Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #56863169

Tender For Special Repair To Bldgs Of Certain Pump House , Power House And Other Misc Works Of Hq Wac ,At Subroto Park

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
48.50 Lakhs
Estimated cost
Bid Submission
25 Aug 2026
10 days left
EMD
97000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Bldgs Of Certain Pump House , Power House And Other Misc Works Of Hq Wac ,At Subroto Park

BOQ

Name of Work:- SPECIAL REPAIR TO BLDGS OF CERTAIN PUMP HOUSE , POWER HOUSE AND OTHER MISC WORKS OF HQ WAC ,AT SUBROTO PARK
Sl. No. Item Description
1Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-In-Charge.
2M&L for Vitrified Ceramic tiles light shade/dark shade /double charge/ ultracharged 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc over 15 mm thick screed in cement mortar 1:6 complete all as specified and directed by Engr-In-Charge.
3M&L for Non-Skid Coloured Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles over 15mm screed bed exceeding 0.11sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, complete all as specified and as directed by the Engineer-in-Charge .
4M&L for Linoleum, plain coloured, laid dry in floors including stretching, cutting and fitting, approved adhesive for sealed down, Cutting and waste and work in all position and in narrow Widths also Complete all as specified and directed by engineer-in-charge.
5M&L for vitrified ceramic tiles 9 to 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match etc over 15 mm thick screed in cement mortar 1:6 complete all as specified and directed by Engr-In-Charge.
6M&L for Vitrified coloured tiles (600x600)x9/10mm thick in skirting etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick plastering in CM 1:4 as in backing coat of tiles complete all as specifed and directed by engineer-in-charge.
7M&L for PCC 1:2:4 type B-0 (Using 12.5 mm graded stone aggregates) of 25 mm thick as in levelling course ,finished surfaces even and rough to receive floor finish complete all as specified and directed by engineer-in-charge.
8M&L for glazed ceramic coloured tiles of size 350 x 250 x 7mm/450 x 350 x 7mm thick over and including 10 mm thick rendering in cement mortar 1:4 as in backing coat for tiles on vertical surfaces,set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specifed and directed.
9Dismantling of Stone slabs and tiles/paver block laid, bedded and pointed in any mortar complete all as specified and directed by engineer-in-charge.
10M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 20 mm screed bed in cement mortar 1:6 complete all as specified and directed.
11Taking down cement of cement lime plaster of any description on brick or stone walls etc including ranking out joints hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge.
12M & L for 10-12mm thick polymer modified readymix cement based plaster complying to IS-1661-1972, IS-2250-1965, IS-2402-1963) or equivalent as approved by GE/Engr-in-charge applied as per manufacturer's instructions, on fair faces of brick masonry or concrete surfaces finished even and smooth,n brick or stone walls including raking out joints, hacking for key and scrubbing down with water, complete all as specified and as directed.
13M&L for rendering 5mm thick cement mortar (1:3) as in ceiling, soffit of staircase, chhajjas facia etc including cement slurry etc complete all as specified and as directed by the Engineer-in-Charge.
14Dismantling loose concrete cover of RCC columns, beams, slabs chajjas and the like as directed, roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry, incl derusting of steel reinforcement, providing fabric mild steel wire mesh 50 mm x 50 mm x 2 mm dia as reinforcement to concrete. surfaces shall thoroughly scrubbed with brushes, washed with water and allow to dry . To this surfaces apply chemical polycrete admixture at the rate not less than 2% by weight of cement and providing minimum 30 mm thick (average thickness ) gunniting mix (using 1 part of ordinary Portland cement 53 Grade and 2 parts of Coarse/ghaggar sand mixed with adhesive / admixture at the rate as directed) with a pressure of 2 to 2.5 Kg per Sq cm by gunniting machine and surfaces finished even and fair, incl necessary padding, shuttering / form work . Including 5 mm thick cement plaster in CM (1: 4 ) complete all as specified and directed by Engineer - in -charge. Note:- (a) Arrangement for proper covering of all electricals panels ,VCB,Transformers, to protect them from water ,dust etc with tarpaulin / flexible covers to get water proof arrangment for uninterrupted supply of electric while execution of work Work will executed upto3rd floor and for ceiling work contractor to make arrangments above the equipments by scaffolding etc for smooth working .(b) The rate is inclusive for scaffolding or reqd necessary arrangement for multi-storey bldg external gunniting.
15S&F in repair factory made of approved (manufacturers/Brand) FRP (fibre glass reinforced plastics) chajja of thickness 3 mm including fixed with flat iron 50x3 mm thick and 12mm dia bolt using rawl plug in masonary /RCC wall with all necessary fittings required to make the system functional. The FRP chajjas shall be made of resin transfer technology in a compact laminate in a single piece with protective gel coat, U/V coating on top to protect from extreme temperature ,weather and sun light. The width of cahjjas shall not be less than 600 mm and length of chajja vary from 750mm to 1800mm or as per requirement at site complete all as specified and directed.
16M & L for complete removal of existing roof treatment (Mud puska, Cement Tiles, bricks or Old APP Roof treatment and vegitation from root) including bedding layer in cement mortar/Mud and disposed from MoD land complete all as specified and directed by Engineer-in-charge.
17M&L PCC 1:2:4 type B1 (using 20mm graded stone aggregate) mixed with 3.00% liquid water proofing compound of weight of cement laid 25 mm thickness as in padding over roof slabs for providing proper slope to the concrete padding, surface finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
18M & L for cleaning and preparation of the surface to receive using water proofing system shall be a sound base, any crack shall be treated with cementious repair mortar or epoxy crack filling mortar by proper grooving arrangement complete all as directed by engr - in charge.
19Providing and laying / fixing TPO membrane of nonflammable waterproofing of roof which shall be a 1.5mm thick loose laid TPO membrane layers overlapped to achieve a minimum weld of 110mm, Hot air welding can be either handapplied or by means of automatic machines and the rolls either end are overlapped with layers of non-woven geotextilefiber, the separation layer provided to prevent the mechanical abrasion and cushioning between the membrane and the concrete substructure, the termination of membrane by aluminium strip anchoring. complete all as specified and directed by engineer-in-charge.Note: Work shall be executed by authorised applicator with prior experience of more than 5 years in applying similar system.
20S&F in repair 110 mm PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and directed by Engr-in-Charge
21S&F in repair 110 mm PVC (SWR) bends any radius complete all as specified and directed by Engr-in-Charge
22Demolition of concrete of any description and in any position not otherwise specifically provided for.complete all as specified and directed by Engr-In-Charge.
23M & L for 75mm thick PCC 1:3:6 type C-2 (40mm graded stone aggregate) as in plinth protection complete all as specified and directed by Engr-in-Charge.
24M&L for 20mm thick prepolished Granite slab of any colour/quality as approved by GE on top of platform, WHB counter and similar work including cutting rounding on edges etc machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over and including 15mm thick screed bed in CM 1:4. including grinding, polishing and cutting grooves for anti skid porpose complete all as specified and directed by Engr-In-Charge.
25Taking down chowkats or frames with shutters (with out taking off shutters from the frames) exc 1.5 Sqm but n exc 4 Sqm each,incl removing complete and making good after fixing of new chowkat to match existing finish complete all as specified and directed by Engr-In-Charge.
26S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibbers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners not paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
27S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45x85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length including making good complete all as per direction of Engineer-in-Charge: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
28S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) moulded decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
29S&F for Butt hinges of stainless steel 100mm size Heavy type complete all as spd and directed by Engr-in-Charge.
30S&F for 150mm long stainless steel handles, fancy type, fabricated type. complete all as specified and directed.
31S&F for 200 mm stainless steel, barrel tower bolts of extruded section and fixed complete all as specified and directed.
32S&F for Brass Mortice lock, vertical type, size 100mm 4 levers vertical with fancy handle (as decided by EIC) complete all as specified and directed.
33S&F as in repair in Door closer hydraulically regulated Aluminium (Die cast) body design No-3 universal type, suitable for door shutter of 851 to 1000mm in width and of weight between 61 to 80 Kg and fixed. Complete all as specified and directed by Engr-In-Charge.
34S&F for door stopper of of brass body and tongue with hard drawn steel spring, (140mm size), complete all as specified and directed.
35S & F in repair aluminum window / ventilators with aluminum anodized frame of aluminum section 62.5 x 37 x 2.5 mm thick with shutters having styles & rails of aluminum section 44.45 x 44.45 x 2.5 mm thick including jointing cleats, glazing clips, rubber packing, aluminum snap beading, screws anodized aluminum fittings such as hinges, tower bolts, handles etc including 5.5 mm thick ordinary plain glass complete. Including providing and fixing aluminum chequered grill of anodized section of mesh 100x100mm of 08 mm dia of bar fixed to frame with 20x20 mm aluminum flat with mire mesh fixed with screw complete all as specified and as directed.
36S & F in repair Aluminium door (single/double) leaf with anodized aluminium frame of section 62.5 x 37 x 2.5 mm thick, shutter with bottom & middle rail of section 112.50 x 37 x 2.5 mm thick and styles & top rail of section 83 x 37 x 2.5 mm thick with centrally locking arrangement with lock 7 lever and self closing device with rebate including jointing cleats, fixing of builders hardware fittings, necessary numbers of floor spring and glazing with 5.5 mm thick ordinary plain glass or alumium composite panel as per site requirement including necessary fittings, fixtures & aluminium snap beads Complete all as specified and directed.
37M&L for coloured chequered cement concrete tiles 25cm x25cm or 30cmX30cm x 25 mm thick, set, jointed & pointed in neat cement slurry with grey cement abd pigment over 20 mm screed bed in CM (1:6) , and removing of debris away from MOD land, complete all as specified and as directed by the Engineer-in-Charge
38M&L for Machine coloured pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60 mm thickness M-35 Grade.complete, with grey cement and pigment complete all as specified and directed by Engr-In-Charge.
39M&L for 75 mm thick Cement concrete type D-2,(1:4:8) (40mm graded aggregate) as in sub floors, sub bases , floors and pavings/ paver blocks etc, complete all as specified and directed by Engineer-in-charge.
40M&L for Fine aggregate (Sand) for cushioning as in interlocking paver blocks laying complete all as specified and directed by Engr-In-Charge.
41S & F as in repair false ceiling at all heights with GRG (Glass Fiber Reinforced Gypsum) false ceiling tiles of Size 595x595 mm, semi perforated 12mm thick micro regular edged of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Non-combustible as per BS 476 (part 4) - 1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross - T of size 15x32 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanized iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and complete all as per directions of the Engineer-in-Charge.
42Dismantling plain corrugated steel sheeting any gauage thick ness including Nainital and similar pattern complete all as specifed and directed.
43S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
44Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in- charge.
45M & L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. Complete all as specified and directed.
46S&F in repair steel rolling shutter , without ball bearing as specified including top cover anchoring rod ,hasp staple,( thickness of latches 1.25 mm) and one shop coat of primer erected in position as indicated , completed push pull or manual type all as specifed and directed by engineer in charge .
47M&L for greasing , oiling and servicing of steel rolling shutter push or pull manual type complete all as specified and directed by Engr-in-charge.
48M&L for two coats synthetic enamel paint over a coat of red oxide primer on steel surfaces of any description not otherwise described over 10 cm width or girth including preparation of surfaces complete all as specified and directed.
49S&F mild steel for framed structure like trrussed, purlins, crane gantries,post rails and fastenings and heavy bracket framming (Beam,Tee, Angle, Channels, flate sections) including distance pieces, cleats etc conforming to Fe410-W (Gde-E-250) quality-A, complete all as specified and directed by engineer-in-charge.
50S&F mild steel screwas bolt (Machine made) with hexagonal or square heads one end screwed , each screwed end have one washer and one nut, dia of shunk 11-15mm and length of bolt exc 5 cm and n exc 10cm. Complete all as specified and directed by engineer-in-charge.
51S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-24 complete all as specified and directed by Engr-in-charge.
52Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed by Engr-in-charge.
53S & F Rolled Mild Steel Plates (plain or Chequered) channels, square cut or notched, forming holes, with riveted, bolted or welded attachment confirming to Fe 410 - W, complete all as specified and directed.
54S&F mild steel flat iron as wind tie for roof including necessary drilling for securing bolts etc complete all as specified and directed.
55M&L for PCC 1:4:8 type D2,(using 40mm graded stone aggregates) as in foundation,filling and mass concrete all as specified and directed.
56M&L for preparing new/Old surfaces (plastered or unplastered) of walls and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed by the Engineer-in-Charge.
57M&L for preparing new/old surface of wall and applying distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer by EIC, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work complete all as specified and directed.
58M&L for three coats of white wash on ceiling, soffit of staircase, chhajjas facia etc newly plastered surfaces including preparation of newly plastered surfaces or unplastered surfaces complete all as specified and as directed by the Engineer-in-Charge.
59M&L for preparation of old decorative surfaces including scraping down smoke dust mould, mass and efflorescent, salt and trading oils and greasy spot etc. on ceiling including cornices, plasters etc. (plastered or unplastered surfaces) and applying one coat of white (lime) wash on old washed surfaces all as specified complete.
60Demolition of Brickwork or stone/boulders masonry built in cement mortar complete all as specified and as directed by the Engr-in-charge
61M&L for Brick work in cement mortar 1:4 using sub class B bricks straight or curved on plan exceeding 6m mean radius complete all as specified and as directed by the Engineer in Charge.
62M&L for Brick work in cement mortar 1:4 using sub class 'B' bricks in one brick thick honey comb work complete all as specified and as directed by the Engineer in Charge.
63M&L for loose filling with aggregate of broken stone or boulders of gauge 40 to 80mm in soakage pits, soakage wells all as specified and as directed by the Engr-in-charge
64M&L Hardcore of gauge n. exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface in broken stones or boulders all as specified and as directed by Engr-in-Charge .
65M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate), 100mm thick as in sub base complete all as specified and as directed by Engr-in-Charge.
66M&L for PCC 1:2:4 type B2 (using 40 mm grade stone aggregate), 100 mm thick as in sub base in floor/pavings etc finished fair and even without using extra cement complete all as specified and as directed by Engr-in-Charge.
67Excavating over areas, exc 1.5m and n.exc 3m deep and getting out in soft/loose/hard rock soil complete all as specified and as directed.
68Excavating over areas, n.exc 1.5m deep and getting out in soft/loose soil complete all as specified and as directed.
69Excavating over areas, exc 1.5m and n.exc 3m deep and getting out in soft/loose soil complete all as specified and as directed.
70Excavating over areas, exc 3 m and n.exc 4.5m deep and getting out in soft/loose soil complete all as specified and as directed.
71Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and directed.
72Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed out side MOD land complete all as specified and as directed.
73S&F mild steel TMT bars 10mm dia and over , cut to length, bent to shape requred, including crancing bending and binding with mild steel (anneal) wire not less than 0.90mm dia. Complete all as specified and directed.
74S&F mild steel TMT bars 6 to 8mm dia , cut to length, bent to shape requred, including crancing bending and binding with mild steel (anneal) wire not less than 0.90mm dia. Complete all as specified and directed
75M & L for formwork to soffits of suspended slab such as roof slab, floor slab, landing and similar work n.exc 200mm thick (Horizontal or sloping) flat in fair finished surfaces of concrete, complete all as specified and directed.
76M & L for formwork to cornices and mouldings of any shape in cross section and any girth in fair finished surfaces of concrete complete all as specified and as directed by Engr-in-Charge.
77S&F in repairs 110mm bore dia PVC (SWR) vent cowl complete all as specified and as directed by Engr-in-Charge.
78M&L for neeru finish to plastering complete all as specified and directed by Engr-in-charge.
79Demolition and breaking up drain pipes 150mm bore set in cement mortar incl demolation of PCC haunching etc, complete all as specified and directed.
80M&L double wall corrugated drain pipe ' DWCPE' (SN8) 180 mm (OD)/ 152 (ID) mm diameter, (ISI marked)laid on 150mm thick laid in pcc bed trenches and tested including fittings of same grade complete all as specified and directed
81M&L for cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in bed with thickness of bed below the barrel of pipe as 100mm and width of bed as 450mm to drain pipes of 150mm internal dia including packing under, and completely surrounding pipes with concrete after they are laid and tested complete all as specified and as directed by Engr-in-Charge
82M & L for cutting into existing Manholes for connecting new drains , 150mm dia, making good to pipes and rendering , cutting out existing benching for and forming branch channel ( 1/2 round or 3/4 section ) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required complete all as specified and as directed by Engr-in-Charge
83Excavation in trenches n.exc 1.5m wide and n.exc1.5 m in depth for foundation, or shafts, wells, cess pits manholes, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in any type of soil / rock (soft / hard / dense soil /rock) complete all as specified and directed by Engr-in-charge.
84S&F SFRC manhole cover slabs medium duty of any shape and size required and 65mm thick complete all as specified and directed by the Engr-in-charge.
85Demolition of RCC of any description in any position not otherwise specially provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
86M&L for providing reinforcement cement concrete 1:2:4 (using 20mm graded stone agg) as in slabs/ beams/column in floors balconies,canopies, desc slabs and the shelves and the like.
87M&L for RCC chajjas 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in approved design complete all as specified and directed by Engr-in-Charge
88Supply and laying of 15mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed.
89S&F as in repair Vitreous China Squatting pan, 'Orissa' pattern, size 580x440mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified and directed.
90S&F in repair CP bib taps long body , cast copper alloy, fancy type with crutch or butterfly handles, chromium plated, screwed down to iron pipes or for brass ferrule of 15 mm bore complete all as specified and directed by Engr-In-Charge.
91S&F in repair for CP shower rose of existing size complete all as specifed and directed.
92S&F in repair for CP shower arm of existing size complete all as specifed and directed.
93S&F for 75 mm bore PVC (SWR) pipe single socketed any length with rubber ring joints fixed on walls or laid in trenches , in floor or in under sunken system, including taking down complete all as specified and directed.NOTE :- Rate includes core cuttings of RCC slab/cutting holes in wall and all fittings as branch piece/ junction , single/ double/ triple , equal/ unequal.
94S&F in repair for 15mm bore brass chromium plated wall mixer for mixing hot and cold water screwed down for iron pipe and fixed to wall complete all as specifed and directed.
95S&F in repair CP stop/angle valves, cast copper alloy, fancy type, chromium plated with long shank & cup (concealed type) with crutch or butterfly handle, screwed both ends for iron pipe of 15 mm bore complete all as specified and directed by Engr-In-Charge.
96S&F in repair for 15mm bore dia fancy type pillar taps cast copper alloy with capston head chromium plated screwed down high pressure with or with out littred hot or cold with long screwed shanks and flynuts screwed for iron pipe complete all as specified and directed.
97S&F in repair 15 mm pillar taps swan neck cast copper alloy, with capstan heads, chromium plated screwed down high pressure, with or without lettered \\"Hot\\" or Cold with long screwed shanks and fly nuts screwed for iron pipes and fixed , fancy type complete all as specified and directed by Engr-In-Charge.
98S&F in repair Vitreous china coloured wash down water closet pan one pieces (Couple closet) with 'P' or 'S' trap, Soft close PVC seat cover and twin flushing cistern complete all as specified and as directed by Engineer-in-Charge.
99S&F as in repair fancy type mirror of 5 to 10 mm thick glossy glass decorative type, any size and shape beveled edges all-round, wall mounted mirror complete all as specified and directed by Engineer-in-Charge.
100S&F in repairs vitreous china wash hand basin of size 550 mm x 400 mm white, flat back incl angle iron brackets incl waste pipe of 32 mm dia of suitable length, pvc connection of 15 mm dia & 450 mm long with PTMT nuts with 32 mm dia brass chromium plated bottle trap and waste coupling complete all as specified and as directed by Engineer-in-Charge.
101S&F in repair for 10 ltrs capacity PVC valve less syphonic action type flushing cistern low level white inlet ball valve, float , flush pipe and handle including brackets and fixed complete all as specifed and directed.
102S&F as in repair 75mm pvc floor trap, with gratting including jointing to waste pipe fixed in cement concrete type B1(1:2:4), complete all as specified and directed.
103S&F as in repair 75mm pvc Nahani trap, with gratting including jointing to waste pipe fixed in cement concrete type B1(1:2:4), complete all as specified and directed.
104S&F in repair for CP towel rail of 20mm dia with hook 600mm long complete all as specifed and directed.
105S&F as in repair single towel RING complete all as specified & directed by Engr-in-charge.
106S&F as in repair soap dish complete all as specified & directed by Engr-in-charge.
107S&f as in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook ncluding making connections and fixed in position complete in all respect as specified
108S&F in repair 15mm dia CP jet with CP flexible pipe 90cm long incl necessary fittings complete all as specified and directed .
109S&F as in repair stainless steel toilet paper holder with Flap recessed type complete all as specified & directed by Engr-in-charge.
110Dismantling water tanks capacity exc 250 ltrs and n. exc. 500 ltrs & removing to store complete all as specified and as directed by the Engineer-in-Charge.
111S&F for rotational moulded polyethylene water storage tanks (white colour) of 500 ltrs capacity (cylindrical vertical with closed threaded top) hoisted and fixed in position including 20mm dia HD polythene float (ball) and epoxy coated aluminum rod (fly nut) screwed for iron pipe or brass ferrule complete all as specified and directed.
112Taking up or down 15mm bore steel tubing and connections, including cleaning for re- fixing or removal to store complete all as specified and directed by Engr-in-Charge.
113Taking up or down 20mm bore steel tubing and connections, including cleaning for re- fixing or removal to store complete all as spd and directed by Engr-in-Charge.
114S&F 15mm bore steel water tubing medium grade , galvanized ISI marked with all fittings fixed to wall including chesing & ceiling or laid in floors complete all as spd and directed by Engr-in-charge.
115S&F 20mm bore steel water tubing medium grade , galvanized ISI marked with all fittings fixed to wall & ceiling or laid in floors complete all as spd and directed by Engr-in-charge.
116S&F in reapir for Collapsible steel gates (single or double leaves as indicated) , top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, and making good after fixing of new gate to match existing finish Complete all as specified in SSR Part I, Section 10 clause 10.24 (1), (2), (3), (4) and (5) and directed by Engr-In-Charge.
117M&L for removal of old debris /malba with tractor trolley completely and make the existing area level and removing it outside MOD land complete all as specified and directed by engr-in-charge.
118S&F wide flange beams ISWB (depth-250mm, width of flange-200mm) of Fe 410-w (Gde-250)and palced it at ceiling level in ground floor , including cutting walls fixing it properly with ceiling and giving it fair finish complete all as specified and directed by engr -in- charge.
119Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
120M & L for Point wiring for one light point controlled by one SP switch using approved colour coding as per IS, with stranded copper conductor FRLSH 1.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed stranded cable 1100 volts grade,ISI-694 marked in and including heavy duty, PVC concealed conduit after chasing the wall etc and making good of disturbed surface including all accessories etc, heavy duty ISI marked, with mild steel sunken boxes duly powder coated with earth dolly duly, covered with modular plates suitable for modular switches, sockets etc including PVC insulated stranded copper conductor 1.5 Sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly. (Note- switch and sockets will be measured and paid seperately under the respective item of sch).
121All as per item No 120 here in before but for one fan/exhaust fan and wall mounted fan point controlled by one SP switch.
122All as per item No-120 above but for one 3 pin socket out let, 6 Amps on Independent board
123All as per item No-120 above but for one 3 pin socket out let, 6 Amps on same board
124All as per item No 120 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire of required size.
125S & F for Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed.
126S & F for Modular Socket, 6A - 3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed .
127S & F for Modular switch 1 way 16A, 1 modules suitable for 240 volt AC Complete all as specified and directed .
128S & F for Modular Socket, 16A - 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed.
129S & F for Electronic modular fan regulator rotary flush step type 120 watt, 240 volt complete complete all as specified and directed. .
130S & F for Ceiling roses, surface bakelite 65x50mm 2 or 3 terminals , PVC/ Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed.
131Taking down exhaust fan of any size dismantling blades and removing fan and blades to and deposit to MES store after making serviceable Complete all as specified and directed by Engineer-in-Charge.
132S & F heavy duty exhaust fan 450mm sweep, speed 1400 RPM, corrossion less mild steel body of motor, plastic/fibre blade for noise less operation, self operating louvers gives powerful performance round the clock, 230/240 volts single phase complete including making opening of suitable size of wall, grouting bolts and making good the distrubed surfaces and connection with 1.5 sqmm copper conductor flexible wire from ceiling rose to fan complete all as specified and directed.
133Fixing only exhaust fan with necessary fixing arrangment fastner etc retrived from item no 15 complete all as specified and directed.
134Taking down Ceiling fan of any size dismantling blades and removing fan and blades to and deposit to MES store after making serviceable Complete all as specified and directed by Engineer-in-Charge.
135Supply & fixing energy efficient BLDC ceiling fan 1200mm sweep , 28 Watt with remote , ISI mark with 5 star rating , white colour, single phase including all fixing arrangement hanging in roof like suitable size of fan road clips , bolt , nut , washers and 3 core flexible copper wire of size 1.5 sqmm not less than 0.5mtr long with all accessories complete all as specified and as directed.
136Supply and fixing as in repair wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge. Surya cat Part No SLE BT 20 G1 or make in Havells/Philips/Wipro\\"
137Fixing only LED lights fitting 1x 20W 220V, AC including electric conection with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
138Fixing only LED building / Street light fitting 1x 35W/ 40W, 220V, AC including electric conection with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
139Taking down unserviceable submain wiring of alluminium/ copper two/ three runs of any size cable including batten/conduit complete etc and making good disturbed surfaces complete all as specified and complete all as specified and directed by Engr-in-Charge.
140M & L for submain wiring with two run of single core 10.0 sqmm PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 10.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable -3 Runs of 10.0 Sqmm single core and one run of, PVC conduit shall be measured as one unit for payment purpose, complete all as specified and directed by engineer-in-charge.
141M & L for submain wiring with two run of 6.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable - 3 Runs of 6.0 Sqmm single core and one run of PVC conduit shall be measured as one unit for payment purpose, complete all as specified and directed by engineer-in-charge.
142M & L for submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable -3 Runs of 4.0 Sqmm single core and one run of PVC conduit shall be measured as one unit for payment purpose, complete all as specified and directed by engineer-in-charge.
143Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 12 way 230 volts double door type horizontal type complete all as specified and as directed by Engineer-in-Charge.Note :- MCB shall be measured and paid seperately.
144Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link ,earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type complete all as specified and as directed by Engineer-in-Charge.Note :- MCB shall be measured and paid seperately.
145Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 4 way 230 volts double door type horizontal type complete all as specified and as directed by Engineer-in-Charge.Note :- MCB shall be measured and paid seperately.
146Taking down unserviceable SP/ SPN MCBs of any capacities from the MCB DBs after disconnecting the electric supply complete all as specified.
147S&F for MCB SPN 32 Amps 10 KA, 240 volt 50 Hz 'C' Series all as specified and directed by engineer-in-charge.
148S&F for MCB SPN 40 Amps 10 KA, 240 volt 50 Hz 'C' Series all as specified and directed by engineer-in-charge.
149S&F for MCB SP 6 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56863169
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.50 Lakhs
LAST DATE 25-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Bldgs Of Certain Pump House , Power House And Other Misc Works Of Hq Wac ,At Subroto Park
Basic Detail
Tender No GE/SP/TOKEN-17/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 05 Aug 2026
Submission Date 25 Aug 2026
Open Date 28 Aug 2026
Finance
Tender Value 48.50 Lakhs
Tender Fee 500
EMD 97000
Exemption Available
Document List
BOQ_877151.xls
cea26e23-2d92-4414-b1d8-b88dff289f51.html
Tender17.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Aug 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_877151.xls

html

cea26e23-2d92-4414-b1d8-b88dff289f51.html

pdf

Tender17.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail