Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #56863156

Tender For special Repair Of Asbestos Sheet By Galvnished Iron Sheet, False Ceiling And Other Allied Works At Mh Roorkee Under Ge Roorkee

Issued by Statutory Bodies & Commissions/Committees · Haridwar, Uttarakhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
26 Aug 2026
19 days left
EMD
96250
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Haridwar → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair Of Asbestos Sheet By Galvnished Iron Sheet, False Ceiling And Other Allied Works At Mh Roorkee Under Ge Roorkee

BOQ

Name of Work:- SPL REPAIR OF ASBESTOS SHEET BY GALVNISHED IRON SHEET, FALSE CEILING AND OTHER ALLIED WORKS AT MH ROORKEE UNDER GE ROORKEE
Sl. No. Item Description
1Dismantling of Asbestos cement (corrugated, semicorrugated, etc) sheets in roof coverings complete all as specified and directed.
2Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
3Dismantling timber scantlings 40 sq cm and over in section, in any position, framed work complete all as specified and directed.
4Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
5M&L for MS (Structral) Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and, fixed with angle cleats or other connecting plates, including necessary welding or fixing with bolts of Fe 410-W(Gde-E-250) quality-A complete all as specified and directed.
6S&F Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick AZ-150 of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
7S&F Prepainted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick AZ-150 of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
8Dismantling of wall/ceiling boards Asbestos plywood of any thickness including cover fillets complete all as specified and directed.
9M&L for 600x600x4mm thick designer ceiling board as in false ceiling, colour & pattern as approved including GI frame work using main tee of size 24x38x0.5 mm and cross tee 24x28x0.5 mm made out of PGI sheet 0.30 mm thick doubled at web and single at flange. Flange covered with powder coated sheet 0.25 mm thick and angle 24 x24x0.4 mm covered with powder coated sheet 0.25 mm , thick for ceiling, suspended with GI wire 2 mm dia and upto 02 mtr long complete including plugging in brick wall/concrete surface with steel rawl plugs @ 600 mm c/c complete all as specified and directed.
10M&L for Plain cement concrete (1:2:4) ty B-0 as in lintels upto 1.5m clear span, cills, steps; copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
11M&L preparation new steel surface over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
12M&L for preparation of old painted steel and iron surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
13Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed.
14M&L for brick work in CM 1:6 using Sub class ‘B’ Bricks straight or curved on plan exc 6 m mean radius complete all as specified and directed.
15M&L for rendering 15 mm Thick in CM (1:6) on Brick surfaces, rendering is to be finished even and smooth (without using extra lime or cement) complete all as specified and directed.
16M&L for 2 coat of cement base paint over a coat of primer including prepration of newly plastered surface of wall complete all as specified and directed.
17M&L for preparation of old Plaster surfaces of walls, and applying one coat of cement base paint complete all as specified and directed.
18Taking down carefully U/S copper/aluminium point wiring (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified & directed.
19Taking down carefully sub-main wiring/service wire of any size including wooden batten etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified and directed.
20Taking down carefully existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified and directed.
21M&L for point wiring with 1.5 sq mm PVC insulated, unsheathed, stranded copper conductor (FRLS-H) cable single core 1100 Volt grade in and including rigid PVC conduit medium grade 20mm dia or more ISI Marked concealed conduit and conduit accessories and cutting chases of suitable girth where required on brick/concrete surface & making good disturbed surface, provision of GI/Pressed steel terminal switch box with plastic laminated sheet 3 mm thick fixed with brass screw and washers along with 1.5 sq mm PVC insulated unsheathed stranded copper conductor cable (FRLS-H) as earth wire connected with main common earth dolly complete all as specified and directed for the following :-(a) One light/fan/bell/exhaust fan point controlled by one, one-way non modular switch 5/6 Amp complete all as specified and directed.
22All as per item No 21.00 here-in-before but One 3pin/5pin 5/6 Amps socket out let on same board controlled by one, one-way non modular switch complete all as specified and directed.
23All as per item No 21.00 here-in-before but One 3pin/5pin 5/6 Amps socket out let on independent board controlled by one, one-way non modular switch complete all specified and directed.
24All as per item No 21.00 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor 1100 V grade PVC insulated (FRLS-H) but unsheathed single core for 16 Amps power point on independent board and 2.5 sqmm (FRLS-H) cable as earthwire complete all specified and directed.
25S&F switch piano flush type white finish 5/6 Amps, single pole one way, 230 volts, 50 hz complete all as specified and directed.
26S&F socket out let 2 pin 5/6 Amps & 3 pin 5/6 Amps flush type, 230 volts, 50 hz complete all as specified and directed.
27S&F switch piano flush type white finish 15/16 Amps single pole one way, 230 volts, 50 hz complete all as specified and directed.
28S&F socket out let 5 pin 15/16 Amps & 3 pin 5/6 Amps flush type, 230 volts, 50 hz complete all as specified and directed.
29S&F fan regulator, stepped type, electronic (socket type),100 watt compatible with BLDC FAN complete all as specified and directed.
30S&F lamp holder (Angular/Straight), insulated body, with back plate for batten fitting complete all as specified and directed.
31S&F LED Bulb 9 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable for \\"B-22 type to fix on batten holder complete all as specified and directed.
32M&L ceiling rose 3 terminal / PVC/ polycarbonate, isolated body complete all as specified and directed.
33S&F sheet metal enclosures with metal socket and plug top Single pole and neutral enclosure with a two pin and earth plug and socket complete ISI marked, 230/240 volts, 50 hz with one single pole MCB SP 25 Amps complete all as specified and directed.
34S&F of MCCB/MCB distribution board, Vertical TPN, 4 way, 415 V, 3 phase, AC with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with 200 Amps rated busbar minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed.Note: MCCB / MCBs shall be measured and paid separately.
35S&F of MCB distribution board, TPN, 4 way, 415 V, 3 phase, AC in sheet steel powder painted enclosure double door type with 200 Amps rated busbar minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. Note: MCBs shall be measured and paid separately.
36All as per item No 33 here-in-before but SPN, 8 way, 230 V, 1 phase, AC with 100 Amps rated busbar.
37All as per item No 33 here-in-before but SPN, 4 way, 230 V, 1 phase, AC 100 Amps rated busbar.
38S&F MCCB 100A, 25 KA, 4 Pole, 415 V, 50 Hz, Ics=100% Icu with fixed thermal magnetic release fixed in Vertical TPN complete all as specified and directed.
39S&F of MCB 100 Amp, 16 KA, TPN, 'C' curve, 415 V, 50 Hz, Ics=100% Icu complete all as specified and directed.
40S&F of MCB 40A, 16 KA, SPN, 'C curve, 240 V, 50 Hz complete all as specified and directed.
41S&F of MCB 06 to 32A, 10 KA, single Pole, 'C curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed.
42S&F in replacement of old unserviceable LED T5 tube light fitting 20 watts with polycarbonate housing and polycarbonate diffuser with integrated electronic driver with all accessories including connecting up with PVC insulated and PVC sheathed twisted three core flexible copper wire of 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and directed.
43S&F in replacement of recessed mounted LED panel light 2'x2' size, 36 watts, full white/warm white as per site requirement with electronic driver in CRCA sheet steel body with polycarbonate diffuser suitable for POP/Amstrong/grid false ceiling complete with all fixing accessories including making electrical connection with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified and directed.
44S&F in replacement of LED street/security light fitting 25 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 40 mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps (02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core PVC insulated and PVC sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed.
45S&F sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable (FRLS-H) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLS-H) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion complete all as specified and directed.
46Ditto all as per above but 4sqmm size
47Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron, UL listed, CPRI Tested at 25 KA fault current for one second and is provided with universal clamp made of SS earth enhancing compound shall be of 50kg/pit (resistivity is less than 0.12 Ohm meter) tested as per IEC 62561-7. The above arrangements shall be provided with heavy duty earth poly plastic pit cover of 6000 kg load bearing capacity (Size:270 x 240 x 200mm) and FRLS insulated copper conductor of size 6 sqmm, single core cable drawn through and including light grade GI pipe of size 15 mm upto 7 mtr incl cutting and chases on wall and floor and aking good using PCC complete all as specified and directed.Note : - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
48Dismantling & taking out old unserviceable LT UG cable & Supplying & laying in replacement of LT UG cable ( Conforming to IS 1554) ISI marked 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor in trenches/ducts/through HDPE pipe under roads of size 25 sqmm 4 core complete all as specifed and directed. Note;- The earth work shall be measured and paid sepretely under appropriate item of Sch A.
49Ditto all as above but of size 50 sqmm
50Excavation in trenches in soft/disintegrated soil not exc 1.5 m wide and not exceeding 1.5m in depth for laying UG cable/ foundation etc complete all as specified and directed.
51Returning filling in soft/disintegrated soil including spreading levelling watering and well ramming in layers n.exc 25cm each layer complete all as specified and directed.
52Removal of excavated surplus soft/disintegrated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
53M&L for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/ floors/ duct or fixed on walls/pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed.
54S&F GI tubing light grade ISI marked of 50 mm bore dia complete all as specified and directed.
55Supply, fabrication and fixing feeder pillar box of size 600x 450x550 mm made out of MS sheet of 3.15 mm thick bent to shape & size factory made with welding, bending works suitable for and including 200 Amps rated aluminium bus bars (length of bus bar not less than 40 cm) 4nos, making holes of required size and mounted on porcelain/epoxy based post insulators of appropriate size with suitable size of nuts, bolts and washers complete with mounting leg of size 40x40x5 mm and length of angle iron not less than 1 mtr, 0.5 mtr to be embeded in PCC below GL and 0.5 mtr above ground including painting of complete structure with two coats of super enamelled synthetic paint over a coat of red oxide and incoming/out going cable connections with required size of cable lugs with proper crimping complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56863156
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 26-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair Of Asbestos Sheet By Galvnished Iron Sheet, False Ceiling And Other Allied Works At Mh Roorkee Under Ge Roorkee
Basic Detail
Tender No 8392/604/E8
Bidding Type Tender
Location
City Haridwar
State Uttarakhand
Key Dates
Publish Date 05 Aug 2026
Submission Date 26 Aug 2026
Open Date 28 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 96250
Exemption Available
Document List
5a500775-5105-46d5-94c9-70b08d804bbf.html
604makelists.pdf
604TenderDocus.pdf
BOQ_877164.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Aug 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

5a500775-5105-46d5-94c9-70b08d804bbf.html

pdf

604makelists.pdf

pdf

604TenderDocus.pdf

xls

BOQ_877164.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender