Tender For Development Work At Murli Manohar Temple , Dwarika, Gujarat.
Tender Value
1.85 Crore
Estimated cost
Bid Submission
01 Sep 2026
21 days left
EMD
3.70 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jamnagar → Gujarat
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Development Work At Murli Manohar Temple , Dwarika, Gujarat.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead: For thickness of tiles 25mm to 40mm. |
| 2 | Dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. |
| 3 | Demolishing mud phuska/ Lime dhar/ Kharanja in terracing and disposal of unserviceable material within 50 meters lead. |
| 4 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. 1: 3: 6 or richer mix. |
| 5 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. |
| 6 | Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead: |
| 7 | Of area 3 square meter and below. |
| 8 | Of area exceeding 3 square meter. |
| 9 | Providingand laying inposition cement concrete including curing,compactionetc.completeinspecifiedgradeexcluding thecostofcenteringandshuttering-Allworkuptoplinth level. |
| 10 | M10 grade Nominal Mix1:3:6(1cement :3coarsesand:6gradedstone aggregate 20mm nominal size). |
| 11 | Crazy marble stone flooring 20mm thick marble stone with black or of specified colour topping including filling the gaps with cement marble chips mix in proportion of 4 : 7 (4cement : 7 white black or white or black marble chips) size from 1mm to 4mm by volume and under layer of 25mm thick cement concrete [1:2:4, graded stone aggregate 12.5mm nominal size] rubbing and polishing and cement slurry etc. complete : In ordinary cement. |
| 12 | ProvidingandfixingMarblestoneflooringtablerubbed,1518mmthickover20mm(Av.)thickbaseofCM1:4(1cement : 4 coarse sand) jointing with white cement mortar 1:2 (1 white cement:2marbledust)withpigmenttomatchtheshadeofthe marble slab including grinding, rubbing and polishing complete.Makrana 'Adanga'. Above 3601 Cm2 Slabs |
| 13 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering.M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 14 | Plaster onnewsurface onwall in cement sandmortar 1:3 including racking of joints etc. complete fine finish : 25 mm thick |
| 15 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches by sandla/loi. (only for colour changing ). |
| 16 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) |
| 17 | Applying one coat of Cement primer of approved brand and manufacture on wall surface including all scaffolding |
| 18 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of basewith primer, putty, lippy etc complete in all respect. |
| 19 | Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision New Work |
| 20 | Providing and fixing double scaffolding system on the exterior side, upto five story made with 4\\" wooden member 1.5 m c/c horizontal and vertical direction joining with rassi, clamps, challies. The scaffolding system shall be stiffened with bracing, runner, connection of building if necessary with all essential safty features for the workmen etc complete as per direction of EI.The lavation area of the scaffolding shall be measured for payment. The payment will be made once irrespective of duration of scaffolding. Note : This item to be used for maintence work judicially |
| 21 | Add extra for mirror polishing on existing marble work/ Kota stone flooring work where ever required to give high gloss finish complete. |
| 22 | Pointing on stone masonry in cement sand mortar 1:3 (1 cement : 3 sand) : Deep groove pointing |
| 23 | Grading roof for water proofing treatment with water proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 24 | Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer in charge :In cement mortar. |
| 25 | CARRIAGE OF MATERIALSBuildingRubbishStonemetal(Grit and ballast etc.) For 10 Km. |
| 26 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked ( IS:14927 P - II ) virgin material UPVC trunking & it's accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/ Surface Moulded virgin material UPVC Modular Box , 10 A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose/holder /3 way Connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 27 | Short point (up to 3 mtr.) |
| 28 | Medium point (up to 6 mtr.) |
| 29 | Long point (up to 10 mtr.) |
| 30 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked ( IS:14927 P - II ) virgin material UPVC Trunking & it's accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/ Surface Moulded virgin material UPVC Modular Box, modular 10A switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 31 | On board |
| 32 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. |
| 33 | 3x 1.5 sq.mm (For Extra Point Wiring) |
| 34 | 2 x 2.5 sq. mm. + 1x1.5sqmm (For Light & emergency circuit) |
| 35 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. (For Power & AC Circuit) |
| 36 | 4 x 6.0 sq.mm (For Sub Mains) |
| 37 | 1 x 4.0 sq.mm (For Earthing) |
| 38 | P & F P.V.C. sheet 2.0 mm thick of following size Including screws, cup washer as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR100 mm dia. |
| 39 | Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item. |
| 40 | Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required.5 step fan regulator 2 Module 360 dgree rotating |
| 41 | Providing & Fixing of modular type lockable feature socket duly made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. NOTE- ONLY COMPUTER POINTS SET. |
| 42 | 6 A 3/5 pin shuttered socket |
| 43 | 6/16 A shuttered socket |
| 44 | Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. |
| 45 | Blanking plate |
| 46 | Providing & Fixing of Wiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge. NOTE- ONLY COMPUTER POINTS SET. |
| 47 | 1-2 Module |
| 48 | 6 / 8 module |
| 49 | S&F following sizes of ISI marked ( IS:14927 P - II ) virgin material UPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 50 | 25 mm x 12 mm |
| 51 | 32 mm x 12 mm |
| 52 | 38 mm x 16 mm |
| 53 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 54 | Single pole MCB (With B/C curve tripping Characteristics) |
| 55 | 6 A to 32 A rating |
| 56 | Double pole MCB(With B/C curve tripping Characteristics) |
| 57 | 50/63 A rating |
| 58 | Four pole MCB (With B/C curve tripping Characteristics) |
| 59 | 40 A rating |
| 60 | 50/63 A rating |
| 61 | Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.Two pole 100/300mA sensitivity6A-32 A rating |
| 62 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 63 | Metal door (Three phase) IK-09 and IP-43 with Metal end box |
| 64 | 4 Way |
| 65 | Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. |
| 66 | Double door IP-43 & IK-09 with Provision of Incomer MCCB 160 A Rating with Metal end box |
| 67 | 8 Way |
| 68 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. |
| 69 | 3 pole MCCB With Thermal Magnetic release |
| 70 | 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 71 | Providing & Fixing of 400 mm Sweep BLDC technology Oscillating typeWall mounting / Pedestal type fans with Three speed, ON and OFFposition, Double Wall bearing with front and back 120 or more ribsguard; Three no. blades, noise level should be <= 75 dB, including fixingwith anchor bolts, making connection testing etc. as required. ( WithRemote ) All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure \\"A\\" attachedwith this BSR .Wall mounting type with Service value 2.0 CMM /W, Min. Air Delivery 71CMM |
| 72 | Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |
| 73 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture madefrom Powder coated Extruded aluminium housing with in built driver , System lumenefficacy ≥110lm/Wattoutput,internalsurgeprotection of 2.5 KV with Short & Open circuitprotection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hourswith , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more thanthe specified rating and Fixture shall be of BIS standardandtrademarkcertificate( T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEMmust have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 &LM80) certificate / Report from OEM shall besubmitted. All as per pre approved byEngineer in charge.Foradditional technical parameters of products/ work , referAnnexure \\"A\\" attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm |
| 74 | Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 75 | 1.5 TR ISEER not less then 3.8 |
| 76 | Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrial plug top making connection etc complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 77 | 4 kVA |
| 78 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 79 | Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .25 mm |
| 80 | Supply, installation, testing and comissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 81 | 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) |
| 82 | 15.9 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) |
| 83 | Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .Armoured4 core x 2.5 Sq.mm |
| 84 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. |
| 85 | 10.0 Sq. mm 4 core |
| 86 | 4.0 Sq. mm (EXTERNAL LIGHTING)4 core |
| 87 | Removing of old lime plaster up to 75 mm thick in patches with height up to 4.5 m. Disposal up to 100 meter lead |
| 88 | P & L Lime Surkhi Plaster lime surkhi mortar 1:2 (1 Lime : 2 Surkhi) including preparation of mortar by traditional practice (by grinding) in specified course for base coarse and subsequent course & Loi, tamping, beating, curing till the shrinkage cracks are disappear. The work is to be done with all lead as the work is of restoration nature as per Jaipur practice including adding gur, methi & gugal on old walls including removal of all old loose and decade plaster, each coat to be done after 3 days of previous coat. 45 mm thick in four coats |
| 89 | Add extra for Lime plaster work done over Spherical or groin ceiling/ladao ceiling of domes. |
| 90 | Add extra for Lime plaster work done over curved/circular masonry work (curved or circular surface.) |
| 91 | Addextrafordecorative/ornamentalLimesurkhi1:2plasterworkwithfinefinishmakingkangoora,flowers,geometricaldesignsupto(khat)includingpreparationofLime surkhi mortar 1:2 as per tradititional practice Above 25mmand upto 40mm thick |
| 92 | Providing and laying lime Dhar on roofing as per Rajasthan, Jaipur traditional practice with lime, Surkhi, old lime powder, brick aggregate 12 to 20mm (1:2:2:2) and using Methi, Gur, Hemp, Belgiri etc. including beating and temping 100 to 150 mm thick as per specifications. Including dismantling of old deteriorated roofing |
| 93 | Providing & applying Lime kara 1:2 (1lime cream : 2 Zikki powder) grinding mortar with grinding mill/manually on lime base, on ceiling and all flat surface in two coats. First coat applying 3 mm to 4 mm thick and curing properly at least 7 days, second finishing coat done after 7 days of previous coat as per traditional practice.(thickness not more than 6 mm.) |
| 94 | Add extra for Lime Kara work (on lime plaster base) other than flat surface as per traditional practice with all lead & lift with fine finishing complete in all respect on :Curved surface. |
| 95 | Providing & applying Lime kara 1:2 (1lime cream : 2 Zikki powder) grinding mortar with grinding mill/manually (on lime surkhi/sand plaster base) on decorative/ornamental lime plaster in two coats.First coat applying 3mm to 4mm thick and curing properly at least 7 days,second finishing coat done after 7days of previous coat as per traditional practice.(thickness not more than 6 mm.) |
| 96 | Providing & applying \\"Lime Kara on stone work only\\" having carving stone work /decorative stone work (stone pillars, stone arches, railing etc.) as per traditional practice, as per specifications with grinded mortar in two coats with finishing complete in all respect. |
| 97 | Stucco work in lime, Surkhi, mortar (1:2) as per existing design work/ traditional practices by skilled craftsman, the stucco work should be done as per restoration nature, the mortar should be prepared by grinding mill adding gur, methi & gugal.. The thickness varies from 50 mm to 100mm as per the design (minimum rectangular surface area to be measured). |
| 98 | Khamira Colour Washing as per old traditional practice to prepare the Khamira the lime should be slaked at least for 7-10 days and regularly it should be stirred by adding cured, Gugal, for nonsynthetic colour adding gum (babool gum) as per specification. Then applying prepared solution on walls three to four thin coats as desired finishing. |
| 99 | Tuman masonry by brick bats/ stones in grinded mortar of Lime Surkhi mortar 1:2/lime sand mortar 1:2 including racking and removal of all old loose plaster and cleaning the wall surface properly as per direction of Engineer In-charge. |
| 100 | Painting on Stucco work with stone colours including base coat of khameera as per traditional practice (minimum rectangular to be measured). |
| 101 | Araish plaster (as per Jaipur practice) 1:2 ( 1 lime : 2 Zikki) on lime plaster or plane back ground including preparation of lime for 6 months by slaking of lime with curd and changing the water every week. The Kara plaster of not more than 6 mm thick is to be left the maximum of 3 months to appear the shrinkage & temperaturecracks. Over the Kara plaster 2mm layer of grinded lime putty is tobe done and is to be rubbed Gently by Akik stone. Then adding Khoppra & Ghee and inserting the design of colour boarder all round. |
| 102 | Coloured plain Araish work 1:2 (1 lime : 2 zikki) on lime plaster or plane back ground including preparation of lime for 6 months by slaking of lime with curd and changing the water every week. The Kara plaster of not more than 6mm thick is to be left the maximum of 3 months to appear the shrinkage & temperature cracks. Over the Kara plaster 2mm layer of grinded lime putty is to be done and is to be rubbed Gently by Akik stone. Then adding Khoppra & Ghee and inserting the design of colour boarder all round including desired colour stone pigment to match the existing colour. |
| 103 | Chemical treatment of sand stone to clean from yellowness, blackness, algal growth, dust, dirt oily accretions, lime & gypsum deposits, filling of cracks/ joining of gaps/ pointing, strengthening of weak stone, removal of salt effect and application of preservative coating to prevent algal growth and make the stone water proof. |
| 104 | Chemical treatment of araish surface to clean from yellowness, blackness, algal growth, dust, dirt oily accretions, lime & gypsum deposits, filling of gaps & cracks and application of preservative coating to prevent algal growth and make the surface water proof. |
| 105 | Site clearance by uprooting of trunk vegetation, bush, wood, trees and sapplings of girth upto 15cms and disposal of rubbish with in 50mtr. Including leveling and dressing of ground as per direction of Engineer incharge. |
| 106 | De-vegetation from monument by removing bushes, trees including complete uprooting from the wall & roofs/structures carefully including suitable chemical treatment to roots to avoid further growth including disposal of rubbish with in 50 mtr. Lead as per direction of Engineer in-charge. |
| 107 | Conservation of fresco paintings in monuments by cleaning of the painted surface from all types of stains, dust, dirt, greasy & oily accretions etc. with the help of suitable chemicals, removal of cracks, consolidation of flaking paint layer and plaster, filling of the lacunae in the plaster, treatment of salt effect and altered paint layer retouching of the lost portions and providing a preservative coating. |
| 108 | Conservation of oil paintings & portraits in monuments by cleaning of the painted surface from all types of stains, dust, dirt, greasy & oily accretions etc. with the help of suitable chemicals, removal of cracks and holes, consolidation of flaking paint layer and plaster, filling of the lacunae in the plaster, treatment of salt effect, retouching of the lost portions and providing a preservative coating. |
| 109 | Providing and fixing fine dressed 35mm to 40mm thick \\" flooring \\" with white/light pink sand stone (machine grinded surface) machine cut of approved shade set in pattern over 30mm thick base of lime surkhi mortar 1:2 including jointing finished flush with lime putty and stone powder with an admixture of pigment complete in all respect. |
| 110 | Providing and Fixing fine dressed sand stone /approved stone \\"Chajja\\" for palaces,chattries,forts and jharokas with fine dressed surface both sides and front edges should be round shape/moulding, fixing in grinded lime surkhi mortar 1:2 joint flush with proper adhesive with pigment to match the shade of stone (thickness of chajja on front edge 50mm and 75mm on fixing end) exposed surface is to be measured only. |
| 111 | Providing and fixing fine dressed sand stone \\"Todies\\" (Brackets) as per existing matching stone with moulding work with fine finishing , fixing in grinded lime surkhi mortar 1:2 including scaffolding, lead & lift complete in all respect.Size : 90cm X 60cm X 10cm (exposed part only.) |
| 112 | Providing and fixing fine dressed sand stone \\"Dasa/coping\\" as per existing matching , fixing in grinded lime surkhi mortar 1:2 including pointing in cream and stone powder 1:1 with an admixture of pigment to match the shade of stone complete in all respect.75mm to 100mm thick with pan patti design. |
| 113 | Providing and fixing double leaf door wooden shutters made of Ist grade wood as per trditional design (Deshi pattern) planks thickness 40mm and width of Binies, Andheri 50mm and 35mm, including Adwa etc. with fittings (nails, sankal, kunda, cheri, handle and patti etc.) as per existing matching/ as per approved design with moulding/ carving complete in all respect : Sheesham wood grade Ist |
| 114 | Providing and fixing double leaf Window wooden shutters made of Ist grade wood as per trditional design (Deshi pattern) planks thickness 25mm and width of Binies, Andheri 35mm and 25mm, including Adwa etc. with fittings (nails, sankal, kunda, cheri, handle and patti etc.) as per existing matching/ as per approved design with moulding/ carving complete in all respect : Sheesham wood grade Ist |
| 115 | Add extra for brass fittings inplace of M.S./ G.I fittings |
| 116 | for doors (deshi pattern double leaf shutters ) |
| 117 | for windows (deshi pattern double leaf window shutters ) |
| 118 | Providing & fixing ashlar \\"Rain water Spouts\\" (3) lines dressed as per traditional practice / existing design / approved design size 60 x 30 x 25 cm, fixing the rain water spout with lime surkhi mortar 1:2, with proper slope complete in all respect. |
| 119 | Making Bend -patta, Cornice, Gola & String course with katla stone and Lime surkhi mortar 1:2 (projected ) and finishing with grinded Lime surkhi mortar 1:2 including moulding/ design work as per existing matching at site complete in all respect. |
| 120 | Size 20cm X 10cm. |
| 121 | Size 15cm X 10cm. |
| 122 | Providing and laying of paver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement)M-35,60mm thick to be used in light traffic (Light traffic is defined as a daily traffic up to 150 commercial vehicles exceeding 30 KN laden weight, or an equivalent up to 0.5 million standard axles (MSA) for a design life of 20 years (A standard axle is defined as a single axle load of 81.6 KN) like pedestrian plazas, shopping complexes ramps, car parks, office driveways , housing colonies, office complexes, rural roads with low volume traffic, farm houses , beach sites, tourist resorts, local authority footways, residential roads, etc. Category A Denated units to key into each other on four faces zigzag shape as per IRC SP 63:2004 |
| 123 | Providing and Fixing fine dressed sand stone approved stone\\" Railing\\" as per existing design and matching with thambli,fixing of railing with proper adhesive /clips complete in all respect (thambli & clips paid seperately.)75 mm. thick with moulding/lining. |
| 124 | Providing and Fixing fine dressed sand stone /approved stone \\"Thambli\\" (katahara pillers including) kalash on top,fixing on dasa as per existing design for fixing of stone jalies/railings including making grooves as per required size.Size 150x150x750mm including kalash with moulding. |
| 125 | Crackfillinginmasonarywallswithgrindedmasaldar lime surkhi mortar 1:2 (adding gugal, gugal, methi, belgiri)includingcleaningthecrackproperlycomplete Crack thickness above 50mm and upto 100mm |
| 126 | Renewing wooden beams in roofs including making good the holes in walls and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to the dumping ground within 50 metres lead.Not exceeding 4.00 metres in length.Sal wood beams. |
| 127 | Renewing wooden battens in roofs, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to the dumping ground within 50 metres lead :Sal wood beams |
| 128 | Repair of existing lime dar on roof by dismantling of lime floor, removal and repairing of damaged wooden planks, wooden purlins etc. Placing lime concrete 125-150mm thick on wooden planks as per traditional practice and overlaying of ceramic tiles on roof in cement mortar. (Wooden beams, battens, planks to be paid extra) |
| 129 | Removing/ dismambering of disturbed stones of existing stone walls carefully by manual means and refixing of cut stones in place of dismambered one including all scaffolding and shuttering work. Outermost dimensions of refixed cut stones to be measured for payment purpose. |
| 130 | Dismantling of existing wooden damaged railing and P&F wooden railing made out of Ist grade teak seasoned wood as per existing traditional pattern, including balusters, hand rails 50-60mm thick , ht of railing 0.85m as per existing matching including applying of 3-4 coats of linseed oil on wooden members. |
| 131 | Providing and Fixing of Signage 1 as per the attached drawing. The work shall include excavation for foundation and laying of 100 mm thick PCC in 1:3:6 and Brick masonary in Foundation and plinth in cement mortar 1:4, with a 50 mm thick Bansi Bharpur stone at top for coping. Vertical Portion of the Signage to be built in sandblasted Bansi Pharpur stone of 100 mm thickness and a ashlar solid block pillars fully fine (3 lines) dressed Bansi Pharpur Stone. (As per Shape, design & proportions shown in enclosed photograph) specified in the drawing. All work shall be done as per specifications and satisfaction of authority As per attached photograph/Drawing |
| 132 | Providing and fixing of 3 leged White Marble Carving Garden Stone Bench with back support as per drawing with 500 mm foundation fixed in Base Concrete (ratio 1:3:6) of 300 mm thick PCC to its 3 legs , and a height bench will be 500 mm from ground level, inluding Excavation & P.C.C. and fixing work , size of bench will be 60\\"x18\\"15\\", Thickness of Bench will be 55 to 80 mm with seating capacity of 4 peoples including weight carring capacity of 300 kg at a time with edge molding and heritage carving at side and back rest as per design and drawing. Complete in all respect as per directed by Engineer In charge. (Photograph/ Drawing Attached) |
| 133 | Tour Taxi (i.e. Sedan type four wheeler- four seater)Jaipur to Murli manohar temple , Dwarika Gujrat and return including toll tax, driver expenses (Food, Night Stay, misc.) including GST and other misc. taxes and charges. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysSep 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender