Tender For Supply Installation Testing and Commissioning of 3 Nos. 600-650 Kva Diesel Generator Set To Replace Worn-Out, Condemned Dg Sets At Skims Soura
Tender Value
3.28 Crore
Estimated cost
Bid Submission
29 Aug 2026
0 days left
EMD
6.56 Lakhs
Bank guarantee accepted
Document Fee
17000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply Installation Testing and Commissioning of 3 Nos. 600-650 Kva Diesel Generator Set To Replace Worn-Out, Condemned Dg Sets At Skims Soura
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, testing & commissioning of DG Set of capacity 600-650 kVA with acoustic Enclosure (CPCB-IV) (Silent type) with full authority electronic engine & canopy of suitable size complete with alternator, water-cooled, self-starting with suitable coupling with alternator of 600 kVA or above capacity, 415V at 1500 RPM, 3-Phase, 4-wires, 50Hz, 0.8 Power Factor at 415V, Capable of taking 10% overloading for one hour in any 12 hours duration.a.) Supply, fixing of sound proof (silent type) canopy of suitable size for the above DG Set. The Job also includes loading, unloading and shifting from unloading site to the foundation of DG Set.b.) Common base frame Batteries, Leads and Stand Anti Vibration Mountings, Acoustic Enclosure Residential Silencer, Exhaust Below Assembly HardwareFirst Fill of Lubricating Oil and coolant.c.) Supply, installation, testing & commissioning of the equipments & materials as mentioned in the specification of D.G. Sets (as detailed in the Annexure - A attached) |
| 2 | Supply, installation, testing & commissioning of AMF Panel consisting of 1000A, 4 pole, 50 kA, ACBs (EDO Type) and all other allied items / accessories / protection etc. complete as required for commissiong for the Diesel Generator Set(s) |
| 3 | Construction Of RCC Beds for DG Sets |
| 4 | (a) Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed,All kinds of soil, Rate for a lead upto 50 meter beyond 1 m from cutting edge. e/w for 1 bed = 7m × 3.25m × 0.75m = 17.0625 cum for each Bed.For 3 Beds = 3 × 17.0625 cum = 51.1875 cum |
| 5 | b) Supply & laying of dry stone soling hand packed tightly in place including carraige from approved source. 7m × 3.25m × 1'= 1.86 cumFor 3 Beds = 3 × 7 Cum |
| 6 | Sand cushioningFor 3 Beds = 30 Cum |
| 7 | c) Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering (All works up to plinth level) 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 7m × 3.25m × 6''= 3.5 cumFor 3 Beds = 3 × 3.5 Cum = 10.5 Cum |
| 8 | d) Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size).7m × 3.25m × 3'6'' = 24.5 cum MINUS 0.3 cum Cut-Out section for cables.i.e., 24.5 - 0.3 = 24.2 cumFor 3 Beds = 3 × 24.2 Cum = 72.6 Cum |
| 9 | e) Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D Qty vide item (d) @ 35 kg/cum |
| 10 | f) Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns |
| 11 | Earthing |
| 12 | Earthing with copper earth plate 600 mm × 600 mm × 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. filled by CCM compound and salt as required. The Job includes providing, laying and fixing of 25 × 5 mm Copper strip to be laid from the earth plate (gas-welded with the plate) upto a height of 300 mm above the ground level, as per the instructions of the Engineer-in-charge. The pit is to be dug using borewell and covered with 10×10 inch manhole cover. |
| 13 | Supplying and laying 25 mm × 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm) |
| 14 | Providing and fixing of 25mm x 5mm Copper strip from earth points (on surface or recess) to the DG Set. The job includes with cost of PVC conduit of appropriate dia through which earthing strip is to be laid above the ground. |
| 15 | Earthing |
| 16 | Supply, testing, laying, connecting & commissioning of 800 sq. mm, 1.1kV grade, Single-core, Aluminium Conductor, XLPE Sheathed Armoured Cable (ISI Marked), including PVC tagging after every 5 metres. The Job includes providing and fixing of MS Clamps (for fixing of cables onto wall or as per instructions of the site engineer). The Job includes end-termination of spans of the cable at locations as per the instructions of the site engineer. |
| 17 | 800 sq. mm, 1-core |
| 18 | Providing and fixing M.V. Danger Plate of size 200mm × 150mm, made of mild steel, atleast 2mm thick and vitreo-use name led white on both sides and with inscription in single red colour on front side as required. |
| 19 | Cable Trays / Structures |
| 20 | Design, Supply, Fabrication and Erection of GI structure from channel / angle iron of suitable sizes to support the cable tray / ladder duly taking into consideration of the wind load/pressure at the site etc. including the cost of civil foundations as required. |
| 21 | Design, Supply, Fabrication and Erection of GI Structure from channel /angle iron/ Flat iron of suitable sizes for making Ladder along with extension to DG set foundation duly taking into consideration the wind load/pressure at the site etc. The Job includes the cost of civil foundations as required. |
| 22 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.I. Bolts & Nuts etc. as required. |
| 23 | 450 mm width × 50 mm depth × 2.0 mm thickness |
| 24 | 600 mm width × 50 mm depth × 2.0 mm thickness |
| 25 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.I. Bolts & Nuts etc. as required. |
| 26 | 450 mm width × 50 mm depth × 2.0 mm thickness |
| 27 | 600 mm width × 50 mm depth × 2.0 mm thickness |
| 28 | Supply, fixing, testing & commissioning of fuel pipe 1\\" dia for fuel supply from HSD oil reserve service tank to oil tank of the DG Set with providing/fixing covering of glass wool, chicken mesh and fixing aluminium sheet around the pipe. The job also includes providing ,fixing of union, elbow, socket, Tee, gate valve etc. as per site requirement Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender