Tender Document For Air Conditioner Work Of Ad, Ld And Reception At Nift Delhi Campus New Delhi
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, testing and commissioning (SITC) of Cassette type Split Air conditioner , 5 star of Nominal capacity between 3.8Tr to 4.3 tr with air cooled Outdoor condensing unit as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories (Cu), Refrigerant charges with R410a / R32 and safety devices like thermal protector, pressure relief valve, over load protector, single phase preventer, high-low pressure cut out, suitable with electrical power supply of 3 phase 415V . (Note : This work includes installation of AC after cutting and making of space in gypsum board false ceiling and making of holes in walls etc as per requirement for smooth functioning of AC and complete in all respect as per instruction of engineer -in -charge ) ( Make : Daikin/ Hitachi/Toshiba / Blue Star / LG/ Mitsubishi / voltas/ O General ) |
| 2 | Supply, installation, testing and commissioning (SITC) of Cassette type Split Air conditioner, 5 star of Nominal capacity between 1.2 Tr to 1.6 tr with air cooled Outdoor condensing unit as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories (Cu), Refrigerant charges with R410a / R32 and safety devices like thermal protector, pressure relief valve, over load protector, high-low pressure cut out, ( Note : This work includes installation of AC after cutting and making of space in gypsum board false ceiling and making of holes in walls etc as per requirement for smooth functioning of AC and complete in all respect as per instruction of engineer -in -charge ) ( Make : Daikin/ Hitachi/Toshiba / Blue Star / LG/ Mitsubishi / voltas/ O General ) |
| 3 | SITC of soft drawn copper piping (Make- Metube / Mandev / Campro/ Rajco) for refrigerant with NBR tubular insulation ( 9mm thick ) , covering with PVC tape, between indoor to outdoor unit of split AC suitable for 1.5 tr cassette AC and as per manufacturer recommendation for piping and as per direction of engineer -in-charge. Holes in the wall should be made from the hole cutting machine and repairing the surface after work including filling. plaster and paint etc, complete. |
| 4 | SITC of soft drawn copper piping (Make- Metube / Mandev / Campro/ Rajco) for refrigerant with NBR tubelar insulation ( 9mm thick ) , covering with PVC tape, between indoor to out door unit of split AC suitable for 4 tr cassette AC and as per manufacturer recommendation for piping and as per direction of engineer -in-charge. Holes in the wall should be made from the hole cutting machine and repairing the surface after work including filling. plaster and paint etc, complete. |
| 5 | P/F of PVC channel (Make- ML/ Legrand) 2 inch x 2 inch on the surface/ recess (wall/ceiling/ floor) for covering of copper piping as per direction of engineer -in-charge |
| 6 | P/F of PVC hard drawn condensate water drain piping (AKG or equivalent) of 25mm dia. With tubular insulation of 6 mm thick and necessary hardware like clamps and joints etc . for fixing of piping , as per direction of engineer -in-charge |
| 7 | P/F of Electrical wire 4 core x 1.5 sqmm (Make- Finolex/Havells / polycab/ RR /KEI) for connection between indoor to outdoor ( Round Triple layer PVC Insulated Flexible Copper wire as per IEC and ISI mark ) as per direction of engineer -in-charge |
| 8 | P/F of Electrical wire 4 core x 4 sqmm (Make- Finolex/Havells / polycab/ RR / KEI) for Main power supply connection to AC ( Round Triple layer PVC Insulated Flexible Copper wire as per IEC and ISI mark ) including PVC conduit and accessories as per direction of engineer -in-charge |
| 9 | P/F of Electrical wire 3 core x 2.5 sqmm (Make- Finolex/Havells / polycab/ RR / KEI) for Main power supply connection to AC ( Round Triple layer PVC Insulated Flexible Copper wire as per IEC and ISI mark ) including PVC conduit and accessories as per direction of engineer -in-charge |
| 10 | P/F of heavy-duty M S wall/floor stand for placing of outdoor unit as per direction of engineer -in-charge |
| 11 | Providing and fixing of suitable size floor mounted MS Angle iron stand (Angle size 40x 40x 4 mm) with painting for outdoor unit of 4 tr AC, compete in all respect and as per direction of Engineer-in-charge. |
| 12 | Providing and fixing of the DP MCB 32 A with box (Make- Havells/ Anchor/ LT/ Schneider Electric/ Siemens and Legrand) including connection, complete in al respect. |
| 13 | Providing and fixing of the TPN MCB 32 A with weather proof box (Make- Havells/ Anchor/ LT/ Schneider Electric/ Siemens and Legrand) including connection, complete in al respect. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysAug 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender