Defence Statutory Bodies & Commissions/Committees Closing in 7 days TDR #56863215

Tender For Special Repairs To Building No. 556 Smu At Naval Dockyard, Visakhapatnam Under Ge (I) Dm Visakhapatnam

Issued by Statutory Bodies & Commissions/Committees · Visakhapatanam, Andhra Pradesh
Tender Value
2.95 Crore
Estimated cost
Bid Submission
02 Sep 2026
7 days left
EMD
3.70 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Building No. 556 Smu At Naval Dockyard, Visakhapatnam Under Ge (I) Dm Visakhapatnam

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 20-Aug-2026 Corrigendum 01 BOQ 02-Sep-2026

BOQ

Name of Work:- SPECIAL REPAIRS TO BUILDING NO. 556 SMU AT NAVAL DOCKYARD, VISAKHAPATNAM UNDER GE (I) DM VISAKHAPATNAM
Sl. No. Item Description
1[SCHEDULE 'A' PART-I [B/R WORKS]
2Demolition of textile covering and including all padding concrete over RCC slab over roof, including removal of waste material away from Dockyard premises complete all as specified and directed.
3M&L for providing, cement concrete type B1 1:2:4 (Using 20mm graded stone aggregate) as in roof padding concrete and kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
4M&L for 10mm thick screed bed over padding concrete cement mortar 1:4 with water proofing compound as per manufacture instructions by weight of cement and finish the surface even and smooth with out using extra cement all as specified and directed.Note :- Supply only WPC will be measured and paid separately.
5M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per Sqm including cleaning of surfaces all as specified and directed.
6M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) shall be laid over entire roof surface and on vertical surface up to groves with other laps of 100mm. The over lap shall be sealed by flames complete all as specified and directed.
7Taking down Chowkats or frames not exceeding 1.5 Sqm each (Without taking off shutters from the frame) and removing away from site complete all as specified and directed.
8Taking down Chowkats or frames exceeding 1.5 Sqm but n exc 4.00 Sqm each (Without taking off shutters from the frame) and removing away from site complete all as specified and directed.
9S&F factory made solid PVC door frame of size 50 mm x 47 mm made out of 5mm thick plain colour PVC sheet reinforced M.S. square tube, supplying & fixing in opening as per specification & drawing on page no. 178 of SSR Part -II complete all as specified and directed.
10S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. square tube for top and bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip 20 mm wide stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in M.S. frame welded /sealed to the stiles and rails with suitable sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as per specification and drawing of page no 174 of SSR Part -II complete all as specified and directed.
11S&F 75 mm butt hinges heavy weight cold rolled mild steel and fixed complete all as specified and directed.
12S&F 150 mm aluminium anodised barrell tower bolts of extruded section and fixed complete all as specified and directed.
13S&F extruded aluminium alloy handles 125 mm long fabricated type anodised complete all as specified and directed .
14S&F in repairs door closer hydraulically ( aluminium extruded section body) regulated, designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed.
15S&F powder coated aluminium window frame 2/3 track outer frame 92 mm x 31.75 mm x1.50 mm and guide rail of section Nos size 92 x 31.75 x1.50mm and shutter section 40 x 18 x 1.550 mm sliding type including 5.0mm thick sheet glass of selected quality and fixed with rubber beading and aluminium hardware fittings including taking down existing one complete all as specified and directed.
16S&F in repair anodised aluminium grill, having mess size 100mmx100mm made out 6mm wide & 3mm thick aluminium section complete all as specified and directed.
17S&F aluminium door shutter with chowkats made out of hollow aluminium sections as mentioned below, each shutter having 2 Nos ‘D’ type aluminium handles of 200mm long 2 Nos aluminium tower bolts of 150 mm long and 1 No brass mortice lock of 6 lever with key in duplicate. Shutter shall be partly glazed with 5 mm thick sheet glass ordianry quality and partly panelled with 12mm thick particle board, pre-laminated interior grade, prelaminated one side with decorative choice lamination, on other side balancing light grey lamination fixed with glazing clips, rubber beadings and aluminium beadings complete all as specified and directed.Chowkat size : 101.60 x 44.45 x 2.40 mm (1.608 Kg/RM appx)Shutter Top rail : 114.30 x 2.15 mm thick (1.836 Kg/RM appx) Bottom rail: 150.00 x 2.20mm thick (2.376 Kg/RM appx) Middle rail : 83.50 x 1.70 mm thick (1.243 Kg/RM appx) Vertical rail : 85.00 x 1.80 mm thick (1.302 Kg/RM appx)
18Dismantling of wall and ceiling boards/ wall partition (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets / aluminium frame work complete all as specified and directed.
19S&F Anodised Aluminium Frame Work (snap grid) for false ceiling Work made from Anodised Aluminium main /cross tee of size not less than 38 mm x 24 mm x 1.5 mm thick and 28 mm x 24 mm x 1.5 mm thick respectively for false ceiling of grid size 600 mm x 600 mm including necessary hanging arrangement comprising of 6 mm dia MS rod, 'J' bolts with necessary bolts, nuts and washer all as per manufacturer's instruction. The snap grid (main & cross section) shall be supported at ends all along the wall with Anodised Aluminium angle of size 40mmx25mmx2mm, weighing 0.36 Kg / RM. The main and cross tees shall be jointed at junction / crossings with anodized aluminium angle bracket of size 15mmxl5mmx1.5mm, weighing 0.12 Kg per running metre, fixed with suitable size mild steel, bolts nuts and washers complete as per manufacturer's instruction and as specified and directed.
20S&F 12mm thick perforated particle board 60cm x60 cm in size for insulation and acoustic purposefixed with aluminium frame work in ceiling with screws or with staples on snap grid as per manufacturer's instruction complete all as specified and as directed.
21Material and labour for partition wall (Pannels of 1.44 sqm (approx) made out of aluminium anodized standard hollow sections 63.50 X 38.10 X 1.95mm thick snap fit beadings, standard rubber gasket, 5.5mm thick sheet glass and 6mm thick prelaminated partical board, interior grade with decorative choice lamination complete all as specified and directed. Note :-The scope of work include for taking down existing damaged aluminium door/window/grill/panels and the unit rate quoted shall be deemed to include for the same.
22Dismantling floor, hearth or wall tiling or stone slabs of any description and in any postion including cement mortar bedding (but not backing), removing and rubbish off the MD land complete all as specfied and directed
23M&L for 25 mm thick cement concrete type 'B-0' 1:2:4 using 12.5mm graded stone aggregate as in flooring all as specified and directed.
24M&L for Light shade vitrified ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick cement mortor (1:6) screed bed complete all as specified and directed.
25M&L light shed vitrified ceramic tiles 10 mm thick (square/ rectangular) polished as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick 1:4 cement morter complete all as specified and as directed
26Material & Labour for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed inneat cement slurry and pointed in white or coloured cement to match laid over and including cement screed 10 mm thick in 1:4 complete all as specified and as directed.
27M & L for coloured glazed ceramic tiles 350 x 250 x 7 mm /450 X 300 X 7/8 mm thick in dado set and jointed in neat cement slurry and pointed in coloured cement to match fixed over incl rendering in CM 1:4, 10mm thick all as specified and directed.
28M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone in slab, plateform, steps including grinding and polishing laid over 15 mm thick cement screed (1:4) and jointed with grey cement slurry and pointed with white cement complete all as specified and directed
29M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
30Demoliton brick work or stone masonry built in cement mortar including all quoins , arches , pillars etc and removing the debries to a distance 5km away from the Dockyard premises all as specified and directed.
31M&L for pre cast cement concrete type 1:3:6 type C-1 (20mm graded stone aggregate) block masonry with solid blocks exc 10 cm in width and setting in cement mortar 1:4 complete all as specified and directed.
32Demolition of cement concrete in ground floor and paving not exc 15cm thickness (Below or above ground level) including removal of debris from the Dockyard permises all as specified and directed.
33M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate 100mm thick as in sub base for floors, hard standings etc complete all as specified and directed.
34M&L for PCC 1:2:4 type B2, using 40mm graded aggregate 100mm thick as in floor and finishing the top surface even and smooth without using extra cement and spike rolling to surface or making impression of expanded metals whilst concrete green complete all as specified and directed.
35S&F in repair vitreous China Wash Basin, white, flat back of size 550 x 400 mm including suitable size of CI brackets, brass chromium plated waste fittings 32 mm dia with long screw shanks and fly nuts, flange and bedded in red lead cement including taking out old one complete all as specified and directed
36S&F in repair 15 mm dia pillar taps, cast copper alloy with capstan head/swan type, chromium plated, screwed down, high pressure with or without letter 'Hot' or Cold' with long screwed shanks and fly nuts screwed for iron pipes complete including taking out old one complete all as specified and directed
37S&F in repair15 mm dia bib taps, cast copper alloy fancy type, chromium plated with crutch or butterfly handle, screwed down screwed for iron pipe of for brass ferrule including taking down old one complete all as specified and directed.
38S & F in repair health faucet 15 mm bore brass chromium plated jet spray with CP pipe of 900 mm long and connector including taking down old one complete all as specified and as directed
39S&F in repair 10 Ltr capacity PVC valveless syphonic action type flushing cistern low level white, with inlet, ball valve, float and handle including PVC flush pipe and brackets complete fixed in wall and floor to trap of WC as required including taking down old one all as specified and directed.
40S&F in repairs vitreous China wash down water closet pan (pedestal pattern) white excluding fixing bolts, flushing cistern and flush pipe including taking out the existing unserviceable pedestal pan complete all as specified and directed.
41S&F in repair 15 mm dia PVC connections, 600 mm long with PTMT nuts of suitable size at two end complete all as specified and directed
42S&F in repair 15 mm dia PVC connections, 450 mm long with PTMT nuts of suitable size at two end complete all as specified and directed
43S&F in repair tubular towel rail 20 mm dia brass chromium plated 'D' type 60 cm long between flange brass CP including taking down old one complete all as specified and directed.
44Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
45Material & labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
46M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
47S&F for rolled mild steel chequered plate as covers confirming to Fe 290.Gde-E-165 welded to supporting of duct covers complete all as specified and directed.
48S&F vitreous China urinals, bowl type, flat back of size 465 x 355 x 265 mm (minimum) white with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinals against wall in CM (1:2), screwing urinal to plug etc including taking out old one complete all as specified and directed.
49S&F vitereous china urinal partition white of size 310 x 700mm etc., including taking out old one.complete all as specified and directed
50S&F in repair 32 mm dia High density polyethylene (HDPE ) pipe of pressure rating 6 Kg /Sq.cm as in waste pipe (Short Length) fixed to wash hand basin waste etc complete to floor including taking out old one all as specified and as directed
51Taking out PVC (SWR) soil waste and vent pipe of any size including all fittings etc complete all as specified and directed
52S&F 110 mm dia PVC (SWR) pipes single, socketed, in any length with rubber ring joints fixed to wall complete all as specified and directed
53S&F 110 mm bore PVC (SWR) bends (any radius) with oval access door complete all as specified and directed.
54S&F PVC (SWR) floor trap, 75 mm dia, plain with brass CP grating including jointing with solvent cement fixed including taking down old one complete all as specified and directed
55S&F in repairs 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
56S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including dismantling existing one complete all as specified and directed.
57S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specifiedd including dismantling existing one complete all specified and directed.
58Providing and removing from site after completion of work double steel scaffolding for the outer surfaces of the building to provide platform to the workmen complete all as specfied and directed. Note : The superficial area of the building cover is measured
59Material & labour for chipping (20mm to 50mm) of existing damaged, spalled & loose portion of concrete of the RCC members completely till the reinforcement is exposed and sound concrete is observed by using mechanical means and manual chisels and further the surface is cleaned with water jet, again clean the surface with blower to remove all loose fine particles present in the surfaces complete all as specified and directed.
60M&L for preparation of exposed of rusted steel reinforcement with metal wire brush , cleaning the rusted surfaces free from loose rust and application of rust remover cum passivator with brush to the rusted reinforcement , and removing rust with flex after 24 hours of application of rust remover with the help of wire brush, sand paper and thoroughly washed with water with the help of pressure jet and allowing it to dry complete all as specified and directed. Note: Area of cleaned reinforcement steel bar shall be measured for payment.
61M&L for preparation of surfaces of steel of reinforcement by cleaning and providing, mixing and applying zinc anti-rust agent as per manufacturers method of application to rebar corrosion protection system to reinforcement Fosroc or equivalent in M/S Sika India Pvt. Ltd. / M / S Choksey Chemicals Pvt. Ltd. / M/S Mapei Const Product India Pvt Ltd. / M/S THermax Ltd / M/S STP / M/S Dr Sunanada / M/S BASF or equivalent in as specified PS @3.75Kg/Sqm surface of steel reinforcement in two coats complete all as specified and directed.
62Chipping and removing of spalled concrete,craked,porous/Micro concrete above 25mmto 100mm: Chipping and removing of spalled concrete,craked,porous/Micro concrete andweekconcrete ,at allheigths and depths,upto a depth of 25mm behind thereinforcement rods or depth of cabonation whichever is deeper andcleaning of the reinforcement barsand exposed concrete to remove scale by chipping,wire brushing ,emery sheets etc to enable the mesurement of the reduced dia of the bars, application of zinc primer to the bars on all sides of the reinforcement and application opfepoxy bonding agent to exposedold concrete surfaces. Leaddistanceshall be 50m from ground level to unloading location. This also includes the chipping and removal of gunning work carried out recently to check the reinforcement in order to decide on the requirement and addition of reinforcement . Payment towards application of zinc primer and epoxy bonding agent shall be paid in respective items rate of the contract. Scope including menpower, machinery, tools and consumables etc , to complete the job as per direction of Engr-in - Charge Note : Superfical area of the concrete is measured.
63Bond coat: Applying zinc primer to the bars on all sides of the reinforcement and application of fepoxy bonding agent to of acrylic emulsion bonding agent (or) Epoxy bonding agent. This application shall be carried out for concrete structural bonding agent between old concrete surface to new concreteing Note : Superfical area of the concrete is measured
64Polymer Modified concrete: Providing and applying polymer modified cement concrte (1:1:2) in specfied ratio by using 15% polymer and 53 grade cement to RCC surfaces in case the damaged thickness of RCC exceeds 30mm, the thickness assumed max upto 100mm. etc incl certain formwork as per site condition complete as instructed and all as specified and directed.
65Anti Caronation coating at out side of the concrete surface: Acrylic based plasto-elastic, crack - bridging protective coating system. Over the entire concrete surface including materials, machinery, labour tools etc all complete all as specified and directed.Note : Superfical area of the concrete is measured.
66Grouting: A shrinkage free low viscos epoxy resin based injection of epoxy resin (wet and submerged cracks) apply of nozzles to be fixed shrinkage free moisture insentive epoxy resin free flow grout all as specified and directed. Note : Superfical area of the concrete is measured.
67M&L for MS TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia as reinforcement complete all as specified and directed.
68M&L for providing Shear connectors and Anchoring by drilling 16 mm dia holes up to depth of 100mm in concrete surfaces and fixing 10 mm dia TMT bars L shaped anchor rods as shear connectors by using Fosroc Lokfix chemical or any other equilent make as approved by GE (Mix of base and hardener of the polyester resin) in defective concrete area of the slab / column / beams / chajjas / lintel etc or any other structural member as per site requirement after cleaning the drilled hole by using water jet and after drying clean the surface with blower to remove all loose fine particles present in the hole. The Mix of base and hardener of the polyester resin shall be prepared by thorough mixing of base & hardener by the help of spatula. After preparing the mix the holes shall be filled to a minimum depth of 1/3rd of the hole with the prepared polyester resin and the reinforced bar shall be inserted to full depth of hole and extra length of the reinforcement bar shall be bent into the concrete to maintain proper cover to the reinforcement complete all as specified and directed.
69Drilling and fixing of copper nozzels in RC members : Drilling 10mm dia upto 300mm deep holes in structural members horizentally and vertically in stagged manner at the intervals as per specfications and drawings. Clean the holes by hair blower prior to fixing nozzels and insert 8mm dia. copper nozzels in holes for repair work and strengthening work of existing structure, materials machinery and menpower inclung etc, completed as per the direction of Engr-in-Charge. Note :- (a) Injection of chemical grout will be paid separate line item. (b) Superfical area of the concrete is measured.
70Ceiling of Cracks : Supply and apply a solvent -free, moisture tolerant, thixotropic, structural two-part adhisive. Mortar and concrete must be older than 28 days (depends on minimal requirement of strengths). Verify the substarte strength (concrete, masonary, natural stone). The substrate surface (all types) must be clean, dry and free from contaminants such as dirt,iol,grease, existing surface treatment and coatings etc. Steel substracts shall be removed. When using a thin layer adhesive, apply the mixed adhesive to the prepared surface with a spatula, trowel, notched towel, (or with hands protected with gloves). When applying as a repair mortar use form work. When using for bonding metal profiles onto vertical surfaces, support and press uniformly using props fro at least 12 hours, depending on the thickness applied (not more than 5mm) and the room temperature. Once hardened check the adhesion will be checked by tapping with a hammer.
71Supply and application of 4mm thick Epoxy self levelling floor system with Nitofloor SL 4000 or equivalent in as specified in PS over a coat of epoxy primer Nitoprime 25 or equivalent quivalent in as specified in PS including removal of existing damaged epoxy flooing and scarifying or grinding the surfaces to remove laitance with air blowers and cleaning the surface by water jetting and allowing to dry for 2 days complete all as specfied and directed by Engr-in- Charge. Note: (i) The rate by the contractor inclusive of construction joints as of flooring as appliacble and as directed by the manufacturer (ii)The work will be carried out by OEM/authorised applicator only.
72S&F venatian Roller blinds type 100mm wide including hanging arrangement made up of anodised aluminium channel with acrylic mechanism with bottom weight type vista leveler all as per manufacturers instructions and as directed by engg in charge including taking down the worn out venetian blinds complete all as specified and directed.
73Supply and fix 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed on the solid rounded or chamfered, put together with glue pinned at joints all as specified and directed.
74S&F 2nd class hard wood 40mm thick plain, framed panelled shuttters ( any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium, density, wood particle board with commercial face veneers all as specified and directed.
75S&F for factory made second class hard wood 35mm thick plain framed paelled shutters (two panelled ) with lock rails and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneerign o both faces The size of rail and stile as per IS:1003 (Part I) Kiln seasoend and chemically pressure treated all as specified and directed
76Forming jambs etc., to opening in brick masonry, including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work complete new work, built in cement mortar 1:6 all as specified and directed.
77M&L for PCC 1:3:6 type C1 using 20mm graded crushed aggregates as in anchoring hold fast bed plates etc complete all as specified and directed
78Taking down cement plaster on walls/Ceiling etc including racking out joints hacking for key scrubbing down with water and removing the debries away from the Dockyard premises all as specified and directed.
79M&L rendering 10 mm thick in CM (1:6) on fair faces of brick work or concrete surfaces and finishing the surface even and smooth with out using extra cement complete all as specified and directed.Note :- The work shall be executed at a height 8 to 15mtr and the contractor has to provide scaffolding etc wherever necessary. The unit rate quoted shall be deemed to included for the same.
80M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces and finishing the surface even and smooth with out using extra cement all as specified and directed.
81M&L for rendering 10mm thick cement plaster 1:3 on fair faces of brick work or concrete surfaces of ceilings finished even & smooth (without using extra cement) all as specified and directed.
82Supply only integral water proofing compound all as specified and directed.
83M&L for preparation of new plastered surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces over applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed.
84M&L for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of primer with 3mm thick wall care putty on wall complete all as specified and directed.
85M&L for preparation of new plastered surfaces of ceiling and applying two coats of distemper oil emulsion over a coat of primer 3mm thick wall care putty on ceiling complete all as specified and directed.
86Complete removal of existing treatment on walls and for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces with one coat of birla putty complete all as specified and directed.
87M&L for complete removal of existing treatment on ceiling and applying two coat of distemper oil emulsion over one coat of primer over 3mm thick wall care putty on ceiling complete all specified and directed.
88M&L for complete removal of existing treatment on wall and applying two coat of distemper oil emulsion over one coat of primer over 3mm thick wall care putty on wall complete all as specified and directed.
89M&L for preparation of new plastered surfaces of wall and applying two coat of distemper oil emulsion over a coat of primer with one coat birla putty complete all as specified and directed.
90M&L for Complete removal of existing treatment on walls and applying two coat of distemper oil emulsion over one coat of primer with one coat of birla putty complete all as specified and directed.
91M&L for preparation of new plastered surfaces of ceiling and two coats of distempering with distemper oil emulsion over a coat of primer with one coat of putty complete all as specified and directed.
92M&L for Complete removal of existing treatment on ceiling and applying two coat of distemper oil emulsion over one coat of primer with one coat of putty complete all as specified and directed.
93M&L for preparation of new plastered surfaces of walls and apply two coat of exterior weather proof emulsion over a coat of Alkaline resistance primer primer complete all as specified. ( in bldg height upto 20 mtrs.)
94Taking up or down 15 mm bore steel water tubing and connections including cleaning for refixing or removal complete all as specified and directed.
95Taking up or down 20 mm bore steel water tubing and connections including cleaning for refixing or removal complete all as specified and directed.
96Taking up or down 25 mm bore steel water tubing and connections including cleaning for refixing or removal complete all as specified and directed.
97S&F 15 mm dia (outer diameter of the pipe) Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed.
98S&F 20 mm dia (outer diameter of the pipe) Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed.
99S&F 25 mm dia (outer diameter of the pipe) Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed.
100Dismantling water tanks of capacity exc 1000 Ltr but n exc 2000 Ltr and removing to store complete all as specified and directed.
101S&F rotational moulded polythylene water storage tanks 2000 ltrs capacity (cylindrical or vertical with closed top) hoisted and fixed in position, complete all as specified and directed.
102Supply & fix brass ball valve 25 mm dia high pressure with polythene float and flynut including taking down old one complete all as specified and as directed
103Demolition of cement concrete in ground floor and paving not exc 15cm thickness (Below or above ground level) including removal of debris from the Dockyard permises all as specified and directed.
104M&L for PCC 1:3:6, type C2, (using 40mm graded stone aggregates) as in mass concrete finished even and smooth without using extra cement complete all as specified and directed.
105M&L for PCC 1:2:4 type B2, using 40mm graded aggregate 100mm thick as in floor and finishing the top surface even and smooth without using extra cement and spike rolling to surface or making impression of expanded metals whilst concrete green complete all as specified and directed.
106M&L for 75mm thick in cement concrete type C2 1:3:6 (Using 40mm graded stone aggregate) as in plinth protection finished even and smooth with out using extra cement complete all as specified and directed.
107[SCHEDULE 'A' PART-II [E/M WORKS]
108Taking down old unsv copper /aluminium point wiring (light, fan.socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keepin or for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces of walls,floors etc., all as specified and directed.
109Taking down old UNSV DB's and main switches along with MCB's and MCCB's all as specified and directed.
110M&L concealed point wiring with with 1.5 sq mm (nominal area), PVC insulated, stranded single core unsheathed FRLS copper conductor cable drawn through with PVC conduit medium grade with all fittings and accessories of PVC conduit/ casing caping (like Tee, bend etc) complete fixed to walls etc with and including 1.5 sqmm (nominal area) PVC insulated stranded single core unsheathed FRLS copper cable as earth continity wire connecting to common earth point including supply & fixing of galvanized pressed mild steel Modular terminal boxes of suitable size as require for fixing modular switch socket regulator etc. complete all as specified and directed including necessary chase cutting for conduits to walls, floors and sinking boxes and making good to walls, floors complete all as specified and directed.
111One light point point controlled by one 5 Amps switch one way
112One fan point controlled by one 5 Amps switch one way
113One 3/5 pin 5 Amp switch socket outlet on independent board
114One 3/5 pin 5 Amp socket outlet on same board.
115Supply & fix modular type switch 6 Amp oneway flush type all as specified and directed.
116Supply & fix modular type switch 6 Amp twoway flush type all as specified and directed.
117S&F Modular Switch socket outlet 2 in 1,3 pin 5 amp all as specified and directed.
118S&F modular coverplate with support plate for 3 modules and more complete all as specified and as directed.
119S&F modular coverplate with support plate for 8 modules and more complete all as specified and as directed.
120M&L concealed point wiring with with 4 sq mm (nominal area), PVC insulated, stranded single core unsheathed FRLS copper conductor cable drawn through with PVC conduit medium grade with all fittings and accessories of PVC conduit / casing caping (like Tee, bend etc) complete fixed to walls etc with and including 4 sqmm (nominal area) PVC insulated stranded single core unsheathed FRLS copper cable as earth continity wire connecting to common earth point including supply & fixing of galvanized pressed mild steel Modular terminal boxes of suitable size as require for 3/5 pin socket outlet 15 Amps complete all as specified and directed including necessary chase cutting for conduits to walls, floors and sinking boxes and making good to walls, floors complete all as specified and directed.
121S&F 6/15 Amps modular switch socket combination all as specified and directed.
122S&F Ceiling rose, 3 phase /PVC/ polycarbonate, isolated body complete all as specified and directed.
123S&F Fan step regulator, 120W - 2 module complete all as specified and as directed
124Supply & fix LED recessed full open 2 x 2 feet with highly efficient light smoothy optics to deliver superior illuminous and energy saving of 36 watts complete all as specified and directed.
125Supply & fix LED batten with CRCA body,pre coated with white and prewired suitable for LED tube 2 x 20 watt 4'long alongwith 2 number of tube all as specified and directed.
126S&F LED high bay light 200 watt at roof truss level of wksp buildings and other places along with welding/fixing of hook all as specified and directed.
127S&F SP MCB 6 to 32 Amps C Curve complete all as specified and directed.
128S&F TP MCB 25 to 63 Amps C Curve complete all as specified and directed.
129S&F TPN MCB 63 Amps C Curve complete all as specified and directed.
130S&F MCB, Double Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed.
131S&F Vertical MCB distribution board suitable for MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 12 way incl dismantling taking down unsv one all as specified and directed.
132S&F Vertical MCB distribution board suitable for MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 8 way incl dismantling taking down unsv one all as specified and directed.
133S&F MCCB, 16KA, 4 pole, with thermal magnetic trip unit, rated current 125amps complete with spider link incl dismentling taking down unsv one all as specified and directed (Suitable for MCCB incomer DB).
134S&F MCCB, 16KA, 4 pole, with thermal magnetic trip unit, rated current 160amps complete with spider link incl dismentling taking down unsv one all as specified and directed (Suitable for MCCB incomer DB).
135S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, SPN, 230 Volts, 8 way incl dismantling taking down unsv one all as specified and directed.
136S&F doubledoor TPN DB 4 way double door with 200 amp rated bus bar all as specified and directed.
137S&F MCB metal enclosure box of 4 module with complete connection complete all as specified and as directed. Please Enable Macros to View BoQ information
138S&F MCB metal enclosure box of 4 module with complete connection complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56863215
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 2.95 Crore
LAST DATE 02-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repairs To Building No. 556 Smu At Naval Dockyard, Visakhapatnam Under Ge (I) Dm Visakhapatnam
Basic Detail
Tender No 8558/C/E8
Bidding Type Tender
Location
City Visakhapatanam
State Andhra Pradesh
Key Dates
Publish Date 20 Aug 2026
Submission Date 02 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value 2.95 Crore
Tender Fee 2000
EMD 3.70 Lakhs
Exemption Available
Document List
74d295ef-9079-410d-aa17-5eac78344941.html
8558Tender.pdf
BOQ_877110.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 7 days
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

74d295ef-9079-410d-aa17-5eac78344941.html

pdf

8558Tender.pdf

xls

BOQ_877110.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders