Tender For Withdrawing And Lowering Of Submersible Pump Motor Set From The Old/Damaged Rbtws, Also Lowering In The Newly Sunk Rbtws(9 Nos) And Rectification Of Cable Fault At Ramnagar Head Works Site Under Rcfa Part-Iii(Zone-Ii) Water Supply Scheme.
Tender Overview
Project Description
Tender for Withdrawing And Lowering Of Submersible Pump Motor Set From The Old/Damaged Rbtws, Also Lowering In The Newly Sunk Rbtws(9 Nos) And Rectification Of Cable Fault At Ramnagar Head Works Site Under Rcfa Part-Iii(Zone-Ii) Water Supply Scheme.
BOQ
| Sl. No. | Item Description |
| 1 | Supply and delivery of following materials at site:- |
| 2 | Vertical submersible pumping machinery directly coupled with wet winding type suitable size submersible motor with following specification: Capacity 22 m3/Hr. at a head of 29 mtrs.,Motor submersible type-3.75KW/5 HP, 3 phase, 50 Hz ± 3%,415 Volt ± 6%, 2900 RPM as per Technical Specification. (DOL), Pump Outlet-3 Inch/80 mm(Dia).(Test certificate and guarantee certificate is to be submitted at the time of delivery) |
| 3 | 3 Core X 4 Sqmm 1.1 KV Grade flat submersible copper conductor cable as per IS:694.(20 Mtrs for each RBTW X 9 Nos RBTW + Other 4 Nos lowering X 15 Mtr per RBTW = 60 Mtr)(Make:-Gloster/Mescab/Other approved Make) |
| 4 | G.I. Wire for cable binding(Suitable SWG).(9 Nos RBTW X 2 Kg per RBTW) |
| 5 | 80 mm dia.1.5 mtr length ERW M.S. column pipe having thickness 4.85 mm,(as per IS 1239 Part-I Heavy Type) having 11 TPI thread at both end with one heavy type socket and painted by 2 coats of anticorrosive syntietic paint as per Technical specification.(Make:-Bansal/Jindal/Other approved make)(9 Nos RBTW X 8 Nos Column pipe for each) |
| 6 | 3 Core X 10 Sqmm Al.Ar. Cable, XLPE Insulated 1.1 KV Grade conforming to IS:7098(I).(Extra cable stored at site for future uses)(Test certificate and guarantee certificate is to be submitted at the time of delivery)(210 Mtr X 6 Nos RBTW + 430 Mtr X 3 Nos RBTW) |
| 7 | Making straight through joint of 3 Core X 10 mm² Al Ar Cable with flat submersible cable/3 Core X 10 Sqmm Al. Ar. cable by supplying Ferrule, rubber and other necessary materials to make the joint leak proof.(6 Nos RBTW cable extension joint + 9 Nos outside the RBTWs + Other 10 Nos for old cable rectification) |
| 8 | Making straight through joint between 1.5 mm2 or 2.5 mm2(motor cable) and supplied 4 mm2 submersible copper cable for extension of motor cable up to required lengh by supplying necessary seal kit to make joints leak proof all complete as per direction.(9 Nos for New RBTW + 1 No for Old RBTW) |
| 9 | Withdrawing of submersible pumping machineries from old river bed Tube Well along with Column pipe after disconnection of all pipe line and power line connection with the help of Derrick and Chain Pulley arrangement by engaging skilled technician as per direction of EIC. 5/6 HP S/M P/M. |
| 10 | Installation of submersible pumping machinery along with 80 mm dia. M.S. column pipe part by part in the newly sunk tube wells with an arrangement of derrick, lifting tackles, tools and plants etc. on hire basis and binding the vertical submersible cable with the column pipes properly and fixing M.S. Top Cover on the tube wells with supplying necessary Clamps made of 65 mmX 12 mm thick flat as per reqd length, nuts, bolts, washers etc. all complete as per direction. 5 HP S/M P/M. |
| 11 | Lowering of Submersible pump Motor set along with 80 mm dia Column pipe part by part in the existing Tube Wells with an arrangement of Derrick and Chain Pulley arrangement, making Pipe line connection etc. all complete as per direction of EIC.(5 H.P. S/M P/M.)5 HP S/M P/M. |
| 12 | Earth work in excavation of Cable line trenches, in all sorts of soil including removing, spreading or stacking the spoils within a lead of 75 m. as directed &filling the same with excaveted soil including ramming dressing after all complete. The item includes necessary trimming the sides of trenches,levelling,dressing and ramming the bottom, bailing out water as required complete.(For 9 No of RBTWs) Depth of excavation not exceeding 1,500 mm.(1290 Mtr. Cable X 0.3 Mtr. Width X 0.5 Mtr depth) |
| 13 | Sand cutting and removing from the river bed Ajoy for withdrawing and laying of cable line up to the depth of 1.5m from the damodar level as per direction of EIC.(New Cable laying)(1200 Mtr cable X 0.5 mtr depth X 0.3 Mtr width) |
| 14 | Laying of 3 Core X 10 Sqmm Al. Ar. Cable along the length of G.I. collecting line including fixing with supplied G.I. wire at a suitable interval so as to prevent sagging of cable complete as per direction of EIC.(Kiosk Box to RBTWs) |
| 15 | Laying 3 Core X 10 Sqmm through existing soil trench/Masonry trench.(Panel to Kiosk Box) |
| 16 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm.including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)-(a) With earth obtained from excavation of foundation. |
| 17 | Filling the trenches with excavated sand by engaging manual labour as per direction. |
| 18 | Jungle cutting, cleaning compound premises or shrubs, plants, jungles etc. by cutting and removingas directed.(Specific permission of Engineer in Charge prior to execution will be necessary.(To cleaning the 11 Nos tubewell surrounding+ Cable laying Route) |
| 19 | Supply and fitting, fixing of new terminal in the existing kiosk box. |
| 20 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.(Finishing at Kiosk and Panel end) |
| 21 | Add. GST@18% |
| 22 | Add. Cess@1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender