Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #56866268

Tender For Special Repairs To Building No. Np-63 And Provision Of Retaining Wall Near Bldg No Np-63 Under Ge (South) Udh Ur

Issued by Statutory Bodies & Commissions/Committees · Reasi, Jammu and Kashmir
Tender Value
1.08 Crore
Estimated cost
Bid Submission
02 Sep 2026
16 days left
EMD
1.84 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Reasi → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Special Repairs To Building No. Np-63 And Provision Of Retaining Wall Near Bldg No Np-63 Under Ge (South) Udh Ur

BOQ

Name of Work:- SPL REPAIRS TO BLDG NO. NP-63 AND PROVISION OF RETAINING WALL NEAR BLDG NO NP-63 UNDER GE (SOUTH) UDH UR
Sl. No. Item Description
1BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER, UDHAMPUR Name of Work: SPL REPAIRS TO BLDG NO. NP-63 AND PROVISION OF RETAINING WALL NEAR BLDG NO NP-63 UNDER GE (SOUTH) UDHAMPUR Contract No: CWE/U(S)- 61/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words
2Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
3Non skid, coloured ceramic jointfree/rectified tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed.
4Glazed coloured ceramic jointfree/rectified tiles300mm x 600mm x 7 mm on vertical surfaces of walls as in dado/skirting etc., set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including 10 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed.
5Dark shade Vitrified tiles 8-10 mm thick (square/ rectangular) polished, area of each tiles n exc 0.42 sqm but n exc 1 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of existing surfaces over and joints grounted with expoxy compound and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and as directed.
6Dark shade Vitrified tiles 8-10mm on vertical surfaces as in skirting over and including 10 mm thick rendering as backing coat to receive the tiles on fair faces of brick /concrete surfaces in cement mortar 1:3 and finished even and rough complete all as specified and directed.
7Dark shade Vitrified ceramic tiles 1800x1200x (8 to 10) mm thick (square /rectangular) polished area in floors etc over 15mm thick screed bed in cement mortor 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match and joints grouted with epoxy compound complete all as specified and as directed.
8All as per item No 6 above but in skirting over (8 to 10) mm thick back coat in cement mortar 1:3 complete all as specified and directed.
9Digital glossy Light shade double charged vitrified tile 8-10 mm thick (Square / rectangular) polished, area of each tiles not exc 0.36 Sqm, in floors ect set and jointed in neat cement slurry and pointed in coloured cement to match over 15 mm thick screed bed or beddding layer in cementy mortar 1:6 complete all as specified and as directed.
10Digital glossy Light shade double charged vitrified tile 8-10 mm thick (Square / rectangular) polished, area of each tiles not exc 0.36 Sqm, in vertical surfaces as in skirting ect set and jointed in neat cement slurry and pointed in coloured cement to match over 10 mm thick screed bed or beddding layer in cementy mortar 1:4 complete all as specified and as directed.
11Vitrified Dura stone tiles of size not exc 0.36 Sqm of 10mm thick as in floors and over & including 15mm thick screed bed or bedding layer in cement mortar 1:4, including jointed with neat cement slurry and pointed in coloured cement to match the surface of tiles, complete all as specified and directed
12Heavy duty step stone vitrified stair tile (of any type) work (table rubbed and polished) of size 1500x300x (10-12) mm in steps, jambs, pillars, ect over 15mm thick screed bed in cement mortar (1:4) set and jointed with neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
13Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and as directed.
14Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed.
15Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified.
16Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed.
17Rolled mild steel in roof trusses (framed) , trussed , purlins,crane gantries , rails and fastening and heavy bracket framing ( beam, tee, angle, channel or flat section) including distance pieces conforming to Fe 410-W, Gde E-250 Quality 'A', complete all as specified and as directed.
18Stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where everrequired) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, complete all as specified and as directed.
19Welded steel wire fabric mesh weight not exceeding 4 Kgs per sqm fixed to wood or steel members complete all as specified and directed.
20Dismantling wall and ceiling boards (fibre pulp, insulation etc) or insulation boards / slabs / blankets, any thickness, including cover fillets, complete all as specified and as directed.
21Providing and fixing Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre.
22Supply and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat or curved surface over GI frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately) Note: Design of POP ceiling will be as approved by GE.
23Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples as in windows and POP ceiling work, complete all as specified and as directed.
24Preparation of new seamless ceiling surfaces and applying two coats of oil bound distemper white tinted with roller application over a coat of chalk whitening primer over 3mm thick wall care putty complete all as specified and as directed.
25Material and labour for suspended flase ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600mm x 600mm with main runer 38mm x 24mm and wall angle 24mm x 24mm using 4mm thick high pressure Non Asbestos Fiber cement decorative Board (E-Board Classic) in a grid of GI system duly suspended with 4 mm dia GI bar hanger fixed with steel desh fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be interlocked between main runners @ 610mm c/c, as to from 600mm x 600mm grid all as specified and directed.
26Soild PVC wall lining consisting of 5mm thick good quality woodgrain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame incl PVC sheet fillet of width 35mm complete all as specified and as directed.
27Providing, Plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregates) in roof kerbs or mud stops, rounded or chamfered on edges, including mixing Liquid water proofing compund in the proprotion as mentioned in manufacturer's instructions complete all as specified and as directed.Note : Water proofing compund to be measured and paid for separately as supply only.
28Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 15mm thick screeding in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately). Applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3.50 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm, complete all as specified and as directed.Note :- Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency/applicator which will further have to rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise..
29Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation/Bushes (like peeple tree etc) scrubbing down with water complete, all as specified and as directed.
30M&L for rendering 15mm thick plaster in CM 1:4 mixed with WPC as per manufactures instructions in two layer (10mm+5mm). in patches in cement mortar in 1:4 on smooth face of brick work or concrete surfaces finishd even and smooth without using extra cement & with using integral water proofing compound.Note: Liquid Water Proofing will be measured and paid separately.
3110mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement, complete all as specified and as directed.
32Supply only water proofing compound complete, all as specified and as directed.
33Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including primingcoat of exterior primer applied @ 0.90 litre/ 10sqm over a coat of wall care putty over new/old surfaces complete all as specified and as directed.
34Preparation of new seamless wall surfaces and applying two coats of oil bound distemper white tinted with roller application over a coat of chalk whitening primer over 1mm thick wall care putty complete all as specified and as directed.
35Complete removal of existing treatmen and applying two coats of oil bound distemper white tinted with roller application over a coat of chalk whitening primer over 1mm thick wall care putty complete all as specified and as directed.
36Preparation of Old plastered finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm over 1mm thick wall care putty complete all as specified and as directed.
37Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified.
38Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed.
39Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortor 1:4 complete all as specified and as directed.
40Taking down chowkhat or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 Sqm each including cutting holes for taking out hold fasts, dismantling brick work (holes cut and any other damages to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost) complete all as specified and directed.
41All as per ser item No 42 above but exceeding 1.50 Sqm and not exceeding 4.00 Sqm complete all as specified and directed.
42Dismantling and re-fixing of the mobile storage compactor, including disassembly, careful removal from existing floor tracks, transportation, reinstallation at the new location with proper alignment and leveling, and final testing of the locking mechanism complete all as specified and as directed.
432nd class hard wood (SAL/Hollock) glazed and skelton shutters 35 mm thick open rebated and prepared to receive glass, guage etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Pt-I Section 8.24(a) supplied and fitted to chowkhats complete all as specified and directed.
44Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed.
45Flush shutters 30 mm thick , solid core construction, with block board core and plywood face panels, commercial type on both sides and both face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed. Note:- (i) Teak/Walnut veneer and satin lacquered finish plus brass trim. (ii) All edges shall be sealed with hardwood lipping or PU sealer with polish.
461mm thick wood grain printed Sunmica/ PVC sheet (Design as approved by Engr in charge) fixed or laid on to flush doors by using rubber based adhesive, supplying & fixing at site as per specification all as specified & directed.
47Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm Prelam PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specification & drawing as per specification & drawing, complete all as specified and as directed.
48Stainless steel cold rolled butt hinges medium weight 100 mm long fixed to pressed steel door frame if required complete all as specified and directed.
49Supply and fix in 150mm long stainless steel tower bolts, fixed in screws complete all as specified and as directed.
50S&F in stainless steel door handle, 250 mm size length complete all as specified and as dircected.
51300 mm long stainless steel sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of stainless steel complete, all as specified and as directed.
52Supply and fix of SS 304 mortise lock with handle set for 35mm thick flush shutter door, including cutting, chiseling, screws and all hardware complete all as specified and as directed.
53Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
54Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
55Aluminium (Die cast) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and as directed.
56S&F 12mm toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes, 18\\" SS handle, locking system etc as required complete all as specified and as directed.
57S & F 8mm thick Toughned glass (one side view) as in windows, partitions automatic doors and similar work including cutting to shape, drilling holes required, complete all as specified and as directed.
58S & F 6mm thick Toughned glass (tinted glass one side view) as in windows, partitions automatic doors and similar work including cutting to shape, drilling holes required, complete all as specified and as directed.
594mm thick figured glass (frosted) ,pin head type and glazing with oil putty not exc 0.50 Sqm in each pane fixing to window/ventilator complete all as specified and as directed.
60Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel staples complete, all as specified and directed.
61Drapery rod of 25 mm dia stainless steel 304 grade along with brackets and end caps of quality as appproved by GE. complete all as specified and as directed.
62Venetian blinds of approved make, vertical type using 100mm wide fabric blinds of approved colour/ shade and pattern including operating arrangement such as chord/ thread, counter weight, connecting chain etc., and necessary fittings complete all as specified and directed.
63S&F in repairs 5 mm thick looking mirror of required size, fixed on walls with dash fasteners and chromium plated screws purposefully made to fix the glass by drilling hole in the glass complete all as directed.
64Aluminium sheeting, Alloy 31000 H4l, 0.56mm thick plain, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) complete all as specified and as directed.
65Rotational moulded polyethylene water storage tank , three layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 1000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm (Minimum weight 210 gram) etc), incl dismantling existing water tanks, complete all as specified and as directed.
66Bib taps , fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm fixing in repair, complete all as specified and as directed.
67Stop valves/Angle valve, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, fixed in repairs, complete all as specified and as directed.
68Pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm, fixing in repair, complete all as specified and as directed.
69Gun metal globe of gate valve with iron wheel head, screwed both ends of size 20mm, fixed in repair complete all as specified and as directed.
70S&F in repair CP Soap dish in repair complete all as specified and directed.
71S&F Toilet paper holder, flat recessed type stainless steel complete all as specified and directed.
72Health faucet ABS body with wall hook and 1 mtr chrome plated PVC hose pipe, fixed in repairs, complete all as specified and as directed.
73Waste coupling of PTMT for 32mm dia discharge pipe (half or full threaded) (Minimum weight 32mm 45gms/ 40mm-60 gms), fixed in repairs, complete all as specified and as directed..
74Tubular towel rails brass chromium plated, 20 mm dia, D type, 60 cm long between flanges, fixed with rawl plugs fixed in repairs complete alll as specified and as directed.
75Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified & directed.
76Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed.
77Taking up or down steel tubing of 20 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed.
7815mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and ceiling or laid under floors etc complete all as specified and as directed.
7920mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and ceiling or laid under floors etc complete all as specified and as directed.
80PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
811200mmx600mm beveled edge mirror 5.5mm thick of selected quality glass, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, fixing in repair, complete all as specified and as directed.
82Viterous china wash basin, white flat back size 650 x 420 x 110mm including waste coupling CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia, fixed in repairs, complete all as specified and as directed.
83Vitreous China urinals, half stall (back or corner wall type) white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe), fixed in repairs, complete all as specified and directed.
84S&F in repair one pieace EWC with including soft closing seat cover colour white with S Trap/P Trap, wall distance 220/300mm including all accessories complete all as specified and as directed.
85110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified & directed.
8675mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified & directed.
8775mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed.
88PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement, complete all as specified.
8975mm bore PVC SWR bends any radius with access door and fixed solvent etc complete all specified and as directed.
90110mm bore PVC SWR bends any radius with access door and fixed solvent etc complete all specified and as directed.
91PVC (SWR) floor trap 75mm size, plain with grating including jointing with solvent cement fixing in repairs, complete all as specified and as directed.
92PVC (SWR) vent cowl of size 110mm bore, complete all as specified.
93Taking down eaves gutters and and rain water pipes (any size or pattern ), including all fittings incl removal of store and sold to contractor through credit.
94110mm bore, PVC (SWR) pipes, pressure rating 4 kg/sqcm, single or double socketed, in any length with rubber ring joints, fixed to wall with clamps, complete all as specified and as directed.
9518/19mm thickblock board, grade 2 quality, interior grade, Commercial type fixed in the aluminium shutter frame, cupboard shelves etc complete all as specified & directed.
960.9 mm thick decorative laminate type -1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions all as specified and directed.
97Magnet catchers with 50mm steel plate MS body and striking plate including letting in and fixed complete all as specified and as directed.
98100 mm Brass handles, cast type, polished bright complete all as specified and as directed.
99Demolition of cement concrete in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed.
100Providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (not exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints through out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
101Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 ( 1 cement : 2 coarse sand ) to match the existing floor complete all as specified and as directed.
102Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
103Preparation of new wooden surfaces over 10 cms width or girth and applying two coat of synthetic enamel paint by spray gun over one coat of pink primer complete all as specified and directed.
104Preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified and as directed.
105Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, and for laying of cable or pipes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil, complete all as specified and as directed.
106Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil,complete all as specified and as directed.
107Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed.
108Demolition and breaking up drain pipes, 150mm internal dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and as directed.
109Plain cement concrete bed to drain pipes in cement concrete 1:3:6 type C-2 of 150mm bore including packing under, and hunching against the sides of pipes after are laid and tested complete all as specified & directed. Note:- (i) Thickness of bed below barrel of pipe-10Cms.(ii) width of bed-outer dia of pipe plus 30 cms.
110Reinforced concrete pipes 150mm bore ,class NP3,laid and jointed complete with coller all as specified and as directed.
111Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified.
112Brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:6 but except bricks all complete all as specified and as directed.
11315mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4, finish surfaces even and smooth without using extra cement, complete all as specified and as directed.
114TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and including binding with MS wire (annealed not less than 0.9mm dia), complete all as specified and as directed.
115Precast RCC (1:2:4) type B-1, using 20mm graded crushed stone aggregate as in cover slab (for manhole etc), landing chullah hoods, chajjas, water troughs, mangers, sheleves and similar articles with plain faces complete set in cement mortar (1:4), complete all as specified and directed.
116Excavating over area, not exceeding 1.5 m depth; for foundation, etc. and getting out in any type of soil, complete all as specified and as directed.
117Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in foundation, filling and mass concrete, complete all as specified and as directed.
118Walling of random rubble stone masonry uncoursed, with best quality locally available stones, well bonded, bedded and solidly hearted , built in cement mortar 1:6 complete all as specified and as directed.
119Precast cement concrete 1:2:4 type B1 using 20mm graded crushed stone agregate bonders for stone walling set in cement mortar 1:6 with plain fair faces including chamfers weathering etc complete all as specified and as directed.
120M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed.
121Extra over stone walling of granite, trap or basalt stone for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses with maximum depression on face from straight edge held against the dressed surface n exc 40mm, complete all as specified & directed.
122Hand packing (any thickness) using broken stone or boulders at back of walls over arches etc., and raising (or lowering) to the required level, complete all as specified.
123Raised pointing to random or polygonal rubble stone or RR masonry, uncoursed or brought upto courses, in cement mortar 1:4 complete all as specified and as directed. Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56866268
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1.08 Crore
LAST DATE 02-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repairs To Building No. Np-63 And Provision Of Retaining Wall Near Bldg No Np-63 Under Ge (South) Udh Ur
Basic Detail
Tender No CWE/U(S)-61/2026-27
Bidding Type Tender
Location
City Reasi
State Jammu and Kashmir
Key Dates
Publish Date 05 Aug 2026
Submission Date 02 Sep 2026
Open Date 04 Sep 2026
Finance
Tender Value 1.08 Crore
Tender Fee 1000
EMD 1.84 Lakhs
Exemption Not Available
Document List
309ef701-3e32-4898-a175-facde2efb968.html
BOQ_877091.xls
Tenderdocuments.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Sep 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

309ef701-3e32-4898-a175-facde2efb968.html

xls

BOQ_877091.xls

pdf

Tenderdocuments.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders