Housing Urban and Rular Development Local Bodies Closing in 3 days TDR #56867290

Tender For Work No. 02: Construction Of A 2X5 Mva 33/11 Kv Electrical Substation And A 33 Kv Feeder Line At The Govind Vihar Residential Scheme.

Issued by Local Bodies · Mathura, Uttar Pradesh
Tender Value
5.46 Crore
Estimated cost
Bid Submission
05 Sep 2026
3 days left
EMD
10.93 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mathura → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Work No. 02: Construction Of A 2X5 Mva 33/11 Kv Electrical Substation And A 33 Kv Feeder Line At The Govind Vihar Residential Scheme.

BOQ

Name of Work:- xksfoUn fogkj vkoklh; ;kstuk esa 2 x 5 ,e-oh-,- 33@11 ds-oh- fo|qr lcLVsku ,oa 33 ds-oh- QhMj ykbu dk fuekZ.k dk;ZA
Sl. No. Item Description
1Excavation of trench of size (0.60x0.60x0.75 metre) S.I. no. 251.
2Supply laying & fixing of earthing mat of 32 mm dia M.S. rod including cartage, cutting, welding and binding etc.
3Supply/Fixing/Piling of 32 mm dia 3M. Long earth electrode vertically for earthing.
4Supply/laying of 50mmx6mm G.I. strip including cartage, cutting welding etc.
5Supply and burying of 40mm diax4.5 meters long G.I. pipe vertically for earthing having 12mm dia holes spaced 75 mm aprat drilled up to 2 metre from the bottom complete with earthing lead of no. 6 to 8 SWG GI wire in G.I. pipe up to appron (and form appron to switch board the cost of G.I.wire and pipe will be extra) up to switch board 30 cm square C.I. box with hinged cover masonary enclosure, funnel at top, altenate layers of charcoal/coke and salt ate least 150 mm thick alround etc. as per directions of E/I complete in all respects. as per drawing analysis based on PWDSOR 2018 (701)
6Supply and burying of 600mmx600mmx6.0 mm G.I. plate verically for earthing with its top at least 3 meters below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG G.I. wire in 15 mm dia G.I. pipe up to (switch board form appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30 cm square C.I. frame with hinged cover masonary housing alternate layers of charocal/coke and salt at least 150 mm thick alround etc as per directions of E/I complete in all respect. PWDSOR 2018 (702).
7Supply and buryig of water level earthing as per direction by E/I. (PSR)
8S/E of terminal gantry structure of M.S. channel joist 150mmx150mm, 8.5m long with 3.2m long sopport of same section. The gantry shall be grouted 1.8m below G.I. with 0.3m plinth above. G.I. in cement concrete (1:2:4) in foundation of size 2.20mmx0.190mmx1800 mm with plinth mounted on a stone pad of 300x300x75mm including earth excavation work filling making plinth of required height and with required fabrication as per drawing no. 1. complete in all respect as per direction of E/I.
9S/E of busbar gantry structure of M.S. channel 150x150mm 27.10 kg/m 6.40 m above the ground level and 1.20m below G.I. The gantry shall be grouted in 1:2:4 cement concrete foundation size 2000mmx1000mmx1800mm (including 300mm plinth above G.I.) mounted on stone pad of 300x300x75mm including earth excavation back filling making plinth of required height and with requird fabrication as per drawing no. 2 complete in all respect as per deirection of E/I.
10S/E of 33kv line isolator/bus isolator structure made of 125mmx65mm(10.7kg/m). Channel at a height of 2.5m. Above ground and 1m below ground on a cement concrete pad of 75m thick with 1:2:4 cement concrete foundation size 1000mmx900mmx1800mm including excavation back filling making plinth of required height and with required fabrication for obracing of M.S. flat 50x6mm, and top of M.S. angle size 75x75x8mm.
11S/E of steel structures for 33kv lighting arrestors/post insulater/CTs/DO fuse sets and for MOCBs made of M.S. channel 100x50mm, 7.9kg/m. top of M.S. angle 50x50x6mm, 4.5kg/mtrs lighting arrestors/post insulators are to be mounted on M.S. plate of 200x150x8mm. Height of structure to be 2.5m above ground and 1m below ground on 1.75mm thick cement concrete pad with 1:4:8 cement concrete foundation making plinth of required height including all fabrication as per drawing and as per direction of E/I.
12Supply & fixing of 33 KV/800 A main linc/bus type isolator of all necessary material required for proper fixing on structure including all labour, material T&P etc. required for proper completion of the work.
13Supply/fixing of 33 Kv lighting arrestor of approved quality and make with necessary material required for vising on structure including all labour, material T&P etc. required for proper completion of the work.
14S/F of 33 kv DO fuse set 200 Amp. Verical mounting complete with isolator.
15Supply, Installation and Commissioning of ABB/Crompton Greaves/Alsthom/ Equivalent make 33 kv online OHB medium VCB voltage type circuit breaker for outdoor 1250 A, 1500 MVA, 25 KA, Motorized (220 V AC) closing 4 Tripping coil 24 V DC as per direction of E/I.
16Supply Installation and Commissioning of control panel indoor type for VCB circuit breaker 600mmx1800mm with indicator IDMT relay over current relay, earth fault realy, voltage meter Amp. With selector switches, power factor meter, hooter heating pad etc all complete. make ABB, Crompton Greaves, Alsthom.
17Supply and installation of 33 KV current transformer (CT), outdoor, epoxy cast, minimum oil filled, burdenn, 15 VA, class 0.5/1.0 or 5P10 for metreing & protection etc. all complete CTR-10, 20, 25/5-5A or 1-1A. Crompton make or equvalent.
18Supply and installation of 33 Kv potential transformer (PT) outdoor epoxy cast, Impregnated minimun oil filled. Single phase PTR 33 KV/3/110/3 Burden 100/50/10 VA, class 10/05. Crompton make or equvalent.
19Supply Installation and Commissioning of Crompton Greaves/bicco Lawrie/ALSTHOM/equivalent make manually operated (Incoming) 11 Kv, 3 phase, 3 wire, 50 cycles, effectively earthed, 800Amp., 350 MVA, fault level VCB Vacuum circuit breaker all steel totally enclosed, fully interlocked, indoor industrial pattern, metal clad, verically insulation, Horizontal draw out, floor mounting , Main bus bar & earth bus bar shall be of aluminium. HT Switch board equipped with Fabricated Sheet Steel Housing- 1 No. Mechanical Interlocks- 1 Set. 800 Amp. Single Pole, Isolating Plugs sockets - 6 Nos. 631 Amp. Triple Pole, Circuit Breaker fitted with spring assisted manually closing tripping mechanism with mechancial ON/OFF indicator suitable for rupturing capacity of 350 MVA at 11 KV & containing 1-3 phase, 3 class- 1 PT with drawable type, air cooled, CTs ratio 600/300/5 Amp. having accuracy class- 1 for metering & protection including Red, Green & White indicating lamps for breaker ON/OFF/TRIP & Circuit healthy. 1 No. Triple Pole IDMT relay having two over current & one earth fault element CDG- 61 High Set instanteneous standby earth fault relay. 1 No. Strip heater. 1 No. Amp. Meter with Selector Switch 1 No. Volt Meter with Selector Switch. 1 No.24 VDC Shunt strip coil. 1 No. KWH meter with MDI. 1 No. Power factor meter. 1 No. Hooter
20Supply Installation and Commissioning of Crompton Greaves/bieen lawrie/ALSTHOM/equivalent make manually operated (outgoing)11 KV, 3 phase, 3 wire, 50 eyeles, effectively earthed, 800Amp. 350 MVA, fault level vacuum circuit breaker all steel totally enclose, fully interlocked, indoor industrial pattern, metal clad, vertically insulation, Horizontal draw out, floor mounting, main bus bar & earth bus bar shall be of aluminium, HT switch board equipped with : Fabricated Sheet Steel Housing- 1 No. Mechanical Interlocks- 1 Set. 800 Amp. Single Pole, Isolating Plugs sockets - 6 Nos. 631 Amp. Triple Pole, Circuit Breaker fitted with spring assisted manually closing tripping mechanism with mechancial ON/OFF indicator suitable for rupturing capacity of 350 MVA at 11 KV & containing 1-3 phase, 3 limb 11000/110 volt burden 100 VA per ph. air cooled, CTs ratio 200/100/5 AMps having accuracy class-1 for metering & protection including red, green & white indicating lamps for breakrer ON/OFF/TRIP & circuit healthy. 1 No. Triple Pole IDMT relay having two over current & one earth fault element CDG- 61 High Set instanteneous standby earth fault relay. 1 No. Strip heater. 1 No. Amp. Meter with Selector Switch. 1 No. 24 VDC shunt strip coil. 1 No. Power factor meter. 1 No. Hooter. 1 No.auxillary relay for OTI alarm & strip. 2 No. auxillary relay for WTI alarm & Trip. 3 No. auxillary relay for buchhloz alarm & trip.
21Supply Installation and Commissioning of Crompton Greaves/Bisco lawire/equivalent make manually operated (outgoing)11 KV bus coupler, 3 phase, 3 wire, 50 cycles, effectively earthed, 800 Amp. 350 MVA, fault level vacuum circuit breaker all steel totally enclose, fully interlocked, indoor industrial pattern, metal clad, vertically insulation, horizontal draw out, floor mounting. Main bus bar & earth bus bar shall be of aluminium. HT switch board equipped with Aluminium, HT switch board equipped with Fabricated Sheet Steel Housing- 1 No. Mechanical Interlocks- 2 Set. Automatic safety shutters 3- sets. 800 Amp. Single Pole, Isolating Plugs sockets - 6 Nos. 630 Amp Triple Pole, Circuit breaker fitted with spring assisted manually closing tripping mechanism with mechanical ON/OFF indicator suitable for rupturing capcity of 350 MVA at 11 KV & containing. Red, green, white indicating lamps for breaker ON/OFF/ Trip & circuit healthy. 1 No. rear cable box. 1 No. strip heater. Installation & Errection.
22Supply, Installation and commissioning of 11 KV VCB capacitar bank .
23Construction of transformer plinth 3.5x2.5mx0.75 meter size with E/w P.C.C. in 1:4:8, R.C.C. in 1:2:4, Brick work in 1:6 filling with local sand plastering, with M.S. iron two no rail 105 LBS 3 met long as per direction by E/I.
24Supply, Installation, Commmissioning & Testing of battery charger 24V 24V/40 Amp float cum boost battery charger with dropping diodes suitable for I/P 230V±10% 1 Phase, 50 Hz Type FCBC as per DVVNL Specification, maximum continuous output ratings (outpur voltage in float mode 25.80 Volts and in Boost mode upto 33.0 Volts), output crrrent 40V, plus trickle charging current of battery floatmode 20A (Max), Boostmode 20A Load terminal, 20A, Battery terminal 20A, Starting rate 10A upto 2.35 V per cell, Finishing rate 10A upto 2.75 V per cell, Output ripple 1% PP at full load and 25.8V DC, output regulation (floatmode) ±1% for ±10% supply voltage fluctuation and ±10% to 100% load variation, Automatic/manual mode of operation, Automatic and manual terminal charging, control configuration I-Phase full wave controlled, thyristor bridge feed through I-phase transformer and controlled by constant current /protential controller with load liminting feature and integrated non compartmentalized DCDB with 01 No 60A MCCB incomer, 5 Nos 16AMCB, sheet thickness 2mm, protectin as per IS: 13947) IP-42/ maximum Permissible input volage ±10% of 230V AC, Electronic protection with auto reset against short circuit and overload, DC over voltage short circuit at charger output terminals, thyristor by fuseing with protection against over charging, efficiency of rectified >65% at rated load, Power factor 0.7 lag at D.C Current 230V Input with ANC cooling type and Class F type insulation. For Battery: 240V/200AH Tubular type battery bank consisting 12 Cells of each 2V/200 AH dry & uncharged along with wooden stand & accessories.(Analysis No.- 21)
25Supply and laying of following type high conductivity aluminum stranged compacted circular condutor XLPE (E) armoured 11 KV cable \\"HAVELLS, NICCO CCI\\" or equivalent make neutral earthed system confirming to IS 7098- Part-II (1985) with latest amendment at a depth of 1 mt. below ground level over a cushion of 75 mm thick sand around and protected with brick on sides and top of cables shall be properly connecting with the earth conductor by clamps etc. with the cost of all material. labour T&P etc. required for proper completion of the work. (i) 240 sqmm 3 core
26(ii) 400 sqmm 3 core
27Supply/ fixing and jointing of 240 sqmm outdoor type 11 KV jointing kit push on type on type for 11 KV cable including cost of all material labour, T&P etc. for proper completion of the E/I.
28Supply/ fixing and jointing of 400 sqmm outdoor type 11 KV jointing kit push on type on type for 11 KV cable including cost of all material labour, T&P etc. for proper completion of the E/I.
29supply/fixing and jointing of 240 sqmm indoor type 11 KV jointing kit push on type for 11 KV cable including cost of all material labour, T&P etc. for proper completion of the E/I.
30Supply/fixing and jointing of 400 sqmm indoor type 11 KV jointing kit push on type for 11 KV cable including cost of all material labour, T&P etc. for proper completion of the E/I.
31Supplyand fixing of Cu lugs for XLPE cable S.I. No. 503 (O, Y & T) (ii) 240 sqmm
32(iii) 400 sqmm
33Supply and Errection of Double Pole comprising of 2 Nos. 410 SP-55 Steel tubular Pole including 3 Nos. 100x50mm MS channel 2.24 M long and 1 No. 75x40mm MS channel 2.24 M long, clamps, packing pieces etc duly painted complete in all respect as per direction and approval of Engineer-in-charge. As per bond to (Jublipark)
34Supply and erection of stay set at least 3.5 metres away from the pole complete with galvanised 19mm dia. x 1.800 metre long stay rod, 30cm x 30cmx6.3 mm anchor plat, thimble stay clamps, stay insulator. 19mm x 600mm double serew tightener, 7/4.00mm G.I. stay wire etc. in 1:3:6 cement concrete in all respects. (PWD SOR 2018 Si. No.-630)
35S/F of 11 KV DO Fuse set insulators and fuse mounts with material & labour etc. complete in all respect as per direction and approval of Engineer-in-charge.
36S/F of 11 KV TPMO switches 3 pole hand operated single break without earthing contact plate and suitable for vertical mounting and double pole/four pole structure with material & labour etc. complete in all respect as per direction and approval of Engineer-in-charge.
37S/F of 11 Lightening Arrester with line side terminal connectors suitable for vertical as well as horizontal entry of conductor. The base of Lightening Arrester shall be short circuited through a GI strip size 35mmx5mm or of equivalent cross section. complete in all respect as per direction and approval of Engineer-in-charge.
38Supply of 11/0.44 KV, 63KVA copper wouned type tested transformer duly apporved by D.V.V.N.L., mathura.
39Supply and laying, installation , testing & commissioning of out door type with off load tap changer, 05 MVA Power Transformer as per ISI specification including loading, unloading, local carriage & erection of the same on plinth & making all necessary connection etc. as per direction of E/I. approved in D.V.V.N.L. type tested. a- Cable termination box with disconnecting facility for 33 KV XLPE calbe at 33 KV. b- Cable termination box with diconnecting facility for 33 KV XLPE cable at 11 KV . c- Off load tap changer +/ -7.5 @ 2.5 % d- Bi directional roller. e- Conservator with drain valve. f- Earthing terminals. g- Double diaphragm explosion vent. h- Radiator with top & bottom shut off valve. i- First filling of oil including make up fill. j- Silica gel breather with oil seal. k- Rating and diagram plate. l- Air release plug. m- Buchholz relay with shut off valve. n- Winding temperature indicator (WTI)o- Oil Temperature indicator(OTI). p- Megenatic oil level guage. q- Pressure relief device. r- Marshalling box (Analysis No- 13)
40Supply and laying of armoured control cable for equipment. 6 Sqmm 2 Core
414 Sqmm 3 Core
426 Sqmm 9 Core
4310 Sqmm 12 Core
44Supply and laying of D.W.C. HDPE pipe size 200/170
45Construction of control cable duct/trench of required size in messonarey brick work in 1:3 with plaster size (2x1x0.35x0.3+2x1x0.23x0.45) with plaster 4 D.P.C in 2 Cm thick.
46Supply and laying of 150 mm dia G.I. pipe complete with clamp for supporting of cables.
47Supply and filling & laying of 20 mm stone grit in yard of size 21x42 mtr x 0.10 mtr thick complete in all respects.
48S/L of 1800x900x12 mm. thick chequered rubber matting of testing quality.
49Supply and fixing of co type fire extinguisher, 4.50 Kg. capacity (ISI Mark) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. SOR 2018 Si no. 1132
50Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 33 volts grade at a depth of 750 mm bleow ground level over a cushion of 75 mm. Thick sand all aroundand protected with burnt bricks on sides and on top. On surface th cable run shall be fixed on M.S. clamps etc. of suitable size or as directed byh the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.400 sqmm 3 core XLPE 33 KV - HT Cable
51S/F end box out door type for 33 KVA 3 core 400 sqmm cable XLPE
52S/F of P.G. clamp
53S/F of packing piece
54Supply fixing and installation of FRP transfermar cage complete with brick work plaster etc. as per direction Engineer incharge and UPPCCL specification.
55Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket ( 1 Mtr length ) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.SOR 2018 SI. No. 641
56Supply and laying of 16 sqmm 4 core aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PWD SOR 2018 S.I. No. 501-I
57Supply and intallation of L. E. D street light fitting having die cast aluminium body and diffuser with driver set suitable for 90 watt confirming to IP-66 protection complete in all respects . PWD SOR 2018 S.I. NO. 1423 CAT-AAA 8250-9900 system lumens, high power LED with lenses, 1101 M/W, PF > 0.95, THD < 10% at Full load CRI> 70, Potted driver site (Not Circuitory) Phase to phase protection at 440 Volt & > 300 Volt auto cut & restart Feature with Five years Warrantee. SOR 2018 Si No. 1423
58SITC of 12,65 kV, 3960 kVAr, 3-Phase, 50 C/s housed in Outdoor Type CRCA Panel, Capacitor bank having two variable step of 792 Kvar & two Variable steps of 1188 kVAr. Bank shall be complete with Capacitor units of 396/264 kVAr, Aluminium busbars, Pin & Post insulators, HRC fuses, Surge arrestor etc.with deta ils as follows. ( I ) II kV, Aluminium Wound, Dry type Series reactors a) 0.52 kVAr for 792 kVAr step - 6 Nos. , b) 0.8 kVAr for 1188 kVAr step - 6 Nos. (2) I I kV, 3-Phase Dry Type RVT - I No. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Capacitor switches. - 4 Nos. (4) Indoor Type Automatic Control Unit - I No.(5) IP 55 , Outdoor CRCA cubicle Panel for accommodating capacitors, Series Reactor, Vacuum contactor, Surge arrestor & Fuses etc., along with FRP Canopy- I set. 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.9 kV, 10 kA,Station Class, Lightning Arrestors Control cables, lugthimble, Junction Box etc. Adopter panel for connecting capacitor VCB with exisiting bus, Casting of Civil foundations For Penal, Cable trench for laying of power/control cables, Supply & erection of Modem with ACU box foe communication Setting up communication with ACU (max 25 Banks connectivity ) to Executive Engineer offices (SIM card shall be provided by DVVNL
59supply, installatiol and commissioning of 33kv control and relay panel with differential relay ( single transformer), 2 element auxilliary relay for transformer fault, 100w with space heater with thermostat , toggle switch for heater on-off, 5 amp, cubicle illumination lamp 40w, door limit switch, power plug socket with control switch, alarm bell, alarm buzzer, auxilliary relay with 2 chnageover contact 24v dc, auxilliary relay with 2 changeover contact 230v ac, cable gland as per requirement, complete in all respect as per direction E/I.
60Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. DSR 2018 Si. no. 14.15.1. 63 mm dia HDPE Pipe for protection of street light cable
61supply and installation of Single Pole structure on STP 13.0 Mtr for single ckt 33KV line. Complete in all respect as per direction of E/I.
62supply and istallation of Extra T-off channel 125x65x1600 mm. with clamp. Complete in all respect as per direction of E/I.
63Supply and installation of Extra 33 KV Stay set. Complete in all respect as per direction of E/I.
64Supply and errection of ACSR Dog Conductor. Complete in all respect as per direction of E/I.
65Tree cutting compensation.Complete in all respect as per direction of E/I.
66Supply and installation of Guarding of 33KV line . Complete in all respect as per direction of E/I.
67Supply and installation of Extra cost of Stud pole PCC 9 Mtr. Long. Complete in all respect as per direction of E/I.
68Supply and installation of Extra cost of Stud pole STP 11 Mtr. Long. Complete in all respect as per direction of E/I.
69Supply and installation of HT Connection. Complete in all respect as per direction of E/I.
70Supply and installation of PG clamp for Dog Conductor. Complete in all respect as per direction of E/I.
71Supply and installation of M+6 Tower Galvanised Type up to 2400 Kg. Complete in all respect as per direction of E/I.
72Supply and installation of Top Channel 125x65x6x3200 sqmm. Complete in all respect as per direction of E/I.
73Supply and installation of 33 KV Disc Insulators B&S Type 7000 Kg. Complete in all respect as per direction of E/I.
74Supply and installation of Disc Fittings for Dog/Raccoon 7000 Kg. Complete in all respect as per direction of E/I.
75Supply and installation of 33 KV Pin Insulator. Complete in all respect as per direction of E/I.
76Supply and installation of 33 KV Pin with nut. Complete in all respect as per direction of E/I.
77Supply and installation of Chemical Earthing Complete. Complete in all respect as per direction of E/I.
78Supply and installation of Nut & bolt. Complete in all respect as per direction of E/I.
79Supply and installation of Pointer Barbed Protection for Tower. Complete in all respect as per direction of E/I.
80Supply and installation of Cable Route Marker. Complete in all respect as per direction of E/I.
81Supply and installationof G.I. Pipe 160 mm Dia. Complete in all respect as per direction of E/I.
82Supply and installation of G.I. Pipe Holding Clamp. Complete in all respect as per direction of E/I. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56867290
AUTHORITY Local Bodies
TENDER VALUE 5.46 Crore
LAST DATE 05-09-2026
Authority
Authority Name Mathura Vrindavan Development Authority
Work Description Tender For Work No. 02: Construction Of A 2X5 Mva 33/11 Kv Electrical Substation And A 33 Kv Feeder Line At The Govind Vihar Residential Scheme.
Basic Detail
Tender No 19/MVDA/2026-27
Bidding Type Tender
Location
City Mathura
State Uttar Pradesh
Key Dates
Publish Date 06 Aug 2026
Submission Date 05 Sep 2026
Open Date 07 Sep 2026
Finance
Tender Value 5.46 Crore
Tender Fee 5900
EMD 10.93 Lakhs
Exemption Not Available
Document List
65c74932-5174-4d42-9c03-42565901a4cc.html
BOQ_2207973.xls
TD19.pdf
Tendernotice_1 (30).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Sep 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

65c74932-5174-4d42-9c03-42565901a4cc.html

xls

BOQ_2207973.xls

pdf

TD19.pdf

pdf

Tendernotice_1 (30).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders