Housing Urban and Rular Development Government Departments Closing in 4 days TDR #56864094

Tender For Replacement Of Underground Cable , Led Fittings Of Existing High Mast And Other Allied Works At Skv Pooth Kalan Sports Complex, Delhi.

Issued by Government Departments · Delhi, Delhi
Tender Value
23.37 Lakhs
Estimated cost
Bid Submission
12 Aug 2026
4 days left
EMD
46754
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Replacement Of Underground Cable , Led Fittings Of Existing High Mast And Other Allied Works At Skv Pooth Kalan Sports Complex, Delhi.

BOQ

Name of Work:- Replacement of underground cable , LED fittings of Existing High Mast and other allied works at SKV Pooth Kalan Sports Complex, Delhi.
Sl. No. Item Description
1Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).350 Watt
2Supply of one number PVC insulated and PVC sheathed / XLPE aluminium Conductor armoured power cable of 1.1 kV grade of following size etc. as required.3x4 sqmm
34x25 sqmm
4Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in existing trench complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
5Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
6Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
7Providing boring by trenchless technology with no dig method by making bore hole in horizontal direction across the road as per direction of Engineer-in-charge with moling equipment i/c jointing cleaning, rodding of pipe providing suitable covers on mouth of pipes, excavation of pits of required size at a following depth i/c refilling etc. complete as reqd.0.75 Mtr to 1.5 Mtr. depth.
8Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as requiredUpto 35 sq. mm (clamped with 1mm thick saddle)
9Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sqmm
10Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
11Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
12Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
13Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
14Supplying and fixing of following capacity 240/415 Volts, ‘C’ series, Miniature Circuit Breaker (MCB) suitable for lighting and other loads of following poles in the existing MCB DB, complete with connections, testing and commissioning etc. as required63 Amp TPN MCB
15Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requiredSingle pole
16Repairing of existing high mast upto 16 metre height with help of tower wagon i/c providing and fixing of winch assembly i/c suitable size Electric motor for operation , 6 Sqm twisted SS wire from top to Bottom i/c replacement of nuts and bolts and greasing i/c testing commissioning complete etc as required. (Dismantled shall be credit to contractor)
17Fabrication, Designing, Supplying & Fixing of hot dip Galvanized arm bracket of suitable length single/double over hang having minimum 30 cm to 50 cm length with tightening bolt etc. (Design approved by Engineer-in- Charge).
18Less credit for Old dismantle of following items:-Copper/alumimium wire cut pieces assorted size
19Al. conductor armoured/unarmoured power cable assorted size
20Existing nonfunctional LED Fittings (150 to 250 Watt) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56864094
AUTHORITY Government Departments
TENDER VALUE 23.37 Lakhs
LAST DATE 12-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Replacement Of Underground Cable , Led Fittings Of Existing High Mast And Other Allied Works At Skv Pooth Kalan Sports Complex, Delhi.
Basic Detail
Tender No 13/EE(E)/NED/PWD/M-352/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 05 Aug 2026
Submission Date 12 Aug 2026
Open Date 12 Aug 2026
Finance
Tender Value 23.37 Lakhs
Tender Fee Ref. Documents
EMD 46754
Exemption Available
Document List
BOQ_394760.xls
e391cee0-5832-4c55-8883-556912ec0a07.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_394760.xls

html

e391cee0-5832-4c55-8883-556912ec0a07.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders