Tender For Providing Balance Works Of Electrical Installation, Fire Fighting System And Lift Installation At High Security Jail, District Rohtak.
Tender Value
1.90 Crore
Estimated cost
Bid Submission
17 Aug 2026
9 days left
EMD
3.80 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Rohtak → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Balance Works Of Electrical Installation, Fire Fighting System And Lift Installation At High Security Jail, District Rohtak.
BOQ
| Sl. No. | Item Description |
| 1 | HSR PART[11.46]Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 and II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls and ceiling at all floors and locations, finished in smooth line and level etc. complete. [Through Rate] |
| 2 | [20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) [Through Rate] |
| 3 | [23.33.2 (a).3]Online UPS- Input supply: Three Phase, Output supply: Three Phase:- Supplying, installation, Testing and Commissioning of of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 deg C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swappable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N plus 1 modules (N denotes total number of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch alongwith provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)`s both for the rectifier and inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant Inter- national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be )96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall be ( 5% at 50 %load. (The required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC : 3Phase 400V plus /-20%, 50 Hz plus /-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz plus /- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV surge.UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware and software for iOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accessories are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 and 3, IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED) to display : a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage. f)Temperature: STS, Inverter, PFC. g) Event Logging and Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. 3. 30KVA (Each Power module shall be <10 KVA) [Rate] |
| 4 | [23.5.6.5]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) [Through Rate] |
| 5 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] |
| 6 | [23.8.1.14]FITTING AND ACCESSORIES 1.14. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. telephone socket [Through Rate] |
| 7 | [24.13.48]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 48. 50 Sq mm 4 core (Arm.) [Through Rate] |
| 8 | [24.13.88]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 88. 240 Sq mm 3.5 core (Arm.) [Through Rate] |
| 9 | [24.5.2.1]MISCELLANEOUS ITEMS 2.1. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 40/32 mm outer dia/ inner dia [Through Rate] |
| 10 | [24.5.2.4]MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia [Through Rate] |
| 11 | [24.5.2.7]MISCELLANEOUS ITEMS 2.7. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 180/150 mm outer dia/ inner dia [Through Rate] |
| 12 | [25.3.6]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 6. 100mm dia. [Through Rate] |
| 13 | [25.3.7]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 7. 80mm dia. [Through Rate] |
| 14 | [36.1.8]Supplying, installation, testing and commissioning of Electric driven Main Fire Pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required:(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-12615: 2018.(d) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation duly plastered with anti vibration pads. 8. 2280 lpm at 70 M Head [THROUGH RATE] |
| 15 | [36.16.1]Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with Gl wire, rivets etc. conforming to IS 636 (type-A) as required: 1. Gun Metal [THROUGH RATE] |
| 16 | [36.17.1]Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.(a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type 2 as per IS: 12585(b) 20 mm nominal internal dia gun metal globe valve and nozzle.(c) Drum and brackets for fixing the equipmets on wall.(d) Connections from riser with 25 mm dia stop gun metal valve and M.S. Pipe and socket. 1. 30m [THROUGH RATE] |
| 17 | [36.18.1]Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneousconnection to interconnect hose pipe coupling as required: 1. Gun Metal [THROUGH RATE] |
| 18 | [36.19.1]Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 1. 2 way-100 mm dia M.S. Pipe [THROUGH RATE] |
| 19 | [36.19.2]Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 2. 4 way - 150 mm dia M.S. Pipe [THROUGH RATE] |
| 20 | [36.19.3]Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 3. 3 way - 150 mm dia M.S. Pipe. [THROUGH RATE] |
| 21 | [36.20]Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve withrequired accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. [THROUGH RATE] |
| 22 | [36.21.4]Providing, fixing, testing and commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 °C with required accessories: 4. Concealed sprinkler [THROUGH RATE] |
| 23 | [36.25.4]Supplying, installation, testing and commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 4. 1500mm [THROUGH RATE] |
| 24 | [36.30]Providing, fixing, testing and commissioning of ISI marked (ISI MARK 15683) portable CO2 fire extinguisher of capacity 4.5 kg including valve,horn,suitable handle, discharge hose of one meter long complete in all respect with explosive certificate . [THROUGH RATE] |
| 25 | [36.31]Providing, fixing, testing and commissioning of ISI marked (ISI MARK 15683) trolly type CO2 fire extinguisher of capacity 9 kg including valve,horn,suitable handle, discharge hose of one meter long complete in all respect with explosive certificate. [THROUGH RATE] |
| 26 | [36.35]Providing, fixing, testing and commissioning of ISI marked (ISI MARK 15683) portable ABC multipurpose filled by 90% (MAP) mono amonioum phosphate powders, nitrogen pressurised type fire extinguisher with meter, hose reel rubber pipe with 0.50 mtr long with capacity of 6 kg complete in all respect. [THROUGH RATE] |
| 27 | [36.52]Providing, fixing, testing and commissioning of Wall Mounted or Free Standing Type , Weather proof hose cabinet of size 750 x 600 x 250mm with glazed double door fabricated with MS sheet of 16 gauge to accumulate 2 nos. Delivery Hoses of 15m lenght and Branch Pipe complete in all respect. [THROUGH RATE] |
| 28 | [36.53]Providing, fixing, testing and commissioning of Wall Mounted or Free Standing Type , Weather proof hose cabinet of size 350x 300 x 250mm with glazed single door fabricated with MS sheet of 16 gauge to accumulate 1 no. Delivery Hose of 15m length and Branch Pipe complete in all respect. [THROUGH RATE] |
| 29 | [36.6.1]Providing laying, testing and commissioning of `C` class heavy duty MS Pipe conforming to IS 1239/Class -II of IS: 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation and providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 1. 200 mm. dia (wall thickness = 6.3 mm) [THROUGH RATE] |
| 30 | [36.6.2]Providing laying, testing and commissioning of `C` class heavy duty MS Pipe conforming to IS 1239/Class -II of IS: 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation and providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 2. 150 mm. Dia [THROUGH RATE] |
| 31 | [36.7.1]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 1. 25 mm dia [THROUGH RATE] |
| 32 | [36.7.2]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 2. 32 mm dia [THROUGH RATE] |
| 33 | [36.7.5]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 5. 65 mm dia [THROUGH RATE] |
| 34 | [36.7.6]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 6. 80 mm dia [THROUGH RATE] |
| 35 | [36.7.7]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 7. 100 mm dia [THROUGH RATE] |
| 36 | [36.9.1]Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless Steelcap and chain as required. 1. Single headed Stainless steel [THROUGH RATE] |
| 37 | [37.1.4a]Supplying, installation, Testing and commissioning of the passengerMachine Room less (MRL) lift having following main features:a) MOTOR : Gearless lift drive comprising of high starting torque liftduty, 3 phase 440 Volts A.C. permanent magnetic synchronous motor ofproper rating with high efficiency shall be used.b) Operation/Drive : Microprocessor based /PLC, AC VariableVoltage variable frequency variable speed (V3F) vector control drive withencoder feedback closed loop system shall be used for lift car and dooroperation which shall be full collective selective operation hall call demandresponse, UP/Down hall stops, main, Up/Down contactor with overload andphase reversal relay and safety controls.c) Traction Media: main hoist flat coated steel belt / rope. Thimblesof spring permit adjustment of uniform tension for smooth operation of theelevator Pulse belt monitoring system to avoid the cut in the belt.d) Car : car should be with M S platform with bracings of adequatesize and to sustain the impact load cabin plus passengers with safety factorof fire for steel with Anti-skid PVC flooring and side panels should be ofStainless steel with hair line finish of sheet of grade 304 duty with S.S.handrails . Car ceiling shall be steel finish with aesthetic appearances withLED ceiling lights .The size of the car shall be taken as per available lift wellsize and relevant BIS code of lifts. Car panel will also be of S S 304 gradefinished with emergency stop device, emergency alarm, mechanical doorsafety device, full length infra-red curtain in car door, facility ofauto/attended mode. All car panel buttons and all floor switches must bewith brail language as per lift act. Agency shall also provide and install oneNo. 2 MP , IR , IP based ceiling mounted Dome Camera in the car completewith connecting cables and accessories (To be connected with existing CCTVsystem in the Building) .The inspection unit shall be provided at the top ofthe car. e) Landing Doors: All landing door shall be fully automatic centeropening / telescopic made of hair line finish stainless steel grade 304 withkey holes and infrared curtains with unlocking facility from outside.f) Emergency light: Appropriate rechargeable battery operated LEDemergency light in the car and along with alarm switch shall be provided.g) ARD: Automatic rescue Device (ARD) shall be provided accordingto passenger capacity with SMF batteries of approved brands.h) Audio-Visual Indication: Audio visual indication in the lift car,showing over loading such that doors kept open till excess load is removed.i) Scrolling Indicators: Digital scrolling indicator system for up-downarrow with floor position indicator shall be provided inside the car and at allstops/floors.j) Buffers: Spring buffers/PU Buffers shall be provided.k) Car Fan: ENERGY EFFICIENT Car fan/blower with automaticsleep timer shall be provided.l) Voice Annunciator: Voice annunciator with suitable music shall beprovided in lift car.m) Self diagnostics system for operational and safety parametersshall be provided in control panel.n) Mechanical/Electronic over speed governor, door key holes in thefloor doors, fireman switch shall be provided.o) Permanent wiring in lift well with providing and fixing of electricaldistribution board complete with SP and TP MCB`s, proper numbers of lightpoints, with LED fixtures, exhaust fan, 2 nos copper plate /chemicalearthing with 8 SWG copper earth wire and plug points shall be provided by the agency. (Power supply of 3 phase 440 V shall be made available bydepartment in lift machine room.)p) Agency has to provide all working drawings and documents tocomply latest BIS specifications and make proper liaison services forobtaining all necessary permissions. 4a. 13 passengers/884 Kg, 3 stops, rated speed adjustable up to 1.5 mtr /sec with 2 years comprehensive maintenance / DLP. [Rate] |
| 38 | [6.16]Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate] |
| 39 | [6.30.15]Centering and shuttering including strutting, propping etc. and removal of form for 15. Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like [Through Rate] |
| 40 | [6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more [Through Rate] |
| 41 | [7.51]Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor IV level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately). [Through Rate] |
| 42 | NS PARTSupplying, installation, testing and commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 43 | Supply, installation, testing and commissioning of plug in type analogue addressable Multicriteria Detector (Heat cum Smoke) with soft addressing feature including the cost of base plate with twin LED for 360° view complete as per specification. |
| 44 | SITC of UL Certified Linear pneumatic Heat Detection Tube (ID-6mm and OD-8mm) for automatic fire detection and supperession system made by special modified polyamaide (PA), colour red RAL300, burst temperature 1310C, inner diameter 6mm, outer diameter 8mm. Pressurised with dry nitrogen at 15 bar pressure with all necessary fittings and supports. Certified by National Test House, Dept of Consumer Affairs, Govt. of India. |
| 45 | Supply, Installation, Testing and Commissioning of UL/FM Certified Extinguishing agent filled in PESO Approved Filling Station: 4 Kg FK-5-1-12 Clean agent filled in PESO approved stored pressure type seamless steel cylinder as per IS 7285 (life 15years) with automatic type DLP valve assembly PI marked, TPED (Transportable Pressure Equipment Directive) approved, Used Standards for type approvals ISO 17871:2015 in conjunction with EN ISO 10297:2014 EN ISO 14246: 2017-12, Push in connector, End of line adapter, UL listed Pr. Switch, end of line plug, T connector, Safety Burst Disc at 28 Bar and Mounting Bracket. Stored Pressure type fitted with Pressure gauge, UV Resistance, Operating Pressure 15 bar, Hydraulic Pressure Tested to 250 bar, Burst Pressure at 350 bar, Red Powder coated. Certified by National Test House, Dept of Consumer Affairs, Govt. of India. system design as per NFPA 2001 and Installed as per LPS 1666. |
| 46 | Supply, Installation, Testing and Commissioning of UL/FM Certified Extinguishing agent filled in PESO Approved Filling Station: 2 Kg FK-5-1-12 Clean agent filled in PESO approved stored pressure type seamless steel cylinder as per IS 7285 (life 15years) with automatic type DLP valve assembly PI marked, TPED (Transportable Pressure Equipment Directive) approved, Used Standards for type approvals ISO 17871:2015 in conjunction with EN ISO 10297:2014 EN ISO 14246: 2017-12, Push in connector, End of line adapter, UL listed Pr. Switch, end of line plug, T connector, Safety Burst Disc at 28 Bar and Mounting Bracket. Stored Pressure type fitted with Pressure gauge, UV Resistance, Operating Pressure 15 bar, Hydraulic Pressure Tested to 250 bar, Burst Pressure at 350 bar, Red Powder coated. Certified by National Test House, Dept of Consumer Affairs, Govt. of India. system design as per NFPA 2001 and Installed as per LPS 1666 |
| 47 | Supply, Installation, Testing and Commissioning of Master Control Unit inbuilt A/v alarm Control Panel along with sounder cum strobe of 24VDC operated red colour MS housing , 2 NO/NC potential free relay contact for Main Fire Alarm. Modbus for BMS Integration. Gas discharge led indicator, battery led indicator, system status Led indicator, AC power ON Led indicator. |
| 48 | Supply, Installation, Testing and Commissioning of 2 Core, 1.5sq mm Speaker Cable For Loudspeakers. complete in all respect up to the entire satisfaction of Engineer - in - charge of the work including making necessary connections etc. |
| 49 | SITC of Water mist and CAF (Compressed Air Cylinder) 50 Ltr Capacity Trolley Mounted Fire Extinguisher, Compressed Air Cylinder Material – Carbon Composite PET Liner Cylinder With Grapheme Nano Tube, Air Cylinder Capacity – 6.8 Ltr, Air Cylinder Pressure–300bar,Weight of fully charged Trolley mounted Fire Extinguisher–104kg. complete in all respect upto the entire satisfaction of the Engineer-in-charge of the work. |
| 50 | Microprocessor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the nonvolatile memory (EPROM), power supply unit (230 t 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel shall be compatible for BMS system with open protocol BAC net/ Modbus over IP complete as per specifications:Two Loop Panel |
| 51 | Supply and Erection of MS partly glazed single/double hung lockable shutter fabricated from MS section as required with 5 mm thick glass for fire station complete including stove enamelled painting of door and frame and words `Fire Hydrant` written on glass, suitable to accommodate 2 Hydrant landing valves, 1 fire hose reel, 2 nos.15m long 63 mm dia hose,1-branch pipe, 1no. fire man`s axe, fire extiguishers 2 nos, including suitably mounted on a raised masonry platform as required. (Approx.size 0.90 m x 2.1m ) |
| 52 | Supply and Erection of Double Extra Large Water Cooler Partial Steel Body with 150 Litres storage capacity with 2 nos of cold faucets Brass (Cr plated), Rotary compressor, condensing tube grooved cooper with Aluminium, Unit Dimensions (Wide X Deep X Height): 685 MM X 530 MM X 1365 MM, Chillier Tank: Stainless Steel (SS 304), Drip Tray: Stainless Steel (SS 304), Water Inlet and Outlet Hose pipe: Provided operation on single phase 230V AC Supply 50 Hz Frequency. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work. |
| 53 | Supply and Erection of 25 Litre Commercial RO Purifier, Installation Type Table Top, Wall Mounting, Fully automatic with auto cut off RO plus UV Water Purification system 25 Litre/ hr. capacity, with 7 stage smart water purification system, including components industrial filter cartridge, Auto flush, purification method Ultraviolet reverse osmosis system. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work. |
| 54 | PROVIDINGand ERECTION/ LAYING OF 35 SQMM 4 CORE PVC/ XLPE INSULATED COPPER CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK. |
| 55 | PROVIDINGand ERECTION/ LAYING OF 16 SQMM 4 CORE PVC/ XLPE INSULATED COPPER CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK. |
| 56 | Supply, installation, testing and commissioning of loop powered addressable Sounders cum flasher units compatible with the intelligent fire alarm system, designed to operate directly on the addressable loop without external power supply, having integral audible sounder (minimum 90–100 dB at 1 m) and high-intensity LED xenon/LED flasher for visual indication, with selectable tones and flash rates as per site requirement complete in all respect. |
| 57 | Supply and Erection 2 core 1.5 sqmm unarmored FRLS Fire alarm cable suitable for indoor fire detection and alarm system wiring, having annealed high-conductivity copper conductors, PVC insulated, twisted cores with colour coding, laid up and sheathed with Fire Retardant Low Smoke (FRLS) compound to minimize smoke emission and toxic fumes during fire conditions: the cable shall be rated for 1100 V grade complete in all respect. |
| 58 | Supply, installation, testing and commissioning voice alarm call station (fireman’s microphone console) suitable for emergency public address and voice evacuation systems, designed for manual paging and broadcast of live voice messages to selected zone complete in all respect. |
| 59 | Supply, installation, testing and commissioning 6 Watt RMS speaker suitable for fire alarm and voice evacuation/public address systems, having rated power output of 6 W RMS with provision for multiple wattage tapping (e.g., 6/3/1.5 W) through built-in line matching transformer, designed for 100 V line operation, delivering clear and intelligible sound with wide frequency response (approx. 100 Hz to 10 kHz) and sound pressure level adequate for indoor coverage: the speaker shall be ceiling/wall mount type as required complete in all respect. |
| 60 | Supply and Erection of Addressable Manual Call pull type BOX suitable for intelligent fire alarm systems, designed for manual initiation of fire alarm by pull down lever operation, with resettable mechanism using key (non-break glass type preferred) complete in all respect. |
| 61 | Supply, installation, testing and commissioning of standalone battery-operated photoelectric smoke detector complete with 9V/AA battery, built-in sounder of minimum 85 dB at 3 m, LED indication, low battery warning, test button, ABS flame-retardant housing, complying with EN 14604 or equivalent international standard, including all accessories required for satisfactory operation complete in all respect. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysAug 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender