Tender For Repair Of Electrical Starter Panel Board Of Various Urban Water Supply Scheme Under Sub Division Hanumangarh Town
Tender Overview
Project Description
Tender for Repair Of Electrical Starter Panel Board Of Various Urban Water Supply Scheme Under Sub Division Hanumangarh Town
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-Aug-2026 | Order No. 2414-25 Date 12.08.2026 | Date | 20-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Repair of electrical starter panel board of various urban water supply scheme under sub division Hanumangarh Town |
| 2 | 2.19 Supply and Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. |
| 3 | 3 core 6.0 Sq.mm |
| 4 | 090600 SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L and S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs and spreaders, etc. as required.090620 With Microprocessor based release090623 630 Amp , 35/50 kA, adjustable O/L and adjustable S/C setting, Ics = 100 % Icu090623.2 Group - 1 |
| 5 | 090600 SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L and S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs and spreaders, etc. as required.090610 With Thermal Magnetic release090616 200 Amp , 25/35 kA, adjustable O/L and fixed S/C setting, Ics = 100 % Icu090616.2 Group - 1 |
| 6 | 090600 SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L and S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs and spreaders, etc. as required.090610 With Thermal Magnetic release090615 160 Amp , 25 kA, adjustable O/L and fixed S/C setting, Ics = 100 % Icu090615.2 Group - 1 |
| 7 | 090600 SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L and S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs and spreaders, etc. as required.090610 With Thermal Magnetic release090614 up to 125 Amp , 25 kA, adjustable O/L and fixed S/C setting, Ics = 100 % Icu090614.2 Group - 1 |
| 8 | 090600 SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L and S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs and spreaders, etc. as required.090610 With Thermal Magnetic release090613 up to 100 Amp , 25 kA, adjustable O/L and fixed S/C setting, Ics = 100 % Icu090613.2 Group - 1 |
| 9 | 080800 SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required.080802 Blue colour080802.2 Group - 1 |
| 10 | 080800 SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required.080801 Red/yellow/Green colour080801.2 Group - 1 |
| 11 | 081500 P and F of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, auuxilary contacts, Din rail mounting type including making connections, testing etc. as required.081510 3 pole Power contactors with following AC 3 Rating081515 40 to 50 Amp081515.2 Group - 1 |
| 12 | 081500 P and F of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, auuxilary contacts, Din rail mounting type including making connections, testing etc. as required.081510 3 pole Power contactors with following AC 3 Rating081513 32 Amp.081513.2 Group - 1 |
| 13 | 081500 P and F of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, auuxilary contacts, Din rail mounting type including making connections, testing etc. as required.081510 3 pole Power contactors with following AC 3 Rating081512 13 to 25 Amp081512.2 Group - 1 |
| 14 | 081700 P and F thermal over load relay with built in single phase protection and having at least 1NO and 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081704 31 to 40 Amp081704.2 Group - 1 |
| 15 | 081700 P and F thermal over load relay with built in single phase protection and having at least 1NO and 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081703 21 to 30 Amp081703.2 Group - 1 |
| 16 | 081700 P and F thermal over load relay with built in single phase protection and having at least 1NO and 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081702 15 to 20 Amp081702.2 Group - 1 |
| 17 | 081700 P and F thermal over load relay with built in single phase protection and having at least 1NO and 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081701 Up to 14 Amp081701.2 Group - 1 |
| 18 | Labour charges for removing electric fault in wiring / making connection through lugs (with the help of cramping tool) of motor pump set with starter at headworks of water supply scheme/Tubewell/ openwell including cost of insulation tape etc.. |
| 19 | Labour charges for replacement of defective ampere meter / volt meter with new one on existing panel board in pump house./Tubewell /openwell (new voltmeter/ampere meter will be provided by department |
| 20 | Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment) |
| 21 | 5 to 15 HP. |
| 22 | 16 to 30 HP. |
| 23 | 31 to 60 HP. |
| 24 | 61 to 100 HP. |
| 25 | 101 to 150 HP. |
| 26 | Labour charges for repairing of soft starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment) |
| 27 | 5 to 15 HP. |
| 28 | 16 to 30 HP. |
| 29 | 31 to 60 HP. |
| 30 | 61 to 100 HP. |
| 31 | 082000 P and F of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming etc. as required082003 One day and week reserve (digital type )082003.2 Group - 1 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender