Tender For Provision Of Rain Water Harvesting At Pctc And Provision Of Radiation Protection Tiles For Ortho Pantomogram (Opg) X-Ray Machine Room At Mdc Under Ge (North) Bangalore
Tender Overview
Project Description
Tender for Provision Of Rain Water Harvesting At Pctc And Provision Of Radiation Protection Tiles For Ortho Pantomogram (Opg) X-Ray Machine Room At Mdc Under Ge (North) Bangalore
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Aug-2026 | 8374Corrigendum | BOQ | 20-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavating over areas n exe 1.50m deep in hard and dense soil and getting out complete all as specified and as directed |
| 2 | Excavation in trenches not exceeding 1.5 m depth and not exceeding 1.5m width and getting out in hard/dense soil for laying of pipe lines. |
| 3 | Excavating over areas exe 1.50m deep and n exe 3.00m in hard and dense soil and getting out complete all as specified and as directed |
| 4 | Excavating Excavating over areas, Exc 3.0m but not exc 4.50 mtr deep and getting out in hard / dese soil etc complete all as specified and as directed |
| 5 | Excavating Excavating over areas, Exc 4.50m but not exc 6.00 mtr deep and getting out in hard / dese soil etc complete all as specified and as directed |
| 6 | Returning filling in hard/dense soil, incl spreading, levelling, watering and well ramming in layers n.exc 25cm, complete. |
| 7 | Removing excavated soil exc 1.50 KM and n.exc 5 KM and depositing where directed at a level n.exc 1.50 M above the starting points all as specified. |
| 8 | M&L for PCC 1:2:4, type B2 using 40mm graded stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed. |
| 9 | M&L M-30 Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete |
| 10 | Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter all as specified and as directed by engineer in charge. |
| 11 | Material & Labour for RCC M30 grade concrete (Design Mix -using 20mm graded stone aggregate) as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses |
| 12 | Use and waste formwork to flat faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses |
| 13 | M&L for Reinforced cement concrete M-30 (desing mix) with using 20 mm graded stone aggregates as in slab supported on walls, beam and columns in floors, roofs landing balconies canopies etc complete all as specified and as directed |
| 14 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) with Rough finished surfaces of concrete (Flat) etc complete all as specified and as directed |
| 15 | M&L for Reinforced cement concrete (M-30) Design Mix with using 20 mm graded stone aggregates as in beam, cantilevers, bressumers, lintels over 1.5 mtr span etc complete all as specified and as directed |
| 16 | M&L for formwork to sides and soffits of floor or roof beam, beam and haunching, girders, bressummers, lintels cantilevers, shelves including supports, overhangs etc also splays between floor and beam with rough finished etc complete all as specified and as directed |
| 17 | Material and Labour for TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally or hoping for columns, hooking ends & binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips. |
| 18 | Material and Labour for TMT bars 6 TO 8 mm dia mm dia cut to length bent to shape required including cranking bending spirally or hoping for columns, hooking ends & binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips. |
| 19 | All as per item No 18 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and as directed |
| 20 | M&L for Pre-cast cement concrete block masonry, Type C1 1:3:6 (20 mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in mortar 1:4 , complete etc complete all as specified and as directed |
| 21 | M&L for cement concrete 1:2:4 type, B1 using 20 mm graded stone aggregates as in copings, Chajja kerbs, roof padding/staging of water tank etc including necessary fromwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed |
| 22 | M&L for rendering 10 mm thick in CM (1:4) on fair faces of brick work or concrete surface finished even and smooth without using extra cement etc complete all as specified and as directed |
| 23 | M&L for coarse sand of required size as in filling in rain water harvesting pit etc complete all as specified and as directed. |
| 24 | M&L for broken stone or boulder in loose filling with aggregates of gauge 40 mm to 80 mm size as in filling in rain water harvesting pit etc complete all as specified and as directed. |
| 25 | M&L for broken stone or boulder in loose filling with aggregates of gauge 80 to 150 mm size as in filling in rain water harvesting pit etc complete all as specified and as directed. |
| 26 | M&L for Rendering 5 mm thick in CM 1:3 mixed with WPC as per manufactures instructions on fair faces of concrete surface finished even and smooth all as specified and as dircted. Note - WPC will be paid and measured seperately. |
| 27 | Supply only water proofing compound (Liquid) complete all as specified and as directed. |
| 28 | M&L for 75 mm thick PCC 1:3:6, type C-1, using 20 mm graded aggregates as in plinth protection etc, finished even and smooth without using extra cement complete all as specified including joints filling with sealing compound Grade \\"A\\" complete all as specified and directed. |
| 29 | M&L for brocken stone or boulders of hardcore of gauge n exc 63 mm deposited, spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface. |
| 30 | Material and Labour for laying Reinforced concrete pipes, 300 mm dia class NP2, laid and jointed complete with collars complete all as specified and directed |
| 31 | Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in concrete bed to drain pipes including packing under and haunching against the sides of pipes of 300 mm bore after they are laid and tested . |
| 32 | M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:6 complete all as specified and directed. |
| 33 | S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel |
| 34 | Material and labour for 5 mm thick PVC ribbed water bar 200 mm wide as in construction joint etc complete all as specified and as directed |
| 35 | M&L for preperation of new steel surfaces of any description over 10 cm in width or girth and apply two coats of synthetic enamel paint over one coat of redoxide primer complete all as specified and as directed |
| 36 | M&L for Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 2000 litres hoisted and fixed in position all as specified in SSR Part Iincluding tank nipple incl 25 mm dia of bore ball float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic etc complete all as specified and directed |
| 37 | S & F 25 mm gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and including taking down old gate valve all as specified and as directed. |
| 38 | S & F 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified. |
| 39 | S & F 25mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors i complete all as specified. |
| 40 | S&F 150mm PVC (SWR) pipes, single socketed in any length with rubber rings joint fixed with wall complete all as specified and directed |
| 41 | S&F PVC (SWR) bends (any radius) with access door of 150mm dia. |
| 42 | M&L for charcoal filling in filter bed complete all as specified and directed. |
| 43 | Supplying laying and testing in trenches walls/ ceiling/floor polypropylene Random Copolymer (PP-R) (PN -16/SDR 7.4)-3 layers pipes with and including PP-R fittings such as bends, Elbow, Tee, short length,Socket, Union, Check Nuts, Nipples etc. (Females/Males as required), suitable for hot cold water supply line icluding making good disturbed surfaces/ cutting chassis in CM 1:3 and including testing complete all as per manufacture's instruction and as directed by Engineer-in Charge. Make SFMC WETFLOW / SAFE (Manufactured by poineer). following sizes 50 mm outer dia |
| 44 | S & F Poypropylene Random Copolymer (PP-R) Gate Valves of 50 mm dia with chromium plated working part Make (SMFC) |
| 45 | Supply & fixing gun metal Gate valve 25 mm dia with iron wheel. |
| 46 | S&F GI water tubing medium grade of 25mm dia with all fitting (flanged / socket / union / tee etc) laid in trenches / walls / floors / roof |
| 47 | All as per item No. 46 above but for50mm dia |
| 48 | M & L for contrsuction of brick masonary valve chamber of internal dimension 900 x 900 x 1000 mm in built CM 1:6 with MS cover 3 mm thick and locking arrangement incl excavation and earth work PCC 1:4:8 type D-2 for Idn, PCC beds/copying in cement concrete 1:2:4 type B-1, plastering 15mm thick in Cm 1:4along with MS cover plate and painting two coats of black bituminiours black paints over a coat of red oxide primer all as specified and as directed. |
| 49 | Boring of holes under road, pavement, hard standing by trenchless techless using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia bore suitable for 0.4 mpa working pressure. |
| 50 | M&L for PCC 1:3:6 type C1 with 20mm graded stone aggregate for couping of pole,filling and mass concrete of pole, hard standing etc incl necessary form work all as specified and as directed |
| 51 | S&F Foot Valve conforming to IS 4038, 50 mm (2”) dia. |
| 52 | S&F and testing Monoblock pump set suitable for 415 V ,3 phase system having capacity 5 HP including DOL starter and all fitting nut bolts flanch, tee, socket foundation etc all as specified and directed by engineer-in-Charge . |
| 53 | S&F brass non return valve 50 mm dia internal threded type complete all as specified and as directed. |
| 54 | M & L for sand cushioning with a layer of M-sand 23 cm thick under and above the cable complete all as specified and as directed |
| 55 | S & L sub class burnt bricks for cable protection complete as specified as directed |
| 56 | Supply, testing and commissioning in replacement of weather and vermin proof LT feeder pillar box factory fabricated outdoor cubical/kiosk type CPRI approved and confirming to IS 5036 totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly with powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar for phase & neutral 100 Amps,16 KA capacity and IP 54 protection mounted on epoxy insulator-01 Set including mounting the panel board on ground with PCC 1 :3:6 bedding upto a height of 50 cm above ground level and the size of feeder should not less than 150x130x 45 cm. complete all as directed and comprising the following. (i) Incoming MCCB 4 pole, 63 Amps 16 KA 415 Volts -01 No (ii) Outgoing MCB TPN 40 Amps 10 KA 415 Volts -02. No (iii) DOL starter for monoblocpump of capacity 5 HP - 02 Nos (iv) Digital Voltmeter 0-500 volts with selector switch - 01 No (v) Digital Amps meter CT operated 0-400 Amps with phase selector switch - 01 Nos (vi) LED Indicator lamp ( RYB ) - 01 Set (03 Nos) (vii) Single Phase Preventer |
| 57 | Supply and laying XLPE cable of 4C X 16Sqmm insulated screened PVC bedded galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable legs including necessary. |
| 58 | Taking down cement plaster of any description hacking for key or raking out joint on old brick work/stone/concrete surface etc complete all as specified and as directed |
| 59 | M&L Radiation Shield ceramic coloured tiles 300 x 300 x 12mm thick as in skirting/ dado, set and jointed in neat cement slurry and pointed in white or colour cement to match including backing coat 10 mm thick cement mortar (1:3) including dismantling existing wall tiling etc complete all as specified and as directed. (Note : Tiles shall be recommended by Atomic energy regulatory board) |
| 60 | M&L for complete removal of existing treatment of walls surface and applying two coats distemper oil emulsion, white or tinted over a coat of primer etc complete all as specified and as directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 6 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender