Tender For Providing And Fixing Ms Staircase From 3Rd Floor To 4Th Floor Of State Information Commission Building At Ip-8, Sector-3, Panchkula
Tender Value
16.45 Lakhs
Estimated cost
Bid Submission
13 Aug 2026
0 days left
EMD
17000
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Panchkula → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing And Fixing Ms Staircase From 3Rd Floor To 4Th Floor Of State Information Commission Building At Ip-8, Sector-3, Panchkula
BOQ
| Sl. No. | Item Description |
| 1 | SHEET ROOFING Providing and fixing UV stabilised fibreglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated `J` or `L` hooks, bolts and nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc.The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2. 2 mm thick flat HSR 9.32 |
| 2 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar HSR 5.7 |
| 3 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: 1. G.S. Sheet HSR 5.15 |
| 4 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.HSR 5.25 |
| 5 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. HSR 5.34 |
| 6 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1. For thickness of tiles 10 mm to 25 mm HSR 5.43 |
| 7 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. HSR 5.49 |
| 8 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.HSR 5.70 |
| 9 | CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR 11.5 |
| 10 | GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. HSR 10.50 |
| 11 | VITRIFIED FLOOR TILES Providing and fixing ceramic and Glazed tiles/ vitrified tiles/ of any size of approved make in floors / dados, laid in any pattern as specified over base of 3 mm thick adhesive of reputed brands as per IS specification 15477-2004 using 5 Kg. adhesive per sqm area of tiles and jointed with white cement slurry mixed with pigment to match the shade of tiles excluding cost of tiles. HSR 10.73 |
| 12 | SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 1. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete HSR13.29 |
| 13 | SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 2. Hot finished seamless type tubes HSR 13.30 |
| 14 | STAINLESS STEEL RAILING Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). HSR 13.41 |
| 15 | INTERIOR FINISHING Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete HSR 11.58 |
| 16 | INTERIOR FINISHING Applying priming coat: 3. With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works HSR 11.68 |
| 17 | INTERIOR FINISHING Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. 2. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre HSR11.69 |
| 18 | INTERIOR FINISHING Wall painting on a cement plaster surface with acrylic emulsion paint of approved brand and manufacture to give an even shade : 1. Two or more coats on new work HSR11.71 |
| 19 | INTERIOR FINISHING Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. HSR11.78 |
| 20 | EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR11.95 |
| 21 | B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR7.22 |
| 22 | SCAFFOLDING FOR REPAIR WORKS Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, up to 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal and vertical tubes joint with cup and lock system withM.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. HSR 30.94 |
| 23 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and submains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) HSR 23.5 |
| 24 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.2. Wiring main and submains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) HSR 23.5 |
| 25 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and submains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) HSR 23.5 |
| 26 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISImarked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.HSR 23.7 |
| 27 | MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.6. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 6 way ( 8 incoming 3phase*6 outgoing) HSR 23.22 |
| 28 | Supply and Fixing of Fire rated Doors of various sizes with 120 Minutes testing under BS:476 (Part-20 and 22) 1987 and IS:3614, (Part-2) 1992. Material of Construction is IGI sheet with Powder coating in desired RAL shade with shutter thickness 46mm and sheet thickness 1.2mm, frame thickness 1.2mm having with Rockwool as infill including all fire rated accessories such as Fire rated clear glass, SS hinges, door closer, panic bar, PHT lock, door seal, Flush bolt, dash fastner etc. The accessories should be GEZE make or equivalent |
| 29 | Providing and fixing of Anchor rod HIT-V-8.8 M20x250 to be embedded 170 mm with injectable mortar HIT-RE 500 V4/500 complete in all respect make (Hilti). |
| 30 | Providing and fixing of Anchor rod HIT-V-8.8 M16x210 to be embedded 150 mm with injectable mortar HIT-RE 500 V4/500 complete in all respect make (Hilti). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender