Drinking Water Supply and Sanitation Government Departments Closing in 4 days TDR #56862026

Tender For Replacement Of Damaged Delivery Common Header Line Of Ramnagar Pump House Inside Kalyaneswari Wtp And Providing ,Fitting,Fixing Of Lighting Luminaries At 33Kv Substation Area Of Kalyaneswari Headworks Site Under Rcfa Part-I Water Supply Sc

Issued by Government Departments · Paschim Bardhaman, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Aug 2026
4 days left
EMD
18000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Paschim Bardhaman → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Damaged Delivery Common Header Line Of Ramnagar Pump House Inside Kalyaneswari Wtp And Providing ,Fitting,Fixing Of Lighting Luminaries At 33Kv Substation Area Of Kalyaneswari Headworks Site Under Rcfa Part-I Water Supply Scheme.

BOQ

Name of Work:- Replacement of damaged delivery common header line of Ramnagar pump house inside kalyaneswari WTP and providing ,fitting,fixing of lighting luminaries at 33KV substation area of kalyaneswari Headworks site under RCFA Part-I Water Supply Scheme.
Sl. No. Item Description
1Supply and delivery of following materials at site:-
2200 mm dia MS Black pipe as per P/E Conforming to IS:3589 Gr.330, 8 mm thick.
3200 mm dia Cone sphere design, double flanged manually gear operated Cast Iron Butterfly Valve having body disc and end cover in graded cast Iron to IS 210 Gr. FG 200.synthetic rubber face ring secured on disc by a SS retaining ring with stainless steel screws , the rubber ring seating on a corresponding SS seat in body, stub shaft of AISI 431 riding in teflon bearings , valves suitable for a working pressure of 10/16 kg/sq cm (seat test) and body tested to 15 kg/sqcm. Flanges drilled to IS:1538 Table 4 & 6.(Make:-Approved Make)
4200 mm dia MS Slip-on-flange as per IS:1538.
5Atfirst removing damaged delivery pipe line from the centrifugal pump set, then making a new delivery line by using above supplied materials from SL No-1.01 o 1.03, this cost included with all erection jobs like cutting, welding, fitting also technician cost as per direction of EIC.
6Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)-25 mm dia Medium quality.(For Priming of Centrifugal Pumps)
7Supply and fitting, fixing of 25 mm dia Bronze Ball valve(Screwed). (Make:-Zoloto/Approved make)
8Construction of different dia Sluicevalve/Airvalve/Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for perationofvalveallcompleteincludingcostoflabour&materialsasper Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified]-300 mm dia.
9Renewing lead joint to CI pipes and specials and spun yarn including reusing 60% of old and using 40% new lead of approved quality new span yarn and caulking the same properly including labour charges for dismantling the existing damaged portion complete as per direction of EIC. Approved quality lead, spun yarn, fuel and othermaterials will be supplied by the agency including necessary earthwork in exacavation & backfilling in same trenches.NB:-This item will be executed as per specific direction of EIC.
10300 mm dia.
11200 mm dia.
12Labour charges for repairing of UPVC pipe by using UPVC socket and solvent cement including earth work in excavation with dewatering and necessary tracing out the actual position of brusting/leakage, cutting the pipe to required length in the trenches and replacing the same with new pipe (as per required length) including fitting fixing after roughing the UPVC surface & supplying and applying solvent cement, back filling the trenches with excavated earth upto the same as per direction of EIC all complete (UPVC pipes and specials,solvent, cementto be supplied by the Agency).Unserviceable broken withdrawn surplus materials are to be deposited to the Deptt. store.
1375 mm dia.
14Dismantling existing ferule with fitting and refixing the same after cleaning and washing of pipe line upto stand post.
15Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.
16Brick work with 1st class bricks in cement mortar (1:4) (a) In foundation and plinth
17M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length,fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.II) II) For Structural Works in Roof Trusses etc. using joists, channels and angles of specified section weighing less than 22.5 kg/ m.
18a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
19On steel or other metal surface : With super gloss (hi-gloss) Two coats (with any shade except white)
20Supplying and fixing 240/415 V, 63 Amp, FP, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.(Make:-Havells/Other approved make)
21Supply of 3 Pole, 18 Amp, AC-3 Duty power contactor with 1 No auxiliary contact, coil voltage-220-240 V, AC.(Make:-L & K, Model No-MNX18, Model No-CS94100)
22Supply of Digital time switch with 110 - 240 VAC 1 C/O Base/DIN 25 ON/OFF Each.(Make:-L & K, Model No-Time Switch (Crono), Cat No-67DDT0)
23Supply of Analog time switch with 240 VAC Base/DIN Mounting.(Make:-L & K, Model No:-FM1/Quartz Daily, Cat No:-J648B1)
24Atfirst removing damaged time switches, power contactor etc from the outdoor & indoor yard lighting panel then fitting, fixing new one, also doing all necessary connections, work should be done by skilled electrician.
25Supplying and fixing, 6-32 Amps, FP, 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make:-Havells/Other approved make)
26Supplying and fixing, 6-32 Amps, DP, 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make:-Havells/Other approved make)
27Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.-2 X 56/0.3(4 Sqmm) + 1X36/0.3(2.5 Sqmm)
28Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
292.5 Sqmm.
304 Sqmm.
31Sludge Removal drain cleaning:-
32Earth work for removing semi liquid mad or slushy earth by iron pans, buckets etc.
33Dewatering from the excavated trenches for repairing any type of pipe line including Hire Charge of pump / carriage / Fuel & lubricant / Operator etc. for big dia pipes more, than 200 mm dia all complete as per direction of EIC. (This item will be executed after the permission of E.l.C.)
34Earth work in filling in compound, tank, low land, ditches ese, with good earth, in layers not exceeding 150 mm. including breaking clods and consolidating the same by ramming and dressing complete. (Payment will be made on profile measurement before and after the work)1) With carried curth arranged by the contractor within a radius exceeding 5 km. but not exceeding 10 Im including cost of carried earth.
35Yard lighting Luminaries Portion of U-Park
36Dismantling and lowering of the indoor lighting luminaries and after disconnection of electrical connection etc as per direction.
37Dismantling and lowering of the outdoor lighting luminaries from the top of the pole as well as outside of pump house and OHR by using of scaffolding arrangement after disconnection of electrical connection etc as per direction.
3875 Watt. LED Highly efficient IP-65 LED street-light with aluminium pressure die-cast housing, toughened glass in the front and peanut lens for batwing light distribution, higher spacing between poles and maintenance-free system.(Make:-Approved Make)
3935 Watt. LED Highly efficient IP-65 LED street-light with aluminium pressure die-cast housing, toughened glass in the front and peanut lens for batwing light distribution, higher spacing between poles and maintenance-free system.(Make:-Approved Make)
4012 Watt LED inverter bulb with 4 hours emergency light(White).(Make:-Approved make)
41200 Watt High efficiency IP:65 LED flood light with pressure die cast aluminium housing in rectangle shape and toughened glass in the front. Best suitable for area lighting with 22000 lumen out put.(Make-Approved Make)
4290 Watt. LED Highly efficient IP65 LED street-light with aluminium pressure die-cast housing, toughened glass in the front and peanut lens for batwing light distribution,higher spacing between poles and maintenance-free system.(Make-Approved Make)
434 ft. long 22 Watt LED Tubelight Slim LED batten with aluminium housing and polycarbonate diffuser is an ideal replacement solution for existing battens/fluorescent lamps with elegantly designed end caps with 2200 lumen output.(Make:-Approved Make)
44Blue coloured 0.5 Watt LED night Bulb.(Make:-Approved Make)
453 CoreX 1.5 Sqmm industrial flexible copper cable wire/dia-30/0.25 PVC insulated with PVC sheathed as per IS:694.(Make:Approved Make)
4620 Watt LED tube range integrates LED light source with frosted cover design into traditional linear fluorescent from delivering 50-60% energy saving.(Make:-Approved make)
4720 Watt LED Bulb with 2000 lumen output.(Make:-Approved make)
489 Watt LED Bulb with 825 lumen output.(Make:-Approved make)
49Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
50Fitting & fixing of the indoor lighting luminaries along with new & old accessories to the pole etc as per direction of EIC.
51Fixing only Single LED Batten light fitting complete with all accessories directly on wall by screws etc.
52Fitting & fixing of the outdoor lighting luminaries along with new & old accessories to the pole and sub-station building etc as per direction of EIC.
53Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure.
54Add GST @ 18%
55Add CESS @ 1% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56862026
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 21-08-2026
Authority
Authority Name Public Health And Engineering Department
Work Description Tender for Replacement Of Damaged Delivery Common Header Line Of Ramnagar Pump House Inside Kalyaneswari Wtp And Providing ,Fitting,Fixing Of Lighting Luminaries At 33Kv Substation Area Of Kalyaneswari Headworks Site Under Rcfa Part-I Water Supply Scheme.
Basic Detail
Tender No WBPHED/EE/AMD/ NIeT-21 of 2026-2027
Bidding Type Tender
Location
City Paschim Bardhaman
State West Bengal
Key Dates
Publish Date 05 Aug 2026
Submission Date 21 Aug 2026
Open Date 24 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 18000
Exemption Not Available
Document List
311ec6ef-eb84-42a5-892c-eeb0a6770862.html
BOQ_2545770.xls
Tendernotice_1 (16).pdf
Tendernotice_2 (2).pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

311ec6ef-eb84-42a5-892c-eeb0a6770862.html

xls

BOQ_2545770.xls

pdf

Tendernotice_1 (16).pdf

pdf

Tendernotice_2 (2).pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders