copper conductor cable of following size.
131.5 sqmm.
144.00 sqmm.
15Supplying, replacement, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hourswith 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing requiredfor LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18-22 Watt
16Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required.
17Single Pole
18Double Pole
19Supplying of following pair 0.5 mm dia FRLS PVC insulated copper conductor unarmoured telephone cable in the existing surface/recessed stell/PVC conduct as reqd.
201 Pair
213 Pair
224 Pair
23Rewinding copper winding & repairing of 18\\"/20\\" desert cooler fan motor of different make 900/1400 rpm, testing etc complete as
24Rewinding of 48\\" ceiling fan with suitable copper winding wire, oiling , greasing, servicing, dismantling and re-assembling along with testing, commissioning etc. as reqd.
25Routine preventive maintenance of Air conditioners Window Type up to 1.5-ton capacity &, cleaning of filters & grills of A.C. cleaning, complete as required
26Routine preventive maintenance of Air conditioners Split Type up to 1.5-ton capacity &, cleaning of filters & grills of A.C. cleaning, complete as required
27Comprehensive Annual Maintenance of RO System 50 LPH capacityconnected with water coolers i/c three mandatory services (cleaning of All Filters), repair/ replacement of all electrical and electronic spare parts and one time replacement of consumables once in a year like Particulate Filter 20” or (2 x 10”), Sediment Filter 20” or (2 x 10”), Pre Carbon Filter 20” and Post Carbon Filter 20” (except membranes), attending complaints within 24 working hours with completeoverhauling and servicing etc. as required. Dismantle material, etc, complete as required
28LED Panel light 2x2 ft. (System lumen efficacy≥120 <135 lm/Watt)Supplying, Replacement, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free,(flicker should be below 5 %), life time (LED, Driver& electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specifiedrating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥120 <135 lm/Watt output.LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness >0.50 mm) 36 watt
29Supplying and fixing of Powder Fire Extinguisher (Gas Cartridge type) Capacity 06 Kg duly ISI markedconforming to IS: 15683:2018, with IS 4308, ISI marked ABC powder; Complete with IS 4947 ISI marked Gas Cartridge with squeeze grip release valve, discharge pipe, locking arrangement, operation manual and bracket. Operating Temperature: -30ºCto + 60ºC Complete in all respect.
30Brush Less Direct Current (BLDC) Fan with RemoteSupply, Replacement, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value(CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion)less than 10%, remote (preferably mobile app based) for speed control and all remaining accessoriesincluding safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/cexternal connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cableand earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum)
31Supplying, installing, testing and commissioning of sewage submersible pump set of 3 HP (2.20 kW), 415 V, 3-phase, 50 Hz, 3000 RPM, with 50 mm delivery outlet, having discharge capacity of 100–600 LPM at a head range of 3–17 m and capable of handling solids up to 35 mm, suitable for dewatering applications, complete in all respects as per direction of Engineer-in -Charge. make:- Crompton, kirloskar,KSB,Shakti
32Supplying of PVC insulated, PVC sheathed copper conductor submersible flat cable, ISI marked, 3 Core × 2.5 sq.mm, in existing sump/tank , etc., complete as required
33Supplying HDPE laminated lay flat delivery hose (tube) of 150 mm (6 inch) diameter for transfer/discharge of water through pumps, complete with necessary clamps and couplings, as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56871104
AUTHORITY Local Bodies
TENDER VALUE 8.37 Lakhs
LAST DATE 12-08-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for maintenance of Various Colonies Under Horticulture Zonesh:-Maintenance Of Iei, Cctv, Epbax System And Other Electrical Installation At Office Complex Of Electrical Division -13 & Horticulture Division-9/Dda. Estimated Cost :- ₹ 8,37,373.00
Basic Detail
Tender No 24/EE/ELD-13/DDA/2026-27 (SPLZ)
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 06 Aug 2026
Submission Date 12 Aug 2026
Open Date 13 Aug 2026
Finance
Tender Value 8.37 Lakhs
Tender Fee Ref. Documents
EMD 16747
Exemption Not Available
Document List
BOQ_967768.xls
f6148a02-02f7-4ceb-9fca-2dbfd156c030.html
Tendernotice_1.pdf
Tendernotice_2 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Aug 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_967768.xls

html

f6148a02-02f7-4ceb-9fca-2dbfd156c030.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders