Tender For Construction Of Control Room Building And Civil Works Related To 3.15Mva,33/11Kv Receiving Station At Salwah Under The Jurisdiction Sub-Transmission Division (Jpdcl) Kalakote Under Ut Capex
Tender Overview
Project Description
Tender for Construction Of Control Room Building And Civil Works Related To 3.15Mva,33/11Kv Receiving Station At Salwah Under The Jurisdiction Sub-Transmission Division (Jpdcl) Kalakote Under Ut Capex
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-Aug-2026 | DATE EXTENSION | Date | 22-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Comtrol Room Building |
| 2 | Earth work in excavation by manual means over areas (exceeding 30 cm and upto 1.50 mtr in depth, 1.50 mtr in width as well as 10 sqm on plan) incl. disposal of excavated earth upto 1 mtr from cutting edge, disposed earth to be levelled and neatly dressed. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth slides of foundations etc in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead up to 50 m and lift up to 1.5 m Qntty. Vide item 1 above = 330.00 cum |
| 4 | Providing and Laying in position cement concrete of specified grade excluding the cost of centring and shuttering-All work up to plinth level 1:4:8(1 cement4 coarse sand:8 graded stone aggregate 40 mm nominal size) crushed. Foundations; |
| 5 | Supplying and filling in plinth with fine sand under floors including watering, ramming, consolidating and dressing complete. |
| 6 | Providing and fixing upto floor five level precast cement concrete cover slabs incl. Hoisting and setting in position with cement mortar 1:3(1 cement:3 coarse sand)cost of required centring, shuttering complete. 1:1.5:3(1 cement:1.5 coarse sand:3 graded stone aggregate 12.5 mm nominal size)Crushed Duct covers: 9.00x1.10x0.05 = 0.50 Say 1 cum |
| 7 | Providing and Laying damp proof course 40 mm thick with cement conc. 1:1.5:3(1 cement:1.5 coarse sand:3 graded stone aggregate 12.5 mm nominal size) crushed |
| 8 | Extra for providing and mixing water proofing material in cement conc. Work in doses by weight of cement as per manufacturer’s specifications |
| 9 | Making plinth protection 50 mm thick of cement conc. conc. 1:3:6(1 cement:3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed, consolidated and grouted with fine sand incl. Finishing the top smooth. |
| 10 | Providing and Laying in position specified grade of reinforced cement concrete excluding the cost of centring and shuttering-All work up to plinth level 1:1.5:3(1 cement;1.5 coarse sand:3 graded stone aggregate 20 mm nominal size) crushed. |
| 11 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string, courses, fillets, columns, pillars, piers, abutments, posts and struts etc up to floor five level excluding cost of centring, shuttering , finishing and reinforcement 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15 degree, landings balconies, shelves, chajjas, lintels, bands, plain window skills, staircases and spiral stair cases upto floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement:1.5 coarse sand:3 graded stone aggregate 20mm nominal size). |
| 13 | Centring and shuttering including strutting , propping etc and removal of forms forFoundations, footings, bases of columns etc. For mass concrete. |
| 14 | Centring and shuttering including strutting, propping etc and removal of forms for Suspended floors, roofs, landings, balconies and access platform. |
| 15 | Centring and shuttering including strutting, propping etc and removal of form for Lintels, Beams, plinth beams, girders, bressumers and cantilevers. |
| 16 | Centring and shuttering including strutting, propping etc and removal of form for Columns, pillars, piers, abutments, posts, and struts. |
| 17 | Centring and shuttering including strutting, propping etc and removal of form for Edges of slabs and breaks in floors under 20 cm wide |
| 18 | Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete. Thermo mechanically treated bars. |
| 19 | Brick work with F.P.S bricks of class designation 75 in foundation and plinth in cement mortar 1:6 (1 cement: 6 coarse sand) |
| 20 | Extra for brick work in superstructure above plinth level upto floor V level |
| 21 | Providing and fixing 1 mm thick M.S steel door with frame of 40X40X6 mm angle iron, 3 mm M.S. gusset plates at the junction and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angle for diagonal braces. |
| 22 | Providing and fixing ISI marked steel glazed doors, windows and ventilators of standard rolled steel sections, joints mitred and welded with 15x3mm lugs, 10cm longs, embedded in cement concrete blocks 15x10x10cm of 1:3:6(1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) or with wooden plugs and scress or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of glass panes with glazing clips and special metal sash putty of approved make complete including applying a priming coat of approved steel primer, excluding the coat of metal beading and other fittings except necessary hinges or pivots as required. |
| 23 | Windows fixed |
| 24 | Windows side hung |
| 25 | Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc are required.In gratings, frames, guard bar, ladders, railings, brackets, grates and similar works |
| 26 | Providing and fixing fly proof gauge to windows with M.S. flat 15x3 mm and nuts and bolts complete.Galvanised M.S. wire gauge with 0.63 mm dia. wire and 1.44 mm aperture on both sides |
| 27 | Cement concrete flooring 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. Complete. 40 mm thick with 12.5 mm nominal size stone aggregates -crushed. |
| 28 | Cement plaster skirting (upto 30cm height) with cement mortar 1:3( 1 cement: 3 coarse sand) finished with a floating coat of neat cement)18mm thick |
| 29 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resistant mortar beading and joints filled with acid and/or alkali resistant cement as per I.S:4457, complete as per directions of the Engineer-in-charge |
| 30 | In flooring over a bed of 10 mm thick mortar 1:4(1 acid proof cement: 4 coarse sand). |
| 31 | In dado/skirting on 12 mm thick mortar 1:4(1 acid proof cement: 4 coarse sand). |
| 32 | Providing and fixing Ist quality ceramic glazed tiles conforming to IS 15622 of minimum thickness 5mm of approved make like NITCO, ORIENT, SOMANY KAJARIA or equivalent make in all colour, shades except begundy, bottle green,black of any size as approved by Engineer incharge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3(1 cement: 3 coarse sand) and jointing with grey cement slurry # 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 33 | Providing and fixing ceramic glazed floor tiles 300x300mm (thickness to be specified by the manufactures) of Ist quality conforming of Is: 13755 of NITCO, ORIENT, SOMANY, KAJARIA Or equivalent make incolour such as White, Ivory, Grey, Fume Red Brown laid on 20mm thick bed of cement mortar 1:4(1 cement: 4 coarse sand) including pointing the joints with white cement and matching pigment etc complete |
| 34 | Painting top of roof with bitumen of approved quality at 17 kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil, complete. With residual type petroleum of penetration 80/100 VG-10 |
| 35 | Providing 10 mm thick(av.) Mud phaska of damped brick earth on roof laid to slope, consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay: 1 cow dung) and covered with flat tile bricks of class designation 100, grouted with cement mortar 1:3 (1 cement: 3 fine sand) mixed with 2% of integral waterproofing compound by weight of cement and finishing neat. |
| 36 | Providing gola 75x75 mm in cement conc. 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 10 mm and down gauge) incl. Finishing with cement mortar 1:3 (1 cement:3 fine sand) as per standard design in 75x75 mm deep chase |
| 37 | Making khurras 45x45 cm with average thickness of 5 cm. cement conc. 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) over P.V.C. sheet 1m x 1m x 400 microns finished with 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 38 | Providing and fixing on wall face unplasticised –Rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion. (i) Single socketed pipes |
| 39 | 75mm diameter |
| 40 | 110mm diameter |
| 41 | Providing and fixing on wall face un-plasticised PVC moulded fittings/ accessories for un-plasticised – Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion.Coupler 110mm |
| 42 | Single tee with door 110x110x110mm |
| 43 | Bend 87.5* 110mm bend |
| 44 | Shoe (Plain) 110mm shoe |
| 45 | Providing and fixing un-plasticised PVC Pipe clips of approved design to un-plasticised PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4(1 cement: 4 coarse sand) and making good the wall etc complete. 110mm |
| 46 | 12mm cement plaster of mix 1:6(1 cement:6 fine sand) Total wall surface |
| 47 | 15mm cement plaster of mix 1:6(1 cement:6 fine sand) |
| 48 | 6mm cement plaster to ceiling of mix 1:3(1cmeent: 3 fine sand) |
| 49 | Finishing walls with water proofing cement paint of required shade New work (two or more coats applied @ 3.84 kg/10 sqm) |
| 50 | Distempering with first quality acrylic washable (ready made) of approved manufacture and of required shade/colour complete as per manufacturer’s specifications-two or more coats on new work |
| 51 | Providing and fixing water closet squatting pan (Indian type WC Pan) with 100mm sand cast iron P or S trap, 10 litre low level white PVC flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, Parry ware/Hind ware /Seabird/Orient (Coral)/ Hindustan/Cera with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White vitreous China Orissa Pattern WC pan of size 580x440mm with internal type foot rests. |
| 52 | Providing and fixing wash basin with CI/MS brackets 15mm C P Brass pillar taps, 32mm CP Brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. Wash basin size 630x450mmwith a single 15mm CP Brass pillars taps |
| 53 | Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fitting complete 32mm dia flexible pipe |
| 54 | Providing and fixing 100mm Stainless Steel grating for gully, floor or Nahani trap |
| 55 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with CP brass screws and washers complete. |
| 56 | Providing and fixing PVC terminal guard100 mm Sand cost Iron S and S as per IS:1729 |
| 57 | Providing and fixing trap of self-cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 100mm inlet and 100mm outlet Sand cost Iron S and S as per IS:1729 |
| 58 | Providing and fixing PTMT towel ring trapezoidal shape 215mm long, wide with a minimum distance of 37mm from wall face with concealed fittings arrangements of approved quality and colour weighing not less than 88 gm |
| 59 | Providing and fixing GI Pipes complete with GI fittings and clamps, including cutting and making good the walls. 15 mm dia. nominal bore |
| 60 | 20 mm dia. nominal bore |
| 61 | Providing and fixing ball valve (brass) of approved quality complete 20mm nominal bore |
| 62 | Providing and fixing un-plasticised PVC connection pipe with brass unions 15mm bore, 45 cm long |
| 63 | Providing and fixing CP brass shower rose with 15 mm inlet 150 mm dia. |
| 64 | Providing and fixing CP brass bib cock of approved quality conforming to IS 8931 15mm nominal bore |
| 65 | Providing and fixing CP Stop cock (concealed) of standard design and of approved make conforming to IS: 8931 a)15mm nominal bore |
| 66 | Providing and fixing C.P brass angle valve for basin mixer and geyser points of approved make conforming to IS 8931 a)15mm nominal bore |
| 67 | Providing and fixing C.P brass soap dish(Note: PTMT soap dish has not been considered therefore C.PGP brass soap dish not in schedule) |
| 68 | Providing and placing on terrace polyethylene water storage tank ISI:12701 marked indicating the BIS Licence No. With cover and suitable locking arrangements and making necessary holes for inlet, outlet and overflow pipes but without fittings and base support for tank. |
| 69 | Providing, laying and jointing Glazed Stoneware Pipes grade A with stiff mixture of cement mortar in proportion of 1:1 (1 cement: 1 fine sand) incl. testing of joints etc. Complete. and Laying in position cement concrete 1:5:10(1 cement:5 coarse sand:10 graded stone aggregate 40 mm nominal size) around pipes incl. Bed conc. As per standard design.-150 mm pipes- 150 mm dia. |
| 70 | Providing and Laying in position cement concrete 1:5:10(1 cement:5 coarse sand:10 graded stone aggregate 40 mm nominal size) around pipes incl. Bed conc. As per standard design.-150 mm pipes |
| 71 | Constructing brick masonry manhole in cement mortar 1:4(1 cement: 4 coarse sand) ) RCC top slab with 1:1.5:3 mix (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 (1 cement: 4 fine sand: 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3(1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement and making channels in cement conc. 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 40mm nominal size) finished with a floating coat of neat cement complete as per standard design. Inside size 80x90 cm and 45 cm deep incl. C.I cover with frame (Light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of and weight of frame 15 kg) With FPS bricks with class designation 75. |
| 72 | Making Soak Pit 2.50 m dia. 3.00 m deep with 45x45 cm dry honeycomb shaft with bricks of class designation 75 and SW drain pipe 100 mm dia. 1.80 m long complete as per standard design.With FPS bricks with |
| 73 | Providing and installing water lift pump 1HP incl. all accessories |
| 74 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work |
| 75 | Internal Electrification of CR Building as per requirement by incharge engineer |
| 76 | Other Misc. Works |
| 77 | Compound walling of identified land by way of 3ft in height Mass Concrete in Foundations and 228 mm Brick Wall of 2 Mtr. complete height |
| 78 | Chainlink Fencing of 33 kV Yard of Substation by way of 3ft Mass Concrete in Foundations and chainlink fencing of 6 ft height |
| 79 | HDPE Pipe Outer Dia 180 mm Inner Dia 152 mm for laying of 11kV XLPE Cable from Power Transformer to Control Room |
| 80 | 33/11 kV Power Transformer Foundation 3Mx3Mx1.83M with reinforcement as REC |
| 81 | 33 kV Equipment Foundation & Gantry foundation as per REC standards |
| 82 | Earthing Mat (GI Flat 50 mm x8 mm) as per REC Standards |
| 83 | Earthing Electrode ( 3m long 40mm dia GI pipe) through GI Strip. |
| 84 | 33 kV Yard Concreting 4inch in height as per yard size available |
| 85 | Bore well with submersible pump and electrical accessories complete in all respect |
| 86 | Truss for new Control Room Building 1.3x Plinth area (Providing and Fixing of Steel Truss including provision of Colour Coated Roofing |
| 87 | Development of land by removing weeds, wild, grass and endulation if any, ornamental land scaping and growing of ornamental trees in un built areas and road sides and development of approach roads with metalling along with surface drains |
| 88 | Yard Lightening by erection of 9mtr STP pole 4no. complete assembly with 45Watt LED lights |
| 89 | Construction of R/Wall (1:3:5 PCC 40% Plump Stones) 55Mx1.70Mx1.60M Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender