Tender For Provn Of Toilet Block With Allied Works For Officers Mess At Bldg No Ch 10 At Comd Hosp (Wc) Chandimandir
Tender Overview
Project Description
Tender for Provn Of Toilet Block With Allied Works For Officers Mess At Bldg No Ch 10 At Comd Hosp (Wc) Chandimandir
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Surface dressing not exc. 15 cm deep as in soft / loose soil complete all as specified and directed. |
| 2 | Excavating in trenches, n exc 1.5m wide and n exc 1.5 m depth; for foundation, etc. manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 3 | M & L for Cement concrete (1:4:8) Type D-2 ( 40 mm graded crushed stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 4 | M&L for Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. |
| 5 | M&L for Brickwork with subclass `B' bricks, straight or curved on plan to any radius in half brick thick walls, built in CM (1:4) complete all as specified and directed. |
| 6 | Returning/filling in including spreading, levelling, watering and well ramming in layers n exc 25cm complete all as specified and directed. |
| 7 | Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 8 | M&L RCC (1:1.5:3 ) type A-1 using 20 mm graded crushed stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and directed. |
| 9 | M&L RCC (1:1.5:3 ) type A-1 using 20 mm graded crushed stone aggregate in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 10 | M & L for Reinforced Cement concrete (1:1.5:3 ) type A-1 (using 20 mm graded crushed stone aggregates) in beams, cantilevers, bressumers, lintels upto 1.5 m span complete all as specified and directed. |
| 11 | M & L for Reinforced Cement concrete (1:1.5:3 ) type A-1 (using 20 mm graded crushed stone aggregates) in slabs supported on walls complete all as specified and directed. |
| 12 | M & L for providing pre-cast cement concrete landing, cover slabs (for man holes etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar items with plain faces in cement concrete 1:2:4 type B-1, using 20 mm graded crushed stone aggregate and setting in cement mortar 1:6 complete all as specified and directed. |
| 13 | M & L for plain cement concrete type B1 (1:2:4) (using 20 mm graded crushed stone aggregate) as in surface channel or drain or benching in manhole complete all as specified and directed. |
| 14 | M & L for use and waste of formwork to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beams; and similar works; in rough finished flat surface of concrete complete all as specified and directed. |
| 15 | M & L for use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions in rough finished flat surface of concrete complete all as specified and directed. |
| 16 | M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished flat surface of concrete complete all as specified and directed. |
| 17 | M & L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works not exc. 200 mm thick horizontal or slopping in rough finished flat surface of concrete complete all as specified and directed. |
| 18 | M & L for use and waste of formwork to edges of concrete flats, treads, breaks in floor, window cills, concrete railing, opening in concrete wall, sides of RCC slab, RCC / PCC bends in walls or similar work thickness exc. 10 cm and not exc. 20 cm in rough finished flat surfaces of concrete complete all as specified and directed. |
| 19 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 20 | M & L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for slab, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 21 | M & L for mild steel TMT bars 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 22 | M&L for rendering 10mm thick in CM 1:6 on fair faces of brickwork or concrete surfaces finished even and fair without using extra cement. |
| 23 | M & L for 5 mm thick rendering in ceiling in cement mortar 1:3 on fair faces of brick work or concrete surfaces and finishing the surface even and fair complete all as specified and directed. |
| 24 | M&L rendering 15 mm thick in CM 1:4 mixed with WPC by weight of cement as per manufacturers instructon on other than fair faces of brickwork , finished even and fair without using extra cement. (WPC to be measured and paid for separately) |
| 25 | Supply only liquid integral water proofing compound. |
| 26 | M & L for hardcore broken stone or boulders of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15mm thick, watered and rammed to a true surface complete all as specified and directed. |
| 27 | M & L for 75 mm thick, cement concrete type C-2 , 1:3:6 (40 mm graded crushed stone aggregate) finishing the surfaces even and smooth without using extra cemen as in plinth protection complete all as specified and directed. |
| 28 | M & L for providing 100 mm thick cement concrete type D2 (1:4:8) (using 40 mm graded crushed stone aggregate) as in sub floor, sub base of floor complete all as specified and directed. |
| 29 | Supply & fix Glossy coloured concrete interlocking paver blocks with grey cement and pigment , design as approved,any size and shape, conforming to IS 15658-2006 of 80mm thickness, M-40 Grade and laid over and including 50 mm thick sand cushioning, for tiles complete all as specified and directed by Engineer - in - Charge |
| 30 | M & L for first quality Non skid ceramic coloured tiles 7 to 8mm thick (Square/reactangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jounted in neat cement slurry and pointed in white or coloured cement to match, over and including 15 mm thick screed bed in CM 1:6 complete. |
| 31 | M & L for first quality Glazed ceramic coloured tiles in vertical surface 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, over and including 10 mm thick backing coat in CM 1:4 complete. |
| 32 | M & L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over screed bed of 15 mm thick cement mortar 1:4 all as specified and directed by Engineer - in - Charge . |
| 33 | S&F Anodised aluminium frame powder coating ( Minimum thickness of powder coating 50 micron) for door, window and ventilator with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 34 | S&F 4.0 mm thick figured glass, pin head type glazing with clips in squares not exc. 0.50sqm in each pane complete all as specified and as directed. |
| 35 | S & F stainless steel wire cloth, 0.36mm nominal dia. of wire and average width of aperture 1.40mm fixed with tinned tacks, or stainless steel wire staples including all cuttings, wastage, etc complete all as specified and directed. |
| 36 | S & F solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as directed. |
| 37 | S & F Factory made particle board core solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 38 | S&F 100 mm long butt hinges, \\"medium weight\\" cold rolled mild steel complete all as specified and directed. |
| 39 | S&F 100 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 40 | S&F 150 mm extruded aluminum alloy handles, fabricated type, anodized complete all as specified and as directed. |
| 41 | M & L for applying two coats of acrylic distemper over one coat of primer over 1mm thick wall care putty to new plastered wall surfaces including preparation of surfaces complete all as specified |
| 42 | M & L for applying two coats of acrylic distemper over one coat of primer over 1mm thick wall care putty to new plastered ceiling surfaces inluding preparation of surfaces complete all as specified |
| 43 | M & L for preparation of new or previously untreated wall surfaces & applying two coats of acrylic base weather shield paint (1st quality) over one coat of exterior grade primer including preperation of surfaces complete all as specified & directed. |
| 44 | Supplying and laying 20 mm dia with all fittings, cutting, threading and fixing of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings and CPVC coated brass fittings as required on walls/ceiling or laying in floors complete all as specified. |
| 45 | Supplying and laying 25 mm dia with all fittings, cutting, threading and fixing of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 46 | S & F brass elbow suitable for 20mm CPVC Pipe complete all as specified and as directed. |
| 47 | S & F brass elbow suitable for 25mm CPVC Pipe complete all as specified and as directed. |
| 48 | S & F brass tee suitable for 20mm CPVC Pipe complete all as specified and as directed. |
| 49 | S & F brass tee suitable for 25mm CPVC Pipe complete all as specified and as directed. |
| 50 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunsheds, shelves, lintel etc. and cutting chases for concealed water tubing or concealed conduit wiring etc. complete all as directed. |
| 51 | Providing & fixing of White Vitreous China Wall-Hung Watercloset of Rimless Bowl Design with anti-bacterial glazing uptill trap end and with soft closing seat & cover, Product size should be 380x515x360 mm of Make: Jaquar CNS-WHT-963UFSM /Kohler Kohler 75708IN-SS-0/or equal approved in GROHE with warranty of 10 Years, completed to the satisfaction of Engineer-in-charge. |
| 52 | Providing, fixing and commissioning wall Concealed WC Flushing Cistern with Flushing Actuator Plate in chrome , Per flush water discharge rate 2L-4L Make : Jaquar Cat. No. JCS-WHT-2400G/Kohler K-26351IN-P-NA CISTERN with Face Plate - Jaquar JCP-CHR-152415/ kolher K-5413IN-M-CP/or equal approved in GROHE with warranty of 7 Years on concealed tank & 10 Years on Flush Plate complete as directed by Engineer-in-charge . |
| 53 | Providing & fixing Hand Spray/ with lever control (health faucet) with flow Rate of 3.78 LPM at 3 Bar pressure of Make: Jaquar ALD-CHR-573GD /Kohler (K-12927IN-CP + 1237064)/or equal approved in GROHE including flexible hose 1m long connection and holder for hand spray complete with warranty of 10 Years to the satisfaction of Engineer-in-charge. |
| 54 | Providing and fixing toilet roll holder with flap of make Jaquar ACN-CHR-1153S/ Kohler K-10705D-CP/or equal approved in GROHE with warranty of 10 Year as completed to the satisfaction to the Engineer-in-charge. |
| 55 | Providing and fixing chrome finish two way bib cock with wall flange flow rate of 6lmp @ 3bar of pressue, Nickel-10.0 micron Chromium-0.3 micron of approved make of Jaquar FLP-CHR-5041PM GA /kohler K-16094IN-4-CP/or equal approved in GROHE with warranty of 10 Years, completed to the satisfaction to the Engineer-in-charge. |
| 56 | Providing & Fixing of Chrome Finish Brass 15 mm dia. bore angle valve , having Plating: Nickel-10.0 micron Chromium-0.3 micron of Make: JAQUAR FLP-CHR-5053PM /Kohler K-23515IN-4-CP/ or equal approved in GROHE with wall flange with warranty of 10 Years completed to the satisfaction of Engineer-in-charge. |
| 57 | Providing and fixing white vitreous china Urinal without sensor but with fixing accessories set, back inlet,Anti germ glaze, concealed inlet & outlet to protect from faulse smell with Overall . Product Size 385x325x635 mm mm of approved make of Jaquar URS-WHT-13253N/Kohler K-16321IN-SS-0/or equal approved in GROHE with warranty of Urinal pot for 10 years and sensor 5 years complete as directed by Engineer-in-charge. |
| 58 | Providing and fixing Urinal Sensor Concealed Type Flush Valve for Urinal Complete set with 4 meter adopter wire Installation Box & Control Valve (9V transformer), water supply single line, pipeline Inlet & outlet lines(1/2\\" BSP/15mm),Flow Control with Brass Radiator Valve, Minimum residence time Around 7 Seconds, Flush Time 6 to 8 Seconds,Sensor range about 400mm (Default - High) Range Adjustable - 2 Steps (High & Low) (+/- 20%) High - 400 mm Low - 250 mm, Materails Base - PS Front Plate - SS -304 ,Eye PCB Holder - PC , Fixing Bracket - Nylon,Water Release Unit - Brass, Flow rate for Green fitting: 1 lpf @ 3Bar of water pressure of approved make of Jaquar SNR-STL-51077E4MADG1/Kohler K-16321IN-SS-0/or equal approved in GROHE with warranty of Urinal pot for 10 years and sensor 5 years complete as directed by Engineer-in-charge. |
| 59 | Providing and fixing Chrome finish Curved shaped urinal partition with frosted glass of thickness of 8mm . Size H: 900 W: 450 of make Jaquar JSE-CHR-110UC450X/kohler/or equal approved in GROHE with warranty of 10 Years , as directed by Engineer-in-charge. |
| 60 | Providing and fixing wash basin White glazed vitreous china under counter sunk Oval shaped wash basin of size 560x430x195mm of make of Jaquar FLS-WHT-5701/KohlerK-2211IN-0 /or equal approved in GROHE with warranty of 10 Years ,as per direction of Engineer-in-charge. |
| 61 | Providing and fixing Sensor Faucet for Wash Basin (9V transformer), Water Supply Cold or premix water (1 inlet),Water Temperature Maximum 65 ℃ ,Environment working Temperature 0 to 40℃ ,Self-close Over ride Time 12 sec ,IP Rating Protection against intrusion (control box) I P 66 andProtection against Ingress (sensor eye) IP 66, Factory setting Parameters Detection Range : 10 CM - 22CM Valve shut of Time : < 2s Detection Time/ Response Time : Sensor activation time : < 1s , Finish Plating: Nickel-10.0 micron Chromium-0.3 micron Flow rate for Green fitting: 3.8 lpm @ 3Bar of pressue of approved make of Jaquar SNR-CHR-51027EB/Kohler-18078IN-ND-CP /or equal approved in GROHE with minumum 5 years warranty & necessary accessories etc all complete as directed by the Engineer-in-charge. |
| 62 | Providing and fixing CP BRASS Chrome Polished finish Waste coupling 32mm Size Half Thread with 80mm Height of Make: Jaquar ALD-CHR- 709 /KohlerK-45433IN-CP/ or equal approved in GROHE with warranty of 10 Years completed to the satisfaction of Engineer-in-charge. |
| 63 | Providing and fixing Polished Chrome finish Bottle Trap 32mm Size with 300mm & 190mm Long Wall Connection Pipes & Wall Flange of Make: Jaquar ALD-CHR-769L300X190/Kohler K-75823IN-CP /or equal approved in GROHE with warranty of 10 Years completed to the satisfaction of Engineer-in-charge. |
| 64 | Providing and fixing CP Brass Towel ring of JAQUAR ACN-CHR-1121N/KOHLER K-5631IN-CP/or equal approved in GROHE with warranty of 10 Years , complete as per direction of Engineer- in-charge. |
| 65 | Providing and supplying stainless steel AISI 304 grade, touch-free infrared hand dryer with 1150W rated power & carbon brush motor 1150W with heater on, 500W with heater off, eco-friendly, Built in UV light to kill bacteria in air with Power and working LED indicator and with Air speed 60 m/s and sensing rage 15-20cm of Jaquar HDR-SSF-AK2803D / Kohler K-5486T-2-0P /or equal approved in GROHE with necessary accessories etc, with warranty of 2 Years ,complete as directed by the Engineer-in-charge. |
| 66 | Providing and supplying napkin paper dispensor stainless steel AISI 304, satin finish, Fully welded body, 0.8mm thick with burr-free edges, Seamless one-piece lid, 0,8mm thick, fixed to the body by means of 2 rivets that allows swinging down of lid for replenishment, Back-plate, 0.8 mm thick, with multiple slots for easy installation,The towel tray opening has bound edges to minimize tearing of paper towels.Slot at the front that indicates the content level. Dimensions 275x330x133 mm and paper capicity Max. 260x100 mm paper towel dispenser of approved make of Jaquar PTD-SAP-DT0106CSN/ Kohler/or equal approved in GROHE with necessary accessories etc all and with warranty of 2 Years ,complete as directed by the Engineer-in-charge. |
| 67 | Providing and fixing CP Brass Tumbler holder OF JAQUAR ACN-CHR-1141N/KOHLER K-5637IN-CP/or equal approved in GROHE with warranty of 10 Years complete as per direction of Engineer- in-charge. |
| 68 | Providing and fixing Soap Dispenser with Metallic Bottle OF JAQUAR ACN-CHR-1135 N/KOHLER/or equal approved in GROHE with warranty of 10 Years complete as per direction of Engineer-in-charge |
| 69 | S&F decorative fancy bevelled edge mirror of selected quality glass fixed with SS Screws cup washers complete all as specified & directed. |
| 70 | S & F 600 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed. |
| 71 | S & F for PVC (SWR) pipes, single socketed,110mm bore pipes, in any length with rubber joints,laid in trenches or in floors complete all as specified & directed. |
| 72 | S & F for PVC (SWR) bends 110 mm dia any radius with access door complete all as specified & directed. |
| 73 | M&L PVC (SWR) floor trap 100mm dia, plain with grating including jointing to waste pipe fixed in solvent cement complete all as specified & directed. |
| 74 | Cutting into existing manholes for connecting new drains 100mm dia, making good to pipe & rendering, cutting out existing benching for & forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, & reforming benching as required complete all as specified & directed. |
| 75 | Point wiring complete with 1.5 sq.mm FRLSH PVC insulated copper conductor single core in surface / recessed medium class PVC conduit with modular plate and cover with GI box and earthing the point with 1.5 Sq.mm FRLSH PVC insulated copper conductor single core cable etc as required for the following |
| 76 | One light/ fan point controlled by modular switch 6 Amp, single pole, one way, one module, 240V, complete all as specified and directed. |
| 77 | One 5 Amp socket outlet point on same board controlled by modular switch 6 Amp, single pole, one way, one module, 240V, complete all as specified and directed. |
| 78 | All as per Srl item No. 75 here-in-before but with 2.5 Sqmm single core multi stranded copper conductor of 1100 volts grade PVC FRLSH insulated and sheathed cable for one multipurpose switch socket outlet 6 pin 6/16 Amps on independent board including 2.5 Sqmm single core solid copper conductor 1100 volts grade PVC insulated and sheathed cable as earth continuity conductor to common earth and connecting to earth dolly. |
| 79 | S & F Modular switch 1 way 6A, 1 module, one way all as specified and directed by Engineer - in – Charge. |
| 80 | S & F Modular switch 1 way 16A, 1 module, one way all as specified and directed by Engineer - in – Charge. |
| 81 | S&F modular socket, 6A - 2/3 pin combined 2 module all as specified and directed by Engineer-in –Charge. |
| 82 | S&F modular socket 6A/16A - 2/3 pin combined 2 module all as specified and directed by Engineer-in –Charge. |
| 83 | M & L ceiling rose 65 x 50mm three terminals PVC/ polycorbonate, isolated body all as specified and directed by Engineer - in - Charge . |
| 84 | S&F LED tube light fittings mirror type with high out diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable complete all as specified and directed.Make Crompton Cat part no CCS-103-10-65-SL-DP-NWH or techno-equivalent make of Havells/ Jaquar/ Philips/ Wipro |
| 85 | S & F MCB distribution board of sheet metal single pole and neutral (SPN) 8 way, double door, with 100 Amp rated bus bar 240 volt all as specified and directed by Engineer-in- Charge. |
| 86 | S & F MCB Single Pole and Neutral (SPN) 32 Amps, 240 Volt, 'C' Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge. |
| 87 | S & F MCB Single Pole (SP) 06-32 Amps, 240 Volt 'B' Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge. |
| 88 | Supply and fix exhaust fan, made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 HZ , RPM 1200, copper winding of sweep 300m, frame and louvers including making hole suitable for 300 mm sweep exhaust fan complete all as specified and directed by Engineer– in– Charge. |
| 89 | Supply, lay, connection and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor,1100 volts grade, cross-sectional area 10 sq mm, 2 core, complete all as specified and directed |
| 90 | M&L sand cushioning for underground cable 8 cm below and 15 cm above the cable with clean dry river sand in trenches including spreading, levelling etc. complete all as specified and directed Note: Punned thickness will only be measured for the purpose of payment. |
| 91 | Supply and laying reinforced precast concrete cable cover class LV type-1 flat, size 250mmx150mmx40mm as protection to LT cable complete all as specified and as directed. |
| 92 | Earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of size 25 mm x 4 mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth strip shall be protected by 40mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 100mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed. |
| 93 | NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate.(b) Rate quoted shall deemed to include GI earth strip and GI protection pipe light grade.(c) Rate quoted shall deemed to include taking down old items. (d) Minimum 100 Kg salt and 100 Kg charcoal granual type to be used for each earth pit. The bed to be done in 3 x 15 cm depth of salt and 3 x 15 cm depth of charcoal in aternate.(e) PVC type DC insulators with screws, nuts, bolts etc to be used in suface/wall/floor for mounting of strip and distance between two insulator shall not be less than 1.0 mtr. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender