Tender For maintenance and repair To Mbp; Annual Maintenance Contract For Maintenance Of Fire Hydrant System With Fire Pump And Maintenance Of Fire Alarm System
Tender Value
38.37 Lakhs
Estimated cost
Bid Submission
20 Aug 2026
11 days left
EMD
38400
Bank guarantee accepted
Document Fee
10030
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thane → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for maintenance and repair To Mbp; Annual Maintenance Contract For Maintenance Of Fire Hydrant System With Fire Pump And Maintenance Of Fire Alarm System
BOQ
| Sl. No. | Item Description |
| 1 | Repairs / upgradation of existing Fire hydrant system & fire alarm system. |
| 2 | Supplying and erecting 12 V/7Ah -7.5Ah SMF battery with battery terminal wire, duly charged complete with 12 months warranty complete |
| 3 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 4 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 5 | Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 6 | Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 7 | Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 8 | Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 9 | Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 10 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 11 | Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 12 | Supplying gun metal double outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 13 | Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 14 | Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) alongwith necessary accessories complete as per specification no. FF-FFA/HV |
| 15 | Supplying and erecting 63mm dia, controlled percolation (C.P.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/CPH |
| 16 | Supplying and erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FF-FFA/NZ |
| 17 | Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC |
| 18 | Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FMC |
| 19 | Supplying, erecting testing and commissioning Optical Type Smoke Detector on suitable back box with necessary connections complete as per specification no. FF-FAS/SD |
| 20 | Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR |
| 21 | Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \\"Break Glass\\" massage embedded on the glass, complete erected with mounting base and required accessories, Module shall conform to EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FF-AFAS/MCP. |
| 22 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 23 | Carrying out core cutting of size 3\\" to 5\\" dia x 15\\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. |
| 24 | Making trench in Hard murum/Tar road having 0.75m depth and minimum 0.3m width for laying provided cables up to voltage level 1.1kV cable complete as per specification no. CW-EXN-CTR |
| 25 | PCC / RCC for Road Crossing. |
| 26 | Supply & Installation of Structural Steel support for Pipe line, Supports etc. |
| 27 | Supply & installation of PVC blank cap with chain to suit existing hydrant valve. |
| 28 | Supply & installation of Ring Washer, Spindle Washer & servicing of hydrant valve. |
| 29 | Repairing & Servicing of Main Electrical Panel of Fire Fighting System. The Scope including repairing /replacemen of Selector Switch, Indicator Lamps,Contactor, Timer, Overload Relay etc as per site condition. |
| 30 | Varnishing of Jockey / booster pump motor of fire fighting system and servicing of pump & motor including changing of bearing, bushing, oil seal, rubber packing, etc. as per requirement. The scope of work including dismantling of existing pump & motor and re-installation of the same as per site condition. |
| 31 | Varnishing of hydrant main fire pump motor of fire fighting system and servicing of pump & motor including changing of bearing, bushing, oil, seal, rubber packing, etc. as per requirement. The scope of work including dismantling of existing pump & motor and re-installation of the same as per site condition. |
| 32 | Repairing and commissioning of existing diesel engine fire pump. |
| 33 | Supply & Installation of Single Door Hose Box. |
| 34 | Supply of diesel for day to day maintenance and operation of diesel Engine driven pumps including transportation. |
| 35 | AMC for Maintenance of Fire Hydrant System & Fire Alarm System |
| 36 | Annual maintenance contract for the work of 'Fire Hydrant System with Fire Pump' consist of provision for skilled technical staff, semi skilled / unskilled workers if required, electrician, plumber, including day to day maintenance; entire maintenance of Fire pump, maintenance of electrical panels, relays, electrical motors; Providing field testing and giving demonstration by every 15 days to allottees in the park; running of Fire pump every saturday minimum 1 Hr.; maintenance of Fire Hydrant, wet risers, including their other accessories like sluice valve; maintenance of electrical data history sheets including every type of maintenance in the fire hydrant system including jocky pumps / booster pumps including safety, security, insurance etc. complete. The agency has to maintain the Fire Hydrant System of total 19 buildings. The item is excluding all the maintenance material & spare parts required for the above mentioned works and machinaries . The same shall be paid saperately if required. |
| 37 | Annual maintenance contract for the maintenance of fire alarm system provided in the buildings including regular checking, deployment of fire safety engineer along with skilled technicians, supervision includes report of systems function conditions, maintenance of smoke detector, Repairing of existing Fire Alarm Panel fixing of new fire extinguisher as per requirment , demonstration of safety measures to be adopted for prevention of fire & use of fire hydrants in case of fire etc once in a week etc. complete. The agency has to maintain the Fire Alarm System of total 9 buildings. The item also includes round the clock for monitoring of fire system. The agency has to monitor & take appropriate action immediately during any fire hazard including buildings mentioned in item No.1. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysAug 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender